Test Report_rev.pdf

FCC ID: NRIWS27XX00

Test Report

Download: PDF

                                                               FCC Test Report

                       Report No.: RF190329D09

                            FCC ID: NRIWS27XX00

                       Test Model: LDD-700SW

                  Series Model: L(X)D-70(Y)SW, where X can be D or B, Y can be 0~2

                 Received Date: Apr. 01, 2019

                         Test Date: Apr. 08 to 12, 2019

                     Issued Date: Apr. 22, 2019


                         Applicant: IR-TEC International Ltd.

                           Address: 6 Rong An Road,Luzhu Taoyuan 33852, TAIWAN


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Hsin Chu Laboratory
                    Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                 Taiwan R.O.C.
            Test Location: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                           Taiwan R.O.C.
       FCC Registration /
                           723255 / TW2022
      Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to
us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such
notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report must not be
used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.
Report No.: RF190329D09                                               Page No. 1 / 30                                            Report Format Version: 6.1.1
Reference No.: 190329D09


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1         Certificate of Conformity...................................................................................................................... 4
2         Summary of Test Results ..................................................................................................................... 5
    2.1      Measurement Uncertainty ................................................................................................................... 5
    2.2      Modification Record ............................................................................................................................ 5
3         General Information .............................................................................................................................. 6
    3.1      General Description of EUT ................................................................................................................ 6
    3.2      Description of Test Modes ................................................................................................................... 7
    3.2.1    Test Mode Applicability and Tested Channel Detail............................................................................. 8
    3.3      Duty Cycle of Test Signal .................................................................................................................. 10
    3.4      Description of Support Units .............................................................................................................. 11
    3.4.1    Configuration of System under Test ................................................................................................... 11
    3.5      General Description of Applied Standards ........................................................................................ 12
4         Test Types and Results ...................................................................................................................... 13
    4.1      Radiated Emission and Bandedge Measurement............................................................................. 13
    4.1.1    Limits of Radiated Emission and Bandedge Measurement .............................................................. 13
    4.1.2    Test Instruments ................................................................................................................................ 14
    4.1.3    Test Procedures................................................................................................................................. 16
    4.1.4    Deviation from Test Standard ............................................................................................................ 16
    4.1.5    Test Setup .......................................................................................................................................... 17
    4.1.6    EUT Operating Conditions................................................................................................................. 18
    4.1.7    Test Results ....................................................................................................................................... 19
    4.2      Conducted Emission Measurement .................................................................................................. 23
    4.2.1    Limits of Conducted Emission Measurement .................................................................................... 23
    4.2.2    Test Instruments ................................................................................................................................ 23
    4.2.3    Test Procedures................................................................................................................................. 24
    4.2.4    Deviation from Test Standard ............................................................................................................ 24
    4.2.5    Test Setup .......................................................................................................................................... 24
    4.2.6    EUT Operating Conditions................................................................................................................. 24
    4.2.7    Test Results ....................................................................................................................................... 25
    4.3      20dB Bandwidth Measurement ......................................................................................................... 27
    4.3.1    Limits of 20dB bandwidth Measurement ........................................................................................... 27
    4.3.2    Test Instruments ................................................................................................................................ 27
    4.3.3    Test Procedures................................................................................................................................. 27
    4.3.4    Deviation from Test Standard ............................................................................................................ 27
    4.3.5    Test Setup .......................................................................................................................................... 27
    4.3.6    EUT Operating Conditions................................................................................................................. 27
    4.3.7    Test Results ....................................................................................................................................... 28
5         Pictures of Test Arrangements .......................................................................................................... 29
Appendix – Information of the Testing Laboratories ................................................................................. 30




Report No.: RF190329D09                                              Page No. 2 / 30                                             Report Format Version: 6.1.1
Reference No.: 190329D09


                                           Release Control Record


Issue No.              Description                                         Date Issued
RF190329D09            Original release.                                   Apr. 22, 2019




Report No.: RF190329D09                       Page No. 3 / 30       Report Format Version: 6.1.1
Reference No.: 190329D09


1    Certificate of Conformity


            Product: Line Voltage Dual-Tech Dimming Wall Switch Sensor

              Brand: IR-TEC

         Test Model: LDD-700SW

      Series Model: L(X)D-70(Y)SW, where X can be D or B, Y can be 0~2

    Sample Status: ENGINEERING SAMPLE

          Applicant: IR-TEC International Ltd.

          Test Date: Apr. 08 to 12, 2019

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.245)
                           ANSI C63.10: 2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                               , Date:       Apr. 22, 2019
                                Phoenix Huang / Specialist




     Approved by :                                                , Date:       Apr. 22, 2019
                                  May Chen / Manager




Report No.: RF190329D09                         Page No. 4 / 30                      Report Format Version: 6.1.1
Reference No.: 190329D09


2     Summary of Test Results


                              47 CFR FCC Part 15, Subpart C (SECTION 15.245)

        FCC
                                   Test Item                      Result                 Remarks
       Clause
                                                                           Meet the requirement of limit.
       15.207          AC Power Conducted Emission                PASS     Minimum passing margin is -4.28dB
                                                                           at 0.16172MHz.
                                                                           Meet the requirement of limit
       15.245          Radiated Emission Test                     PASS     Minimum passing margin is -2.4dB at
                                                                           21046.17MHz.

      15.215 (c)       20dB Bandwidth                             PASS     Meet the requirement of limit


       15.203          Antenna Requirement                        PASS     No antenna connector is used.

Note:
Determining compliance based on the results of the compliance measurement, not taking into account
measurement instrumentation uncertainty.

2.1    Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16-4-2:

                                                                                         Expanded Uncertainty
                     Measurement                                  Frequency
                                                                                              (k=2) (±)
       Conducted Emissions at mains ports                    150kHz ~ 30MHz                    1.8 dB
                                                              30MHz ~ 1GHz                     4.8 dB
                                                               1GHz ~ 6GHz                     5.0 dB
                   Radiated Emissions                         6GHz ~ 18GHz                     5.0 dB
                                                             18GHz ~ 40GHz                     5.3 dB
                                                             40GHz ~ 53GHz                     5.4 dB



2.2    Modification Record
There were no modifications required for compliance.




Report No.: RF190329D09                         Page No. 5 / 30                            Report Format Version: 6.1.1
Reference No.: 190329D09


3     General Information
3.1    General Description of EUT
 Product                      Line Voltage Dual-Tech Dimming Wall Switch Sensor
 Brand                        IR-TEC
 Test Model                   LDD-700SW
 Series Model                 L(X)D-70(Y)SW, where X can be D or B, Y can be 0~2
 Status of EUT                ENGINEERING SAMPLE
 Power Supply Rating          120~277Vac
 Modulation Type              Pulse
 Operating Frequency          10.5~10.55 GHz
 Number of Channel            1
 Antenna Type                 Refer to Note
 Antenna Connector            Refer to Note
 Accessory Device             NA
 Data Cable Supplied          NA
Note:
1. The EUT has below model names, which are identical to each other in all aspects except for the following
   table:
Model No.                        Description
LDD-700SW                             -
L(X)D-70(Y)SW                        where X can be D or B, Y can be 0~2
Note: From the above models, model: LDD-700SW was selected as representative model for the test and its
      data was recorded in this report.
2. The antenna provided to the EUT, please refer to the following table:
        Antenna Gain (dBi)                    Antenna Type                        Connector Type
                4                            Patch Antenna                             NA
3. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.




Report No.: RF190329D09                       Page No. 6 / 30                       Report Format Version: 6.1.1
Reference No.: 190329D09


3.2    Description of Test Modes

1 channel is provided for test:
          Channel                 Frequency (GHz)
              1                      10.5232




Report No.: RF190329D09                        Page No. 7 / 30   Report Format Version: 6.1.1
Reference No.: 190329D09


3.2.1        Test Mode Applicability and Tested Channel Detail

    EUT                                         APPLICABLE TO
 CONFIGURE                                                                                            DESCRIPTION
   MODE                RE1G             RE<1G               PLC                  BW

         -                √                 √                   √                 √                          -
                   RE1G: Radiated Emission above 1GHz &
Where                                                               RE<1G: Radiated Emission below 1GHz
                   Bandedge Measurement
                PLC: Power Line Conducted Emission                  BW: 20dB Bandwidth Measurement
Note: The EUT had been pre-tested on the positioned of each 3 axis. The worst case was found when positioned on X-plane (below
       1GHz) and Y-plane (above 1GHz).


 Radiated Emission Test (Above 1GHz):

        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
                     Tested Channel                             Modulation Type
                              1                                      Pulse


 Radiated Emission Test (Below 1GHz):

        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
                     Tested Channel                             Modulation Type
                              1                                      Pulse


 Power Line Conducted Emission Test:

        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
                     Tested Channel                             Modulation Type
                              1                                      Pulse


 20dB Bandwidth Measurement:

        Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
        between available modulations, data rates and antenna ports (if EUT with antenna diversity
        architecture).
        Following channel(s) was (were) selected for the final test as listed below.
                     Tested Channel                             Modulation Type
                              1                                      Pulse




Report No.: RF190329D09                                Page No. 8 / 30                               Report Format Version: 6.1.1
Reference No.: 190329D09


 Test Condition:
      APPLICABLE TO        ENVIRONMENTAL CONDITIONS             INPUT POWER        TESTED BY
           RE1G                25deg. C, 65%RH                 120Vac, 60Hz       Nelson Teng
           RE<1G                25deg. C, 65%RH                 120Vac, 60Hz       Nelson Teng
            PLC                 25deg. C, 75%RH                 120Vac, 60Hz         Andy Ho
             BW                 25deg. C, 60%RH                 120Vac, 60Hz      Anderson Chen




Report No.: RF190329D09                       Page No. 9 / 30                  Report Format Version: 6.1.1
Reference No.: 190329D09


3.3    Duty Cycle of Test Signal
Duty cycle of test signal is 100 %, duty factor is not required.




Report No.: RF190329D09                         Page No. 10 / 30   Report Format Version: 6.1.1
Reference No.: 190329D09


3.4     Description of Support Units

The EUT has been tested as an independent unit.
 ID        Descriptions               Qty.                Length (m)        Shielding (Yes/No)   Cores (Qty.)          Remarks
  1.        AC Cable                    1                         2                No                 0            Supplied by client
.Note: The core(s) is(are) originally attached to the cable(s).




3.4.1     Configuration of System under Test




                                                                  EUT




                                                                      (1)




                                                                                                          Under Table




Report No.: RF190329D09                                      Page No. 11 / 30                             Report Format Version: 6.1.1
Reference No.: 190329D09


3.5    General Description of Applied Standards


 The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
 requirements of the following standards:

 FCC Part 15, Subpart C (15.245)
 ANSI C63.10-2013


 All test items have been performed and recorded as per the above standards.




Report No.: RF190329D09                      Page No. 12 / 30                        Report Format Version: 6.1.1
Reference No.: 190329D09


4       Test Types and Results
4.1     Radiated Emission and Bandedge Measurement
4.1.1    Limits of Radiated Emission and Bandedge Measurement

According to 15.245 the field strength of emissions from intentional radiators operated under these
frequencies bands shall not exceed the following:

      Fundamental Frequency                         Field Strength of Fundamental (dBuV/m)
             (MHz)                                    Peak                               Average
                                                      147.9                               127.9
           10500 ~10550                              Field Strength of Harmonics (dBuV/m)
                                                      107.9                                87.9

Harmonic emissions in the restricted bands at and above 17.7 GHz shall not exceed the following field
strength limits:

                            Application                            Field Strength of Harmonics (dBuV/m)
 Field disturbance sensors operating in the 24075-24175 MHz
band and for Other field disturbance sensors designed for use                        87.9
         only within a building or to open building doors.
               All other field disturbance sensors                                   77.5
Note: Field disturbance sensors designed to be used in motor vehicles or aircraft must include features to
prevent continuous operation unless their emissions in the restricted bands, other than the second and third
harmonics from devices operating in the 24075-24175 MHz band, fully comply with the limits given in
Section15.209.

(1) Field strength limits are specified at a distance of 3 meters.
(2) Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated
    by at least 50 dB below the level of the fundamental or to the general radiated emission limits in Section
    15.209, whichever is the lesser attenuation.

Emissions radiated outside of the specified bands, shall be according to the general radiated limits in 15.209
as following:
           Frequencies
                                     Field strength (microvolts/meter) Measurement distance (meters)
               (MHz)
            0.009-0.490                         2400/F(kHz)                               300
            0.490-1.705                          24000/F(kHz)                               30
             1.705-30.0                                30                                   30
                30-88                                  100                                   3
               88-216                                  150                                   3
              216-960                                  200                                   3
             Above 960                                 500                                   3
Note:
1. The lower limit shall apply at the transition frequencies.
2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
3. For frequencies above 1000MHz, the field strength limits are based on average detector, however, the
   peak field strength of any emission shall not exceed the maximum permitted average limits, specified
   above by more than 20dB under any condition of modulation.


Report No.: RF190329D09                        Page No. 13 / 30                        Report Format Version: 6.1.1
Reference No.: 190329D09


4.1.2 Test Instruments
 For other test:
DESCRIPTION &                                                                  CALIBRATED CALIBRATED
                                  MODEL NO.                  SERIAL NO.
MANUFACTURER                                                                   DATE       UNTIL
Test Receiver
                                 ESR7                        102026            Apr. 18, 2018     Apr. 17, 2019
ESR7 R&S
Spectrum Analyzer
                                 N9030B                      MY57141948        June 01, 2018 May 31, 2019
Keysight
Pre-Amplifier
                                  EMC001340                   980142           Jan. 25, 2019     Jan. 24, 2020
EMCI
Loop Antenna(*)
                                  EM-6879                     269              Sep. 07, 2018     Sep. 06, 2019
Electro-Metrics
RF Cable                          NA                          LOOPCAB-001      Jan. 14, 2019     Jan. 13, 2020
RF Cable                          NA                          LOOPCAB-002      Jan. 14, 2019     Jan. 13, 2020
Pre-Amplifier
                                 EMC330N                     980538            May 07, 2018      May 06, 2019
EMCI
Trilog Broadband Antenna
                                  VULB9168                    AMP-ZFL-05       May 07, 2018      May 06, 2019
SCHWARZBECK
RF Cable                          8D                          966-5-1          May 07, 2018      May 06, 2019
RF Cable                          8D                          966-5-2          May 07, 2018      May 06, 2019
RF Cable                          8D                          966-5-3          May 07, 2018      May 06, 2019
Fixed attenuator
                                  UNAT-5+                     PAD-ATT5-02      Jan. 28, 2019     Jan. 27, 2020
Mini-Circuits
Horn_Antenna
                                  BBHA 9120D                  9120D-1819       Nov. 25, 2018     Nov. 24, 2019
SCHWARZBECK
Pre-Amplifier
                                  EMC12630SE                  980509           May 07, 2018      May 06, 2019
EMCI
RF Cable
                                  EMC104-SM-SM-1500           180503           May 07, 2018      May 06, 2019
EMCI
RF Cable
                                  EMC104-SM-SM-2000           180501           May 07, 2018      May 06, 2019
EMCI
RF Cable
                                  EMC104-SM-SM-6000           180505           May 07, 2018      May 06, 2019
EMCI
Pre-Amplifier
                                  EMC184045SE                 980387           Jan. 28, 2019     Jan. 27, 2020
EMCI
Horn_Antenna
                                  BBHA 9170                   BBHA9170519      Nov. 25, 2018     Nov. 24, 2019
SCHWARZBECK
RF Cable                          EMC102-KM-KM-1200 160924                     Jan. 28, 2019     Jan. 27, 2020
RF Cable                          EMC102-KM-KM-1200 160925                     Jan. 28, 2019     Jan. 27, 2020
Software                          ADT_Radiated_V8.7.08 NA                      NA                NA
Boresight Antenna Tower &
Turn Table                        MF-7802BS                   MF780208530      NA                NA
Max-Full
Spectrum Analyzer
                                 FSV40                       100964            June 20, 2018 June 19, 2019
R&S
Fixed Attenuator
                                 MDCS18N-10                  MDCS18N-10-01 Apr. 16, 2018        Apr. 15, 2019
Mini-Circuits

Note: Rad. Emission (below 40GHz) 190408 / Power 190412
1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to
   NML/ROC and NIST/USA.
2. The test was performed in 966 Chamber No. 5.
3. Loop antenna was used for all emissions below 30 MHz.
4. Tested Date: Apr. 08 to 12, 2019




Report No.: RF190329D09                        Page No. 14 / 30                        Report Format Version: 6.1.1
Reference No.: 190329D09


For Above 40GHz:
DESCRIPTION &                                                             CALIBRATED          CALIBRATED
                              MODEL NO.                 SERIAL NO.
MANUFACTURER                                                              DATE                UNTIL
Spectrum Analyzer
                              E4446A                    MY48250254        Nov. 14, 2018       Nov. 13, 2019
Agilent
*Harmonic Mixer
(33~55GHz)                    M22HWD                    110215-1          Oct. 17, 2017       Oct. 16, 2019
OML
*Horn Antenna
(33~55GHz)                    M22RH                     110215-1          Oct. 17, 2017       Oct. 16, 2019
OML
*Diplexer
                              DPL26                     DPL26_01          Oct. 17, 2017       Oct. 16, 2019
EMCI
*Diplexer
                              DPL26                     DPL26_02          Oct. 17, 2017       Oct. 16, 2019
EMCI
*Precision 30dB
Attenuator                    11708A                    MY55260015        Oct. 17, 2017       Oct. 16, 2019
Keysight
*Zero-Bias Detector
(50~75GHz)                    WR15ZBD                   WR15R5 1-30       Oct. 17, 2017       Oct. 16, 2019
Vdi
Digital Storage
                              DSOX6002A+DSOX60
Oscilloscope                                            MY56270092        Jan. 17, 2019       Jan. 16, 2020
                              00-AMG
Keysight
*WR15CH Conical Horn
                              WR15CH                    WR15CH-01         Oct. 17, 2017       Oct. 16, 2019
Keysight
*WR10CH Conical Horn
                              WR10CH                    WR10CH-01         Oct. 17, 2017       Oct. 16, 2019
Keysight
*Millimeter-Wave Signal
Generator Frequency
Extension Module (50~75 E8257DV15                       US54250106        Oct. 17, 2017       Oct. 16, 2019
GHz)
Keysight
PSG analog signal
generator                     E8257D                    MY53401987        June 26, 2018       June 25, 2019
Keysight
Antenna Tower & Turn
Table                         NA                        NA                NA                  NA
CT
Note: Rad. Emission (above 40GHz) 190408
1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to
   NML/ROC and NIST/USA.
2. *The calibration interval of the above test instruments is 24 months and the calibrations are traceable to
   NML/ROC and NIST/USA.
3. The test was performed in 966 Chamber No. 5
4. Test Date: Apr. 08, 2019




Report No.: RF190329D09                        Page No. 15 / 30                        Report Format Version: 6.1.1
Reference No.: 190329D09


4.1.3 Test Procedures
For Radiated emission: Below 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
     room. The table was rotated 360 degrees to determine the position of the highest radiation.

b.      The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
        of a variable-height antenna tower.

c.      Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
        measurement.

d.      For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
        from 0 degrees to 360 degrees to find the maximum reading.

e.      The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with
        Maximum Hold Mode.
Note:
1.      The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9kHz at frequency
        below 30MHz.

For Radiated emission: Above 30MHz
a. The EUT was placed on the top of a rotating table 0.8 meters (for 30MHz ~ 1GHz) / 1.5 meters (for above
    1GHz) above the ground at 3 meter chamber room for test. The table was rotated 360 degrees to
    determine the position of the highest radiation.
b.      The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
        of a variable-height antenna tower.
c.      The height of antenna is varied from one meter to four meters above the ground to determine the
        maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
        make the measurement.
d.      For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned
        to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to
        find the maximum reading.
e.      The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
        hold mode when the test frequency is below 1 GHz.
f.      The test-receiver system was set to peak and average detect function and specified bandwidth with
        maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
        average limit, measurement with the average detector is unnecessary.

Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
    Quasi-peak detection (QP) at frequency below 1GHz.
2. The resolution bandwidth is 1MHz and video bandwidth of test receiver/spectrum analyzer is 3MHz for
    Peak detection (PK) at frequency above 1GHz.
3. The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video bandwidth is ≥ 1/T
    (Duty cycle < 98%) or 10Hz (Duty cycle ≥ 98%) for Average detection (AV) at frequency above 1GHz.
4. All modes of operation were investigated and the worst-case emissions are reported.


4.1.4      Deviation from Test Standard

     No deviation.



Report No.: RF190329D09                           Page No. 16 / 30                        Report Format Version: 6.1.1
Reference No.: 190329D09


4.1.5   Test Setup

 For Radiated emission below 30MHz


                                                                    1m
            EUT&                       3m
            Support Units

                              Turn Table

               80cm


                                     Ground Plane
                                     Test Receiver




 For Radiated emission 30MHz to 1GHz

                                                       Ant. Tower
                                                                     1-4m
                                                                     Variable
              EUT&
                                           3m
                                            10m
              Support Units

                                  Turn Table

                  80cm


                                       Ground Plane

                                       Test Receiver




Report No.: RF190329D09                 Page No. 17 / 30                 Report Format Version: 6.1.1
Reference No.: 190329D09


 For Radiated emission 1GHz ~ 40GHz



                                                                   Ant. Tower             1-4m
                                                                                          Variable
               EUT&                  Measurement distance
               Support Units

                                       Turn Table
                                                       Absorber

                 150cm


                                              Ground Plane
                                              Test Receiver




 For Radiated emission above 40GHz

                                                                   Ant. Tower             1-4m
                                                                                          Variable
               EUT&                   Measurement Distance
               Support Units

                                      Turn Table Absorber

                  150cm

                                                                         Harmonic Mixer
                                              Ground Plane
                           Test Receiver
                                                                                IF

                                                                                     LO




 For the actual test configuration, please refer to the attached file (Test Setup Photo).



4.1.6   EUT Operating Conditions

Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF190329D09                         Page No. 18 / 30                            Report Format Version: 6.1.1
Reference No.: 190329D09


4.1.7    Test Results
Above 1GHz Data:
CHANNEL                     TX Channel 1            DETECTOR                 Peak (PK)
FREQUENCY RANGE             1GHz ~ 18GHz            FUNCTION                 Average (AV)


                    ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION                           ANTENNA     TABLE        RAW         CORRECTION
         FREQ.                    LIMIT    MARGIN
NO.                  LEVEL                              HEIGHT     ANGLE       VALUE          FACTOR
         (MHz)                  (dBuV/m)    (dB)
                    (dBuV/m)                              (m)     (Degree)     (dBuV)          (dB/m)
  1      8140.85      55.4 PK     74.0      -18.6        1.50 H     42          47.4              8.0
  2      8140.85      46.3 AV    54.0        -7.7        1.50 H     42          38.3             8.0
  3     *10523.20    101.5 PK    147.9      -46.4        3.50 H     58          90.2             11.3
  4     *10523.20    101.2 AV    127.9      -26.7        3.50 H     58          89.9             11.3
  5     12835.40      59.0 PK    74.0       -15.0        2.50 H     51          47.9             11.1
  6     12835.40      48.5 AV    54.0        -5.5        2.50 H     51          37.4             11.1
                     ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION                           ANTENNA     TABLE        RAW         CORRECTION
         FREQ.                    LIMIT    MARGIN
NO.                  LEVEL                              HEIGHT     ANGLE       VALUE          FACTOR
         (MHz)                  (dBuV/m)    (dB)
                    (dBuV/m)                              (m)     (Degree)     (dBuV)          (dB/m)
  1      8185.90      54.8 PK     74.0      -19.2        1.00 V     77          47.0              7.8
  2      8185.90      42.1 AV     54.0      -11.9        1.00 V      77         34.3              7.8
  3     *10523.20    107.3 PK    147.9      -40.6        2.50 V     360         96.0             11.3
  4     *10523.20    104.9 AV    127.9      -23.0        2.50 V     360         93.6             11.3
  5     12299.05      57.0 PK    74.0       -17.0        3.50 V     243         46.4             10.6
  6     12299.05      43.9 AV    54.0       -10.1        3.50 V     243         33.3             10.6
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit.
   5. " * ": Fundamental frequency.




Report No.: RF190329D09                      Page No. 19 / 30                          Report Format Version: 6.1.1
Reference No.: 190329D09


CHANNEL                    TX Channel 1             DETECTOR                 Peak (PK)
FREQUENCY RANGE            18GHz ~ 53GHz            FUNCTION                 Average (AV)


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION                           ANTENNA     TABLE        RAW         CORRECTION
        FREQ.                    LIMIT     MARGIN
NO.                  LEVEL                              HEIGHT     ANGLE       VALUE          FACTOR
        (MHz)                  (dBuV/m)     (dB)
                    (dBuV/m)                              (m)     (Degree)     (dBuV)          (dB/m)
  1    21046.17      85.5 PK    107.9       -22.4        1.00 H      57         94.7             -9.2
  2    21046.17      80.4 AV    87.9         -7.5        1.00 H      57         89.6             -9.2
  3    31569.33      69.9 PK    107.9       -38.0        1.00 H      1          76.9             -7.0
  4    31569.33      58.2 AV    87.9        -29.7        1.00 H      1          65.2             -7.0
  5    42170.65      45.8 PK    107.9       -62.1        1.00 H     185         45.8              0.0
  6    42170.65      36.6 AV    87.9        -51.3        1.00 H     185         36.6             0.0
  7    52610.23      50.3 PK    107.9       -57.6        1.00 H     175         50.3              0.0
  8    52610.23      40.1 AV    87.9        -47.8        1.00 H     175         40.1             0.0
                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION                           ANTENNA     TABLE        RAW         CORRECTION
        FREQ.                    LIMIT     MARGIN
NO.                  LEVEL                              HEIGHT     ANGLE       VALUE          FACTOR
        (MHz)                  (dBuV/m)     (dB)
                    (dBuV/m)                              (m)     (Degree)     (dBuV)          (dB/m)
  1    21046.17      87.1 PK    107.9       -20.8        2.00 V     42          96.3             -9.2
  2    21046.17      85.5 AV    87.9         -2.4        2.00 V      42         94.7             -9.2
  3    31569.33      78.1 PK    107.9       -29.8        2.00 V     343         85.1             -7.0
  4    31569.33      77.7 AV    87.9        -10.2        2.00 V     343         84.7             -7.0
  5    42092.47      52.0 PK    107.9       -55.9        2.00 V     80          52.0              0.0
  6    42092.47      50.5 AV    87.9        -37.4        2.00 V     80          50.5              0.0
  7    52610.54      55.7 PK    107.9       -52.2        2.00 V     60          55.7              0.0
  8    52610.54      53.5 AV    87.9        -34.4        2.00 V     60          53.5              0.0
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit.




Report No.: RF190329D09                      Page No. 20 / 30                          Report Format Version: 6.1.1
Reference No.: 190329D09


Below 1GHz Data:
CHANNEL                    TX Channel 1            DETECTOR
                                                                            Quasi-Peak (QP)
FREQUENCY RANGE            9kHz ~ 1GHz             FUNCTION


                  ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                    EMISSION                          ANTENNA     TABLE        RAW         CORRECTION
        FREQ.                    LIMIT    MARGIN
NO.                  LEVEL                             HEIGHT     ANGLE       VALUE          FACTOR
        (MHz)                  (dBuV/m)    (dB)
                    (dBuV/m)                             (m)     (Degree)     (dBuV)          (dB/m)
  1      40.28       33.7 QP     40.0       -6.3        3.00 H     360         47.3            -13.6
  2     221.63       31.0 QP     46.0      -15.0        1.50 H     306         46.5            -15.5
  3     241.76       35.6 QP     46.0      -10.4        1.00 H     303         49.8            -14.2
  4     261.89       36.3 QP     46.0       -9.7        1.00 H     307         50.0            -13.7
  5     282.12       34.0 QP     46.0      -12.0        1.00 H     254         46.9            -12.9
  6     543.98       29.2 QP     46.0      -16.8        1.50 H     89          36.2             -7.0
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit of frequency range 30MHz~1000MHz.
   5. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF190329D09                     Page No. 21 / 30                          Report Format Version: 6.1.1
Reference No.: 190329D09


CHANNEL                    TX Channel 1            DETECTOR
                                                                            Quasi-Peak (QP)
FREQUENCY RANGE            9kHz ~ 1GHz             FUNCTION


                    ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                    EMISSION                          ANTENNA     TABLE        RAW         CORRECTION
        FREQ.                    LIMIT    MARGIN
NO.                  LEVEL                             HEIGHT     ANGLE       VALUE          FACTOR
        (MHz)                  (dBuV/m)    (dB)
                    (dBuV/m)                             (m)     (Degree)     (dBuV)          (dB/m)
  1      40.28       37.1 QP     40.0       -2.9        1.50 V     360         50.7            -13.6
  2      80.59       25.3 QP     40.0      -14.7        1.00 V     154         43.3            -18.0
  3     221.63       29.8 QP     46.0      -16.2        1.00 V     283         45.3            -15.5
  4     241.76       32.1 QP     46.0      -13.9        1.00 V     112         46.3            -14.2
  5     261.94       32.1 QP     46.0      -13.9        1.00 V     289         45.8            -13.7
  6     282.07       28.9 QP     46.0      -17.1        1.50 V     107         41.8            -12.9
REMARKS:
   1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
   2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
   3. Margin value = Emission Level – Limit value
   4. The other emission levels were very low against the limit of frequency range 30MHz~1000MHz.
   5. The emission levels were very low against the limit of frequency range 9kHz~30MHz: the amplitude of
      spurious emissions attenuated more than 20 dB below the permissible value to be report.




Report No.: RF190329D09                     Page No. 22 / 30                          Report Format Version: 6.1.1
Reference No.: 190329D09


4.2     Conducted Emission Measurement
4.2.1     Limits of Conducted Emission Measurement

                                                            Conducted Limit (dBuV)
        Frequency (MHz)
                                                Quasi-peak                              Average
          0.15 - 0.5                              66 - 56                                56 - 46
          0.50 - 5.0                                 56                                     46
          5.0 - 30.0                                 60                                     50
Note: 1. The lower limit shall apply at the transition frequencies.
      2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz.


4.2.2     Test Instruments

       DESCRIPTION &                                                 CALIBRATED          CALIBRATED
                              MODEL NO.           SERIAL NO.
       MANUFACTURER                                                  DATE                UNTIL
      Test Receiver
                              ESCS 30            847124/029          Oct. 24, 2018      Oct. 23, 2019
      R&S
      Line-Impedance
      Stabilization Network
                              ESH3-Z5            848773/004          Oct. 22, 2018      Oct. 21, 2019
      (for EUT)
      R&S
      Line-Impedance
      Stabilization Network
                              ESH3-Z5            835239/001          Mar. 17, 2019      Mar. 16, 2020
      (for Peripheral)
      R&S
      50 ohms Terminator      N/A                3                   Oct. 22, 2018      Oct. 21, 2019
      RF Cable                5D-FB              COCCAB-001          Sep. 28, 2018      Sep. 27, 2019
      Fixed attenuator
                              STI02-2200-10      003                 Mar. 14, 2019      Mar. 13, 2020
      EMCI
      Software                BVADT_Cond_
                                                 NA                  NA                 NA
      BVADT                   V7.3.7.4

Note:
   1. The calibration interval of the above test instruments are 12 months and the calibrations are
      traceable to NML/ROC and NIST/USA.
   2. The test was performed in Conduction 1.
   3 Tested Date: Apr. 12, 2019




Report No.: RF190329D09                        Page No. 23 / 30                        Report Format Version: 6.1.1
Reference No.: 190329D09


4.2.3    Test Procedures
 a.     The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
        connected to the power mains through a line impedance stabilization network (LISN). Other support
        units were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50uH
        of coupling impedance for the measuring instrument.
 b.     Both lines of the power mains connected to the EUT were checked for maximum conducted
        interference.
 c.     The frequency range from 150kHz to 30MHz was searched. Emission levels under (Limit - 20dB) was
        not recorded.

 Note: The resolution bandwidth and video bandwidth of test receiver is 9kHz for quasi-peak detection (QP)
       and average detection (AV) at frequency 0.15MHz-30MHz.

4.2.4    Deviation from Test Standard

 No deviation.

4.2.5    Test Setup

                                 Vertical Ground
                                 Reference Plane                                Test Receiver


                                 EUT
                      40cm




                                                        80cm
                      LISN



                                                                   Horizontal Ground
                                                                   Reference Plane

                       Note: 1.Support units were connected to second LISN.




 For the actual test configuration, please refer to the attached file (Test Setup Photo).

4.2.6    EUT Operating Conditions

Same as 4.1.6.




Report No.: RF190329D09                         Page No. 24 / 30                            Report Format Version: 6.1.1
Reference No.: 190329D09


4.2.7   Test Results

                                                                                 Quasi-Peak (QP) /
Phase                       Line (L)                       Detector Function
                                                                                 Average (AV)

                                        Phase Of Power : Line (L)
        Frequency Correction      Reading Value Emission Level                Limit               Margin
 No                Factor             (dBuV)           (dBuV)                (dBuV)                 (dB)
          (MHz)     (dB)           Q.P.    AV.      Q.P.     AV.          Q.P.      AV.        Q.P.      AV.
  1      0.16172    10.02         51.08   36.50    61.10    46.52        65.38    55.38       -4.28     -8.86
  2      0.24447    10.05         44.34   31.59    54.39    41.64        61.94    51.94       -7.55    -10.30
  3      0.31016    10.06         37.85   22.80    47.91    32.86        59.97    49.97      -12.06 -17.11
  4      0.39219    10.07         32.92   21.06    42.99    31.13        58.02    48.02      -15.03 -16.89
  5      0.66953    10.09         25.14   16.12    35.23    26.21        56.00    46.00      -20.77 -19.79
  6      5.76953    10.33         22.08    8.00    32.41    18.33        60.00    50.00      -27.59 -31.67
Remarks:
       1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
       2. The emission levels of other frequencies were very low against the limit.
       3. Margin value = Emission level – Limit value
       4. Correction factor = Insertion loss + Cable loss
       5. Emission Level = Correction Factor + Reading Value




Report No.: RF190329D09                       Page No. 25 / 30                        Report Format Version: 6.1.1
Reference No.: 190329D09


                                                                                 Quasi-Peak (QP) /
Phase                       Neutral (N)                    Detector Function
                                                                                 Average (AV)

                                       Phase Of Power : Neutral (N)
        Frequency Correction      Reading Value Emission Level                Limit               Margin
 No                Factor             (dBuV)           (dBuV)                (dBuV)                 (dB)
          (MHz)     (dB)           Q.P.     AV.     Q.P.     AV.          Q.P.      AV.        Q.P.      AV.
  1      0.15000     9.93         46.65    30.73   56.58    40.66        66.00    56.00       -9.42    -15.34
  2      0.16953     9.93         49.11    34.64   59.04    44.57        64.98    54.98       -5.94    -10.41
  3      0.24375     9.94         42.75    28.99   52.69    38.93        61.97    51.97       -9.28    -13.04
  4      0.31016     9.95         35.60    20.29   45.55    30.24        59.97    49.97      -14.42 -19.73
  5      0.38828     9.96         31.21    16.60   41.17    26.56        58.10    48.10      -16.93 -21.54
  6      5.33203    10.18         23.03    14.62   33.21    24.80        60.00    50.00      -26.79 -25.20
Remarks:
       1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
       2. The emission levels of other frequencies were very low against the limit.
       3. Margin value = Emission level – Limit value
       4. Correction factor = Insertion loss + Cable loss
       5. Emission Level = Correction Factor + Reading Value




Report No.: RF190329D09                       Page No. 26 / 30                        Report Format Version: 6.1.1
Reference No.: 190329D09


4.3     20dB Bandwidth Measurement
4.3.1    Limits of 20dB bandwidth Measurement
According to 15.215(c), the requirement is to ensure the 20dB bandwidth of the emission, or whatever
bandwidth may otherwise be specified, is contained within the frequency band designated in the rule section
under which the equipment is operated.


4.3.2    Test Instruments

 Refer to section 4.1.2 to get information of above instrument.

4.3.3    Test Procedures

The bandwidth of the fundamental frequency was measured by spectrum analyzer with 300 Hz RBW and
1 kHz VBW. The 20dB bandwidth is defined as the total spectrum the power of which is higher than peak
power minus 20dB.
Set both RBW and VBW of spectrum analyzer to 100 kHz and 300 kHz with suitable frequency span from
band edge. The bandedge was measured and recorded.


4.3.4    Deviation from Test Standard

No deviation


4.3.5    Test Setup


                                                           Spectrum
           EUT
                                    Attenuator             Analyzer




4.3.6    EUT Operating Conditions

 Same as Item 4.1.6.




Report No.: RF190329D09                          Page No. 27 / 30                   Report Format Version: 6.1.1
Reference No.: 190329D09


4.3.7   Test Results

For 20dB Bandwidth




For Bandedge




Report No.: RF190329D09    Page No. 28 / 30   Report Format Version: 6.1.1
Reference No.: 190329D09


5    Pictures of Test Arrangements


 Please refer to the attached file (Test Setup Photo).




Report No.: RF190329D09                        Page No. 29 / 30   Report Format Version: 6.1.1
Reference No.: 190329D09


Appendix – Information of the Testing Laboratories

We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Lin Kou EMC/RF Lab                                    Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                   Tel: 886-3-6668565
Fax: 886-2-26051924                                   Fax: 886-3-6668323

Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892

Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF190329D09                       Page No. 30 / 30                  Report Format Version: 6.1.1
Reference No.: 190329D09



Document Created: 2019-05-10 16:45:43
Document Modified: 2019-05-10 16:45:43

© 2019 FCC.report
This site is not affiliated with or endorsed by the FCC