Test report

FCC ID: NPKAVC922

Test Report

Download: PDF
FCCID_861777

                                                                                           Test report No.        : 27KE0187—HO—A—R1
                         L                                                                 Page                   : 1 of 56
               Underwriters                                                                Issued date            : October 12, 2007
               Laboratories UL Japan, Inc.                                                 Revised date           : October 26, 2007
                                                                                           FCC ID                 : NPKAVC922


                                    RADIO TEST REPORT
                                   Test Report No. : 27KE0187—HO—A—R1
         Applicant                                $          SANYO Electric Co., Ltd.
         Type of Equipment                        s          WLAN Module
         Model No.                                &          QXxXAVCO22———P
         FCC ID                                   $          NPKAVCO22
         Test standard                            $          FCC Part 15 Subpart C 2007
                                                             Section 15.207, Section 15.247
          Test Result                             :          Complied
          1.    This test report shall not be reproduced in full or partial, without the written approval of
                UL Japan, Inc.
          2.    The results in this report apply only to the sample tested.
          3.    This sample tested is in compliance with the above regulation.
          4.     The test results in this report are traceable to the national or international standards.
          5.    Original test report number of this report is 27KE0187—HO—A.

                             Date of test:
                                                      September 8 to October 5, 2007
                             Tested by:                                                                         5*
                                                                  maeees.                            / 7 3xA
                                                            Takashi Nakazawa                                   Hisayoshi Sato
                                                              EMC Services                                     EMC Services

                                                                                                      /M/fifi 7.Jf;‘
                                                             Shinya Watanabe                         *         Yutaka Yoshida
                                                              EMC Services                                     EMC Services



                                                            ‘Ta-kah,iro Hatakeda
                                                               EMC Services
                             Approved by :


                                                               Tetsuo Maeno
                                                       Site Manager of EMC Services

                                                                 This laboratory is accredited by the NVLAP LAB CODE
                                                      °           200572—0, U.S.A. The tests reported herein have been

          mV                         &                            performed in accordance with its terms of accreditation.
                                                                  *As for the range of Accreditation in NVLAP, you may
                                                                  refer to the WEB address, http://uljapan.co.jp/eme/nvlap.htm
          NVLAP LAB CODE: 200572—0


UL Japan, Inc.
Head Office EMC Lab.
4383—326 Asama—cho, Ise—shi, Mie—ken 516—0021 JAPAN
Telephone        : +81 596 24 8116
Facsimile        : +81 596 24 8124                                                                                     MFO6Ob (18.06.07)


                                                                                             Test report No.      : 27KE0187-HO-A-R1
                                                                                             Page                 : 2 of 56
                                                                                             Issued date          : October 12, 2007
                                                                                             Revised date         : October 26, 2007
                                                                                             FCC ID               : NPKAVC922




CONTENTS                                                                                                                    PAGE

SECTION 1: Client information...............................................................................................3
SECTION 2: Equipment under test (E.U.T.) ..........................................................................3
SECTION 3: Test specification, procedures & results ...........................................................4
SECTION 4: Operation of E.U.T. during testing....................................................................8
SECTION 5: Conducted Emission .........................................................................................10
SECTION 6: Spurious Emission.............................................................................................11
SECTION 7: 6dB Bandwidth..................................................................................................12
SECTION 8: Maximum Peak Output Power ........................................................................12
SECTION 9: Peak Power Density ..........................................................................................12
APPENDIX 1: Photographs of test setup...............................................................................13
    Conducted Emission ........................................................................................................13
    Spurious Emission (Radiated) ........................................................................................14
    Worst Case Position (Horizontal: Z-axis/ Vertical:Y-axis) .........................................15
APPENDIX 2: Data of EMI test ..............................................................................................16
    Conducted Emission ........................................................................................................16
    6dB Bandwidth ................................................................................................................23
    Maximum Peak Output Power.......................................................................................26
    Radiated Spurious Emission (below 1GHz) ..................................................................28
    Radiated Spurious Emission (above 1GHz) ..................................................................35
    Conducted Spurious Emission........................................................................................42
    Conducted emission Band Edge compliance.................................................................49
    Power Density ..................................................................................................................50
    99%Occupied Bandwidth ...............................................................................................53
APPENDIX 3:Test instruments ...............................................................................................55




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                             Test report No.   : 27KE0187-HO-A-R1
                                                                             Page              : 3 of 56
                                                                             Issued date       : October 12, 2007
                                                                             Revised date      : October 26, 2007
                                                                             FCC ID            : NPKAVC922




SECTION 1: Client information
Company Name                         :    SANYO Electric Co., Ltd.
Address                              :    1-1 Sanyo-cho, Daito City, Osaka 574-8534, Japan
Telephone Number                     :    +81-72-870-6132
Facsimile Number                     :    +81-72-875-9358
Contact Person                       :    Keiji Hirao



SECTION 2: Equipment under test (E.U.T.)
2.1     Identification of E.U.T.

Type of Equipment                    :    WLAN Module
Model No.                            :    QXXAVC922---P
Serial No.                           :    1
Rating                               :    DC3.3V
Country of Manufacture               :    Japan
Receipt Date of Sample               :    August 22, 2007
Condition of EUT                     :    Production model
                                          (Not for Sale: This sample is equivalent to mass-produced items.)
Modification of EUT                  :    No modification by the test lab.


2.2     Product Description

Model No: QXXAVC922---P (referred to as the EUT in this report) is the WLAN Module.

Clock frequency(ies) in the system   :    40MHz
Equipment Type                       :    Transceiver
Frequency of Operation               :    2412-2462MHz
Bandwidth & Channel Spacing          :    20MHz & 5MHz
Modulation                           :    11b: DSSS (DBPSK, DQPSK, CCK)
                                          11g: OFDM (BPSK, QPSK, 16QAM, 64QAM)
Power Supply                         :    DC3.3V
Antenna Type                         :    Chip Dielectric Antenna
Antenna Connector Type               :    Chip Coaxial Connector (HSC)
Antenna Gain                         :    2.14 dBi (max)




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                  Test report No.   : 27KE0187-HO-A-R1
                                                                                  Page              : 4 of 56
                                                                                  Issued date       : October 12, 2007
                                                                                  Revised date      : October 26, 2007
                                                                                  FCC ID            : NPKAVC922




SECTION 3: Test specification, procedures & results

3.1     Test Specification

Test Specification                  :        FCC Part15 Subpart C: 2007

Title                               :        FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional
                                             Radiators
                                             Section 15.207 Conducted limits
                                             Section 15.247 Operation within the bands 902-928MHz,
                                                            2400-2483.5MHz, and 5725-5850MHz

FCC 15.31 (e)
As this EUT does not have a regulator, the supplied voltage depends on the installed device. Therefore the certification
is limited only for the device which can provide voltage(DC3.3V) constantly.

FCC Part 15.203 Antenna requirement
It is impossible for end users to replace the antenna, because the antenna is mounted inside of the host device in which
the EUT is installed. Therefore, the equipment complies with the antenna requirement of Section 15.203.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                        Test report No.    : 27KE0187-HO-A-R1
                                                                                        Page               : 5 of 56
                                                                                        Issued date        : October 12, 2007
                                                                                        Revised date       : October 26, 2007
                                                                                        FCC ID             : NPKAVC922


 3.2      Procedures and results

No.       Item               Test Procedure        Specification              Remarks    Deviation Worst margin    Results
1 Conducted              FCC: ANSI C63.4:2003 FCC: Section 15.207         -              N/A                    Complied
    emission             7. AC powerline                                                           14.0dB
                         conducted emission                                                        9.10800MHz,
                         measurements                                                              AV, N
                         IC: RSS-Gen 7.2.2    IC: RSS-Gen 7.2.2                                    9.94450MHz,
                                                                                                   AV, N

2      6dB Bandwidth     FCC: ANSI C63.4:2003 FCC: Section                Conducted      N/A                       Complied
                         13. Measurement of    15.247(a)(2)
                         intentional radiators
                         IC: RSS-Gen 4.6.2     IC: RSS-210 A8.2(a)


3      Maximum Peak      FCC: ANSI C63.4:2003 FCC: Section                Conducted      N/A                       Complied
       Output Power      13. Measurement of    15.247(b)(3)
                         intentional radiators
                         IC: RSS-Gen 4.8       IC: RSS-210 A8.4(4)

                                                                                                      See data.
4      Restricted Band   FCC: ANSI C63.4:2003 FCC: Section 15.247 (d) Conducted          N/A                       Complied
       Edges             13. Measurement of                           Radiated
                         intentional radiators
                         IC: -                 IC: RSS-210 A8.5


5      Power Density     FCC: ANSI C63.4:2003 FCC: Section 15.247 (e) Conducted          N/A                       Complied
                         13. Measurement of
                         intentional radiators
                         IC: -                 IC: RSS-210 A8.2(b)


6      Spurious          FCC: ANSI C63.4:2003                             Conducted      N/A          [Tx]         Complied
                                               FCC: Section15.247(d)
       Emission          13. Measurement of                               Radiated                    6.7dB
                         intentional radiators                                                        119.996MHz
                                                                                                      Vert., QP
                                                IC: RSS-210 A8.5                                      [Rx]
                         IC: RSS-Gen 4.9
                                                    RSS-Gen 7.2.1 and                                 8.7dB
                             RSS-Gen 4.10
                                                7.2.3                                                 119.996MHz
                                                                                                      Vert., QP
Note: UL Japan, Inc.’s EMI Work Procedures No.QPM05 and QPM15.
 *These tests were also referred to "Guidance on Measurement of Digital Transmission Systems Operating under Section15.247".
 *These tests were performed without any deviations from test procedure except for additions or exclusions.


 3.3      Addition to standards

No. Item                 Test Procedure         Specification             Remarks        Deviation Worst margin Results
1 99% Occupied           IC: RSS-Gen 4.6.1      IC: RSS-Gen 4.6.1         Conducted      N/A       N/A          N/A
    Band Width




 UL Japan, Inc.
 Head Office EMC Lab.
 4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
 Telephone       : +81 596 24 8116
 Facsimile       : +81 596 24 8124


                                                                                    Test report No.   : 27KE0187-HO-A-R1
                                                                                    Page              : 6 of 56
                                                                                    Issued date       : October 12, 2007
                                                                                    Revised date      : October 26, 2007
                                                                                    FCC ID            : NPKAVC922



3.4      Uncertainty

The following uncertainties have been calculated to provide a confidence level of 95% using a coverage factor k=2.

Conducted Emission
The measurement uncertainty for this test is ±2.66dB.
The data listed in this test report has enough margin, more than the site margin.

Spurious Emission (Radiated)
The measurement uncertainty for this test using Biconical antenna is ±4.59dB(3m).
The measurement uncertainty for this test using Logperiodic antenna is ±4.62dB(3m).
The measurement uncertainty for this test using Horn antenna is ±5.27dB.
The data listed in this test report has enough margin, more than the site margin.

Other test except Conducted Emission and Spurious Emission (Radiated)
The measurement uncertainty for this test is ±3.0dB.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                               Test report No.   : 27KE0187-HO-A-R1
                                                                               Page              : 7 of 56
                                                                               Issued date       : October 12, 2007
                                                                               Revised date      : October 26, 2007
                                                                               FCC ID            : NPKAVC922



3.5     Test Location

UL Japan, Inc. Head Office EMC Lab. *NVLAP Lab. code: 200572-0
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone: +81 596 24 8116                Facsimile: +81 596 24 8124
                     FCC          IC Registration Width x Depth x         Size of                      Other
                     Registration Number                Height (m)        reference ground plane (m) / rooms
                     Number                                               horizontal conducting plane
 No.1 semi-anechoic 313583        IC4247            19.2 x 11.2 x 7.7m    7.0 x 6.0m                   No.1 Power
 chamber                                                                                               source room
 No.2 semi-anechoic 655103        IC4247-2          7.5 x 5.8 x 5.2m      4.0 x 4.0m                   -
 chamber
 No.3 semi-anechoic 148738        IC4247-3          12.0 x 8.5 x 5.9m     6.8 x 5.75m                   No.3
 chamber                                                                                                Preparation
                                                                                                        room
 No.3 shielded room -              -                  4.0 x 6.0 x 2.7m    N/A                           -
 No.4 semi-anechoic 134570         IC4247-4           12.0 x 8.5 x 5.9m   6.8 x 5.75m                   No.4
 chamber                                                                                                Preparation
                                                                                                        room
 No.4 shielded room -                -                4.0 x 6.0 x 2.7m       N/A                        -
 No.5 semi-anechoic -                -                                                                  -
                                                      6.0 x 6.0 x 3.9m       6.0 x 6.0m
 chamber
 No.6 shielded         -             -                4.0 x 4.5 x 2.7m       4.75 x 5.4 m                 -
 room
 No.6 measurement -                  -                4.75 x 5.4 x 3.0m 4.75 x 4.15 m                     -
 room
 No.7 shielded room -                -                4.7 x 7.5 x 2.7m       4.7 x 7.5m                   -
 No.8 measurement -                  -                3.1 x 5.0 x 2.7m       N/A                          -
 room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 x 2.0m for No.1, No.2, No.3, and No.4 semi-anechoic
chambers and No.3 and No.4 shielded rooms.

3.6   Test set up, Test instruments and Data of EMI

Refer to APPENDIX 1 to 3.




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                              Test report No.   : 27KE0187-HO-A-R1
                                                                              Page              : 8 of 56
                                                                              Issued date       : October 12, 2007
                                                                              Revised date      : October 26, 2007
                                                                              FCC ID            : NPKAVC922




SECTION 4: Operation of E.U.T. during testing

4.1     Operating Modes

Test                              Mode                                                 Tested frequency
Conducted emission                IEEE802.11b Transmitting (Tx), 11Mbps                2412MHz
Spurious Emission                 IEEE802.11g Transmitting (Tx), 54Mbps                2437MHz
                                                                                       2462MHz
                                  IEEE802.11b/g Receiving (Rx)                         2437MHz
6dB Bandwidth                     IEEE802.11b Transmitting (Tx), 11Mbps                2412MHz
Maximum Peak Output Power         IEEE802.11g Transmitting (Tx), 54Mbps                2437MHz
Power Density                                                                          2462MHz
99% Occupied Bandwidth
Restricted Band Edge             IEEE802.11b Transmitting (Tx), 11Mbps                 2412MHz
                                 IEEE802.11g Transmitting (Tx), 54Mbps                 2462MHz
Transmitting duty was 100% on all tests.

As a result of preliminary test, the formal test was performed with the above modes, which had the maximum rated
power. (Refer to Maximum Peak Output Power)




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                       Test report No.     : 27KE0187-HO-A-R1
                                                                                       Page                : 9 of 56
                                                                                       Issued date         : October 12, 2007
                                                                                       Revised date        : October 26, 2007
                                                                                       FCC ID              : NPKAVC922



4.2 Configuration and peripherals


                                                              A


                                                              1

                                                                       DC 3.3V
                                 [Used for test setup]        B         2
                                                              C
                                       3           E
                             F                                D
                                                                                   G

                         4                                                             5
                                                                                                           [CVCF]

                      AC 120V/60Hz                                             AC 120V/60Hz              [Used for Radiated emission test]
                                                                    [Used for Conducted emission test]
                 : Standard Ferrite Core
* Cabling and setup were taken into consideration and test data was taken under worse case conditions.

Description of EUT and Support equipment
 No. Item                  Model number                  Serial number                       Manufacturer        Remark

 A     Antenna Board                  QXXAVC922-B        1                                   SANYO               EUT
 B     WLAN Module                    QXXAVC922---P      1                                   SANYO               EUT
 C     Printed Circuit Board          -                  -                                   SANYO               -
 D     PC Card                        -                  J030602A                            SANYO               -
 E     Note PC                        1952-D65           L3-DM297                            lenovo              -
 F     AC Adapter                     92P1160            11S92P1160Z1ZBGH6B6DM7              lenovo              -
 G     DC Power Supply                PW18-1.3AT         08016530                            KENWOOD             -
                                                                                             TMI

List of cables used
 No.     Name                              Length (m)                            Shield
                                                                    Cable                    Connector
 1       Antenna Cable            0.2                             Unshielded                 Unshielded
 2                                2.0 *1)                         Unshielded                 Unshielded
        DC Cable
                                  3.5 *2)
 3      DC Cable                  1.8                             Unshielded                 Unshielded
 4      AC Cable                  1.0                             Unshielded                 Unshielded
 5      AC Cable                  1.8                             Unshielded                 Unshielded
*1) Used for Conducted emission test.
*2) Used for Radiated emission test.


UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                               Test report No.   : 27KE0187-HO-A-R1
                                                                               Page              : 10 of 56
                                                                               Issued date       : October 12, 2007
                                                                               Revised date      : October 26, 2007
                                                                               FCC ID            : NPKAVC922


SECTION 5: Conducted Emission

Test Procedure and conditions

EUT was placed on a urethane platform of nominal size, 0.5m by 1.0m, raised 80cm above the conducting ground plane.
The rear of tabletop was located 40cm to the vertical conducting plane. The rear of EUT, including peripherals aligned
and flushed with rear of tabletop. All other surfaces of tabletop were at least 80cm from any other grounded conducting
surface. EUT was located 80cm from a Line Impedance Stabilization Network (LISN)/ Artificial mains Network
(AMN) and excess AC cable was bundled in center.

For the tests on EUT with other peripherals (as a whole system)
I/O cable and AC cables that were connected to the peripherals were bundled in center. They were folded back and forth
forming a bundle 30cm to 40cm long and were hanged at a 40cm height to the ground plane. All unused 50ohm
connectors of the LISN(AMN) were resistivity terminated in 50ohm when not connected to the measuring equipment.

The AC Mains Terminal Continuous disturbance Voltage has been measured with the EUT in a Semi Anechoic
Chamber.
The EUT was connected to a LISN (AMN).
An overview sweep with peak detection has been performed.

Detector                           : quasi-peak and average detector (IF BW 9 kHz)
Measurement range                  : 0.15-30MHz
Test data                          : APPENDIX 2
Test result                        : Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                                 Test report No.   : 27KE0187-HO-A-R1
                                                                                 Page              : 11 of 56
                                                                                 Issued date       : October 12, 2007
                                                                                 Revised date      : October 26, 2007
                                                                                 FCC ID            : NPKAVC922




SECTION 6: Spurious Emission
[Conducted]
Test Procedure
The Out of Band Emission was measured with a spectrum analyzer connected to the antenna port.
Test data                       : APPENDIX 2
Test result                     : Pass

[Radiated]
Test Procedure
EUT was placed on a urethane platform of nominal size, 0.5m by 1.0m, raised 80cm above the conducting ground plane.
The Radiated Electric Field Strength intensity has been measured in a Semi Anechoic Chamber with a ground plane and
at a distance of 3m(Below 10GHz) and 1m(Upper 10GHz).
The height of the measuring varied between 1 and 4m and EUT was rotated a full revolution in order to obtain the
maximum value of the electric field intensity.
The measurements were performed for both vertical and horizontal antenna polarization with the Test Receiver, or the
Spectrum Analyzer (in linear mode).
The test was made with the detector (RBW/VBW) in the following table.
When using Spectrum analyzer, the test was made with adjusting span to zero by using peak hold.

In any 100kHz bandwidth outside the frequency band in which the spread spectrum intentional radiator is operating,
the radio frequency power that is produced by the intentional radiator confirmed 20dB below that in the 100kHz
bandwidth within the band that contains the highest level of the desired power, based on a radiated measurement.

20dBc was applied to the frequency over the limit of FCC 15.209 / Table 2 of RSS-210 2.7 (IC) and outside the
restricted band of FCC15.205 / Table 1 of RSS-210 2.7 (IC).
   Frequency          Below 1GHz                                  Above 1GHz
   Instrument used    Test Receiver / Spectrum Analyzer           Spectrum Analyzer
   Detector           QP: BW 120kHz(T/R)                          PK: RBW:1MHz/VBW: 1MHz
   IF Bandwidth       20dBc : RBW: 100kHz                         AV: RBW:1MHz/VBW:10Hz
                             VBW: 300kHz (S/A)                    20dBc : RBW:100kHz/VBW:300kHz

- The carrier level and noise levels were confirmed at each position of X, Y and Z axes of EUT to see the position of
maximum noise, and the test was made at the position that has the maximum noise.

Test data                           : APPENDIX 2
Test result                         : Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                             Test report No.   : 27KE0187-HO-A-R1
                                                                             Page              : 12 of 56
                                                                             Issued date       : October 12, 2007
                                                                             Revised date      : October 26, 2007
                                                                             FCC ID            : NPKAVC922




SECTION 7: 6dB Bandwidth
Test Procedure

The bandwidth was measured with a spectrum analyzer connected to the antenna port.

Test data                         : APPENDIX 2
Test result                       : Pass

SECTION 8: Maximum Peak Output Power
Test Procedure

The Maximum Peak Output Power was measured with a power meter (tested bandwidth: 50MHz) connected to the
antenna port.
It was measured based on "Power Output Option 1" of "Guidance on Measurement of Digital Transmission Systems
Operating under Section15.247 ".

Test data                         : APPENDIX 2
Test result                       : Pass



SECTION 9: Peak Power Density

[Conducted]
Test Procedure
The Peak Power Density was measured with a spectrum analyzer connected to the antenna port.
It was measured based on "PSD Option 1" of "Guidance on Measurement of Digital Transmission Systems Operating under
Section15.247 ".

Test data                         : APPENDIX 2
Test result                       : Pass




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124



Document Created: 2007-10-26 17:17:59
Document Modified: 2007-10-26 17:17:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC