Revised RF Exposure Statement

FCC ID: NS901P5

RF Exposure Info

Download: PDF
FCCID_141024

RF Exposure Calculations:

The following information provides the minimum separation distance for each of the
antennas provided with the MHX-920 module, as calculated from FCC OET 65
Appendix B, Table 1B Guidelines for General Population/Uncontrolled Exposure. This
calculation is based on the highest EIRP possible from the system, considering maximum
power and antenna gain. The formula used was:



S = (Po*G)/(4*pi*r^2)

                       Where S = 0.6 mW/cm^2 for 902.47 MHz

         Where Po = 100 mW for Yagi antennas (max. power set at factory)

     Where Po = 1.0 Watt for Omni antennas (max. power user configurable)



               For:   12 dB Yagi Antenna             r = 14 cm

                      2.5dB Omni Antenna             r = 15 cm

                      6 dB Omni Antenna              r = 23 cm




       The following statement will be presented in the MHX-920 User Manual:


                                          WARNING


In order to comply with the FCC/IC adopted RF exposure requirements, this transmitter
system will be installed by the manufacturer's reseller professional. Installation of all
antennas must be performed in a manner that will provide at least 23 cm clearance from
the front radiating aperture, to any user or member of the public