SAR attachment 2 1

FCC ID: NM8TNDF

RF Exposure Info

Download: PDF
FCCID_577338

                                                     Date/Time: 7/14/2005 11:06:11 AMDate/Time: 7/14/2005 11:12:26 AM

Test Laboratory: Compliance Certification Services

Left Hand Side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 824.2 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 824.2 MHz; σ = 0.911 mho/m; εr = 41.2; ρ = 1000 kg/m3
Phantom section: Left Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 1; Type: SAM 1; Serial: 1185
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

Touch - L-ch/Area Scan (6x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.870 mW/g

Touch - L-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 24.8 V/m; Power Drift = -0.023 dB
Peak SAR (extrapolated) = 1.05 W/kg
SAR(1 g) = 0.806 mW/g; SAR(10 g) = 0.569 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.915 mW/g


                                                     Date/Time: 7/14/2005 10:49:23 AMDate/Time: 7/14/2005 10:55:36 AM

Test Laboratory: Compliance Certification Services

Left Hand Side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.924 mho/m; εr = 41.1; ρ = 1000 kg/m3
Phantom section: Left Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 1; Type: SAM 1; Serial: 1185
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

Touch - M-ch/Area Scan (6x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.965 mW/g

Touch - M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 26.1 V/m; Power Drift = -0.089 dB
Peak SAR (extrapolated) = 1.17 W/kg
SAR(1 g) = 0.893 mW/g; SAR(10 g) = 0.628 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 1.02 mW/g


                                                     Date/Time: 7/14/2005 11:22:14 AMDate/Time: 7/14/2005 11:28:52 AM

Test Laboratory: Compliance Certification Services

Left Hand Side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 848.8 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 848.8 MHz; σ = 0.934 mho/m; εr = 40.9; ρ = 1000 kg/m3
Phantom section: Left Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 1; Type: SAM 1; Serial: 1185
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

Touch - H-ch/Area Scan (6x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.984 mW/g

Touch - H-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 25.6 V/m; Power Drift = -0.032 dB
Peak SAR (extrapolated) = 1.18 W/kg
SAR(1 g) = 0.909 mW/g; SAR(10 g) = 0.643 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 1.03 mW/g


                                                                     Date/Time: 7/14/2005 11:35:38 AM

Test Laboratory: Compliance Certification Services

Left Hand Side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 848.8 MHz;Duty Cycle: 1:8

Touch - H-ch/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.808 mW/g


                                                     Date/Time: 7/14/2005 12:03:58 PMDate/Time: 7/14/2005 12:10:17 PM

Test Laboratory: Compliance Certification Services

Left Hand Side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.924 mho/m; εr = 41.1; ρ = 1000 kg/m3
Phantom section: Left Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 1; Type: SAM 1; Serial: 1185
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

Tilt - M-ch/Area Scan (6x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.482 mW/g

Tilt - M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 22.9 V/m; Power Drift = -0.015 dB
Peak SAR (extrapolated) = 0.586 W/kg
SAR(1 g) = 0.451 mW/g; SAR(10 g) = 0.314 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.517 mW/g


                                                       Date/Time: 7/14/2005 1:15:39 PMDate/Time: 7/14/2005 1:22:05 PM

Test Laboratory: Compliance Certification Services

Right Hand Side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 824.2 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 824.2 MHz; σ = 0.911 mho/m; εr = 41.2; ρ = 1000 kg/m3
Phantom section: Right Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 1; Type: SAM 1; Serial: 1185
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

Touch - L-ch/Area Scan (6x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.947 mW/g

Touch - L-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 24.2 V/m; Power Drift = -0.022 dB
Peak SAR (extrapolated) = 1.14 W/kg
SAR(1 g) = 0.857 mW/g; SAR(10 g) = 0.600 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.984 mW/g


                                                     Date/Time: 7/14/2005 12:28:47 PMDate/Time: 7/14/2005 12:35:12 PM

Test Laboratory: Compliance Certification Services

Right Hand Side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.924 mho/m; εr = 41.1; ρ = 1000 kg/m3
Phantom section: Right Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 1; Type: SAM 1; Serial: 1185
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

Touch - M-ch/Area Scan (6x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.985 mW/g

Touch - M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 24.9 V/m; Power Drift = -0.137 dB
Peak SAR (extrapolated) = 1.17 W/kg
SAR(1 g) = 0.884 mW/g; SAR(10 g) = 0.625 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 1.00 mW/g


                                                       Date/Time: 7/14/2005 1:30:45 PMDate/Time: 7/14/2005 1:37:16 PM

Test Laboratory: Compliance Certification Services

Right Hand Side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 848.8 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 848.8 MHz; σ = 0.934 mho/m; εr = 40.9; ρ = 1000 kg/m3
Phantom section: Right Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 1; Type: SAM 1; Serial: 1185
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

Touch - H-ch/Area Scan (6x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 1.02 mW/g

Touch - H-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 24.9 V/m; Power Drift = -0.035 dB
Peak SAR (extrapolated) = 1.21 W/kg
SAR(1 g) = 0.933 mW/g; SAR(10 g) = 0.656 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 1.07 mW/g


                                                                     Date/Time: 7/14/2005 1:43:47 PM

Test Laboratory: Compliance Certification Services

Right Hand Side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 848.8 MHz;Duty Cycle: 1:8

Touch - H-ch/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.827 mW/g


                   Date/Time: 7/14/2005 12:43:33 PMDate/Time: 7/14/2005 12:50:03 PMDate/Time: 7/14/2005 12:56:07 PM

Test Laboratory: Compliance Certification Services

Right Hand Side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.924 mho/m; εr = 41.1; ρ = 1000 kg/m3
Phantom section: Right Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.75, 9.75, 9.75); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 1; Type: SAM 1; Serial: 1185
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

Tilt - M-ch/Area Scan (6x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.563 mW/g

Tilt - M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 22.3 V/m; Power Drift = -0.003 dB
Peak SAR (extrapolated) = 0.639 W/kg
SAR(1 g) = 0.488 mW/g; SAR(10 g) = 0.347 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.561 mW/g

Tilt - M-ch/Zoom Scan (5x5x7)/Cube 1: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 22.3 V/m; Power Drift = -0.003 dB
Peak SAR (extrapolated) = 0.691 W/kg
SAR(1 g) = 0.462 mW/g; SAR(10 g) = 0.314 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.546 mW/g


                                                       Date/Time: 7/14/2005 2:06:36 PMDate/Time: 7/14/2005 2:13:46 PM

Test Laboratory: Compliance Certification Services

Body worn Front side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 836.6 MHz; σ = 1 mho/m; εr = 56.2; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.72, 9.72, 9.72); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 2; Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

GSM M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.502 mW/g

GSM M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 21.8 V/m; Power Drift = -0.170 dB
Peak SAR (extrapolated) = 0.632 W/kg
SAR(1 g) = 0.458 mW/g; SAR(10 g) = 0.329 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.534 mW/g


                                                       Date/Time: 7/14/2005 5:34:49 PMDate/Time: 7/14/2005 5:41:56 PM

Test Laboratory: Compliance Certification Services

Body worn Front side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 824.2 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 824.2 MHz; σ = 0.99 mho/m; εr = 56.4; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.72, 9.72, 9.72); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 2; Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

GPRS L-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.920 mW/g

GPRS L-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 29.1 V/m; Power Drift = -0.187 dB
Peak SAR (extrapolated) = 1.14 W/kg
SAR(1 g) = 0.829 mW/g; SAR(10 g) = 0.595 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.967 mW/g


                                                       Date/Time: 7/14/2005 2:24:38 PMDate/Time: 7/14/2005 2:31:45 PM

Test Laboratory: Compliance Certification Services

Body worn Front side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 836.6 MHz; σ = 1 mho/m; εr = 56.2; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.72, 9.72, 9.72); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 2; Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

GPRS M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.921 mW/g

GPRS M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 29.6 V/m; Power Drift = -0.225 dB
Peak SAR (extrapolated) = 1.15 W/kg
SAR(1 g) = 0.833 mW/g; SAR(10 g) = 0.600 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.971 mW/g


                                                                     Date/Time: 7/14/2005 2:37:52 PM

Test Laboratory: Compliance Certification Services

Body worn Front side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4

GPRS M-ch/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.701 mW/g


                                                       Date/Time: 7/14/2005 5:52:38 PMDate/Time: 7/14/2005 5:59:48 PM

Test Laboratory: Compliance Certification Services

Body worn Front side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 848.8 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 848.8 MHz; σ = 1.01 mho/m; εr = 56.1; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.72, 9.72, 9.72); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 2; Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

GPRS H-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.790 mW/g

GPRS H-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 27.3 V/m; Power Drift = -0.087 dB
Peak SAR (extrapolated) = 1.05 W/kg
SAR(1 g) = 0.756 mW/g; SAR(10 g) = 0.540 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.887 mW/g


                                                       Date/Time: 7/14/2005 2:44:03 PMDate/Time: 7/14/2005 2:51:10 PM

Test Laboratory: Compliance Certification Services

Body worn Front side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 836.6 MHz; σ = 1 mho/m; εr = 56.2; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.72, 9.72, 9.72); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 2; Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

EGPRS M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.258 mW/g

EGPRS M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 15.4 V/m; Power Drift = -0.033 dB
Peak SAR (extrapolated) = 0.328 W/kg
SAR(1 g) = 0.237 mW/g; SAR(10 g) = 0.170 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.276 mW/g


                                                       Date/Time: 7/14/2005 5:10:33 PMDate/Time: 7/14/2005 5:17:44 PM

Test Laboratory: Compliance Certification Services

Body worn Back side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 836.6 MHz; σ = 1 mho/m; εr = 56.2; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.72, 9.72, 9.72); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 2; Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

GSM M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.722 mW/g

GSM M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 26.2 V/m; Power Drift = -0.018 dB
Peak SAR (extrapolated) = 0.925 W/kg
SAR(1 g) = 0.672 mW/g; SAR(10 g) = 0.482 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.785 mW/g


                                                       Date/Time: 7/14/2005 4:24:25 PMDate/Time: 7/14/2005 4:31:31 PM

Test Laboratory: Compliance Certification Services

Body worn Back side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 824.2 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 824.2 MHz; σ = 0.99 mho/m; εr = 56.4; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.72, 9.72, 9.72); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 2; Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

GPRS L-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 1.59 mW/g

GPRS L-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 38.5 V/m; Power Drift = -0.175 dB
Peak SAR (extrapolated) = 1.99 W/kg
SAR(1 g) = 1.440 mW/g; SAR(10 g) = 1.03 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 1.70 mW/g


                                                                     Date/Time: 7/14/2005 4:37:44 PM

Test Laboratory: Compliance Certification Services

Body worn Back side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 824.2 MHz;Duty Cycle: 1:4

GPRS L-ch/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 1.22 mW/g


                                                       Date/Time: 7/14/2005 4:04:42 PMDate/Time: 7/14/2005 4:11:49 PM

Test Laboratory: Compliance Certification Services

Body worn Back side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 836.6 MHz; σ = 1 mho/m; εr = 56.2; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.72, 9.72, 9.72); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 2; Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

GPRS M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 1.58 mW/g

GPRS M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 37.6 V/m; Power Drift = -0.036 dB
Peak SAR (extrapolated) = 1.95 W/kg
SAR(1 g) = 1.430 mW/g; SAR(10 g) = 1.02 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 1.68 mW/g


                                                       Date/Time: 7/14/2005 3:48:47 PMDate/Time: 7/14/2005 3:55:51 PM

Test Laboratory: Compliance Certification Services

Body worn Back side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 848.8 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 848.8 MHz; σ = 1.01 mho/m; εr = 56.1; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.72, 9.72, 9.72); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 2; Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146

GPRS H-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 1.40 mW/g

GPRS H-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 35.0 V/m; Power Drift = -0.018 dB
Peak SAR (extrapolated) = 1.75 W/kg
SAR(1 g) = 1.270 mW/g; SAR(10 g) = 0.898 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 1.49 mW/g


                                                       Date/Time: 7/14/2005 4:42:24 PMDate/Time: 7/14/2005 4:49:32 PM

Test Laboratory: Compliance Certification Services

Body worn Back side
DUT: High Tech Computer Corp; Type: ST22B; Serial: N/A

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 836.6 MHz; σ = 1 mho/m; εr = 56.2; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24 deg. C; Liquid Temperature: 23 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3552 ; ConvF(9.72, 9.72, 9.72); Calibrated: 3/19/2005
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn500; Calibrated: 2/7/2005
- Phantom: SAM 2; Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.5 Build 19; Postprocessing SW: SEMCAD, V1.8 Build 146



EGPRS M-ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.407 mW/g

EGPRS M-ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 19.2 V/m; Power Drift = -0.020 dB
Peak SAR (extrapolated) = 0.520 W/kg
SAR(1 g) = 0.375 mW/g; SAR(10 g) = 0.267 mW/g
Info: Interpolated medium parameters used for SAR evaluation!
Maximum value of SAR (measured) = 0.441 mW/g



Document Created: 2005-07-14 19:22:07
Document Modified: 2005-07-14 19:22:07

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC