Test Report

FCC ID: NMTRTGR328NA-01

Test Report

Download: PDF
FCCID_424038

                                                          IDT Technology Limited


                                                                Application
                                                                    For
                                                                Certification
                                                         (FCC ID: NMTTHN122-01)

                                                                           Transmitter




0402555
TL/ Sandy
March 30, 2004


•   The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample
    may be said to have been obtained.


•   This report shall not be reproduced except in full without prior authorization from Intertek Testing Services Hong Kong Limited.


•   For Terms And Conditions of the services, it can be provided upon request.


•   The evaluation data of the report will be kept for 3 years from the date of issuance.




                                                   Intertek Testing Services Hong Kong Ltd.
                                           2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong.
                                  Tel: (852) 2173 8888 Fax: (852) 2371 0521 Website: www.hk.intertek-etlsemko.com


                   INTERTEK TESTING SERVICES


                             LIST OF EXHIBITS

                INTRODUCTION

                EXHIBIT 1:             General Description

                EXHIBIT 2:             System Test Configuration

                EXHIBIT 3:             Emission Results

                EXHIBIT 4:             Equipment Photographs

                EXHIBIT 5:             Product Labelling

                EXHIBIT 6:             Technical Specifications

                EXHIBIT 7:             Instruction Manual

                EXHIBIT 8:             Miscellaneous Information




FCC ID: NMTTHN122-01
                                                                   i


                         INTERTEK TESTING SERVICES

                      MEASUREMENT/TECHNICAL REPORT

                   IDT Technology Limited - MODEL: THN122

                                FCC ID: NMTTHN122-01

                                     March 30, 2004




     This report concerns (check one:) Original Grant X              Class II Change

     Equipment Type: Low Power Transmitter (example: computer, printer, modem, etc.)


     Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes                      No X

                                                   If yes, defer until:
                                                                                 date
     Company Name agrees to notify the Commission by:
                                                              date

     of the intended date of announcement of the product so that the grant can be
     issued on that date.


     Transition Rules Request per 15.37?                     Yes                   No X

     If no, assumed Part 15, Subpart C for intentional radiator - the new 47 CFR [12-08-03
     Edition] provision.


     Report prepared by:                                   Tommy Leung
                                                           Intertek Testing Services
                                                           2/F., Garment Center,
                                                           576, Castle Peak Road,
                                                           HONG KONG.
                                                           Phone: 852-2173-8539
                                                           Fax: 852-2371-0521




FCC ID: NMTTHN122-01
                                                                                             ii


                                    INTERTEK TESTING SERVICES



                                                Table of Contents

1.0 General Description ............................................................................................ 2
  1.1 Product Description ............................................................................................ 2
  1.2 Related Submittal(s) Grants ............................................................................... 2
  1.3 Test Methodology............................................................................................... 3
  1.4 Test Facility........................................................................................................ 3

2.0 System Test Configuration ................................................................................. 5
  2.1 Justification ........................................................................................................ 5
  2.2 EUT Exercising Software.................................................................................... 5
  2.3 Special Accessories ........................................................................................... 5
  2.4 Equipment Modification ...................................................................................... 6
  2.5 Measurement Uncertainty .................................................................................. 6
  2.6 Support Equipment List and Description ............................................................. 6

3.0 Emission Results ................................................................................................ 8
  3.1 Field Strength Calculation................................................................................... 9
  3.2 Radiated Emission Configuration Photograph................................................... 11
  3.3 Radiated Emission Data ................................................................................... 12

4.0 Equipment Photographs................................................................................... 15

5.0 Product Labelling .............................................................................................. 17

6.0 Technical Specifications................................................................................... 19

7.0 Instruction Manual ............................................................................................ 21

8.0 Miscellaneous Information ............................................................................... 23
  8.1 Measured Bandwidth........................................................................................ 24
  8.2 Discussion of Pulse Desensitization.................................................................. 25
  8.3 Calculation of Average Factor........................................................................... 26
  8.4 Emissions Test Procedures .............................................................................. 27




FCC ID: NMTTHN122-01
                                                                                                                            iii


                        INTERTEK TESTING SERVICES



                              List of attached file

      Exhibit type                File Description             filename
Test Report             Test Report                   report.pdf
Operation Description   Technical Description         descri.pdf
Test Setup Photo        Radiated Emission             radiated photos.doc
Test Report             Bandwidth Plot                bw.pdf
External Photo          External Photo                external photos.doc
Internal Photo          Internal Photo                internal photos.doc
Block Diagram           Block Diagram                 block.pdf
Schematics              Circuit Diagram               circuit.pdf
ID Label/Location       Label Artwork and Location    label.pdf
User Manual             User Manual                   manual.pdf
Test Report             Timing Diagram                timing.pdf




FCC ID: NMTTHN122-01
                                                                            iv


                   INTERTEK TESTING SERVICES



                            EXHIBIT 1

                       GENERAL DESCRIPTION




FCC ID: NMTTHN122-01
                                               1


                          INTERTEK TESTING SERVICES

1.0   General Description

1.1   Product Description

      The Equipment Under Test (EUT) is a transmitter operating at 433.9MHz. The
      EUT is powered by 3.0d.c (2 x 1.5V “AAA” size alkaline batteries). During
      normal use, it will transmit temperature signal to the corresponding receiver and
      the temperature will be displayed on the receiver when channel selection is the
      same. Also, it employs a channel switch which allows user to select one of
      three channels. The duration of each transmission is 391.25ms and the silent
      period between transmission is 29.125 seconds.

      Antenna Type : Integral, Internal

      For electronic filing, the brief circuit description is saved with filename: descri.pdf.


1.2   Related Submittal(s) Grants

      This is an application for certification of a transmitter. The receiver, associated
      with this transmitter, is subjected to DOC procedure.




FCC ID: NMTTHN122-01
                                                                                             2


                         INTERTEK TESTING SERVICES

1.3   Test Methodology

      Radiated emission measurements were performed according to the procedures
      in ANSI C63.4 (2001). All measurements were performed in Open Area Test
      Sites. Preliminary scans were performed in the Open Area Test Sites only to
      determine worst case modes. For each scan, the procedure for maximizing
      emissions in Appendices D and E were followed. All Radiated tests were
      performed at an antenna to EUT distance of 3 meters, unless stated otherwise
      in the “Justification Section” of this Application.


1.4   Test Facility

      The open area test site and conducted measurement facility used to collect the
      emission data is located at Garment Centre, 576 Castle Peak Road, Kowloon,
      Hong Kong. This test facility and site measurement data have been fully placed
      on file with the FCC.




FCC ID: NMTTHN122-01
                                                                                  3


                   INTERTEK TESTING SERVICES



                           EXHIBIT 2

                   SYSTEM TEST CONFIGURATION




FCC ID: NMTTHN122-01
                                               4


                         INTERTEK TESTING SERVICES

2.0   System Test Configuration

2.1   Justification

      The system was configured for testing in a typical fashion (as a customer would
      normally use it), and in the confines as outlined in ANSI C63.4 (2001).

      The EUT was powered from 2 x new 1.5V "AAA" batteries.

      For maximizing emissions, the EUT was rotated through 360°, the antenna
      height was varied from 1 meter to 4 meters above the ground plane, and the
      antenna polarization was changed. This step by step procedure for maximizing
      emissions led to the data reported in Exhibit 3.0.

      The unit was operated standalone and placed in the center of the turntable.

      The equipment under test (EUT) was configured for testing in a typical fashion
      (as a customer would normally use it). The EUT was placed on turntable, which
      enabled the engineer to maximize emissions through its placement in the three
      orthogonal axes. For simplicity of testing, the unit was wired to transmit
      continuously.

      The frequency range from 433.9MHz to 4.34GHz was searched for spurious
      emissions from the device. Only those emissions reported were detected. All
      other emissions were at least 20 dB below the applicable limits.


2.2   EUT Exercising Software

      There was no special software to exercise the device. Once the button is
      depressed, the unit transmits the typical signal. For simplicity of testing, the unit
      was wired to transmit continuously.


2.3   Special Accessories

      There are no special accessories necessary for compliance of this product.




FCC ID: NMTTHN122-01
                                                                                         5


                         INTERTEK TESTING SERVICES

2.4   Equipment Modification

      Any modifications installed previous to testing by IDT Technology Limited will be
      incorporated in each production model sold/leased in the United States.

      No modifications were installed by Intertek Testing Services.


2.5   Measurement Uncertainty

      When determining of the test conclusion, the Measurement Uncertainty of test
      has been considered.


2.6   Support Equipment List and Description

      This product was tested in a standalone configuration.

      All the items listed under section 2.0 of this report are

      Confirmed by:

                    Tommy Leung
                    Supervisor
                    Intertek Testing Services Hong Kong Ltd.
                    Agent for IDT Technology Limited




                                                         Signature

                             March 30, 2004              Date




FCC ID: NMTTHN122-01
                                                                                     6


                   INTERTEK TESTING SERVICES



                           EXHIBIT 3

                       EMISSION RESULTS




FCC ID: NMTTHN122-01
                                               7


                        INTERTEK TESTING SERVICES

3.0   Emission Results

      Data is included worst case configuration (the configuration which resulted in the
      highest emission levels). A sample calculation, configuration photographs and
      data tables of the emissions are included.




FCC ID: NMTTHN122-01
                                                                                      8


                        INTERTEK TESTING SERVICES

3.1   Field Strength Calculation

      The field strength is calculated by adding the reading on the Spectrum Analyzer
      to the factors associated with preamplifiers (if any), antennas, cables, pulse
      desensitization and average factors (when specified limit is in average and
      measurements are made with peak detectors). A sample calculation is included
      below.

      FS = RA + AF + CF - AG + PD + AV

      where FS = Field Strength in dBµV/m
                  RA = Receiver Amplitude (including preamplifier) in dBµV
                  CF = Cable Attenuation Factor in dB
                  AF = Antenna Factor in dB
                  AG = Amplifier Gain in dB
                  PD = Pulse Desensitization in dB
                  AV = Average Factor in -dB



      In the radiated emission table which follows, the reading shown on the data
      table may reflect the preamplifier gain. An example of the calculations, where
      the reading does not reflect the preamplifier gain, follows:


      FS = RA + AF + CF - AG + PD + AV




FCC ID: NMTTHN122-01
                                                                                   9


                        INTERTEK TESTING SERVICES

3.1   Field Strength Calculation (cont’d)

      Example
      Assume a receiver reading of 62.0 dBµV is obtained. The antenna factor of 7.4
      dB and cable factor of 1.6 dB is added. The amplifier gain of 29 dB is
      subtracted. The pulse desensitization factor of the spectrum analyzer was 0 dB,
      and the resultant average factor was -10 dB. The net field strength for
      comparison to the appropriate emission limit is 32 dBµV/m. This value in
      dBµV/m was converted to its corresponding level in µV/m.

      RA = 62.0 dBµV
      AF = 7.4 dB
      CF = 1.6 dB
      AG = 29.0 dB
      PD = 0 dB

      AV = -10 dB

      FS = 62 + 7.4 + 1.6 - 29 + 0 + (-10) = 32 dBµV/m

      Level in µV/m = Common Antilogarithm [(32 dBµV/m)/20] = 39.8 µV/m




FCC ID: NMTTHN122-01
                                                                                  10


                        INTERTEK TESTING SERVICES

3.2   Radiated Emission Configuration Photograph

                            Worst Case Radiated Emission
                                        at
                                    433.900 MHz


      For electronic filing, the worst case radiated emission configuration photograph
      is saved with filename: radiated photos.doc.




FCC ID: NMTTHN122-01
                                                                                   11


                       INTERTEK TESTING SERVICES

3.3   Radiated Emission Data

      The data on the following page lists the significant emission frequencies, the
      limit and the margin of compliance. Numbers with a minus sign are below the
      limit.


                            Judgement: Passed by 5.3 dB


      TEST PERSONNEL:




      Signature



      Ben W. K. Ho, Compliance Engineer
      Typed/Printed Name


      March 30, 2004
      Date




FCC ID: NMTTHN122-01
                                                                                 12


                        INTERTEK TESTING SERVICES

Company: IDT Technology Limited                      Date of Test: February 25, 2004
Model: THN122

                                          Table 1

                                   Radiated Emissions

Polarization Frequency Reading Antenna Pre- Average  Net   Limit  Margin
               (MHz)   (dBµV) Factor Amp Factor     at 3m  at 3m   (dB)
                                (dB) Gain (-dB) (dBµV/m) (dBµV/m)
                                       (dB)
     V        433.900   72.3    16.3    16    5.1    67.5   72.8   -5.3
     V        867.817   38.3    22.2    16    5.1    39.4   52.8  -13.4
     V       1301.722   24.9    25.5    16    5.1    29.3   52.8  -23.5
     V       1735.629   25.1    26.5    16    5.1    30.5   52.8  -22.3
     V       2169.540   22.9    29.1    16    5.1    30.9   52.8  -21.9
     V       2603.440   20.9    29.1    16    5.1    28.9   52.8  -23.9


Notes: 1. Peak Detector Data unless otherwise stated.

        2. All measurements were made at 3 meter. Harmonic emissions not detected
           at the 3-meter distance were measured at 0.3-meter and an inverse
           proportional extrapolation was performed to compare the signal level to the
           3-meter limit. No other harmonic emissions than those reported were
           detected at a test distance of 0.3-meter.

        3. Negative value in the margin column shows emission below limit.

        4. Horn antenna is used for the emission over 1000MHz.




Test Engineer: Ben W. K. Ho




FCC ID: NMTTHN122-01
                                                                                  13


                   INTERTEK TESTING SERVICES



                             EXHIBIT 4

                       EQUIPMENT PHOTOGRAPHS




FCC ID: NMTTHN122-01
                                               14


                        INTERTEK TESTING SERVICES

4.0   Equipment Photographs

      For electronic filing, the photographs of the tested EUT are saved with filename:
      external photos.doc & internal photos.doc.




FCC ID: NMTTHN122-01
                                                                                    15


                   INTERTEK TESTING SERVICES



                           EXHIBIT 5

                       PRODUCT LABELLING




FCC ID: NMTTHN122-01
                                               16


                        INTERTEK TESTING SERVICES

5.0   Product Labelling

      For electronic filing, the FCC ID label artwork and the label location are saved
      with filename: label.pdf.




FCC ID: NMTTHN122-01
                                                                                   17


                   INTERTEK TESTING SERVICES



                               EXHIBIT 6

                       TECHNICAL SPECIFICATIONS




FCC ID: NMTTHN122-01
                                                  18


                       INTERTEK TESTING SERVICES

6.0   Technical Specifications

      For electronic filing, the block diagram and schematics of the tested EUT are
      saved with filename: block.pdf and circuit.pdf respectively.




FCC ID: NMTTHN122-01
                                                                                19


                   INTERTEK TESTING SERVICES



                            EXHIBIT 7

                       INSTRUCTION MANUAL




FCC ID: NMTTHN122-01
                                               20


                        INTERTEK TESTING SERVICES

7.0   Instruction Manual

      For electronic filing, a preliminary copy of the Instruction Manual is saved with
      filename: manual.pdf.

      This manual will be provided to the end-user with each unit sold/leased in the
      United States.




FCC ID: NMTTHN122-01
                                                                                    21


                   INTERTEK TESTING SERVICES



                           EXHIBIT 8

                  MISCELLANEOUS INFORMATION




FCC ID: NMTTHN122-01
                                               22


                       INTERTEK TESTING SERVICES

8.0   Miscellaneous Information

      This miscellaneous information includes details of the measured bandwidth, the
      test procedure and calculation of factors such as pulse desensitization and
      averaging factor.




FCC ID: NMTTHN122-01
                                                                                 23


                        INTERTEK TESTING SERVICES

8.1   Measured Bandwidth

      For electronic filing, the plot shows the fundamental emission when modulated
      is saved with filename: bw.pdf. From the plot, the bandwidth is observed to be
      335 kHz, at 20 dBc where the bandwidth limit is 1084 kHz.

      Therefore, the unit meets the requirement of section 15.231(c).


                                Figure 8.1    Bandwidth




FCC ID: NMTTHN122-01
                                                                                 24


                        INTERTEK TESTING SERVICES

8.2   Discussion of Pulse Desensitization

      The determination of pulse desensitivity was made in accordance with Hewlett
      Packard Application Note 150-2, Spectrum Analysis ... Pulsed RF.

      The effective period (Teff) was approximately 1.688 ms for a digital "1" bit, as
      shown in the plots of Exhibit 8.3. With a resolution bandwidth (3 dB) of 100 kHz,
      the pulse desensitivity factor was 0 dB.




FCC ID: NMTTHN122-01
                                                                                    25


                        INTERTEK TESTING SERVICES

8.3   Calculation of Average Factor

      Averaging factor in dB = 20 log (duty cycle)

      The specification for output field strengths in accordance with the FCC rules
      specify measurements with an average detector. During testing, a spectrum
      analyzer incorporating a peak detector was used. Therefore, a reduction factor
      can be applied to the resultant peak signal level and compared to the limit for
      measurement instrumentation incorporating an average detector.

      The time period over which the duty cycle is measured is 100 milliseconds, or
      the repetition cycle, whichever is a shorter time frame. The worst case (highest
      percentage on) duty cycle is used for the calculation. The duty cycle is measured
      by placing the spectrum analyzer in zero scan (receiver mode) and linear mode
      at maximum bandwidth (3 MHz at 3 dB down) and viewing the resulting time domain
      signal output from the analyzer on a Tektronix oscilloscope. The oscilloscope is
      used because of its superior time base and triggering facilities.


      The duty cycle is simply the on-time divided by the period:

      The duration of one cycle = 100 ms
      Effective period of the cycle = (20 x 1.688 + 1 x 5.625 + 5 x 3.187) ms = 55.3 ms

      DC = 55.3 ms / 100 ms = 0.553

      Therefore, the averaging factor is found by 20 log10 0.553 = -5.1 dB

      For electronic filing, the plot shows the transmission timing is saved with
      filename: timing.pdf.




FCC ID: NMTTHN122-01
                                                                                    26


                         INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures

      The following is a description of the test procedure used by Intertek Testing Services
      in the measurements of transmitters operating under Part 15, Subpart C rules.

      The test set-up and procedures described below are designed to meet the
      requirements of ANSI C63.4 - 2001.

      The transmitting equipment under test (EUT) is placed on a wooden turntable
      which is four feet in diameter and approximately one meter in height above the
      ground plane. During the radiated emissions test, the turntable is rotated and
      any cables leaving the EUT are manipulated to find the configuration resulting in
      maximum emissions. The EUT is adjusted through all three orthogonal axes to
      obtain maximum emission levels. The antenna height and polarization are
      varied during the testing to search for maximum signal levels. The height of the
      antenna is varied from one to four meters.

      Detector function for radiated emissions is in peak mode. Average readings,
      when required, are taken by measuring the duty cycle of the equipment under
      test and subtracting the corresponding amount in dB from the measured peak
      readings. A detailed description for the calculation of the average factor can be
      found in Exhibit 8.3.

      The frequency range scanned is from the lowest radio frequency signal
      generated in the device which is greater than 9 kHz to the tenth harmonic of the
      highest fundamental frequency or 40 GHz, whichever is lower. For line
      conducted emissions, the range scanned is 150 kHz to 30 MHz.




FCC ID: NMTTHN122-01
                                                                                         27


                         INTERTEK TESTING SERVICES

8.4   Emissions Test Procedures (cont'd)


      The EUT is warmed up for 15 minutes prior to the test.

      AC power to the unit is varied from 85% to 115% nominal and variation in the
      fundamental emission field strength is recorded. If battery powered, a new, fully
      charged battery is used.

      Conducted measurements are made as described in ANSI C63.4 - 2001.

      The IF bandwidth used for measurement of radiated signal strength was 100 kHz
      or greater when frequency is below 1000 MHz. Where pulsed transmissions of
      short enough pulse duration warrant, a greater bandwidth is selected according
      to the recommendations of Hewlett Packard Application Note 150-2. A
      discussion of whether pulse desensitivity is applicable to this unit is included in
      this report (See Exhibit 8.2). Above 1000 MHz, a resolution bandwidth of 1 MHz
      is used.

      Transmitter measurements are normally conducted at a measurement distance
      of three meters. However, to assure low enough noise floor in the forbidden
      bands and above 1 GHz, signals are acquired at a distance of one meter or
      less. All measurements are extrapolated to three meters using inverse scaling,
      unless otherwise reported. Measurements taken at a closer distance are so
      marked.




FCC ID: NMTTHN122-01
                                                                                      28



Document Created: 2004-04-15 12:42:51
Document Modified: 2004-04-15 12:42:51

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC