Test report 02

FCC ID: O2J-235AS

Test Report

Download: PDF
FCCID_1551059

 Frequency Stability Measurements
                           For
     Airspan Communications Ltd
Airsynergy 2.3 GHz TDD base station
              FCC ID: O2J-235AS


                    SC_TR_39_B


                     05 September 2011




                    Sulis Consultants Limited
Mead House, Longwater Road, Eversley, Hampshire, RG27 0NW, UK
       Registered in England & Wales, number 05466247
               http://www.sulisconsultants.com


                                              Contents
1   Revision History ................................................................................ 3
2   Associated Documents........................................................................ 3
3   Test Configuration ............................................................................. 4
  3.1   Measurement method................................................................... 5
4   Test Results ...................................................................................... 5
5   Test Equipment ................................................................................. 6



                                               Tables
Table 1: Equipment under test................................................................... 4
Table 2: Test results ................................................................................ 5
Table 3: List of Test Equipment.................................................................. 6


                                               Figures
Figure 1: Test Configuration ...................................................................... 4
Figure 2: Example FSQ data capture (48V at 20°C)....................................... 6




SC_TR_39_B                                                                                 Page 2 of 6


1 Revision History
Revision       Originator     Date                   Comment


      A        C Blackham     16 August 2011         First Issue

      B        C Blackham     05 September 2011      Typo corrected in table 2




2 Associated Documents

[1]       47CFR2               Title 47 of FCC Rules Part 2
[2]       ANSI / TIA-603-C-    TIA Standard: Land Mobile FM or PM – Communications
          2004                 Equipment – Measurement and Performance Standards




SC_TR_39_B                                                                   Page 3 of 6


3 Test Configuration
The unit shall be connected in a real-life representative manner as follows:




                          Airsynergy




      Co-ax RF cable                         Drop cable
                                             (Cat5)
     With attenuation




                                                          Equipment under Test
                                                           In Thermal Chamber


                                                             Support Equipment


         FSQ                         POE injector
                                                            48 V supply




                           Figure 1: Test Configuration


          Item                    Part Number                Serial Number
       Airsynergy             SYN2-CN-00-U40-000              9B2312FFFF23
                                                            (baseband board)
                         Table 1: Equipment under test




SC_TR_39_B                                                                Page 4 of 6


  3.1 Measurement method
     The EUT was placed into the thermal chamber and connected to a DC
      supply and FSQ measuring receiver outside the chamber
     The EUT was placed into commissioning mode and set to transmit a test
      waveform at 2347.9 MHz.
     The FSQ is fitted with the WiMAX 802.16e option and was set to reported
      Frequency error in Hz relative to expected frequency of 2347.9 MHz
     The Temperature of the chamber was varied between -30°C and +50°C in
      10°C steps and the EUT temperature allowed to stabilise for one hour at
      each. Supply voltage was also varied when chamber was at 20°C.
     Frequency error was measured by the FSQ and the results shown in
      section 4.

4 Test Results

                                                       Freq Error
           Temp     Voltage     Freq Err (Hz)            (ppm)
            (°C)     (V dc)
                                 Tx1      Tx2         Tx1     Tx2
             -30       48       -3176    -3194        -1.4    -1.4
             -20       48       -2936    -2925        -1.3    -1.2
             -10       48       -2995    -2988        -1.3    -1.3
              0        48       -3049    -3046        -1.3    -1.3
             10        48       -2418    -2408        -1.0    -1.0
                      40.8       -900     -902        -0.4    -0.4
             20        48        -904      903        -0.4    0.4
                      55.2       -891     -896        -0.4    -0.4
             30        48       -2038    -2045        -0.9    -0.9
             40        48       -2617    -2593        -1.1    -1.1
             50        48       -3239    -3237        -1.4    -1.4
                              Table 2: Test results




SC_TR_39_B                                                           Page 5 of 6


                                                         IE E E 8 0 2 . 1 6 e - 2 0 0 5 O F D M A

Frequency/Fs:         2.3479 GHz / 4 M H z        Signal Lvl. Setting/Ext. A tt:
                                                                              -13.3 dBm / 4 1 dB          C apture Time/No.Samples:   1 5 ms /6 0 0 0 1
Seg=0, DL-PUSC , ID=A                        3 (3) Meas Setup:                    1 T X x 1 RX            Zone O ffset / Len:          1 / 2 0 Symbols
C O NTINUO US                TRG : ..                                           RF
                                                  Result S ummary of A nalyzed S ubframes

No. of Subframes                        3

                                                   Min                            Mean                 Limit                Max          Limit      Unit

C enter Frequency Error                            - 9 0 4 .2 4             - 9 04 .54              ± 18783          - 9 0 4 .7 6     ± 18783     Hz

C lock Error                                          - 0.4 3                  - 0 .48                  ±8              - 0.5 5            ±8     ppm


T D Power DL Preamble                                    28 .36                 2 8.3 6                                  28 .36                  dBm

T D Power Subframe                                       25 .03                 2 5.0 3                                  25 .03                  dBm


T D Power Zone                                           24 .79                 2 4.8 0                                  24 .80                  dBm

C rest Factor                                             9.6 5                   9 .66                                   9.6 6                   dB


RSSI                                                     27 .78                 2 7.7 8                                  27 .78                  dBm

RSSI Standard Deviation                                                       - 1 3.2 2                                                          dBm

C INR                                                    25 .26                 2 5.2 7                                  25 .27                   dB

C INR Standard Deviation                                                        2 5.2 6                                                           dB




        Running ...


Date: 21.JUL.2011                 08:57:13


                             Figure 2: Example FSQ data capture (48V at 20°C)




5 Test Equipment

                  Item                                       Serial Number                                              Calibration
            R&S FSQ 26                                    Airspan No 005316                                     Cal Date 2011-06-14
                                                              S/N 200022                                        Cal Ref 1400-37051


                                               Table 3: List of Test Equipment




SC_TR_39_B                                                                                                                            Page 6 of 6



Document Created: 2011-09-05 18:34:48
Document Modified: 2011-09-05 18:34:48

© 2024 FCC.report