Plot Assisted Setups

FCC ID: NX5DSSR-250C

Users Manual

Download: PDF
FCCID_669146

RVP8 User’s Manual
October 2004                                                                   Plot–Assisted Setups




4. Plot-Assisted Setups
The IFD receiver module replaces virtually all of the IF components in a traditional analog
receiver. The alignment procedures for those analog components are usually very tedious, and
require continued maintenance even after they are first performed. Subtle drifts in component
specifications often go unnoticed until they become so severe that the radar’s data are
compromised.
The RVP8 makes a big improvement over this by providing an interactive graphical alignment
procedure for burst pulse detection, Tx/Rx phase locking, and calibration of the AFC feedback
loop. You may view the actual samples of the burst pulse and receiver waveform, examine their
frequency content, design an appropriate matched filter, and observe live operation of the AFC.
It is a simple matter to check the spectral purity of the transmitter on a regular basis, and to
discover the presence of any unwanted noise or harmonics. Moreover, the RVP8 is able to track
and modify the initial settings so that proper operation is maintained even with changes in
temperature and aging of the microwave components.
The Plot-Assisted Setups are accessed using the various “P” commands within the normal TTY
setup interface. These commands are described later in this chapter. The RVP8 supports
opcodes that allow the host computer to monitor the data being plotted. The dspx utility can
display these plots directly on the workstation screen, and thus, can carry out the graphical
checkup and alignment procedures remotely via a network.




                                               4–1


RVP8 User’s Manual
October 2004                                                                       Plot–Assisted Setups



4.1 P+ — Plot Test Pattern
The RVP8 can produce a simple test pattern to verify that the display software is working
properly. From the TTY monitor enter the “P+” command. This will print the message
“Plotting Test Pattern...” on the TTY and then produce the plot shown in Figure 4–1.
This display is actually an overlay of six different strokes: 1) bottom line, 2) middle line, 3) top
line, 4) line sloping up, 5) line sloping down, and 6) the sine wave pattern. The later changes
phase with each plot so that, with a little imagination, it appears to be radiating from the left side
of the display.




           Figure 4–1: The Test Pattern Display
When you are satisfied that the plot is being drawn correctly, type “Q” or hit ESC to return to
the TTY monitor.




                                                 4–2


RVP8 User’s Manual
October 2004                                                                      Plot–Assisted Setups



4.2 General Conventions Within the Plot Commands
The “Pb”, “Ps”, and “Pr” commands all have a similar structure to their TTY user interface.
Each command begins by printing a list of subcommands that are valid in that context. These
subcommands are single keystrokes that are executed immediately by the RVP8 as they are
typed. The “ENTER” key is not required. The available subcommands are different for each
plot command; but, as much as possible, each key has a similar meaning across all commands.
The working and measured parameters for each plot command are printed on the TTY as two
lines of information following the subcommand list. The first line contains settings that only
change when a subcommand is issued; but the second line is live and reflects the current status
of the burst input, the IF input, or the AFC output. The first line is printed just once, but the
second line is continually overprinted on top of itself. This makes it appear as a live status line
whose values always remain up to date. The ”Pb”, ”Ps”, and ”Pr” commands will report ”No
Trigger” on the TTY status line whenever the external trigger is expected but missing.
The TTY screen will scroll upward each time a new subcommand is executed, so that a history
of information lines and command activity can be seen on the screen. You may also use the
Carriage-Return key to scroll the display up at any time. If the initial list of subcommands
disappears off the top, you may type “?” to force a reprint. To exit the plot command entirely
and return to the TTY main menu type “Q” or ESC. These basic “help” and “exit” keystrokes
apply everywhere within the RVP8 setup menus. To save space and minimize clutter on the
TTY screen, they are not shown in the itemized list of subcommands.
Most commands have a lowercase and an uppercase version. If a lowercase command does
something, then its uppercase version does the same thing but even more so (or in reverse). For
example, if the “w” subcommand widens something by a little bit, then “W” would widen it a
lot. This simple convention reduces the number of different subcommand keys that are needed,
and makes the interface easier to memorize.
The graphical display and TTY status lines are continually updated with fresh data several times
per second. Occasionally it is useful to freeze a plot so that it can be studied in more detail, or
compared with earlier versions. To accomplish this, every plotting command supports a “Single
Step” mode that is accessed by typing the “.” (period) key. This key causes the display and TTY
status lines to freeze in their present state, and the message “Paused...” will be printed.
Subsequently, typing another “.” will single step to the next data update, but the plot and printout
will still remain frozen. Typing “Q” or ESC will exit the plot command entirely (as they
normally do). All other keys return the plot command to its normal live updating, but the key is
otherwise discarded (i.e., subcommand keys are not executed while exiting from single step
mode).
All of the plot commands support subcommands whose only purpose is to alter the appearance
of the display, e.g., zoom, stretch, etc. These subcommands make no changes to the actual
working RVP8 calibrations. However, the display settings are stored in nonvolatile RAM just
like all of the other setup parameters. This means that all previous display settings will be
restored whenever you restart each plot command. This is very convenient when alternating
among the various plots.


                                                 4–3


RVP8 User’s Manual
October 2004                                                                     Plot–Assisted Setups



The “Pb”, “Ps”, and “Pr” commands are intended to be used together for the combined purpose
of configuring the RVP8’s digital front end. You may, of course, run any of the commands at
any time; but the following procedure may be used as a guideline for first time setups. The full
procedure must be repeated for each individual pulsewidth that the radar supports.
           1. Use Mb to set the system’s intermediate frequency (See Section 3.2.6).
           2. Use Mt to choose the PRF and pulsewidth (See Section 3.2.4). Also, choose the
              range resolution now, as it may constrain the design of the matched filter later.
           3. Use Mt0, Mt1, etc., to set the relative timing of all RVP8 triggers that are used by
              the the radar. Do not worry about the absolute values of the trigger start times.
              Just setup their polarity and width, and their start times relative to each other (See
              Section 3.2.5). Make an initial guess of FIR filter length as 1.5 times the
              pulsewidth.
           4. Use Pb to slew the start times of all triggers so that the burst pulse is properly
              sampled (See Section 4.3). Refine the impulse response length if necessary so
              that all samples easily fit within the display window.
           5. Use Ps to design the matched FIR filter (See Section 4.4). Further refine the
              impulse response length and passband width to achieve a filter that matches the
              spectral width of the burst, and that has strong attenuation at DC. If the FIR
              length is changed, return to Pb to verify that the burst is still being sampled
              properly.
           6. Continue using Ps and Mb to tune up the AFC feedback loop. The settings that
              work for one pulsewidth should also work for all others.
           7. Use Pr to verify that targets are being detected with good sensitivity (See Section
              4.5).
Sometimes it is useful to run the Pb and Ps commands with samples from the IF-Input of the
IFD, rather than from the Burst-Input. Likewise, it is sometimes useful to view the Pr plots on
samples of Burst data. The top-level “~” command (See Section 3.3.3) allows you to do this
easily.




                                                4–4


RVP8 User’s Manual
October 2004                                                                     Plot–Assisted Setups



4.3 Pb — Plot Burst Pulse Timing
For magnetron radars the RVP8 relies on samples of the transmit pulse to lock the phase of its
synthesized “I” and “Q” data, and to run the AFC feedback loop. The “Pb” command is used to
adjust the trigger timing and A/D sampling window so that the burst pulse is correctly measured.

4.3.1 Interpreting the Burst Timing Plot
The display plot will ultimately resemble Figure 4–2, which shows a successful capture of the
transmitter’s burst pulse. The horizontal axis of the display represents time, and the overall time
span from the left edge to the right edge is listed as “PlotSpan” on the TTY.




           Figure 4–2: Successful Capture of the Transmit Burst
The upper portion of the plot shows the sampling window wherein the burst pulse is measured.
The duration of this window is determined by the impulse response length of the matched FIR
filter. This is because the same FIR coefficients that compute “I” and “Q” are also used to
compute the reference phase vectors for the burst pulses. The A/D samples of the RVP8/IFD’s
burst input are plotted (somewhat brighter) within the sample window.
The RVP8 computes the power-weighted center-of-mass (COM) of the burst pulse envelope.
This allows the processor to determine the location of the “middle” of the transmitted pulse
within the burst analysis window. The Pb plot displays small tick marks on the top and bottom
of the burst sample window to indicate the location of the COM. These markers are only
displayed when valid burst power is detected. A second “error bar” is drawn surrounding the
tick mark to indicate the uncertainty of the mark itself. This error interval is used by the burst
pulse tracking algorithm to decide when a timing change can be made with confidence.


                                                4–5


RVP8 User’s Manual
October 2004                                                                     Plot–Assisted Setups



It is possible to independently choose a subinterval of burst pulse samples that are used by the
AFC frequency estimator. Thus, the AFC feedback loop is not constrained to use the same set of
samples that are chosen for the FIR filter window. The FIR window typically is longer than the
actual transmitted pulse, and thus, the samples contributing to the frequency estimate will
include the leading and trailing edges of the pulse. These edges tend to have severe chirps and
sidebands, compared to the more pure center portion of the pulse. The AFC frequency estimate
(which is power weighted) could be mislead by these edges and might not tune to the optimum
center frequency if they were included.
The lower portion of the plot shows the six triggers that are output by the RVP8. Trigger #0 is at
the top, and Trigger #5 is on the bottom. They are drawn in their correct polarity and timing
relative to each other, and relative to the burst sample window. Note that the sample window is
always drawn in the center of the overall time span. Thus, depending on the PlotSpan and
location of the six trigger’s edges, triggers that do not vary within the plotted time span will
appear simply as flat lines.
The RVP8 defines “Range Zero” to occur at the center of the burst sample window. This also
defines the zero reference point for the starting times of the six programmable triggers. For
example, a trigger whose starting time is zero will be plotted with its leading edge in the exact
horizontal center of the display. Knowing this convention makes the absolute value of the
trigger start times more meaningful.

4.3.2 Available Subcommands Within “Pb”
The list of subcommands is printed on the TTY:
Available Subcommands within ’Pb’:
     I/i     Impulse response length Up/Dn
  A/a & S/s Aperture & Start of AFC window
  L/l & R/r Shift triggers & RVP8/Tx waveform left/right,
     T/t     Plot time span Up/Dn
     Z/z     Amplitude zoom
     B/b     BP Tracking On/Off (temporary)
      +      Hunt for missing burst
      .      Single Step
These subcommands change the matched filter’s impulse response length, shift the radar
triggers, and alter the format of the display.
    I/i                   The “I” command increments or decrements the length of the matched
                          filter’s impulse response. Each keystroke raises or lowers the FIR
                          length by one tap.
  A/a & S/s               These commands raise/lower the aperture/start of the subwindow of
                          burst pulse samples for AFC. If you never use these commands, then
                          the full FIR window will be used; however, shortening the AFC
                          interval will result in two sample windows being drawn on the plot.
                          The smaller AFC window should be positioned into the center portion
                          of the transmitted pulse, where the burst amplitude and frequency are
                          fairly stable.


                                                4–6


RVP8 User’s Manual
October 2004                                                                   Plot–Assisted Setups



  L/l & R/r             These two commands shift the entire group of six RVP8 triggers left
                        or right (earlier or later in time). The lowercase commands shift in
                        0.025 msec steps, and the uppercase commands shift in 1.000 msec
                        steps (approximately). The reason for shifting all six triggers at once
                        is that the relative timing among the triggers remains preserved.
                        However, the absolute timing (relative to range zero) will vary, and
                        this will cause the burst pulse A/D samples to move within the sample
                        window.
    T/t                 The “T” command increments or decrements the overall time span of
                        the plot. The available spans are 2, 5, 10, 20, 50, 100, 200, 500, 1000,
                        2000 and 5000 microseconds. The value is reported on the TTY as
                        “PlotSpan”.
    Z/z                 The “Z” command zooms the amplitude of the burst pulse samples so
                        that they can be seen more easily. The value is reported on the TTY as
                        “Zoom”.
    B/b                 These keys temporarily disable or re-enable the Burst Pulse Tracker.
                        The tracker must be disabled in order for the L/R keys to be used to
                        shift the nominal trigger timing. The “b” key disables tracking and
                        sets the trigger slew to zero; the “B” key re-enables tracking starting
                        from that zero value.
     +                  The “+” subcommand initiates a hunt for the burst pulse. Progress
                        messages are printed as successive AFC values are tried, and the
                        trigger slew and AFC level are set according to where the pulse was
                        found. If no burst pulse can be found, then the previous trigger slew
                        and AFC are not changed.

4.3.3 TTY Information Lines Within “Pb”
The TTY information lines will resemble:
Zoom:x2, PlotSpan:5 usec, FIR:1.36 usec (49 Taps)
Freq:27.817 MHz, Pwr:–53.9 dBm, DC:0.14%, Trig#1:–5.00, BPT:0.00

  Zoom                  Indicates the magnification (in amplitude) of the plotted samples. A
                        zoom level of “x1” means that a full scale A/D waveform exactly fills
                        the height of the sample window. Generally, the signal strength of the
                        burst pulse will not be quite this high. Thus, use larger zoom levels to
                        see the weaker samples more clearly. You may zoom in powers of two
                        up to x128.
  PlotSpan              Indicates the overall time span in microseconds of the complete scope
                        display, from left edge to right edge.
    FIR                 Indicates the length of the impulse response of the matched FIR filter,
                        and hence, the duration of the burst pulse sample window. The length
                        is reported both as a number of taps, and as a time duration in
                        microseconds.


                                             4–7


RVP8 User’s Manual
October 2004                                                                       Plot–Assisted Setups



   Freq                    Indicates the mean frequency of the burst, derived from a 4th order
                           correlation model. The control parameters for this model are set using
                           the “Mb” command (Section 3.2.6).
   Pwr                     Indicates the mean power within the full window of burst samples.
                           DC offsets in the A/D converter do not affect the computation of the
                           power, i.e., the value shown truly represents the waveform’s
                           (Signal+Noise) energy.
    DC                     Indicates the nominal DC offset of the burst pulse A/D converter. This
                           is of interest only as a check on the integrity of the front end analog
                           components. The value should be in the range 2.0%.
   Trig#1                  Indicates the starting time of the first (of six) RVP8 trigger outputs.
                           This number will vary as the “L” and “R” subcommands cause the
                           triggers to slew left and right. Note that if the radar transmitter is
                           directly fired by an external pretrigger, then the pretrigger delay (in
                           the form “PreDly:6.87”) will be printed instead.
    BPT                    This shows the present value of timing slew (measured in
                           microseconds) being applied to track the burst. The slew will be zero
                           initially when the RVP8 is first powered up, meaning that the normal
                           trigger start times are all being used.

4.3.4 Recommended Adjustment Procedures
The burst pulse timing must be calibrated separately for each individual pulsewidth. Repeat the
following procedure for each pulsewidth that you plan to use. Each iteration is independent.
It is first necessary to setup the proper relative timing for all RVP8 triggers that are being used.
The six trigger output lines are completely interchangeable, and each may be assigned to any
function within the radar system. For example, Trigger #0 might be the transmitter pretrigger,
Triggers #2 and #3 might synchronize external displays, and Triggers #1, #4, and #5 might be
unused.
Choose an initial impulse response length of 1.5 times the transmit pulsewidth. This length will
be refined later when the matched filter is designed (See Section 4.4). Adjust the plot time span
to view a small region around the sample window, and set the initial amplitude zoom to x16.
This assures that the plotted waveform will still be noticeable even if the burst signal strength is
very weak.
Verify that the transmitter is radiating, and observe the burst pulse samples on the display. Use
the “L” and “R” commands to shift the timing of all six triggers relative to range zero. This has
the effect of moving the burst sampling window relative to the transmitted pulse. Depending on
whether the triggers are set properly, you may at first see nothing more than a flat line of
misplaced A/D samples. However, after a few moments of hunting, the burst pulse should
appear on the display screen. Fine tune the triggers so that the burst envelope is centered in the
window, and adjust the amplitude zoom for a comfortable size display.
The clean center portion of the burst pulse should then be isolated to a narrower subwindow of
the overall FIR interval. Use the”A” and “S” commands to change the aperture and start of the
narrowed region from which the AFC frequency estimator’s data will be derived.


                                                 4–8


RVP8 User’s Manual
October 2004                                                                  Plot–Assisted Setups



Check that the burst pulse signal strength is reasonably matched to the input span of the
RVP8/IFD’s A/D converter. The maximum analog signal level is +4dBm. Exceeding this level
produces distorted samples that would seriously degrade the algorithms for phase locking and
AFC. However, if the signal is too weak, then the upper bits of the A/D converter are wasted
and noise is unnecessarily introduced. We recommend a peak signal level between –6dBm and
+1dBm, i.e., a signal that might be viewed at x2 or x4 zoom. Take note of the burst energy level
reported on the TTY; it will help decide the minimum energy threshold for a valid burst pulse,
which is needed in Section 3.2.6.




                                              4–9


RVP8 User’s Manual
October 2004                                                                     Plot–Assisted Setups



4.4 Ps — Plot Burst Spectra and AFC
Once the transmit burst pulse has been captured the next step is to analyze its frequency content
and to design a bandpass filter that is matched to the pulse. In a traditional analog receiver the
matched filters use discrete components that can not be adjusted, and the transmit spectrum can
not be viewed unless a spectrum analyzer is on hand. The RVP8 eliminates all of these
restrictions via its “Ps” command, which plots the burst spectrum, designs the bandpass filter,
plots its frequency response, and also helps with alignment of the AFC.


4.4.1 Interpreting the Burst Spectra Plots
An example of a plot from the Ps command is shown in Figure 4–3. The display screen is
divided into two independent areas. The major portion (the lower seven eighths) is devoted to
power spectrum plots of the burst pulse and/or the matched filter response. The top portion
(single line) serves as a visual indicator of the present AFC level.




           Figure 4–3: Example of a Filter With Excellent DC Rejection
The horizontal axis of the spectrum plot represents frequency. The overall span from the left
edge to the right edge is 36MHz for the RVP8 CAT-5E IFD, and 18MHz when the legacy RVP7
FibreOptic IFD is used. The remainder of this chapter will refer only to the newer RVP8 unit.
The exact endpoints of the plot depend on which alias band the radar’s intermediate frequency
falls in. For example, a 30MHz IF would imply a horizontal axis range of DC to 36MHz,
whereas a 60MHz IF would make the range 36MHz to 72MHz. The frequency span is printed
on the TTY when the command is first entered. Since the left edge of the spectral plot always


                                               4–10


RVP8 User’s Manual
October 2004                                                                        Plot–Assisted Setups



represents an integer multiple of 36MHz, either the left side or the right side will always be a
multiple of 36MHz. This is important to remember when designing the matched filter, since
fixed DC offsets in the A/D converters will appear aliased at these 72MHz multiples.
The vertical axis of the spectrum plot is logarithmic and is marked with faint horizontal lines in
10-dB increments. An overall dynamic range of 70 dB can be viewed at once. The horizontal
lines also contain major and minor tick marks to help calibrate the frequency axis. Major marks
are small downward triangles that represent integer multiples of 5MHz; minor marks are in
between and represent 1-MHz steps. The power spectrum example in Figure 4–3 is from a
system with an intermediate frequency of 30MHz. Thus, the left edge of the plot begins at DC,
and the graph is centered on the sixth major tick, i.e., 30MHz.
Two types of spectra can be plotted on the screen: 1) the frequency response of the FIR filter,
and 2) the frequency content of the burst pulse itself. The burst spectrum is computed by first
applying a Hamming window to the raw samples. You may choose to view either plot
individually, or both at the same time.
Figure 4–3 is an example of a single filter response plot, whereas Figure 4–4 shows a combined
display of both spectra. The combined display makes it easy to compare the filter being
designed with the live waveform that it is intended to selectively pass. Note that the filter’s
frequency response is always drawn with its passband peak touching the top of the plot. The
vertical height of the burst spectrum, however, will vary with signal strength but can be adjusted
using the “Z” subcommand.
The horizontal line at the top of the plotting area is also marked with an upward pointing major
and minor tick. These indicate the present value of the burst pulse frequency estimator. The
major tick is a triangle whose position along the horizontal axis corresponds directly to the
estimated frequency. It should always be positioned directly over the main lobe of spectral
power. The minor tick gives finer scale resolution by indicating the fractional part of each
1-MHz multiple.
It is helpful to read the minor tick relative to the ten horizontal division lines that are present on
most scopes. Motion of the minor tick is apparent even with very small changes in burst pulse
frequency; a change of just 5 KHz can easily be seen. This means that you can observe the
frequency drift of the magnetron in great detail, and also watch the AFC’s behavior in real time.
The horizontal line at the very top of the display (above the spectra plot) serves to indicate the
present value of the AFC control voltage. The line contains an upward pointing major and
minor tick, similar to the ones used to represent the burst frequency estimate on the line below.
However, the horizontal axis now represents voltage rather than frequency, and the overall span
is the complete range of the AFC’s digital-to-analog converter. The major tick will move from
the left edge to the right edge as the AFC varies from its minimum to maximum value. The
minor tick will traverse the screen at ten times this rate.




                                                 4–11


RVP8 User’s Manual
October 2004                                                                   Plot–Assisted Setups



4.4.2 Available Subcommands Within “Ps”
The list of subcommands is printed on the TTY:
Frequency span of the plot is 36.0 MHz to 72.0 MHz.
Available Subcommands within ’Ps’:
     I/i     Impulse response length Up/Dn
  N/n & W/w Filter bandwidth Narrower/Wider
  U/u & D/d MFC Up/Down (On/Off ’=’ , Test ’|’)
  A/a & S/s Aperture & Start of AFC window
      #      Print filter coefficients
      $      Search for an optimal filter
     V/v     Number of spectra averaged
     Z/z     Amplitude zoom
   <space>   Alternate Plots
      %      Toggle between dual receivers
      .      Single Step
These subcommands change the design of the matched FIR filter, assist with calibration of the
AFC loop, and alter the format of the display.
    I/i                  The “I” command increments or decrements the length of the matched
                         filter’s impulse response. Each keystroke raises or lowers the FIR
                         length by one tap. Often the matched filter’s characteristics can be
                         very much improved merely by changing the FIR length by one or two
                         taps. Be sure to experiment with this as you design your filter.
  N/n & W/w              The “N” and “W” commands change the passband width of the
                         matched filter, making it narrower or wider. The lower case
                         commands make changes in 1KHz steps, and the upper case
                         commands use 100KHz steps. The value is reported on the TTY as
                         “BW”. Often a small change in passband width will shift the exact
                         locations of the filter’s zeros, and possibly improve the DC rejection.
  U/u & D/d              The “U” and “D” commands implement the Manual Frequency
                         Control (MFC) override, and allow the RVP8/IFD’s AFC output
                         voltage to be manually set to any fixed level. The lower case
                         commands make changes in 0.05 D-Unit steps, and the upper case
                         commands use 1.0 D-Unit steps. The value is reported on the TTY as
                         “AFC”.
     =                   MFC mode is toggled on and off using the “=” key. A warning will be
                         printed if the Ps command is exited while MFC is enabled, and you
                         will be given a second chance to reenable AFC.
     |                   The AFC test submode is entered by typing the “|” key. The following
                         list of keybindings will be shown, and will remain in effect until the
                         test mode is exited by typing “Q”.
               AFC Test Mode Subcommands
                     W      Use Walking–Ones pattern
                     P      Toggle Pin/Bit numbering
                  0–9,A–O   Toggle AFC Bits 0–24 (Pins 1–25)



                                              4–12


RVP8 User’s Manual
October 2004                                                                                  Plot–Assisted Setups



                              2   2   2   2   2   1   1   1   1   1   1   1   1   1   1
                              4   3   2   1   0   9   8   7   6   5   4   3   2   1   0 9 8 7 6 5 4 3 2 1 0
                              –   –   –   –   –   –   –   –   –   –   –   –   –   –   – – – – – – – – – – –
                              O   N   M   L   K   J   I   H   G   F   E   D   C   B   A 9 8 7 6 5 4 3 2 1 0
                       The Ps command continues to run normally during the AFC test
                       mode. The customary AFC information will be replaced with a
                       hexadecimal readout of the present 25-bit value. Your live display
                       may look something like:
               Navg:3, FIR:1.33 usec (48 Taps), BW:1.000 MHz, DC–Gain:ZERO
               Freq:26.610 MHz, Pwr:–64.6 dBm, AFC–Test:0000207F (Bits)


                       Initially, a walking-ones bit pattern will be output in lieu of the normal
                       formatted AFC value. This test pattern shifts a single “1” downward
                       through the AFC word, making a transition approximately every 4ms.
                       It is intended to help ring out and test the wiring for digital AFC
                       installations. The walking-ones test is handy as an oscilloscope
                       diagnostic, and you may return to it at any time by typing “W”.
                       Typing any of the characters “0” through “9” or “A” through “O” will
                       enter a new mode in which a static 25-bit digital AFC pattern is
                       controlled directly. Each key toggles its corresponding bit, as
                       summarized in the keybindings printout. Any 25-bit pattern can be
                       made by toggling the appropriate bits (initially all zero) to one.
                       Within any particular pattern, it is also easy to toggle a particular bit
                       On/Off in order to verify its function.
                       The “P” command lets you decide whether the 25-bit word represents
                       a numeric AFC span that is mapped into pins via the pin-map table in
                       the Mb menu; or whether it represents those pins directly. The printed
                       hex test value will be followed either by “(Bits)” or “(Pins)”
                       accordingly. When in “Pins” mode, the “0” key toggles Pin-1, the “1”
                       key toggles Pin-2, etc. When in “Bits” mode, the “0” key toggles
                       whatever pin or pins have been designated to be driven from Bit-0 of
                       the numeric AFC. The “Pins” mode is useful when you are doing the
                       initial electrical tests of the wiring of each pin. After the pin wiring
                       has been verified and the Mb mapping table has been created, then the
                       “Bits” mode allows you to test the complete digital AFC interface.
     #                 The “#” command results in a printout of the coefficients of the
                       current FIR filter. The values are scaled by the coefficient with the
                       largest absolute value, so that they all fall within the –1 to +1 range.
                       This detailed information may be used to model the behavior of the
                       filter for point targets that fall in between discrete range bins, e.g., as
                       will happen when performing a radar sphere calibration. See Section
                       5.1.1 for the exact definition of these coefficients.
     $                 The “$” command performs an automatic search for optimal (DC gain
                       of zero) filters in the vicinity of the current one. As an example,
                       suppose that we wanted an optimal filter that was approximately 2.2
                       msec long and 650 KHz wide. We would first use the “I/i” and


                                                  4–13


RVP8 User’s Manual
October 2004                                                                  Plot–Assisted Setups



                        “W/wN/n” subcommands to manually move to that starting point.
                        Typing “$” would then print a dialog line in which the search span
                        length and width are chosen. You may keep the indicated values or
                        type in new ones, just as for all RVP8 setup questions. The search
                        begins when the spans are accepted.
                        The search procedure may require a few seconds to a few minutes,
                        depending on the length and width spans that are being scanned.
                        During this time, a progress message is printed showing the length and
                        width currently under examination. You may type “Q” to abort the
                        search and retain the original filter settings. When the search
                        completes normally, it will print “Done” and replace the old filter
                        settings with the best ones that could be found.
                        In dual-receiver mode, the ”$” command will search for a filter that
                        minimizes the maximum width and DC offset at both receiver’s
                        intermediate frequencies. The final filter will be the one that has the
                        best simultaneous performance at both IFs.
    V/v                 The “V” command increments or decrements the number of burst
                        pulse spectra that are averaged together to create the plot. The count
                        ranges from one (no averaging) to 25, and is reported on the TTY as
                        “Navg”.
    Z/z                 The “Z” command zooms (i.e. shifts on a logarithmic scale) in 1.0-dB
                        steps the amplitude of the burst pulse spectra. This is useful when the
                        overall 70dB plot span is not sufficient to hold the full range. Zoom
                        can also be used to line up the burst spectrum with the filter response
                        so that the two can be compared. The zoom level is not printed on the
                        TTY because there is nothing useful that could be done with it.
  <space>               The space bar alternates among three choices for the type of spectra
                        that are plotted: 1) FIR frequency response, 2) Burst pulse spectrum,
                        and 3) Both.
      %                 In dual-receiver mode, the “%” command toggles between each
                        receiver. The printed status line is prefixed with ”Rx:Pri” or ”Rx:Sec”
                        according to which receiver is selected. Specifically, typing “%” will
                        toggle the plot of the FIR filter’s frequency response, and the printout
                        of its DC–Gain. However, the plotted spectrum and printed power
                        levels are always based on the sum of all input signals, and thus do not
                        change with “%“.

4.4.3 TTY Information Lines Within “Ps”
The TTY information lines will resemble:
Navg:3, FIR:1.33usec (48 Taps), BW:1.000, MHz, DC–Gain:ZERO
Freq:30.027 MHz, Pwr:–64.2 dBm, Loss:1.2dB, AFC:23.05% (Manual)
  Navg            Indicates the number of burst spectra that are averaged together prior
                  to plotting. Larger amounts of averaging increase the ability to see
                  subtle spectral components, but the display will update more slowly.


                                            4–14


RVP8 User’s Manual
October 2004                                                                Plot–Assisted Setups



    FIR              Indicates the length of the impulse response of the matched FIR filter.
                     See description on Page 4–7.
    BW               Indicates the actual 3dB bandwidth of the matched filter. This is the
                     complete width of the passband from the lower frequency edge to
                     upper frequency edge. Note that the filter’s center frequency is fixed
                     at the radar’s intermediate frequency, as chosen in the “Mb” setup
                     command.
  DC-Gain            Indicates the filter’s response to DC (zero frequency) input. The value
                     is a negative number in decibels, or the word “ZERO” if the filter has
                     a true zero at DC. The filter’s DC gain should be kept at a minimum
                     so that fixed offsets in the A/D converters will not propagate into the
                     synthesized “I” and “Q” values.
   Freq              Indicates the mean frequency of the burst. See description on Page
                     4–8.
    Pwr              Indicates the average power in the full burst sample window. See
                     description on Page 4–8.
    Loss             The filter loss is a positive number in deciBels, and is only displayed
                     if the overall burst power exceeds the minimum valid burst threshold
                     set in the Mb command (clearly, it would not be possible to compute
                     the filter loss when the burst waveform is missing). The filter loss is
                     discussed further in Section 4.4.4.
    AFC              Indicates the level and status of the AFC voltage at the RVP8/IFD
                     module. The number is the present output level in D-Units ranging
                     from –100 to +100. The shorter “%” symbol is used since percentage
                     units correspond in a natural way to the D-Units.
                     An additional number in square brackets will be printed to the right of
                     the AFC level to show the encoded bit pattern which corresponds to
                     that level. This will only appear when the RVP8 deduces that a special
                     digital format is being used, i.e., when the backpanel phase-out lines
                     have been configured for AFC, or when any of the following are not
                     true: a) the low and high numeric AFC span is –32768 to +32767, b)
                     the uplink is enabled, c) the uplink format is binary, and d) pinmap
                     protocol is OFF. Binary format is printed in base-10, BCD format is
                     printed in Hex, and 8B4D format is printed with the low 16-bits (four
                     BCD digits) in Hex and the upper bits in base-10.
                     The AFC mode is shown to the right of the numerical value(s), and
                     can take on the following states.
                     (Disabled)       Indicates that neither AFC nor MFC are enabled. The
                                      output voltage remains fixed at 0% (center of its range).
                     (Manual)         Manual Frequency Control (MFC) is overriding AFC.
                                      The “U” and “D” commands can be used to slew the
                                      voltage up and down.
                     Whenever any of the following four states appears, it implies that AFC
                     is enabled and that MFC is disabled.


                                          4–15


RVP8 User’s Manual
October 2004                                                                     Plot–Assisted Setups



                          (NoBurst)       The energy in the burst is below the minimum energy
                                          threshold for a valid pulse (See Page 3–25). The AFC
                                          loop remains idle.
                          (Wait)          The burst pulse has become valid just recently, but the
                                          AFC loop is idle until the transmitter stabilizes (See
                                          Page 3–26)
                          (Track)         The burst pulse is valid, and the AFC loop is tracking
                                          in order to bring the burst frequency within the inner
                                          hysteresis limits.
                          (Locked)        The burst pulse is valid and the AFC loop is locked.
                                          The burst frequency is now within the outer hysteresis
                                          limits and has previously been within the inner limits
                                          while tracking. This is the stable operational mode in
                                          which data acquisition should take place.

4.4.4 Computation of Filter Loss
The Ps printout displays the power loss (calibration error) that results when the given filter is
applied to the given transmit burst waveform. This allows you to correct for the difference
between what a broad-band power meter measures as the overall transmit power, and what the
RVP8 narrow-band receiver will detect within its passband. The filter loss is a subtle quantity
that depends on the combined characteristics of both the transmit waveform and the receiver
matched filter.
The filter loss is zero if the burst waveform consists of a pure sinusoid at the designated
intermediate frequency. It is also very near zero as long as most of the burst energy is confined
within the passband of the RVP8’s filter. The filter loss will increase as the bandwidth of the
burst waveform increases and begins to spill out of that passband. Typical losses for a
well-matched filter are in the 0.5–1.8dB range, depending on the FIR length and other design
criteria.
As an example, consider how the RVP8 filters would respond to a simple rectangular pulse of
energy lasting T o seconds. For this discussion we can ignore the sinusoidal IF carrier that must
also be present within the pulse, and just focus on the rectangular envelope. This is valid
because the signal bandwidth, and hence the filter loss, is determined entirely by the shape of the
modulation envelope. For a pulse of length T o to have unit-energy it must have an amplitude of
1ń ǸT o . By centering this pulse at time zero the power spectrum is easily computed using a
real-valued integral:
                                                          2
                             ȡ T ń2                       ȣ
                                   ŕ
                                    o

                                                              sin2( p f T o )
                       S(f) +ȧ
                             ȧ
                                      1   cos( 2p f t )dt ȧ
                                                          ȧ +
                                     ǸT o                        p2 f2 To
                             Ȣ –T ń2
                                   o                      Ȥ
where f is the frequency in Hertz. This is the familiar “synch” function, whose main frequency
lobe extends from –1ńT o to 1ńT o Hertz, and whose total power integrated over all frequencies
is 1.0.


                                                4–16


RVP8 User’s Manual
October 2004                                                                        Plot–Assisted Setups



We can now examine what the filter loss (dB loss ) would be if this pulse were applied to a
bandpass filter. The filter loss is simply the ratio of the power that is passed by the filter, divided
by the total input power (1.0 in this case). Assume for the moment that the filter is an ideal
bandpass filter centered at zero Hertz (corresponding to how S(f) was defined) and having a
bandwidth B w , then:

                                                       ȡ B ń2          ȣ
                                                          ŕ
                                                           w


                                   dB loss + –10 log 10ȧ
                                                       ȧ       S(f) df ȧ
                                                                       ȧ
                                                       Ȣ –B ń2
                                                          w            Ȥ
This integral can be computed for a few “interesting” filter bandwidths, yielding filter losses of
0.44dB, 1.11dB, and 3.31dB when B w is 2ńT o , 1ńT o , and 1ń2T o respectively. These three
example bandwidths correspond to filters that pass the entire main frequency lobe, half of that
lobe, and one quarter of it.
You can experimentally verify these results using the RVP8 as follows:
   S       Using the Mt0 command, setup a T o + 0.5 msec trigger pulse from the RVP8 in the
           vicinity of range zero, and use that trigger to gate a signal generator whose output is
           applied to the RVP8/IFD Burst Input. Also setup 125-meter range resolution, and a
           rather long 6.0 msec impulse response length. The long length will make the transition
           edges of the matched filter as steep as possible, so that it becomes a reasonably good
           approximation to the ideal bandpass filter used in the above analysis.
   S       Use the Pb command to verify that the burst pulse is present, and position the triggers
           left and right until the pulse is centered exactly at zero.
   S       Use the Ps command to examine the frequency spectrum of the pulse. You should see a
           main energy lobe that is 4MHz wide and centered at the radar’s IF. There should also be
           weaker lobes spaced 2MHz apart on both sides of the main lobe. If the lobe spacing does
           not look quite right, it may be because the signal generator has slightly shortened or
           lengthened the trigger gate.
   S       Continue using Ps to examine filters that are 4MHz, 2MHz, and 1MHz wide at their 3dB
           points. You should see filter losses reported that are very close to the theoretical values
           for the ideal bandpass filter.
In the above analysis we have assumed that S(f) is the idealized power spectrum of a continuous
time signal. Of course, the RVP8 filter loss algorithm can only work from an estimate of S(f)
that is obtained from a finite number of samples. The filter loss calculation thus becomes more
complicated than the above example in which we integrated an idealized filter response over an
idealized power spectrum.
       ^
Let B(f) denote the estimated power spectrum of the continuous-time Tx burst waveform, for
which we have only a finite number of discrete samples {b n} . For purposes of this discussion
                                                                              ^
we can assume that the frequency variable f is continuous. Furthermore, let C(f) denote a
power spectrum estimate that is derived in an identical manner using the same number of


                                                   4–17


RVP8 User’s Manual
October 2004                                                                         Plot–Assisted Setups


                                                                                 ^
samples, but of a pure sine wave at the radar’s IF. The RVP8 determines B(f) according to its
                                                                             ^
sampled measurement of the transmitted waveform; however it can calculate C(f) internally
based on an idealized sinusoid. The reported filter loss is then:
                                      ȡ
                                      ȧ
                                          ŕ |H(f)| B(f) df
                                                    2 ^          ŕ |H(f)| C(f) df ȣȧ
                                                                           2 ^

                  dB loss + –10 log 10ȧ
                                      ȧ                      B                     ȧ
                                                                                   ȧ
                                      ȧ
                                      Ȣ
                                             ŕ B(f) df
                                                ^
                                                                    ŕ C(f) df ȧȤ
                                                                       ^




Where |H(f)| 2 is the spectral response of the RVP8 IF filter, and the integrals are performed over
the Nyquist frequency band that is implied by the RVP8/IFD sampling rate. Note that the two
                      ^
integrals involving C(f) will have constant value and need only be computed once. They serve
                   ^
to normalize the B(f) integrals in such a way that the filter loss evaluates to 0dB whenever the
transmit burst is a pure tone at IF.
This normalization is necessary for the filter loss values to be meaningful. Regardless of the
bandwidth and center frequency of H(f) , the filter loss should be reported as 0dB whenever the
Tx waveform appears to have zero spectral width, i.e., is indistinguishable from a pure IF
sinusoid. Of course, the real Tx waveform has only finite duration, and thus should never look
like a pure tone as long as the RVP8 is able to “see” the entire Tx envelope. For this reason, it is
important that the filter’s impulse response length be set long enough (using the Pb plot) to
insure that all of the details of the Tx waveform are being captured. If the entire Tx envelope
does not fit within the FIR filter, then the filter loss will be underestimated because the Tx
spectrum will appear to be narrower than it really is.
The RVP8’s calculation of digital filter loss is very similar to how the loss of an analog filter
would be measured on a test bench. Suppose we are given an analog bandpass filter and are
asked to determine its spectral loss when a given waveform is presented. We could use a power
meter to measure the waveform power before and after the filter is inserted, and compute the
ratio of these two numbers. This corresponds to the first integral ratio in the above equation.
However, this is not by itself an accurate measure of filter loss because it does not take into
account the bandwidth-independent insertion loss. Put another way, a flat 3dB pad would seem
to produce a 3dB filter loss in the above measurement, but that is certainly not the result that we
desire. The remedy is to make a second pair of power measurements of the filter’s response to a
CW tone at the passband center. This serves to calibrate the gain of the filter, and allows us to
compute a filter loss that captures the effects of spectral shape independent of overall gain. This
normalization step corresponds to the second integral ratio in the above equation.
If your radar calibration was performed using CW waveforms, then the reported filter loss
should either be added to the receiver calibration losses, or subtracted from the effective transmit
power; the net result being that dBZ0 will increase slightly.
In dual-receiver systems the filter loss is computed for the primary and secondary channels using
only the portion of bandwidth that is allocated to that channel. For example, if the two IFs are
24MHz and 30MHz, then the filter losses for each channel would use the frequency intervals
21–27MHz and 27–33MHz respectively. This is necessary to avoid picking up energy from the


                                                    4–18


RVP8 User’s Manual
October 2004                                                                   Plot–Assisted Setups



other receiver and interpreting it as out-of-band input power. A consequence, however, is that
the real out-of-band power is underestimated, i.e., the filter loss itself is underestimated. We
recommend temporarily switching dual-receiver systems back to single-receiver mode when the
filter loss is being measured. This is easily done by changing the Mc setup question back to
“single”, and disconnecting the secondary burst input to the RVP8/IFD.


4.4.5 Recommended Adjustment Procedures
The Ps command should be used only after the burst pulse has been successfully captured by
way of the Pb command. Use the <space> key to display the burst spectrum plot by itself, and
use the “Z” key to shift the entire graph into view. You are now looking at the actual frequency
content of the transmitted pulse. The plot should show a clean main power lobe centered at the
receiver’s intermediate frequency. Check the spectrum for spurious harmonics, excessive width,
and other out-of-band noise. Make any adjustments in the transmitter that might give a sharper
main lobe or reduced spurious noise.
Once we know the power spectrum of the transmitted pulse we can begin designing the matched
FIR filter. Use the <space> key to display both the filter response and the burst spectrum on the
same plot. Use the “Z” key to shift the burst’s main lobe up to the top horizontal line of the
graph. This makes it level with the filter’s peak lobe, which is always drawn tangent to the same
top line.




           Figure 4–4: Example of a Poorly Matched Filter


                                              4–19


RVP8 User’s Manual
October 2004                                                                      Plot–Assisted Setups



Begin with the FIR length that was chosen previously in the Pb command, and use the “N” and
“W” keys to set an initial bandwidth equal to the reciprocal of the pulsewidth. The main lobes
of the two plots should more-or-less overlap. Experiment with changing the FIR length and
bandwidth to achieve a filter with the following properties.

   S   The filter width should be no greater than the burst spectral width. A wider passband
       will reduce the SNR of the received signal because out-of-band noise would be allowed
       to pass.

   S   The DC gain should be as small as possible, preferably less than –64dB (See discussion
       below).

   S   If there are conspicuous interference spikes at particular frequencies, try to adjust the
       location of the filter’s zeros so that the interference is maximally attenuated.

The filter should not pass any frequencies that do not actually contain useful information from
the original transmitted pulse. If anything, choose a filter whose width is slightly narrower than
the burst’s spectral width. Figure 4–4 shows an example of a filter that is poorly matched to the
pulse. Although the filter has fairly good DC rejection, it passes frequencies that are outside of
the transmitter’s broadcast range. These frequencies contribute nothing but noise to the
synthesized “I” and “Q” data stream.

There are two procedures for optimizing the performance of the FIR filter:

   S   Manual Method –– The process of arriving at a nearly optimal filter will require a few
       minutes of hunting with the “I”, “W”, and “N” keys. Every time you press any of these
       keys the RVP8 designs a new FIR filter from scratch, and displays the results.
       Fortunately, the DSP chips are fast enough that this can be done quickly and
       interactively. Even though the user must still control two degrees of freedom (length and
       bandwidth), the RVP8’s internal design calculations are actually performing several
       hundred iterative steps each time, which preferentially select for the best filter. Because
       the FIR coefficients are quantized in the filter chips themselves, the process of finding an
       optimal filter becomes quite nonlinear.

   S   Automatic Method –– Simply type the “$” command and let the RVP8 do all of the
       work (See description in Section 4.4.2).

The offset error of the RVP8/IFD’s A/D converter is at most 10mV, i.e., –27dBm into its 50W
input. If we wish to achieve 85-dB of dynamic range below the converter’s +4dBm saturation
level, then we expect usable “I” and “Q” values to be obtainable from a (sub-LSB) input signal
at –81dBm. This is 54dB below the interference that would result from the worst-case A/D
offset. But a weak input signal at –81dBm would still be damaged by even an equal level of DC
interference. Therefore, adding another 10dB safety margin, we get –64dB as the recommended
maximum DC gain of the matched filter. This DC gain should be reduced even further if it is
known that coherent leakage is present in the receive signal at a level greater than the –27dBm
worse-case A/D offset.


                                                4–20


RVP8 User’s Manual
October 2004                                                                   Plot–Assisted Setups



Figure 4–5 shows a 60MHz filter with particularly poor (–42dB) DC rejection. The frequency
range of the plot is 36–72MHz; hence, DC appears aliased at the right edge and we can see a
peak in the filter’s stopband at DC. Contrast this with the filter shown in Figure 4–3 that has a
true zero at DC. In general, a poor filter can be converted into a “nearby” good filter by making
only incremental changes to the impulse response length and/or desired bandwidth.




           Figure 4–5: Example of a Filter With Poor DC Rejection




                                               4–21


RVP8 User’s Manual
October 2004                                                                     Plot–Assisted Setups



4.5 Pr — Plot Receiver Waveforms
The “Pb” and “Ps” commands described in the previous sections have been used to analyze the
signal that is applied to the “Burst-In” connector of the RVP8/IFD receiver module. The task
that remains is to checkout the actual received signal that is connected to “IF-In”. The goal is to
verify that the received signal is clean and appropriately scaled, and that nearby targets can be
seen clearly. The “Pr” command is used to make these measurements.

4.5.1 Interpreting the Receiver Waveform Plots
An example of a plot from the Pr command is shown in Figure 4–6. The horizontal axis
represents time (range) starting from a selectable offset and spanning a selectable interval. The
data are acquired from a single transmitted pulse, are are plotted both as raw IF samples and as
the LOG of the detected power using the FIR filter for the current pulsewidth.




        Figure 4–6: Example of Combined IF Sample and LOG Plot

The IF samples are plotted on a linear scale as signed quantities, with zero appearing at the
center line of the scope. Any DC offset that may be present in the A/D converter is not
removed, and will be seen as a shift in the baseline at higher zoom levels. For example, the
converter’s worst case DC offset of 10mv would appear as a 91-count offset in the 12-bit range
spanning –2048 to +2047. At the x32 or higher zoom scales, this offset would peg the sample
plot off scale. Typically the DC offset will be much less than this worst case value; but the
RVP8 preserves the DC term in the Pr sample plot so that its presence is not forgotten.
The “AC” amplitude of the IF samples will increase wherever targets are present. On top of
these samples is drawn the detected power on a logarithmic scale. Each horizontal line
represents a 10dB change in power. The graph is scaled so that the LOG power reaches the top
display line when the samples occupy the full amplitude span. Using Figure 4–6 as an example,


                                                4–22


RVP8 User’s Manual
October 2004                                                                       Plot–Assisted Setups



the two equal-power targets just to the left of center are approximately 18dB down from the top.
The amplitude of the samples is thus 10 (*18ń20) + 0.13 , i.e., 13% of full scale. This
correspondence between the LOG scale and the amplitude scale applies regardless of the plot’s
zoom level. As the IF samples are zoomed up and down by factors of two, the LOG plot will
shift up and down in 6dB steps.
The LOG plot is obtained by convoluting the FIR filter coefficients with the raw IF data
samples, and then plotting log(I 2 ) Q 2) at each possible offset along the sampling interval.
This convolution produces only (1 + N – I) output points, where N is the number of sample
points and I is the length of the FIR filter. For this reason the LOG plot begins approximately
I/2 samples from left side and ends approximately I/2 samples from the right.
The LOG points are computed at each possible offset within the raw IF samples. At the nominal
72MHz sampling rate the spacing between LOG samples will be a mere 4.17 meters. Thus, the
LOG plot gives a very detailed view of received power versus range. Of course, successive
LOG points will be highly correlated because successive input data intervals differ by only one
sample point. This is why the LOG plots appear smooth compared to the instantaneous variation
of the raw IF samples.
As the starting offset of the Pr plot is decreased to range zero you will begin to see part of the
burst pulse (the second half of it) appear at the left edge of the plot. This is because the burst
data samples are multiplexed onto the same fiber cable that carries the IF data samples. Zero
range is defined to occur at the center of the burst window; hence, the later half of the burst
pulse will be visible when the plot begins at range zero.
A second type of Pr display is shown in Figure 4–7. This plot shows a frequency spectrum of
the received data samples in a format that is nearly identical to the Ps display. The horizontal
axis represents the same band of frequencies (half the sampling rate), and the vertical axis
represents power in 10dB steps. The entire vertical axis is used so that an overall span of 80dB
is visible. This particular plot was made with the time span set to 50 msec, and with a 1-meter
antenna attached to the IF input so that a broad range of signals (radio stations, electrical noise,
etc.) would be detected.
The purpose of the Pr power spectrum is to check for spurious interference in the IF signal from
the radar receiver. The spectrum should be viewed with the transmitter turned off, and with the
starting range moved out so that the burst samples are not mixed in with the receiver data. The
power spectrum is computed using the complete interval of raw IF samples which, depending on
the chosen time span, may contain many hundreds of points. The frequency resolution of the Pr
spectrum can therefore be quite fine; making it possible to discern any interfering frequencies
with some detail.




                                                 4–23


RVP8 User’s Manual
October 2004                                                                  Plot–Assisted Setups




           Figure 4–7: Example of a Noisy High Resolution “Pr” Spectrum
The Pr spectrum plot will properly show a 0-Hz peak from any DC offset in the A/D converter,
and is thus consistent with how the DC offset is presented in the Pr sample plot. Both of these
plots preserve the DC component of the IF samples so that it can be monitored as part of the
routine maintenance of the receiver system. This is one of the few places in the RVP8 menus
and processing algorithms where the DC term deliberately remains intact.

4.5.2 Available Subcommands Within “Pr”
The list of subcommands is printed on the TTY:
Available Subcommands within ’Pr’:
  L/l & R/r Start range Left/Right
     T/t     Plot time span Up/Dn
     V/v     Number of spectra averaged
     Z/z     Amplitude zoom
   <space>   Alternate Plots
      %      Toggle between dual receivers
      .      Single Step
These subcommands change the start time and span of the IF sampling window, and alter the
format of the display.
  L/l & R/r              The “L” and “R” commands shift left and right the starting point of
                         the window of IF samples. The lower case commands shift in 0.25
                         msec steps, and the upper case commands use 10 msec steps. The


                                              4–24


RVP8 User’s Manual
October 2004                                                                 Plot–Assisted Setups



                        starting point is displayed both in microseconds and kilometers on the
                        TTY, and is not allowed to be set earlier than range zero.
    T/t                 The “T” command increments or decrements the time duration of the
                        window of IF samples. The window is not allowed to become shorter
                        than the impulse response length of the FIR filter, since that would
                        preclude calculating even a single LOG power point. The value is
                        reported in microseconds on the TTY, and the largest permitted span is
                        50 msec.
    V/v                 The “V” command increments or decrements the number of power
                        spectra that are averaged together to create the plot. The count ranges
                        from one (no averaging) to 25, and is reported on the TTY as “Navg”.
    Z/z                 The “Z” command zooms the amplitude of the IF samples by factors
                        of two from one to 128. The LOG plots are shifted in corresponding
                        6dB increments as the amplitude is zoomed up and down. The zoom
                        level is reported on the TTY so that absolute power levels and A/D
                        usage can be assessed.
  <space>               The space bar alternates among three choices for the type of data that
                        are plotted: 1) Received Samples, 2) Received Samples and LOG
                        Power, and 3) Received Power Spectrum.
      %                 In dual-receiver mode, the “%” command toggles between each
                        receiver. The printed status line is prefixed with ”Rx:Pri” or ”Rx:Sec”
                        according to which receiver is selected. Specifically, typing “%” will
                        toggle the LOG plot of the received power, and the printout of the
                        “Total”, “Filtered”, and “Midpoint” powers. However, the plots of
                        power spectra and raw IF data samples are always based on the sum of
                        all input signals, and thus do not change with “%”.

4.5.3 TTY Information Lines Within “Pr”
The TTY information lines will resemble:
Zoom:x1, Navg:4, Start:0.00 usec (0.00 km), Span:5 usec
Total:–63.3 dBm, Filtered:–77.6 dBm, MidSamp:–77.4 dBm
  Zoom           Indicates the magnification (in amplitude) of the plotted samples. A
                 zoom level of “x1” means that a full scale A/D waveform exactly fills
                 the vertical height of the plot. Generally, the IF signal strength will
                 not be quite this high. Thus, use larger zoom levels to see the weaker
                 samples more clearly. You may zoom in powers of two up to x128.
  Navg           Indicates the number of spectra and/or LOG powers that are averaged
                 together prior to plotting. Larger amounts of averaging increase the
                 ability to observe subtleties of the signals, but the display will update
                 more slowly.
  Start          Indicates the starting time of the IF sample window relative to range
                 zero. The time is shown both in microseconds and in kilometers.
  Span           Indicates the time span of the IF sample window in microseconds.


                                            4–25


RVP8 User’s Manual
October 2004                                                                     Plot–Assisted Setups



   Total                  Indicates the total RMS power that is being detected by the IF-Input
                          A/D converters. This total is computed using all of the raw IF samples
                          in the chosen interval, and is the sum of power at all frequencies other
                          than 0 Hz (and its aliases).
  Filtered                Indicates the RMS power that falls only within the passband of the
                          FIR filter for the current pulsewidth. This is computed using all of the
                          raw IF samples in the chosen interval.
  MidSamp                 Also indicates the RMS power within the passband of the FIR filter,
                          but using only the raw IF samples in the exact center of the chosen
                          interval.
The computation of “Total Power” is performed using the same subset of central IF samples that
are used to compute “Filtered Power”. This smaller subset of IF samples comes about because
filtering the data requires a convolution with the current FIR filter, and this computation does
not produce results all the way to the edges of the input data. This is the same reason that the
LOG plots do not extend across the full screen.
Because of this definition, it is valid to intercompare the “Total Power” and “Filtered Power”.
The two numbers will match exactly as long as all of the incoming power falls within the
passband of the FIR filter. The difference between the two powers can be used as a measure of
the “filter loss” for a given pulse shape, i.e., the portion of signal that is lost outside of the
filter’s passband.
             Note: The “Total”, “Filtered”, and “MidSamp” values represent true RMS
             power (i.e., variance), and not merely a sum-of-squares. Thus, any DC offset
             present in the A/D converter will not affect these power levels.




                                                4–26


RVP8 User’s Manual
October 2004                                                                   Plot–Assisted Setups



4.6 Pa — Plot Tx Waveform Ambiguity
With the introduction of the RVP8/Tx Digital Transmitter PCI Card it is now possible for the
RVP8 to make radar observations using compressed pulse waveforms. This opens up many new
opportunities within the weather radar community for using low-power solid-state transmitters
that employ very long pulse lengths (20–80μsec) . Transmitters of this kind are less expensive,
both to build and to maintain, compared with traditional Magnetron or Klystron systems.
However, the signal processing and waveform design that are required to make good use of these
long transmit pulses is also much more complex. To help with this, the RVP8 provides the Pa
(Plot Ambiguity) command in which compressed transmit waveforms can be designed, studied,
and optimized. Within the Pa plots you can experiment with different waveform designs, try out
various bandwidth and pulsewidth options, and examine and optimize the range/time sidelobes
of your waveform.


4.6.1 Interpreting the Ambiguity Plots
Figure 4–8 shows one form of Pa plot in which the magnitude of the Tx/Rx range sidelobes are
drawn on a log scale having 10dB vertical ticks. The horizontal span of the plot is equal to the
length of the pulse, and consequently, only half of the complete ambiguity diagram is shown.
This was done to make the plots more viewable; and no information lost since the zero-Doppler
response (white plot) can safely be assumed to be symmetric. In this example the pulsewidth is
30μsec, bandwidth is 3MHz, PSL is –61.2dB and ISL is –50.8dB, Doppler shift +/– 50 KHz.




           Figure 4–8: Ambiguity Diagram of a Compressed Tx Pulse


                                              4–27


RVP8 User’s Manual
October 2004                                                                    Plot–Assisted Setups



Also shown in yellow and green are the Tx/Rx responses when the overall waveform is modified
by a 50KHz target Doppler shift. Real weather targets would never have such a large Doppler
component, but the Pa menu allows you to study its effect anyway.
An alternate form of Pa plot of the same Tx waveform is shown in Figure 4–9. The horizontal
axis again represents time, but now spans the entire duration of the pulse. Three different plots
are drawn, hence the vertical axis is interpreted differently in each case:
   S   The instantaneous frequency across the full length of the pulse is shown in white. The
       vertical scale is normalized to hold the overall frequency span, which is also shown
       numerically in the Pa TTY output.
   S   The waveform baseband phase is shown in green, and is normalized so that the vertical
       axis holds the full span of values. Note that the phase, which generally spans a few
       thousand degrees, is “unwound” in this plot so that you can see its behavior nicely.
   S   The amplitude of the Tx waveform envelope is shown in yellow. It is drawn using a
       linear vertical scale which occupies only the middle half of the plot. This is to avoid
       creating too much “plotting clutter” in the corners.




Figure 4–9: Frequency, Phase and Amplitude of a Compressed Tx Pulse
From Figure 4–9 we can see that the waveform consists of a linear FM chirp that occupies about
87% of the central pulse duration. The frequency remains nearly constant in the leading and
trailing edges, hence the overall label “Non-Linear FM”. The central chirp is contained within a
somewhat larger amplitude modulation envelope that applies full scale power within the middle
82% of the pulse, and also provides bandlimited shaping of the leading and trailing edges.


                                               4–28


RVP8 User’s Manual
October 2004                                                                 Plot–Assisted Setups



This waveform was designed using the “$” automatic search-and-optimize command in the Pa
menu. For a given pulse length and bandwidth of the Tx waveform, this command allows you to
try thousands of combinations of FM shape and amplitude shape, searching for the combination
that minimizes the sum of PSL and ISL (in dB). This gives the best overall waveform for
weather radar observations in which both the PSL and ISL are important.

4.6.2 Available Subcommands Within “Pa”
The list of subcommands is printed on the TTY:
Available Subcommands within ’Pa’:
  S/s & L/l Pulse Length Shorter/Longer
  N/n & W/w Bandwidth Narrower/Wider
    1/2/3    Select Tuning Parameter to Change
  D/d & U/u Selected Tuning parameter Down/Up
     V/v     Doppler Frequency Shift Up/Down
     Z/z     Amplitude Zoom
      $      Search for Optimal Waveform

These subcommands change the bandwidth, pulsewidth, and shaping parameters of the transmit
waveform, and alter the format of the display.
  S/s & L/l              The “Shorter” and “Longer” commands decrease or increase the time
                         duration (i.e., pulsewidth) of the transmitted pulse. The lower case
                         commands shift in 0.05 msec steps, while the upper case commands
                         use 1 msec steps.
  N/n & W/w              The “Narrower” and “Wider” commands decrease or increase the
                         bandwidth of the transmitted pulse. The lower case commands shift in
                         10KHz steps, while the upper case commands use 200KHz steps.
  1&2&3                  Typing one of these numbers chooses which of the three waveform
                         tuning parameters will be altered by the “D” and “U” keys.
  D/d & U/u              The “Down” and “Up” commands decrease or increase the waveform
                         tuning parameter that has been chosen by the most recent “1”, “2” or
                         “3” key. The lower case commands shift in 0.001 (dimensionless)
                         steps, while the upper case commands use 0.05 steps. Present values
                         of all three parameters will be printed each time a Down/Up key is
                         pressed, e.g.,:
                            Tuning parameters: 0.9000 1.0000 0.1770
                         Please see Section 3.2.5.1 for a description of how each of the tuning
                         parameters are used.
  V/v                    The “Velocity” command allows you to investigate how the overall
                         compressed pulse Tx/Rx system will respond to the the effects of
                         target Doppler shift. Frequency shifts as large as 100KHz can be
                         introduced in order to see their effect on the Range/Time sidelobes.
                         The Pa plot will show the effects of +V and –V shifts as green and
                         yellow plots in addition to the standard white (zero Doppler) plot.


                                             4–29


RVP8 User’s Manual
October 2004                                                                  Plot–Assisted Setups



  Z/z                   The dynamic range of the Pa sidelobe plot is 80dB. Usually this will
                        give plenty of room to examine the properties of the waveform. But
                        for very wide dynamic range pulses, you can shift the plot up/down in
                        10dB steps using these “Zoom” keys.
  $                     Designs an optimal compressed waveform. For a given pulsewidth
                        and bandwidth of the Tx waveform, this command allows you to try
                        many thousands of combinations of FM shape and amplitude shape,
                        searching for the one that minimizes the sum of PSL and ISL (in dB).
                        This gives the best overall waveform for weather radar observations in
                        which both the PSL and ISL are important.
                        The following dialog appears in response to the “$” command:
                          TuningParam #1 (0.9000) –– 1 Grid Point from 0.9000 to 0.9000
                          TuningParam #2 (1.0000) –– 1 Grid Point from 1.0000 to 1.0000
                          TuningParam #3 (0.1774) –– 1 Grid Point from 0.1774 to 0.1774
                        As the line is printed for each parameter, you may either accept the
                        default single grid point (no search), or enter a desired number of grid
                        search points followed by a span of values within which to search.
                        For example, typing:
                          200 .9 .95
                        will request that the parameter be searched using 200 evenly spaced
                        grid points lying between 0.9000 and 0.9500 inclusive. After all three
                        parameter spans have been entered, the RVP8 will begin searching for
                        the optimum waveform. Progress messages are printed on the TTY,
                        and the plot will update every time a better waveform is discovered.
                        In this way it is easy to tell whether the search is converging.
                        The process normally runs to completion on its own; but if the search
                        is taking too long, or you’ve changed your mind about which intervals
                        to search, typing “Q” will exit right away. In either case, the prompt:
                          Keep this waveform ? [Y]
                        will appear. Typing “Y” (or Enter) will keep the optimized tuning
                        parameters that were just discovered, overwriting whatever starting
                        values were originally there. Typing “N” will discard the search
                        results and return to the original settings, as if “$” had never been
                        typed.

4.6.3 TTY Information Lines Within “Pa”
The TTY information lines will resemble:
BW:3.40MHz PW:29.99usec PSL:–61.2dB                      ISL:–51.3dB
  TxLoss:0.5dB RxLoss:2.4dB

  BW                    Bandwidth of the Tx waveform in MegaHertz.
  PW                    Pulsewidth (pulse length) of the Tx waveform in microseconds.


                                             4–30


RVP8 User’s Manual
October 2004                                                                          Plot–Assisted Setups



  PSL                Peak Sidelobe Level of the ambiguity diagram, expressed in deciBels
                     relative to the main lobe level. This is the peak height of the strongest
                     range/time sidelobe, and measures the ability of the compressed pulse
                     to distinguish a given target from a small number of individual point
                     targets that also lie within the pulse volume. The waveform’s ability
                     to “see” between clutter targets is largely determined by the PSL level.
  ISL                Integrated Sidelobe Level of the ambiguity diagram, expressed in dB
                     relative to the main lobe. This is the total power in all range/time
                     sidelobes divided by the total power in the main lobe. ISL measures
                     the ability of the compressed pulse to distinguish a given target from
                     other distributed targets (such as rain) that also lie within the pulse
                     volume.
  TxLoss             The TxLoss is calculated as the total power in the transmit waveform
                     divided by the power that would be contained in an equal length ideal
                     rectangular pulse. It is a measure of how much power does not get
                     transmitted due to the amplitude shaping of the synthesized waveform.
                     TxLoss should be included in the computation of the radar constant,
                     since the latter is based on a nominal pulsewidth equal to the overall
                     length of the entire Tx waveform (including the amplitude tapering).
  RxLoss             The RxLoss is a measure of how much information is “thrown away”
                     by the receiving filter in order to achieve the desired level of sidelobe
                     suppression. These two quantities often trade off against each other in
                     receiver systems, so that optimum range/time sidelobes can only be
                     achieved at the expense of a few deciBels of loss of sensitivity. The
                     receiver filter loss is calculated as:

                                             ȡ
                                             ȧ
                                                      Ťŕ   T(t) R(t) dt       Ť   2
                                                                                         ȣ
                                                                                         ȧ
                         dB loss + –10 log 10ȧ
                                             ȧ
                                                                                         ȧ
                                                                                         ȧ
                                             ȧ
                                             Ȣ
                                                 ŕ | T(t) |   2   dt   ŕ   | R(t) | 2 dt
                                                                                         ȧ
                                                                                         Ȥ
                     Where T(t) is the complex-valued transmit waveform, and R(t) is the
                     complex-valued filter being used to receive it. When R(t) is designed
                     to be the complex conjugate of T(t), we have the ideal matched filter
                     case whose receive loss is 0dB. However, this matched filter has
                     rather poor sidelobe behavior that makes it unsuitable for use directly
                     in the receiver. Instead, a windowed version (Hamming, Blackman,
                     etc.) of the ideal matched filter is used to achieve the desired sidelobe
                     levels. Of course, that windowing operation also has the effect of
                     discarding some valid information in the leading and trailing portions
                     of the pulse. Hence, there is a loss in receive sensitivity whenever a
                     window is applied.
                     Note: Given a compressed transmit waveform, the RVP8 designs the
                     appropriate “mismatch” Rx filter automatically, using an optimized
                     Blackman window in all cases. Code developers can also access the


                                          4–31


RVP8 User’s Manual
October 2004                                                                    Plot–Assisted Setups



                          internal APIs directly to design any desired transmit waveform along
                          with the associated FIR filter to receive it.

4.6.4 Bench Testing of Compressed Waveforms
Working with compressed pulse waveforms can be tricky, so it is reassuring to run some simple
bench tests to verify that things are working properly. Once the Tx waveform has been designed
it can be injected into the IFD for testing with the Pr command. This not only verifies that the
analog waveform is generated properly, but also that the matched filtering on the RVP8/Rx card
is able to deconvolve the compressed information.
To setup the test, simply connect the Channel #1 or Channel #2 output of the RVP8/Tx card to
the IF-Input of the IFD. Use whichever RVP8/Tx channel has been configured for waveform
synthesis in the Mz menu, and set the Zero Offset of the Transmitter Pulse in the Mt<n> menu
to, perhaps, 50μsec. The latter step will shift the waveform out in range so that the Pr plot is
able to see it.




           Figure 4–10: IFD Sampling of Optimized Compressed Tx Waveform
Figure 4–10 shows an actual Pr plot of a 40μsec, 5MHz optimized waveform generated by the
RVP8/Tx card and fed into the IFD. In this example, the ideal Tx waveform has a Peak Sidelobe
Level (PSL) of –76.7dB and an Integrated Sidelobe Level (ISL) of –62.3dB. The measured
testbench performance is several dB short of this, probably because of the uncompensated analog
bandpass filters on the RVP8/Tx and IFD. These filters have several tenths of a dB of amplitude
ripple as well as minor deviations from linear phase within the 5MHz signal bandwidth. The
effect is that the sampled analog waveform is not quite identical to the ideal waveform.


                                               4–32


RVP8 User’s Manual
October 2004                                                                Plot–Assisted Setups



The Ps plotting command can also be used to examine the ideal transmit spectrum and actual
received spectrum of compressed pulses. An example is shown in Figure 4–11 below for a
60MHz, 40μsec linear FM pulse having a bandwidth of 2MHz. The energy in the pulse is both
sharply contained within and uniformly distributed over the 2MHz frequency interval centered
on the IF carrier. This demonstrates the ability of synthesized transmit waveforms to remain
cleanly within their allocated bounds.




           Figure 4–11: Ideal and Actual Linear-FM Spectrum Displayed in Ps Plot




                                             4–33



Document Created: 2006-06-12 11:42:50
Document Modified: 2006-06-12 11:42:50

© 2024 FCC.report