RFExpPower Density_Appendix C

FCC ID: NM82Q6U100

RF Exposure Info

Download: PDF
FCCID_4205396







DASY Report

Measurement Report for 5G Verification Source 60 GHz, UID 0 -, Channel 60000 (60000.0MHz)

Device under Test Properties
Name, Manufacturer                  Dimensions [mm]                     IMEI                             DUT Type
5G Verification Source 60 GHz       100.0 x 100.0 x 100.0               SN: 1009                         -

Exposure Conditions
Phantom Section             Position, Test Distance   Band                 Group,                     Frequency [MHz],          Conversion Factor
                            [mm]                                                                      Channel Number
5G -                        5.55 mm                   Validation band      CW                         60000.0,                  1.0
                                                                                                      60000


Hardware Setup
Phantom                               Medium                                    Probe, Calibration Date                  DAE, Calibration Date
5G Phantom                            Air                                       EUmmWV2 - SN9374, 2018-03-23             DAE4 Sn1215, 2018-02-26


Scan Setup                                                                      Measurement Results
                                                                  5G Scan                                                                      5G Scan
 Grid Extents [mm]                                             25.0 x 25.0         Date                                               2018-04-05, 17:34
 Grid Steps [lambda]                                           0.25 x 0.25         Avg. Area [cm2]                                                 1.00
 Sensor Surface [mm]                                                  5.55         pStot avg [W/m2]                                                 344
 MAIA                                                        MAIA not used         pSn avg [W/m2]                                                   343
                                                                                   Epeak [V/m]                                                      411
                                                                                   Power Drift [dB]                                               -0.02




Certificate No: 5G-Veri60-1009_Apr18/2                       Page 4 of 4












Calibration Laboratory of
Schmid & Partner
                                                                                                           s
                                                                                                           C
                                                                                                                   Schweizerischer Kalibrierdienst
                                                                                                                   Service suisse d'etalonnage
 Engineering AG                                                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                               S       Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                                            Accreditation No.:      SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recogn ition of calibration certificates

Client      Sporton                                                                            Certificate No:      DAE4-778_May18

CALIBRATION CERTIFICATE
 Object                               DAE4 - SD 000 D04 BM - SN: 778


 Calibration procedure(s)             QA CAL-06.v29
                                      Calibration procedure for the data acquisition electronics (DAE)



 Calibration date:                    May 25, 2018




 This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (SI).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 ± 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                                                Cal Date (Certificate No.)                            Scheduled Calibration
 Keithley Multimeter Type 2001        I SN: 0810278               31-Aug-17 (No:21092)                                  Aug-18


 Secondary Standards                    ID #                      Check Date (in house)                                 Scheduled Check
 Auto DAE Calibration Unit              SE UWS 053 AA 1001        04-Jan-18 (in house check)                            In house check: Jan-19
 Calibrator Box V2.1                    SE UMS 006 AA 1002        04-Jan-18 (in house check)                            In house check: Jan-19




                                        Name                                   Function                                  Signature
 Calibrated by:                         Dominique Steffen                      Laboratory Technician
                                                                                                                       ~ 2 -.
 Approved by:                           Sven Kuhn                              Deputy Manager
                                                                                                                           \ ,I ,    ~ l)}JLif
                                                                                                                                          1
                                                                                                                         Issued: May 25, 2018
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




Certificate No: DAE4-778_May18                                        Page 1 of 5


Calibration Laboratory of                                                      S   Schweizerischer Kalibrierdienst
Schmid & Partner                                                                   Service suisse d'etalonnage
                                                                               C
 Engineering AG                                                                    Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                   s   Swiss Calibration Service


Accredited by the Swiss Accreditation SeNice (SAS)                             Accreditation No.:   SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for t he recognition of calibration certificates



Glossary
DAE                          data acquisition electronics
Connector angle              information used in DASY system to align probe sensor X to the robot
                             coordinate system.

Methods Applied and Interpretation of Parameters
  •   DC Voltage Measurement: Calibration Factor assessed for use in DASY system by
     comparison with a calibrated instrument traceable to national standards. The figure given
     corresponds to the full scale range of the voltmeter in the respective range.
    •    Connector angle: The angle of the connector is assessed measuring the angle
         mechanically by a tool inserted. Uncertainty is not required .
    •    The following parameters as documented in the Appendix contain technical information as a
         result from the performance test and require no uncertainty.
         •     DC Voltage Measurement Linearity: Verification of the Linearity at + 10% and -10% of
               the nominal calibration voltage. Influence of offset voltage is included in this
               measurement.
         •     Common mode sensitivity: Influence of a positive or negative common mode voltage on
               the differential measurement.
         •     Channel separation: Influence of a voltage on the neighbor channels not subject to an
               input voltage.
         •     AD Converter Values with inputs shorted: Values on the internal AD converter
               corresponding to zero input voltage
         •     Input Offset Measurement Output voltage and statistical results over a large number of
               zero voltage measurements.
         •     Input Offset Current: Typical value for information; Maximum channel input offset
               current, not considering the input resistance.
         •     Input resistance: Typical value for information: DAE input resistance at the connector,
               during internal auto-zeroing and during measurement.
         •     Low Battery Alarm Voltage: Typical value for information . Below this voltage, a battery
               alarm signal is generated.
         •     Power consumption: Typical value for information. Supply currents in various operating
               modes.




Certificate No: DAE4-778_May18                                   Page 2 of 5


DC Voltage Measurement
   AID - Converter Resolution nominal
       High Range:          1LSB;     6.1µV,         full range; -100 ... +300 mV
       LowRange:            1LS8;      61nV,         fullrange; -1 .......+3mV
   DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec

     Calibration Factors            X                        y                      z
     High Range            404.721 ± 0.02% (k;2)   403.519 ± 0.02% (k;2)   405.076 ± 0.02% (k;2)

     Low Range             3.98715 ± 1.50% (k;2)   3.96471 ± 1.50% (k;2)   4.00070 ± 1.50% (k;2)



Connector Angle

     Connector Angle to be used in DASY system                                  269.0   °±1 °




Certificate No: DAE4-778_May18                     Page 3 of 5


Appendix (Additional assessments outside the scope of SCS0108)

1. DC Voltaae Linearitv
      High Range                               Reading (µV)          Difference (µ V)              Error(%)
      ChannelX        + Input                   199995.64                    0.22                   0.00
     ChannelX         + Input                   20002.64                     0.86                   0.00
     ChannelX         - Input                   -19997.90                    3.08                  -0.02
     Channel Y        + Input                   199995.52                    0.45                   0.00
     Channel Y        + Input                   20001.45                    -0.24                  -0.00
     ChannelY         - Input                   -19999.33                    1.69                  -0.01
     Channel Z        + Input                   199995.39                    0.09                   0.00
     Channel Z        + Input                    19999.28                   -2.37                  -0.01
     Channel Z        - Input                   -20004.97                   -3.83                   0.02


     Low Range                                 Reading (µV)          Difference (µV)               Error(%)
     Channel X        + Input                    2001.37                     0.09                   0.00
     Channel X        + Input                    201.71                      0.03                   0.02
     ChannelX        - Input                     -198.71                    -0.55                   0.28
     Channel Y       + Input                     2002.06                     0.78                   0.04
     ChannelY        + Input                     201.56                     -0.13                  -0.07
     Channel Y       - Input                     -198.85                    -0.61                   0.31
     ChannelZ        + Input                     2001.83                    0.60                    0.03
     ChannelZ        + Input                     200.63                     -1.14                  -0.57

     ChannelZ        - Input                     -199.30                    -0.95                   0.48



2. Common mode sensitivity
    DASY measurement parameters: Auto Zero Time: 3 sec; Measurina time: 3 sec
                        Common mode                       High Range                            Low Range
                        Input Voltage (mV)            Average Reading (µV)                 Average Reading (µV)

    Channel X                           200                      -4.34                           -5.51
                                       - 200                      6.01                           4.80
    Channel Y                           200                       0.02                           -1.10
                                       - 200                      0.55                           0.11
    ChannelZ                            200                      -13.81                         -14.40
                                       -200                      12.18                          11.59



3. Channel separation
    DASY measurement parameters: Auto Zero Time: 3 sec; Measurinn time: 3 sec
                       Input Voltage (mV)         Channel X (µV)          Channel Y (µV)       Channel Z (µV)
    ChannelX                     200                       -                  -0.84                 -2.53
    ChannelY                     200                   8.46                     -                   0.02
    ChannelZ                     200                   4.29                    6.73                      -

Certificate No: DAE4-778_May18                              Page 4 of 5


4. AD-Converter Values with inputs shorted
    DASY measurement parameters: Auto Zero Time: 3 sec; Measurino time: 3 sec

                                                    High Range (LSB)                        Low Range (LSB)

     ChannelX                                               16056                                16906

     Channel Y                                              16191                                17602

     Channel Z                                              16433                                15344



5. Input Offset Measurement
    DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 sec
    lnout 10MQ
                                                                                                 Std. Deviation
                            Average (µVJ        min. Offset (µVJ         max. Offset (µVJ
                                                                                                      (11Vl
     ChannelX                    -0.05                -1.10                       1.05                  0.43
     ChannelY                    0.23                 -1.15                       1.67                  0.53
     Channel Z                   -0.76                -1.76                       0.94                  0.52



6. Input Offset Current
     Nominal Input circuitry offset current on all channels: <25fA


7. In out Resistance        /Tvpical values for information)
                                                  Zeroing (kOhm)                           Measuring (MOhm)
     ChannelX                                              200                                   200
     Channel Y                                             200                                   200
     Channel Z                                             200                                   200



8. Low Batterv Alarm Voltaae              (Tvpical values for information\
    Typical values                                Alarm Level (VDC)
     Supply(+ Vee)                                                                 +7.9
     Supply (- Vee)                                                                 -7.6



9. Power Consumotion             (Typical values for information)
    Typical values                          Switched off (mA)        Stand by (mA)            Transmitting (mA)
    Supply(+ Vee)                                  +0.01                    +6                         +14
    Supply (- Vee)                                 -0.01                     -8                        -9




Certificate No: DAE4-778_May18                             Page 5 of 5



Document Created: 2019-05-13 21:25:53
Document Modified: 2019-05-13 21:25:53

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC