test report

FCC ID: NVI-KT9600K6B

Test Report

Download: PDF
FCCID_4476447

                                                                                               REPORT No.:SZ19050096W02




                                          TEST REPORT

                         APPLICANT                                 : dormakaba EAD GmbH

                         PRODUCT NAME                              : data collection terminal

                         MODEL NAME                                : 9600-K6 BLE

                         BRAND NAME                                : dormakaba

                         FCC ID                                    : NVI-KT9600K6B

                         STANDARD(S)                               : 47 CFR Part 15 Subpart C

                         RECEIPT DATE                              : 2019-05-20

                         TEST DATE                                 : 2019-06-22 to 2019-07-01

                         ISSUE DATE                                : 2019-07-09




                                                                        Edited by:
                                                                                               Zeng Xiaoying (Rapporteur)


                                                                        Approved by:
                                                                                               Peng Huarui ( Supervisor )



NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.

                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
 MORLAB
                                                                                               Tel: 86-755-36698555   Fax: 86-755-36698525
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                             Page 1 of 23


                                                                                       REPORT No.:SZ19050096W02


                                                     DIRECTORY
1. Technical Information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 4
1.1. Applicant and Manufacturer Information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 4
1.2. Equipment Under Test (EUT) Description ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 4
1.3. Test Standards and Results ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 5
1.4. Environmental Conditions ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 5
2. 47 CFR Part 15C Requirements ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 6
2.1. Antenna requirement ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 6
2.2. Conducted Emission ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 7
2.3. Radiated Emission ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 11
2.4. Frequency Tolerance ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 17
2.5. 20dB Bandwidth ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 19
Annex A Test Uncertainty ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 21
Annex B Testing Laboratory Information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 22




                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                       Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 2 0f 23


                                                                                 REPORT No.:SZ19050096W02

                                                     Change History
   Version                                Date                                     Reason for change
     1.0                            2019-07-09                                             First edition




           SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                 Tel: 86-755-36698555   Fax: 86-755-36698525
           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
           Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                               Page 3 0f 23


                                                                                            REPORT No.:SZ19050096W02

1. Technical Information
Note: Provide by applicant.


1.1. Applicant and Manufacturer Information

 Applicant:                              dormakaba EAD GmbH
 Applicant Address:                      Albertistr. 3, 78056 Villingen-Schwenningen, Germany
 Manufacturer:                           In-Tech Electronics Ltd
                                         Unit A,13/F, Wing Tai Centre,12 Hing Yip Street, Kwun Tong
 Manufacturer Address:
                                         Kowloon, Hong Kong


1.2. Equipment Under Test (EUT) Description

 Product Name:                          data collection terminal
 Serial No:                             (N/A, marked #1 by test site)
 Hardware Version:                      02
 Software Version:                      V5
 Operating Frequency:                   13.56MHz
 Modulation Type:                       ASK
 Antenna Type:                          PCB Antenna
                                        Battery
                                        Brand Name:                                   Renata
                                        Model No.:                                    CR2450N
 Accessory Information:                 Serial No.:                                   (N/A, marked #1 by test site)
                                        Capacity:                                     540mAh
                                        Rated Voltage:                                3.0V
                                        Charge Limit:                                 N/A
Note 1:This test report is updated from the original report (Report No.: SZ19050100W03, FCC ID:
NVI-KT9600K6BWL), based on the similarity between before, the RFID+BT module which was
fixed on the motherboard is the same, only difference is that the WIFI module has been pulled out
on the motherboard. The changes do not affect the results in this report.
Note 2: For a more detailed description, please refer to Specification or User’s Manual supplied by
the applicant and/or manufacturer.




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                             Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China          Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                           Page 4 0f 23


                                                                                          REPORT No.:SZ19050096W02

1.3. Test Standards and Results

The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C for the EUT
FCC ID Certification:
 No.     Identity                                                       Document Title

 1       47 CFR Part 15 (10-1-15 Edition)                               Radio Frequency Devices

Test detailed items/section required by FCC rules and results are as below:
  No.    Section                      Description                                   Test Date             Test Engineer                  Result
     1   15.203                       Antenna Requirement                               N/A                          N/A              PASSNote1
     2   15.207                       Conducted Emission                         Aug 21, 2017              Peng Xuewei                PASSNote1
         15.209
     3   15.225(a)(b)                 Radiated Emission                          Jun 22, 2019              Peng Xuewei                PASSNote1
         (c)(d)
     4   15.225(e)                    Frequency Tolerance                         Jul 01, 2019             Peng Xuewei                PASSNote1
     5   15.215(c)                    20dB Bandwidth                             Jun 19, 2019              Peng Xuewei                PASSNote1
 Note1: The test results of these test items in this report refer to the test report (Report No.:
 SZ19050100W03).
 Note 2: The tests were performed according to the method of measurements prescribed in
 ANSI C63.10-2013. The EUT has been tested under continuous operating condition.



1.4. Environmental Conditions

During the measurement, the environmental conditions were within the listed ranges:

 Temperature (°C):                                              15 - 35
 Relative Humidity (%):                                         30 -60
 Atmospheric Pressure (kPa):                                    86-106




                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                              Tel: 86-755-36698555     Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China         Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                              Page 5 0f 23


                                                                                       REPORT No.:SZ19050096W02

2. 47 CFR Part 15C Requirements
2.1. Antenna requirement

2.1.1. Applicable Standard

According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other
than that furnished by the responsible party shall be used with the device. The use of a
permanently attached antenna or of an antenna that uses a unique coupling to the intentional
radiator shall be considered sufficient to comply with the provisions of this section.


2.1.2. Result:

The EUT has a permanently and irreplaceable attached antenna. Please refer to the EUT internal
photos.

Result: Compliant




                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                       Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 6 0f 23


                                                                                      REPORT No.:SZ19050096W02

2.2. Conducted Emission

2.2.1. Test Requirement

According to FCC section 15.207, the radio frequency voltage that is conducted back onto the AC
power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the
following table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).
 Frequency          range Conducted Limit (dBµV)
 (MHz)                            Quai-peak                                             Average
 0.15 - 0.50                      66 to 56                                              56 to 46
 0.50 - 5                         56                                                    46
 5 - 30                           60                                                    50
NOTE:
(a) The lower limit shall apply at the band edges.
(b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.


2.2.2. Test Setup




The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power
mains through a LISN which provides 50Ω/50µH of coupling impedance for the measuring
instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole
test system are calibrated to correct the reading.




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                      Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 7 0f 23


                                                                                    REPORT No.:SZ19050096W02

2.2.3. Test Result

The maximum conducted interference is searched using Peak (PK), if the emission levels more
than the AV and QP limits, and that have narrow margins from the AV and QP limits will be
re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power
mains connected to the EUT are performed. Refer to recorded points and plots below.
Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested
respectively, only the results of the worst case AC 120V/60Hz were recorded in this report.
A. Test setup:
Test Mode: EUT + Network Cable + Ethernet POE Switch +Adapter+RFID TX
Test voltage: AC 120V/60Hz
The measurement results are obtained as below:
E [dBμV] =UR + LCable loss [dB] + AFactor
UR: Receiver Reading
AFactor: Voltage division factor of LISN




              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                    Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 8 0f 23


                                                                                       REPORT No.:SZ19050096W02

B. Test Plots:




                                                                 (L Phase)

        Fre.          Emission Level (dBµV)                                     Limit (dBµV)
NO.                                                                                                            Power-line              Verdict
       (MHz)         Quai-peak                Average                 Quai-peak          Average
 1      0.15             31.00                   25.21                    66.00            56.00                                       PASS
 2     2.1858            31.36                   25.46                    56.00            46.00                                       PASS
 3     3.1678            33.71                   24.32                    56.00            46.00                                       PASS
                                                                                                                   Line
 4    10.3218            34.92                   33.23                    60.00            50.00                                       PASS
 5    13.5596            47.19                   47.10                    60.00            50.00                                       PASS
 6    21.3488            38.59                   33.12                    60.00            50.00                                       PASS




                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                        Tel: 86-755-36698555    Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                        Page 9 0f 23


                                                                                      REPORT No.:SZ19050096W02




                                                                (N Phase)

       Fre.          Emission Level (dBµV)                                     Limit (dBµV)
NO.                                                                                                           Power-line           Verdict
      (MHz)         Quai-peak                Average                 Quai-peak          Average
 1    0.1836            34.57                   28.73                    65.04            55.04                                       PASS
 2    1.3872            41.40                   35.71                    56.00            46.00                                       PASS
 3    3.9716            24.86                   18.87                    56.00            46.00                                       PASS
                                                                                                               Neutral
 4    10.4678           37.35                   22.99                    60.00            50.00                                       PASS
 5     13.56            48.75                   48.32                    60.00            50.00                                       PASS
 6    20.5016           35.93                   31.16                    60.00            50.00                                       PASS




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                       Tel: 86-755-36698555    Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                      Page 10 0f 23


                                                                                          REPORT No.:SZ19050096W02

2.3. Radiated Emission

2.3.1. Test Requirement

Radiated Emission <30MHz (9 kHz-30MHz, E-field)
According to FCC section 15.225, for <30MHz, Radiated emissions were measured according to
ANSIC63.4. The EUT was set to transmit at the highest output power. The EUT was set 30 meter
away from the measuring antenna. The loop antenna was positioned 1 meter above the ground
from the center of the loop. The measuring bandwidth was set to 10KHz. (Note: During testing the
receive antenna was rotated about its axis to maximize the emission from the EUT)
There was no detected Restricted bands and Radiated Spurious emission below 30MHz. The 30m
limit was converted to 3m Limit using square factor(x) as it was found by measurements as follows;
3 m Limit(dBuV/m) = 20log(X)+40log(30/3)= 20log(15848)+40log(30/3) = 124dBuV
Except as provided elsewhere in this Subpart, the emissions from an intentional radiator shall not
exceed the field strength levels specified in the following table:
                                                           Field Strength@30m                                     Field Strength@3m
 Frequency range (MHz)
                                                   µV/m                                dBµV/m                              dBµV/m
       Below 13.110                                  30                                  29.5                                 69.5
     13.110 ~ 13.410                                106                                  40.5                                 80.5
     13.410 ~ 13.553                                334                                  50.5                                 90.5
      13.553 ~13.567                              15.848                                  84                                  124
     13.567 ~ 13.710                                334                                  50.5                                 90.5
      13.710 ~14.010                                106                                  40.5                                 80.5
      Above 14.010                                   30                                  29.5                                 69.5
NOTE: a)     Field Strength (dBµV/m) = 20*log[Field Strength (µV/m)].
         b) In the emission tables above, the tighter limit applies at the band edges.
Radiated Emission >30MHz (30MHz-1GHz, E-field)
According to FCC section 15.205, the field strength of radiated emissions from intentional radiators
at a distance of 3 meters shall not exceed the following values:
                                                                                      Field Strength
  Frequency range (MHz)
                                                               µV/m                                               dBµV/m
           30 - 88                                              100                                                   40
           88 - 216                                             150                                                 43.5
         216 - 960                                              200                                                   46
         Above 960                                              500                                                   54
NOTE: a)     Field Strength (dBµV/m) = 20*log[Field Strength (µV/m)].
      b)     In the emission tables above, the tighter limit applies at the band edges.




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                           Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China        Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page 11 0f 23


                                                                                      REPORT No.:SZ19050096W02

2.3.2. Test Setup

1) For radiated emissions below 30MHz




2) For radiated emissions from 30MHz to1GHz




The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of
the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating
Turn Table, and keeps 3m away from the Test Antenna, which is mounted on a variable-height
antenna master tower.




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                      Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 12 0f 23


                                                                                       REPORT No.:SZ19050096W02

For the test Antenna:

In the frequency range of 9 kHz to 30MHz, magnetic field is measured with Loop Test Antenna.
The Test Antenna is positioned with its plane vertical at 1m distance from the EUT. The center of
the Loop Test Antenna is 1m above the ground. During the measurement the Loop Test Antenna
rotates about its vertical axis for maximum response at each azimuth about the EUT.

In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) was used. Test
Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground
to determine the maximum value of the field strength. The emission levels at both horizontal and
vertical polarizations should be tested.


2.3.3. Test Result

A. Radiated Emission <30MHz (1.075MHz-30MHz, E-field, opened)




 NO.     Frequency (MHz)                 Detector Type                    Level at 3m (dBV/m)                Limit at 3m (dBV/m)
  1           2.620                        Quasi Peak                             35.72                                69.5
  2           2.665                        Quasi Peak                                37.67                                69.5
  3           2.710                        Quasi Peak                                38.50                                69.5
  4           2.755                        Quasi Peak                                38.51                                69.5
  5           2.855                        Quasi Peak                                36.79                                69.5
  6           13.56                        Quasi Peak                                35.57                                 124




               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                       Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 13 0f 23


                                                                                     REPORT No.:SZ19050096W02

B. Radiated Emission <30MHz (1.075MHz-30MHz, E-field, closed)




NO.    Frequency (MHz)                 Detector Type                    Level at 3m (dBV/m)                Limit at 3m (dBV/m)
  1         2.665                        Quasi Peak                             36.76                                69.5
  2         2.715                        Quasi Peak                                37.68                                69.5
  3         2.760                        Quasi Peak                                38.52                                69.5
  4         2.805                        Quasi Peak                                37.68                                69.5
  5         2.855                        Quasi Peak                                37.70                                69.5
  6         13.555                       Quasi Peak                                33.07                                 124




             SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                     Tel: 86-755-36698555   Fax: 86-755-36698525
             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 14 0f 23


                                                                                      REPORT No.:SZ19050096W02

C. Radiated Emission >30MHz (30MHz-1GHz)




                                    (30MHz – 1GHz, Test Antenna Horizontal)

         Fre.             PK                QP               AV           Limit-PK    Limit-QP         Limit-AV
  No.                                                                                                                   ANT           Verdict
         MHz          dBµV/m            dBµV/m           dBµV/m            dBµV/m     dBµV/m            dBµV/m
   1    33.642           26.08             N/A               N/A              N/A      40.00                 N/A          H           PASS
   2    100.413          25.42             N/A               N/A              N/A      43.50                 N/A          H           PASS
   3    221.815          22.57             N/A               N/A              N/A      46.00                 N/A          H           PASS
   4    396.633          24.92             N/A               N/A              N/A      46.00                 N/A          H           PASS
   5    666.145          29.14             N/A               N/A              N/A      46.00                 N/A          H           PASS
   6    940.513          31.77             N/A               N/A              N/A      46.00                 N/A          H           PASS




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                      Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 15 0f 23


                                                                                       REPORT No.:SZ19050096W02




                                       (30MHz – 1GHz, Test Antenna Vertical)

 No.    Fre.              PK               QP                 AV           Limit-PK    Limit-QP         Limit-AV         ANT        Verdict
        MHz           dBµV/m            dBµV/m           dBµV/m             dBµV/m     dBµV/m            dBµV/m
  1    37.284           26.68              N/A               N/A               N/A      40.00                 N/A          V           PASS
  2    97.985           26.24              N/A               N/A               N/A      43.50                 N/A          V           PASS
  3    114.981          25.35              N/A               N/A               N/A      43.50                 N/A          V           PASS
  4    198.748          22.30              N/A               N/A               N/A      43.50                 N/A          V           PASS
  5    448.836          27.07              N/A               N/A               N/A      46.00                 N/A          V           PASS
  6    956.295          32.47              N/A               N/A               N/A      46.00                 N/A          V           PASS




                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                       Tel: 86-755-36698555     Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                       Page 16 0f 23


                                                                                        REPORT No.:SZ19050096W02

2.4. Frequency Tolerance

2.4.1. Test Requirement

According to FCC section 15.225, the devices operating in the 13.553~13.567 MHz shall maintain
the carrier frequency within 0.01% of the operating frequency over the temperature variation of
-20°C to +50°C using an environmental chamber. The primary supply voltage is varied from 85% to
115% of the voltage normally at the input to the device or at the power supply terminals if cables
are not normally supplied.


2.4.2. Test Setup


                                                                        Temperature Chamber




                                                                                  EUT                                DC Power
                                                                                                                      Supply




The EUT, which is powered by the DC Power Supply directly, is located in the Temperature
Chamber. The EUT was measured by transmitter mode continuously.




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                        Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                      Page 17 0f 23


                                                                                           REPORT No.:SZ19050096W02

2.4.3. Test Result

Operating Frequency: 13,560,000 Hz
Deference Voltage: 48V
Deviant Limit: ±0.01%
                             Test Conditions
 VOLTAGE (%)          Power              Temperature                     Fre. Dev. (Hz)                  Deviation (%)                Verdict
                      (VDC)                 (°C)
      100                                        -20                                 422                      0.00311
      100                                        -10                                 387                      0.00285
      100                                          0                                 376                      0.00277
      100                                        +10                                 381                      0.00281
      100                48                      +20                                 346                      0.00255
      100                                        +25                                 337                      0.00249                    PASS
      100                                        +30                                 374                      0.00276
      100                                        +40                                 395                      0.00291
      100                                        +50                                 445                      0.00328
      85               40.8                      +20                                 262                      0.00193
      115              55.2                      +20                                 304                      0.00224




               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                           Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China         Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page 18 0f 23


                                                                                     REPORT No.:SZ19050096W02

2.5. 20dB Bandwidth

2.5.1. Standard Applicable

According to FCC section 15.215(c), the 20dB bandwidth should be contained within the frequency
band designated in the rule section under which the EUT is operated, it was measured with a
spectrum analyzer connected the EUT while the EUT is operating in transmission mode.


2.5.2. Test Setup




               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                     Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 19 0f 23


                                                                                        REPORT No.:SZ19050096W02

2.5.3. Test Result

                                Measurement                                                         Limit
  Centre        20dB                                                                  20dB
                                          Frequency Range                                                  Frequency                  Verdict
Frequency     Bandwidth                                                             Bandwidth
                                               (MHz)                                                      Range(MHz)
                (kHz)                                                                 (kHz)
13.56MHz          1.92                   13.5589 to 13.5611                            14             13.553 to 13.567                 Pass




              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                        Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China       Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                      Page 20 0f 23


                                                                                    REPORT No.:SZ19050096W02

Annex A Test Uncertainty
The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
Uncertainty in Measurement" (GUM) published by ISO.

Radiated Emission:                                     ±3.1dB
Conducted Emission:                                    ±1.8dB
Bandwidth                                              ±5%
Frequency Tolerance                                    ±5%




              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                    Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 21 0f 23


                                                                                     REPORT No.:SZ19050096W02

Annex B Testing Laboratory Information
1. Identification of the Responsible Testing Laboratory

 Laboratory Name:                             Shenzhen Morlab Communications Technology Co., Ltd.
                                              Morlab Laboratory
 Laboratory Address:                          FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                              Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                              Province, P. R. China
 Telephone:                                   +86 755 36698555
 Facsimile:                                   +86 755 36698525

2. Identification of the Responsible Testing Location

                                               Shenzhen Morlab Communications Technology Co., Ltd.
 Name:
                                               Morlab Laboratory
                                               FL.3, Building A, FeiYang Science Park, No.8 LongChang
 Address:                                      Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                               Province, P. R. China

3. Facilities and Accreditations

All measurement facilities used to collect the measurement data are located at FL.3, Building A,
FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is
constructed in conformance with the requirements of ANSI C63.10-2013 and CISPR Publication 22;
the FCC designation number is CN1192, the test firm registration number is 226174.




               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                     Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 22 0f 23


                                                                                           REPORT No.:SZ19050096W02

4. Test Equipments Utilized

4.1 Test Equipments
   Description          Manufacturer                       Model                  Serial No.                Cal. Date                 Cal. Due
    Receiver               KEYSIGHT                      N9038A                MY56400093                  2019.05.08               2020.05.09
      LISN               Schwarzbeck                  NSLK 8127                        812744              2019.05.08               2020.05.09
  Pulse Limiter                                            VTSD
                         Schwarzbeck                                                    9391               2019.05.08               2020.05.09
     (20dB)                                               9561-D
     Coaxial
   cable(BNC)                  Morlab                     EMC01                        CB01                          N/A                  N/A
 (30MHz-26GHz)
    Receiver                   Agilent                   N9038A                MY54130016                  2018.08.04               2019.08.03
  Coaxial Cable                Morlab                     EMC02                        CB02                          N/A                  N/A
    Anechoic
                                 CRT                   9m*6m*6m                         N/A                2017.11.19               2020.11.18
    Chamber
 Test Antenna –
                         Schwarzbeck                  VULB 9163                    9163-519                2019.05.08               2020.05.09
     Bi-Log
  Test Antenna
                         Schwarzbeck                  FMZB 1519                    1519-022                2019.02.15               2020.02.14
     -Loop
                            Good Will
    DC Power
                           Instrument                        N/A                        N/A                2019.04.16               2020.04.15
     Supply
                             Co.,Ltd.
   Temperature
                               YOMA                         (N/A)                      (N/A)               2019.01.22               2020.01.21
    Chamber


4.2 Test Software Utilized
             Model                                           Version Number                                                Producer
        TS+ -[ JS32-CE]                                        Version 2.5.0.0                                             Tonscend
     MORLAB EMCR V1.2                                             Version 1.0                                              MORLAB


                                                          END OF REPORT




                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                              Tel: 86-755-36698555     Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China          Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                              Page 23 0f 23



Document Created: 2019-10-08 10:36:50
Document Modified: 2019-10-08 10:36:50

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC