SAR System validation

FCC ID: NM8TP

RF Exposure Info

Download: PDF
FCCID_465293

                                                          Date/Time: 07/16/03 01:57:14

Test Laboratory: Compliance Certification Services Inc.

SystemPerformanceCheck-D900
DUT: Dipole 900 MHz; Type: D900V2; Serial: 179

Communication System: CW; Frequency: 900 MHz;Duty Cycle: 1:1
Medium parameters used: f = 900 MHz; σ = 0.96 mho/m; εr = 41.2; ρ = 1000 kg/m3
Air Temperature:24.5 deg C;Liquid Temperature:23.5 deg C
Phantom section: Flat Section

DASY4 Configuration:

   z   Probe: ET3DV6 - SN1763; ConvF(6.46, 6.46, 6.46); Calibrated: 3/23/2004
   z   Sensor-Surface: 4mm (Mechanical Surface Detection)
       Sensor-Surface: 0mm (Fix Surface)
   z   Electronics: DAE3 Sn427; Calibrated: 3/15/2004
   z   Phantom: SAM 34; Type: SAM V4.0; Serial: TP-1150
   z   Measurement SW: DASY4, V4.2 Build 44; Postprocessing SW: SEMCAD, V1.8
       Build 112

d=15mm, Pin=250mW/Area Scan (6x6x1): Measurement grid: dx=15mm,
dy=15mm
Reference Value = 60.0 V/m; Power Drift = -0.0 dB
Maximum value of SAR (measured) = 2.74 mW/g

d=15mm, Pin=250mW/Z Scan (1x1x21): Measurement grid: dx=20mm,
dy=20mm, dz=5mm
Reference Value = 60.0 V/m; Power Drift = -0.0 dB
Maximum value of SAR (measured) = 1.54 mW/g

d=15mm, Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 60.0 V/m; Power Drift = -0.0 dB
Maximum value of SAR (measured) = 2.89 mW/g
Peak SAR (extrapolated) = 4.09 W/kg
SAR(1 g) = 2.68 mW/g; SAR(10 g) = 1.72 mW/g




                                                                                 Page1


Page2


                                                                         Date/Time: 08/23/04 17:01:26

Test Laboratory: Compliance Certification Services Inc.

D1800V2 SN-3
DUT: Dipole 1800 MHz; Type: D1800V2; Serial: D1800V2 - SN:2d062

Communication System: CW1800; Frequency: 1800 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1800 MHz; σ = 1.42 mho/m; εr = 38.9 ; ρ = 1000 kg/m3
Air Temperature:25.3 deg C;Liquid Temperature:24.3 deg C
Phantom section: Flat Section

DASY4 Configuration:

   z   Probe: ET3DV6 - SN1763; ConvF(5.34, 5.34, 5.34); Calibrated: 3/23/2004
   z   Sensor-Surface: 4mm (Mechanical Surface Detection)
   z   Electronics: DAE3 Sn427; Calibrated: 3/15/2004
   z   Phantom: SAM 34; Type: SAM V4.0; Serial: TP-1150
   z   Measurement SW: DASY4, V4.2 Build 44; Postprocessing SW: SEMCAD, V1.8 Build 112

Pin=250mW,d=10mm 2/Area Scan (6x6x1): Measurement grid: dx=15mm, dy=15mm
Reference Value = 94.9 V/m; Power Drift = 0.1 dB
Maximum value of SAR (measured) = 7.48 mW/g

Pin=250mW,d=10mm 2/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm,
dz=5mm
Reference Value = 94.9 V/m; Power Drift = 0.1 dB
Maximum value of SAR (measured) = 10.8 mW/g
Peak SAR (extrapolated) = 17.1 W/kg
SAR(1 g) = 9.61 mW/g; SAR(10 g) = 5.08 mW/g




                                                                                               Page1


                                                          Date/Time: 08/23/04 09:38:52

Test Laboratory: Compliance Certification Services Inc.

D1800V2 SN-3-Body
DUT: Dipole 1800 MHz; Type: D1800V2; Serial: D1800V2 - SN:2d062

Communication System: CW1800; Frequency: 1800 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1800 MHz; σ = 1.48 mho/m; εr = 54.1; ρ = 1000 kg/m3
Air Temperature:25.3 deg C;Liquid Temperature:24.3 deg C
Phantom section: Flat Section

DASY4 Configuration:

   z   Probe: ET3DV6 - SN1763; ConvF(4.66, 4.66, 4.66); Calibrated: 3/23/2004
   z   Sensor-Surface: 4mm (Mechanical Surface Detection)
       Sensor-Surface: 0mm (Fix Surface)
   z   Electronics: DAE3 Sn427; Calibrated: 3/15/2004
   z   Phantom: SAM 12; Type: SAM V4.0; Serial: TP-1150
   z   Measurement SW: DASY4, V4.2 Build 44; Postprocessing SW: SEMCAD, V1.8
       Build 112

Pin=250mW,d=10mm/Area Scan (6x6x1): Measurement grid: dx=15mm,
dy=15mm
Reference Value = 93.1 V/m; Power Drift = 0.1 dB
Maximum value of SAR (measured) = 7.57 mW/g

Pin=250mW,d=10mm/Z Scan (1x1x21): Measurement grid: dx=20mm,
dy=20mm, dz=5mm
Reference Value = 93.3 V/m; Power Drift = 0.1 dB
Maximum value of SAR (measured) = 8.65 mW/g

Pin=250mW,d=10mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 93.3 V/m; Power Drift = 0.1 dB
Maximum value of SAR (measured) = 10.9 mW/g
Peak SAR (extrapolated) = 15.9 W/kg
SAR(1 g) = 9.60 mW/g; SAR(10 g) = 5.18 mW/g




                                                                                Page1


Page2



Document Created: 2004-08-27 15:54:45
Document Modified: 2004-08-27 15:54:45

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC