HAC H Field Probe Cal Cert

FCC ID: NM8PC36100

Test Report

Download: PDF
FCCID_1278207

     .       &                                                         $ 9+
Calibration Laboratory of                                          \\\“\\\_//1"/,,                                 Schweizerischer Kalibrierdienst
     .                                                            SXA
Schmid & Partner                                                  M                                                Service suisse d‘étalonnage
   Engineering AG                                                 g///_?\?                                         Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                       ‘»,///?\ &                                      Swiss Calibration Service
                                                                     Ti ube®

Accredited by the Swiss Accreditation Service (SAS)                                              Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreementfor the recognition of calibration certificates

Client       Auden                                                                               Certificate No: H3—6187_Jun09

CALIBRATION CERTIFICATE
 Object                                H3DVE — SN:6187


 Calibration procedure(s)              QA CAL:03.v5
                                       Calibration procedure for H—field probes optimized for close—near field
                                       evaluations in air


 Calibration date:                     June 24, 2009

 Condition of the calibrated item      In Tolerance


 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                      ID #                      Cal Date (Certificate No.)                           Scheduled Calibration
 Power meter E4419B                     GB41293874                1—Apr—09 (No. 217—01030)                             Apr—10
 Power sensor E4412A                    MY41495277                1—Apr—09 (No. 217—01030)                             Apr—10                        [
 Power sensor E4412A                    MY41498087                1—Apr—09 (No. 217—01030)                             Apr—10
 Reference 3 dB Attenuator              SN: $5054 (3c)            31—Mar—09 (No. 217—01026)                            Mar—10
 Reference 20 dB Attenuator             SN: $5086 (20b)           31—Mar—09 (No. 217—01028)                            Mar—10
 Reference 30 dB Aftenuator             SN: $5129 (30b)           31—Mar—09 (No. 217—01027)                            Mar—10
 Reference Probe H3DV&                  SN: 6182                  1—Oct—08 (No. H3—6182_O0ct08)                        Oct—09
 DAE4                                   SN: 789                   19—Dec—08 (No. DAE4—789_Dec08)                       Dec—08                        i

 Secondary Standards                    ID #                      Check Date (in house)                                Scheduled Check
 RF generator HP 8648C                  US3642U01700              4—Aug—99 (in house check Oct—07)                     In house check: Oct—09
 Network Analyzer HP 8753E              US37390585                18—Oct—01 (in house check Oct—08)                    in house check: Oct—09        i


                                        Name                                   Function                                 Signature                    l
 Calibrated by:                        Marcel Fehr                             Laboratory Technician       .           /W


 Approved by:                          Katja Pokovie                           Technical Manager                   /%                 4‘


                                                                                                                       Issued: June 24, 2009
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.



Certificate No: H3—6187_JunQ9                                         Page 1 of 9


    &    &                                                      w0 e
Callb':atlon Laboratory of                                   :‘\“\\\g’l’h}          Schweizerischer Kalibrierdienst
Schmid & Partner                                            m                       Service suisse d‘étalonnage
  Engineering AG                                            $ _"4                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                  "/,I/fi\“v‘            Swiss Calibration Service
                                                                 Whid®

Accredited by the Swiss Accreditation Service (SAS)                              Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates



Glossary:
NORMx,y,z                   sensitivity in free space
DCP                         diode compression point
Polarization                p rotation around probe axis
Polarization $              8 rotation around an axis that is in the plane normal to probe axis (at
                            measurement center), i.e., 8 = 0 is normal to probe axis
Connector Angle              information used in DASY system to align probe sensor X to the robot
                             coordinate system

Calibration is Performed According to the Following Standards:
   a) IEEE Std 1309—2005, " IEEE Standard for calibration of electromagnetic field sensors and
      probes, excluding antennas, from 9 kHz to 40 GHz", December 2005.

Methods Applied and Interpretation of Parameters:
   eX Y,Z2_a0ata2: Assessed for E—field polarization 8 = 90 for XY sensors and 8 = 0 for Z
         sensor (f < 900 MHz in TEM—cell; f > 1800 MHz: R22 waveguide).
    *    X,Y,2(f)_a0ata?= X,Y,Z2_aOa1a2?* frequency_response (see Frequency Response Chart).
    +    DCPx,y,z: DCP are numerical linearization parameters assessed based on the data of
         power sweep (no uncertainty required). DCP does not depend on frequency.
    e    Spherical isotropy (3D deviation from isotropy): in a locally homogeneous field realized
         using an open waveguide setup.
    e    Sensor Offset: The sensor offset corresponds to the offset of virtual measurement center
         from the probe tip (on probe axis). No tolerance required.
    «_   Connector Angle: The angle is assessed using the information gained by determining the
         X_aOa1a2? (no uncertainty required).




Certificate No: H3—6187_Jun09                                   Page 2 of 9


  H3DV6 SN:6187                                                                June 24, 2009




                            Probe H3DVC6

                                        SN:6187
                           Manufactured:                      June 8, 2004
                           Last calibrated:                   May 19, 2008
                           Recalibrated:                      June 24, 2009

                                  Calibrated for DASY Systems
                                   (Note: non—compatible with DASY2 system!)




Certificate No: H3—6187_JunQ9               Page 3 of 9


  H3DV6 SN:6187                                                                                 June 24, 2009


  DASY — Parameters of Probe: H3DV6 SN:6187
  Sensitivity in Free Space [A/m / v(uV)]
                               a0               al                a2
               X                3.336E—03            —8.041E—5         3.177E—5 £5.1 % (k=2)
               Y¥               2.531E—03             9.397E—6         1.979E—5 £ 5.1 % (k=2)
               Z                3.120E—03            —1.434E—4         8.995E—5 £ 5.1 % (k=2)

  Diode Compression‘

  DCP X                   98 mV
  DCP Y                   95 mV
  DCP Z                   84 mV

  Sensor Offset                                 (Probe Tip to Sensor Center)

               X                                             3.0 mm
               Y                                             3.0 mm
               Z                                             3.0 mm

  Connector Angle                                          116 °




   The reported uncertainty of measurement is stated as the standard uncertainty of
   measurement multiplied by the coverage factor k=2, which for a normal distribution
   corresponds to a coverage probability of approximately 95%.



 * numerical linearization parameter: uncertainty not required




Certificate No: H3—6187_JunO9                                Page 4 of 9


  H3DV6 SN:6187                                                                                                          June 24, 2009



                                                             Frequency Response of H—Field
                                                                  (TEM—Cell:ifi110 EXX, Waveguide R22)
                  Frequency response (normalized)




                                                                                                                    %
                                                    &




                                                    0.9

              j                                     o.8

              [                                     0.7

                                                    0.6 ‘         —                     —       e                 <oa
              .                                         o        500      1000        1500    2000       2500      3000
                                                                                  f [MHz]
              ‘                                                  i——sy:          —#@—TEM      —#—R22                        ,
                                                                 _ ——z           _ —@—TEM     —#—R22     ;



                                                            Uncertainty of Frequency Response of E—field: £ 6.3% (k=2)




Certificate No: H3—6187_Jund9                                                 Page 5 of 9


  H3DV6 SN:6187                                                              June 24, 2009




                                Receiving Pattern (¢), 8 = 90°

               f= 600 MHz, TEM ifi110EXX                    f = 2500 MHz, WG R22




          1 —@—X      —@—Y¥     —@—Z   -—O—tot‘




                                 Receiving Pattern (¢), 9 = 0°

              f= 600 MHz, TEM ifi110EXX                     f = 2500 MHz, WG R22




                                                                      —@—Z    —O—tot




Certificate No: H3—6187_Jun09                 Page 6 of 9


 H3DV6 SN:6187                                                                              June 24, 2009




                                   Receiving Pattern (¢), 8 = 90°

          1.0
          0.8
          0.6                                                                          —6—300 MHz
    a g;                                                                               —m—600 MHz
    ‘.% 0.0                                                                            —&—750 MHz
                                                                                       —m— 1800 MHz
    BE .02                                                                             —&— 2500 MHz
    " 0.4
       —0.6
       —0.8
       —1.0
                1        7             13        19              25      31
                                                $l



                                  Uncertainty of Axial Isotropy Assessment: + 0.5% (k=2)




                                    Receiving Pattern (¢), 9 = 0°



                                                                                           —0—300 MHz
      a                                                                                    —m—600 MHz
                                                                                           —4—750 MHz
      5                                                                                    | —m— 1800 MHz
      &
                                                                                           —&—2500 MHz
           —0.8
           —1.0
                    o        s0        120         180           240     300
                                                4 F1



                                  Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




Certificate No: H3—6187_JunO9                      Page 7 of 9


 H3DV6 SN:6187                                                                                                          June 24, 2009



                                                           Dynamic Range f(H—field)
                                                             (Waveguide R22, f = 1800 MHz)


                                      1.E+06



                                      1.E+05



                                      1.E+04
                Sensor Voltage [uV)




                                      1.E+03




                                      1.E+02 ;



                                      1.E+01




                                      1.E+00           —               —               —                ——
                                           0.001                     0.01                         0.1                   1
                                                                            H [A/m] at 1800 MHz

                                                   —@—XY             m   XY corr           —&—Z              ——Z corr
              Error [dB]




                                      a|
                                      0.001                    0.0
                                                                     1 H [A/m] at 1800 MHz 01                               1




                                                      Uncertainty of Linearity Assessment: £ 0.6% (k=2)




Certificate No: H3—6187_Jun09                                            Page 8 of 9


  H3DV6 SN:6187                                                                                                   June 24, 2009



                                      Deviation from Isotropy in Air
                                            Error (¢, 9) , f= 900 MHz




                                                                                                     Error [dB]




                      —                                         0.                     —
                      MI—1.00——0.80   , M—0.80——0.60    M—0.60——0.40   l —0.40——0.20   W—0.20—0.00
                      0.00—0.20        M0.20—0.40       ©0.40—0.60     ©10.60—0.80     0.80—1.00




                                Uncertainty of Spherical Isotropy Assessment: £ 2.6% (k=2)




Certificate No: H3—6187_JunO9                          Page 9 of 9



Document Created: 2010-05-03 19:10:58
Document Modified: 2010-05-03 19:10:58

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC