test report

FCC ID: NP8SCBS-519L1SHIR

Test Report

Download: PDF
FCCID_570242

Nemko Test Report No.:   5L0262RUS1


Applicant:               Samsung Telecommunications America
                         1301 E. Lookout Drive
                         Richardson, TX75081


Equipment Under Test:    SCBS-519L1 SHIR1 V.5 Indoor Base Station

FCC ID.                  NP8SCBS-519L1SHIR1

In Accordance With:      FCC Part 24, Subpart E
                         Broadband PCS Base Station Transmitter


Tested By:               Nemko U.S.A., Inc.
                         802 N. Kealy
                         Lewisville, Texas 75057-3136




Authorized By:           Tom Tidwell, Frontline Group Manager


Date:                    29 June, 2005


Nemko U.S.A., Inc                             FCC PART 24, SUBPART E
                            BROADBAND PCS BASE STATION TRANSMITTER
 EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1

                                                    Table of Contents

Section 1.          Summary of Test Results ....................................................................................... 3

Section 2.          General Equipment Specification .......................................................................... 5

Section 3.          RF Power Output ................................................................................................... 7

Section 4.          Occupied Bandwidth.............................................................................................. 8

Section 5.          Spurious Emissions at Antenna Terminals .......................................................... 10

Section 6.          Field Strength of Spurious ................................................................................... 14

Section 7.          Frequency Stability .............................................................................................. 16

Section 8.          Test Equipment List............................................................................................. 18

ANNEX A - TEST DETAILS ...................................................................................................... 19

ANNEX B - TEST DIAGRAMS.................................................................................................. 25




                                                                                                                       Page 2 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


Section 1.                Summary of Test Results

Manufacturer:             Samsung

Model No.:                SCBS-519L1 SHIR1 V.5

Serial No.:               None

General:                  All measurements are traceable to national standards.

These tests were conducted on a sample of the equipment for the purpose of demonstrating
compliance with FCC Part 24, Subpart E.

                 New Submission                                                     Production Unit

                 Class II Permissive Change                                         Pre-Production Unit


                  THIS TEST REPORT RELATES ONLY TO THE ITEM(S) TESTED.

 THE FOLLOWING DEVIATIONS FROM, ADDITIONS TO, OR EXCLUSIONS FROM THE TEST
                  SPECIFICATIONS HAVE BEEN MADE. NONE




 Nemko U.S.A. Inc. authorizes the above named company to reproduce this report provided it is reproduced in its
                            entirety and for use by the company’s employees only.

  Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the
 responsibility of such third parties. Nemko U.S.A. Inc. accepts no responsibility for damages, if any, suffered by
                     any third party as a result of decisions made or actions based on this report.

                                    This report applies only to the items tested.




                                                                                                      Page 3 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1

Summary Of Test Data


             NAME OF TEST                    PARA.         SPEC.      RESULT
                                              NO.
 RF Power Output                             24.232         100W      Complies
 Occupied Bandwidth (CDMA)                   24.238                   Complies
 Spurious Emissions at Antenna Terminals    24.238(a)     -13 dBm     Complies
                                                          -13 dBm
 Field Strength of Spurious Emissions       24.238(a)                 Complies
                                                           E.I.R.P.
 Frequency Stability                         24.235      ± 0.05 ppm   Complies



Footnotes For N/A’s:




Measurement uncertainty is expressed to a confidence level of 95%.




                                                                         Page 4 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


Section 2.              General Equipment Specification
Supply Voltage Input:                 27 Vdc supplied by off-the-shelf rectifier.

Frequency Bands:          TX                           1930 – 1945 MHz
                                           Block A :

                                           Block D :   1945 – 1950 MHz

                                           Block B :   1950 – 1965 MHz

                                           Block E :   1965 – 1970 MHz

                                           Block F :   1970 – 1975 MHz

                                           Block C :   1975 – 1990 MHz

Frequency Bands:          RX                           1850 – 1865 MHz
                                           Block A :

                                           Block B :   1865 – 1870 MHz

                                           Block C :   1870 – 1885 MHz

                                           Block D :   1885 – 1890 MHz

                                           Block E :   1890 – 1895 MHz

                                           Block F :   1895 – 1910 MHz

                                            CDMA                   GSM                 NADC
                                          (1M25F9W)            (200KGXW)            (40K0DXW)
Type of Modulation and Designator:


Output Impedance:                     50 ohms

RF Output (Rated):                    Per FA: 20W

                                           Software             Duplexer            Fullband
Band Selection:




                                                                                    Page 5 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1

System Description

The SCBS-519L V.5 Indoor Base Station is a 20 Watt CDMA PCS base station operating from
1941.25 to 1960 MHz




                                                                             Page 6 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


Section 3.           RF Power Output

NAME OF TEST: RF Power Output                            PARA. NO.: 2.1046

TESTED BY: David Light                                   DATE: 6/7/2005


Test Results:              Complies.

Measurement Data:


  Modulation Type        Measured Output     Measured Output
                             Power               Power
                             (dBm)                (W)
       CDMA                   43.5                22.4




Equipment Used:      1066-1472-1036


Measurement Uncertainty:        +/- 1.6 dB


Temperature:            22 °C

Relative Humidity:      40 %




                                                                          Page 7 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


Section 4.           Occupied Bandwidth

NAME OF TEST: Occupied Bandwidth (CDMA)            PARA. NO.: 2.1049

TESTED BY: David Light                             DATE: 6/7/2005


Test Results:              Complies.

Test Data:                 See attached plot(s).


Equipment Used:      1066-1472-1036


Measurement Uncertainty:       +/- 1.6 dB


Temperature:          22 °C

Relative Humidity:     40 %




                                                                    Page 8 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1

Test Data – 26 dB Bandwidth




                                                          Page 9 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


Section 5.           Spurious Emissions at Antenna Terminals

NAME OF TEST: Spurious Emissions @ Antenna Terminals   PARA. NO.: 2.1051

TESTED BY: David Light                                 DATE: 6/7/2005


Test Results:              Complies.

Test Data:

Equipment Used:      1066-1472-1036


Measurement Uncertainty:       +/- 1.6 dB


Temperature:          22 °C

Relative Humidity:     40 %




                                                                        Page 10 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1

Test Data – Spurious Emissions at Antenna Terminal




Lowest operating channel




                                                         Page 11 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1

Test Data – Spurious Emissions at Antenna Terminal




Highest operating channel




                                                         Page 12 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1

Test Data – Spurious Emissions at Antenna Terminal




Center channel




                                                         Page 13 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


Section 6.           Field Strength of Spurious

NAME OF TEST: Field Strength of Spurious Emissions            PARA. NO.: 2.1051

TESTED BY: David Light                                        DATE: 6/7/2005


Test Results:               Complies.


Test Data:                  There were no emissions detected above the noise floor which was
                            at least 30 dB below the specification limit of -13 dBm. The
                            spectrum was searched from 30 MHz to 20 GHz..

Equipment Used:      1036-1016-1484-1485-1304-791-1982-760-759


Measurement Uncertainty:       +/- 1.6 dB


Temperature:          22 °C

Relative Humidity:     40 %




                                                                               Page 14 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1

Photographs of Test Setup




                                                         Page 15 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


Section 7.          Frequency Stability

NAME OF TEST: Frequency Stability                        PARA. NO.: 2.1055

TESTED BY: David Light                                   DATE: 6/9/2005


Test Results:            Complies


Measurement Data:        Standard Test Frequency: 1946.25 MHz
                         Standard Test Voltage: 27 Vdc




                                                                          Page 16 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1

Test Data – Frequency Stability
                                                         Frequency Stability
          Page 1 of 1
Job No.:                5L0262R                              Date: 6/9/2005
Specification:        Part 24                    Temperature(°C): 20
Tested By:            David Light            Relative Humidity(%) 50
E.U.T.:                                        Indoor base station
Configuration:                             Tx CDMA signal at mid band
Sample Number:              1
                                            Test Equipment Used
Antenna:                                                      Directional Coupler:
Pre-Amp:                                                                Cable #1:     1484
Filter:                                                                 Cable #2:
Receiver:                 1036
Attenuator #1             1472
Attenuator #2:

Measurement
Uncertainty:          1x10-17ppm                  Standard Test Frequency               1946.250000     MHz

                            Measured           Rho    Test   Freqeuncy               Limit      Error
Temp           (OC)
                         Frequency (MHz)             Voltage Error (Hz)              (+/-Hz)   (ppm)          Comment
          20                1946.250055       0.9980   27        55                   973.1    0.028
          20                1946.250053       0.9982  23.0       53                   973.1    0.027
          20                1946.250047       0.9981  31.0       47                   973.1    0.024

          50                1946.250057       0.9978       27            57          973.1      0.029
          40                1946.250034       0.9983       27            34          973.1      0.017
          30                1946.250031       0.9981       27            31          973.1      0.016

          10                1946.250049       0.9982      27.0           49          973.1      0.025
           0                1946.250032       0.9982      27.0           32          973.1      0.016
          -10               1946.250065       0.9980      27.0           65          973.1      0.033
          -20               1946.250031       0.9980       27            31          973.1      0.016
          -30               1946.250036       0.9981       27            36          973.1      0.018
            Notes:




                                                                                                              Page 17 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


Section 8.         Test Equipment List
Nemko ID           Description              Manufacturer     Serial Number   Calibration Calibration
                                           Model Number                         Date        Due
  1036        SPECTRUM ANALYZER          ROHDE & SCHWARZ      830844/006      03/22/04    03/23/06
                                              FSEK30
  1484         Cable 2.0-18.0 Ghz               Storm            N/A          08/26/04    08/26/05
                                           PR90-010-072
  1472       20db Attenuator DC 18 Ghz      Omni Spectra        NONE            CBU          N/A
                                             20600-20db
  1036        SPECTRUM ANALYZER          ROHDE & SCHWARZ      830844/006      03/22/04    03/23/06
                                              FSEK30
  1485         Cable 2.0-18.0 Ghz               Storm            N/A          08/02/04    08/02/05
                                           PR90-010-216
  1016               Pre-Amp             HEWLETT PACKARD      2749A00159      11/12/04    11/12/05
                                                8449A
  1304           HORN ANTENNA            ELECTRO METRICS         6151         09/22/03    09/22/05
                                               RGA-60
  759        ANTENNA, LOG PERIODIC         A.H. SYSTEMS          556          07/23/04    07/23/05
                                            SAS-200/510
  760            Antenna biconical         Electro Metrics       477          06/22/04    06/22/05
                                               MFC-25
  791             PREAMP, 25dB                   ICC             398          11/12/04    11/12/05
                                               LNA25
  1982              CABLE, 7m                    KTL             N/A          10/25/00       N/A
                                               RG223
  1066              CABLE, 4M                  STORM             N/A          08/26/04    08/26/05
                                           PR90-010-144
                   Chart recorder                Unk                          03/04/05    03/04/06
                  ETL Asset 1244                 Unk
                  Temp controller                Unk                          11/19/04    11/19/05
                  ETL asset 1154                 Unk




                                                                                  Page 18 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1




                    ANNEX A - TEST DETAILS




                                                         Page 19 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


NAME OF TEST: RF Power Output                                      PARA. NO.: 2.1046


Minimum Standard:           Para. No.24.232. Base stations are limited to 1640 watts peak
                            E.I.R.P. with an antenna height up to 300 meters HAAT. In no
                            case may the peak output power of a base station transmitter
                            exceed 100 watts.

Method Of Measurement: CDMA Per ANSI/J-STD-014
                       TDMA Per ANSI/J-STD-010

Detachable Antenna:
The peak power at antenna terminals is measured using an in-line peak power meter or a
spectrum analyzer.




                                                                                 Page 20 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


NAME OF TEST: Occupied Bandwidth                                    PARA. NO.: 2.1049


Minimum Standard:             Para. No. 24.238(b). The emission bandwidth is defined as the
                              width of the signal between two points, one below the carrier
                              center frequency and one above the carrier center frequency,
                              outside of which all emissions are attenuated at least 26 dB.

Method Of Measurement:

CDMA Per ANSI/J-STD-014

Spectrum analyzer settings:
RBW: 30 kHz
VBW: ≥ RBW
Span: 5 MHz
Sweep: Auto

GSM Per ANSI/J-STD-010

RBW: 3 kHz
VBW: ≥ RBW
Span: 2 MHz
Sweep: Auto

NADC Per IS-136

RBW: 1 kHz
VBW: ≥ RBW
Span: 1 MHz
Sweep: Auto




                                                                                  Page 21 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


NAME OF TEST: Spurious Emission at Antenna Terminals                PARA. NO.: 2.1051


Minimum Standard:             Para. No.24.238(a). On any frequency outside a licensee’s
                              frequency block, the power of any emission shall be attenuated
                              below the transmitter power by at least 43 + 10 log (P) dB.

Method Of Measurement:

Spectrum analyzer settings:

CDMA Per ANSI/J-STD-014                          GSM Per ANSI/J-STD-010

RBW: 1 MHz (> 1 MHz from Band Edge)              RBW: 1 MHz (> 1 MHz from Band Edge)
RBW: 30 kHz (< 1MHz from Band Edge)              RBW: 3 kHz (< 1 MHz from Band Edge)
VBW: ≥ RBW                                       VBW: ≥ RBW
Sweep: Auto                                      Sweep: Auto
Video Avg: 6 Sweeps                              Video Avg: Disabled

NADC Per IS-136

RBW: 1 MHz (> 1 MHz from Band Edge)
RBW: 1 kHz (< 1 MHz from Band Edge)
VBW: ≥ RBW
Sweep: Auto
Video Avg: Disabled


To demonstrate compliance at band edges the frequency of the input signal is set to the lowest
and highest assigned channel and the center frequency of the spectrum analyzer is set to the
upper and lower edges of the appropriate frequency block.




                                                                                  Page 22 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


NAME OF TEST: Field Strength of Spurious Radiation                      PARA. NO.: 2.1053


Minimum Standard:              Para. No.24.238(a). On any frequency outside a licensee’s
                               frequency block, the power of any emission shall be attenuated
                               below the transmitter power by at least 43 + 10 log (P) dB.


Test Method:

The maximum field strength of the spurious emission is measured at a distance of 3 meters. The
device under test is then replaced with a substitution antenna of known gain with respect to an
isotropic radiator. A calibrated signal source is used to feed the substitution antenna. The rf
level to the substitution antenna is adjusted to repeat the previously measured field strength. The
rf input level to the substitution antenna is the effective isotropic power of the spurious emission.




                                                                                      Page 23 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1


NAME OF TEST: Frequency Stability                                    PARA. NO.: 2.1055


Minimum Standard:            Para. No. 24.235. The frequency stability shall be sufficient to
                             ensure that the fundamental emission stays within the authorized
                             frequency block.

Method Of Measurement: CDMA Per ANSI/J-STD-014
                       TDMA Per ANSI/J-STD-010
                       NADC Per IS-136

Frequency Stability With Voltage Variation

The E.U.T. is placed in an environmental chamber and allowed to stabilize at +20 degrees
Celsius for at least 15 minutes. With the voltage input to the E.U.T. set to 85% S.T.V., the
frequency is measured in 30 second intervals for a period of 5 minutes. This procedure is
repeated at 100% S.T.V. and 115% S.T.V.


Frequency Stability With Temperature Variation

The input voltage to the E.U.T. is set to S.T.V. and the temperature of the environmental
chamber is varied in 10 degree steps from -30 degrees C to +50 degrees C. The E.U.T. is
allowed to stabilize at each temperature and the frequency is measured in 30 second intervals for
a period of 5 minutes.




                                                                                   Page 24 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1




                    ANNEX B - TEST DIAGRAMS




                                                         Page 25 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1

Para. No. 2.985 - R.F. Power Output




                                                   Millivoltmeter




                                       Insertion     50 ohm
                EUT
                                         Unit         Load




Para. No. 2.989 - Occupied Bandwidth



                                                        Spectrum
             EUT                      Attenuator
                                                        Analyzer




                                                                    Page 26 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1

Para. No. 2.991 Spurious Emissions at Antenna Terminals



                                        EUT




                                     Attenuator




                                      Spectrum
                                      Analyzer




Para. No. 2.993 - Field Strength of Spurious Radiation

                                 3 METERS




                                 SEARCH ANTENNA




                                                                     VARIABLE
                                                                      SEARCH
                 E.U.T.                                           HEIGHT (1 TO 4 m)
    0.8 METER

                              NON-CONDUCTING
                                TURN-TABLE




                                                          TO TEST RECEIVER/SPECTRUM
                                                          ANALYZER




                                                                      Page 27 of 28


Nemko U.S.A., Inc                            FCC PART 24, SUBPART E
                           BROADBAND PCS BASE STATION TRANSMITTER
EQUIPMENT: SCBS-519L1 SHIR1 V.5            Test Report: 5L0262RUS1

Para. No. 2.995 - Frequency Stability



               Climate Chamber


                    E.U.T.              Attenuator




                                                        Frequency
                                                     Counter / Test Set




                                                                Page 28 of 28



Document Created: 2005-08-01 07:07:21
Document Modified: 2005-08-01 07:07:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC