User Manual m14q2fg

FCC ID: NKRM18Q2

Users Manual

Download: PDF
FCCID_3170089

  User manual



                            Project Name: M14Q2FG

                            Author: Wistron NeWeb Corporation

                            Revision: 1.0

                            Revision Date: 2016/06/23



□ Normal   □ Internal Use    Confidential   □ Restricted Confidential   1 / 33


                                                                             User Manual




 Contact Information
  Sale and Technical Support          SupportIoT.MBA@wnc.com.tw

  Website                             www.wnc.com.tw




 Revision History
   Rev. #         Author              Summary of Changes                  Date
   1.0            WNC MBU             Draft release                       2016/6/23




□ Normal    □ Internal Use    Confidential   □ Restricted Confidential           2 / 33


                                                                                                               User Manual




 © Wistron NeWeb Corporation

 THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN IS PROPRIETARY AND IS THE EXCLUSIVE
 PROPERTY OF WNC AND SHALL NOT BE DISTRIBUTED, REPRODUCED, OR DISCLOSED IN WHOLE OR IN
 PART WITHOUT PRIOR WRITTEN PERMISSION FROM WNC.



 LIMITATION OF LIABILITY

 THIS DOCUMENT AND THE INFORMATION CONTAINED HEREIN IS PURELY FOR DESIGN REFERENCE AND
 SUBJECT TO REVISION BY WNC AT ANY TIME. NOTHING IN THIS DOCUMENT SHALL BE CONSTRUED AS
 GRANTING ANY WARRANTY OR RIGHT TO USE THE MATERIAL CONTAINED HEREIN WITHOUT WNC’S
 PRIOR EXPRESS WRITTEN CONSENT. WNC SHALL NOT BE LIABLE FOR ANY USE, APPLICATION OR
 DEVELOPMENT DERIVED FROM THE MATERIAL WITHOUT SUCH PRIOR EXPRESS WRITTEN CONSENT.


 FCC Regulations:

 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device
 may not cause harmful interference, and (2) This device must accept any interference received, including interference
 that may cause undesired operation.

 This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
 FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
 installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in
 accordance with the instructions, may cause harmful interference to radio communications. However, there is no
 guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference
 to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
 to try to correct the interference by one or more of the following measures:

 -Reorient or relocate the receiving antenna.

 -Increase the separation between the equipment and receiver.

 -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

 -Consult the dealer or an experienced radio/TV technician for help.




 Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s
 authority to operate the equipment.




□ Normal   □ Internal Use    Confidential      □ Restricted Confidential                                              3 / 33


                                                                                                                User Manual




 RF Exposure Information

 This device is intended only for OEM integrators under the following conditions:
 (1) The antenna must be installed such that 20 cm is maintained between the antenna and users,
 (2) The transmitter module may not be co-located with any other transmitter or antenna.
 (3) To comply with FCC regulations limiting both maximum RF output power and human exposure to RF radiation, the
 maximum antenna gain including cable loss in a mobile exposure condition must not exceed:


 Standalone Condition:
 。 8.0 dBi in 700 MHz Band
 。8.0 dBi in 850 MHz Band
 。5.0 dBi in 1700 MHz Band
 。7.5 dBi in 1900 MHz Band


 Assuming collocated with a WLAN transmitter with maximum 27 dBm average EIRP power
  。 7.0 dBi in 700 MHz Band
  。5.0 dBi in 850 MHz Band
  。5.0 dBi in 1700 MHz Band
  。7.5 dBi in 1900 MHz Band

 Remark: This assumption is not valid if the output power of the collocated WLAN transmitter is higher than 27 dBm.


 IMPORTANT NOTE:

 This module is intended for OEM integrator. The OEM integrator is still responsible for the FCC compliance requirement
 of the end product, which integrates this module. 20cm minimum distance has to be able to be maintained between
 the antenna and the users for the host this module is integrated into. Under such configuration, the FCC radiation
 exposure limits set forth for an population/uncontrolled environment can be satisfied.

 Any changes or modifications not expressly approved by the manufacturer could void the user's authority to operate
 this equipment.


 USERS MANUAL OF THE END PRODUCT:

 In the users manual of the end product, the end user has to be informed to keep at least 20cm separation with the
 antenna while this end product is installed and operated. The end user has to be informed that the FCC radio-frequency
 exposure guidelines for an uncontrolled environment can be satisfied. The end user has to also be informed that any
 changes or modifications not expressly approved by the manufacturer could void the user's authority to operate this
 equipment. If the size of the end product is smaller than 8x10cm, then additional FCC part 15.19 statement is required



□ Normal   □ Internal Use     Confidential   □ Restricted Confidential                                               4 / 33


                                                                                                               User Manual




 to be available in the users manual: This device complies with Part 15 of FCC rules. Operation is subject to the following
 two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference
 received, including interference that may cause undesired operation.




□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                                                5 / 33


                                                                                                                                           User Manual




 Contents
 Contact Information ......................................................................................................................... 2

 Revision History................................................................................................................................ 2
 Contents ........................................................................................................................................ 6
 1. Introduction........................................................................................................................... 8
     1.1. Features .................................................................................................................................8

 2.     Electrical Specifications...................................................................................................... 9
        2.1. Host interface pin assignments...........................................................................................9

                2.1.1.        LGA Pad Diagram ....................................................................................................9

                2.1.2.        Pin Assignments .....................................................................................................10

         2.2. Power supply .......................................................................................................................12

         2.3. USB interface.......................................................................................................................14

         2.4. SGMII interface ...................................................................................................................15

         2.5. HSIC interface .....................................................................................................................16

         2.6. SIM interface ........................................................................................................................17

         2.7. Control interface (wakeup) ................................................................................................17

         2.8. Digital interface ....................................................................................................................18

                2.8.1.        JTAG Interface ........................................................................................................18

                2.8.2.        SPI Master Interface ..............................................................................................18

                2.8.3.        PCM Interface .........................................................................................................19

                2.8.4.        I2S Interface............................................................................................................19

                2.8.5.        I2C Interface ...........................................................................................................20

                2.8.6.        UART Interface .......................................................................................................20

                2.8.7.        ADC Interface .........................................................................................................21

 3.     RF Specifications ............................................................................................................... 22
        3.1. RF connections ...................................................................................................................22



□ Normal    □ Internal Use         Confidential        □ Restricted Confidential                                                                  6 / 33


                                                                                                                                         User Manual




       3.2. RF Layout guidance ...........................................................................................................22

       3.3. Antenna Guidance ..............................................................................................................24

       3.4. Interference and sensitivity ................................................................................................24

       3.5. Radiated sensitivity measurement ...................................................................................25

       3.6. GNSS external circuit design ............................................................................................25

       3.7. Supported frequencies .......................................................................................................25

 4.    Software Interface .............................................................................................................. 27
       4.1. Support tools ........................................................................................................................27

       4.2. USB interface.......................................................................................................................27

 5.    Mechanical and Environmental Certifications ............................................................... 28
       5.1. PCBA Form Factor ..............................................................................................................28

       5.2. Labeling ................................................................................................................................31

 6.    Regulatory Compliance and Certification....................................................................... 32
       6.1. Certification testing .............................................................................................................32

 7.    Safety Recommendation ................................................................................................... 33




□ Normal   □ Internal Use        Confidential         □ Restricted Confidential                                                                 7 / 33


WNC

  1. Introduction
 The M14Q2FG is a Cat. 1 LTE modem which incorporates an application CPU subsystem and a host of
 peripheral interfaces and functions uniquely designed to address the power/performance/cost
 requirements of loT and M2M applications. The chip is based on Qualcomm‘s MDM architecture which
 offers OFDMA—related software based signal processing capabilities that significantly exceed traditional
 communications ARM cores.


 The CPU subsystem features a high performance Cortex A7 microprocessor running a Linux OS with a
 variety of host interfaces including USB 2.0, SGMII, SPI, UART, PCM, 12C, HSIC, USIM & SDC. The module
 supports integrated VoITE functionality, with a variety of narrow— and wide—band CODECs and full IMS
 signaling.




  1.1. Features

           3GPP category support: LTE Cat. 1 with (10Mbps downlink, 5Mbps uplink)
           Supports LTE B2/4/5/12
           Supports WCDMA B2/5
           Supports GPS/GLONASS
           Ultra—high—performance Cortex A7 microprocessor
           Modem subsystem (MSS)
           Integrated support for VoLTE
           Resource and power management (RPM) subsystem
           Optimized for M2M and loT markets
           Interfaces
              —HS USB 2.0 with integrated PHY
              —SGMII interface
              —HSIC interface
              — Dual UART interfaces (4 bit and 2 bit) for data transfer and diagnostic tools
              —SDC1: First SPI interface
              —I12C: Second SPI interface
              — USIM interface
              —GPIOs
              —ADC
              —=PCM/I12S
              —JTAG interface




C Normal    O Internal Use   M Confidential   o Restricted Confidential                               8 / 33


                                                                              User Manual




 2. Electrical Specifications

 2.1. Host interface pin assignments
 2.1.1. LGA Pad Diagram




                                       Figure 1. LGA pad diagram (top view)




□ Normal   □ Internal Use    Confidential   □ Restricted Confidential            9 / 33


                                                                                                        User Manual




 2.1.2. Pin Assignments

                                             Table 1. Pin interface family
  Interface Family                           Signal                          Description                    I/O
                                             ANT1_DRX                        Diversity antenna              I
  RF Interfaces                              ANT_GNSS                        Reserved for GNSS receiver     I
                                             ANT0_TRX                        Main Antenna                   I/O
                                             VREG_L6_UIM1                    Power source for UIM           O
                                             UIM1_DATA                       Data in/out                    I/O
  User Identity Module                       UIM1_CLK                        Clock signal                   O
                                             UIM1_RESET                      Reset signal                   O
                                             UIM1_DETECT                     UIM Detect signal              I/O
                                             USB_HS_DP                       USB Data Positive              I/O
                  USB 2.0                    USB Detect                      USB Detect                     I
                                             USB_HS_DM                       USB Data Negative              I/O
                                             HSIC USB_STROBE                 HSIC USB Strobe                I/O
                  HSIC
                                             HSIC USB_DATA                   HSIC USB Data                  I/O
                                             SGMII_RX_P                      SGMII receive - plus           I
                                             SGMII_RX_M                      SGMII receive - minus          I
                                             SGMII_TX_P                      SGMII transmit - plus          O
                  SGMII
                                             SGMII_TX_M                      SGMII transmit - minus         O
                                             SGMII_MDIO                      SGMII Management data          I/O
                                             SGMII_MDC                       SGMII Management data clock I/O
  Data                                       UART1_CTS_N                     Clear To Send for UART 1       I
  Interfaces                                 UART1_RFR_N                     UART ready for frame           O
                  UART1
                                             UART1_RX                        Receive for UART 1             I
                                             UART1_TX                        Transmit for UART 1            O
                                             MDM_DBG_UART_RX                 Receive for UART 2             I
                  UART2
                                             MDM_DBG_UART_TX                 Transmit for UART 2            O
                                             I2C_SDA                         Data in/out                    I/O
                                             2nd_SPI_EN_1                    2nd_SPI chip select            O
                                             I2C_SCL                         Clock signal                   O
                  I2C/2nd_ SPI               2nd_SPI_CLK                     2nd_SPI serial clock           O
                                             NC                              NC
                                             SPI_MOSI                        2nd_SPI master out slave in    O
                                             NC                              NC



□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                                     10 / 33


                                                                                                    User Manual




                                             SPI_MISO                    2nd_SPI master in slave out    I
                                             SDC1_DATA_3                 SDC1_DATA_3                    I/O
                                             1st_SPIM_MOSI               1st_SPI master out slave in    O
                                             SDC1_DATA_2                 SDC1_DATA_2                    I/O
                                             1st_SPIM_MISO               1st_SPI master in slave out    I
                                             SDC1_DATA_1                 SDC1_DATA_1                    I/O
                 SDC1/1st_SPI
                                              1st_SPIM_EN_1              1st_SPI chip select            O
                                             SDC1_DATA_0                 SDC1_DATA_0                    I/O
                                             1st_SPIM_CLK                1st_SPI serial clock           O
                                             SDC1_CMD                    SDC1_CMD                       I/O
                                             SDC1_CLK                    SDC1_CLK                       O
                                             WWAN_STATE                  Wireless WAN Radio State       O
                                             POWER_ON                    Power On the module            I
  Module Control and
                                             WAKEUP_OUT                  Module wakes up host OR GPIO O
  State Interfaces
                                             WAKEUP_IN                   Host wakes up module OR GPIO. I
                                             RESET                       Reset the module               I
                                             VREF                        Voltage Reference Output       O
  Power and Ground                           VCC                         Main Power                     I
                                             GND                         GND                            I
                                             GPIO                        Digital I/O                    I/O
  General Purpose
                                             ADC_CONVENTOR               ADC_CONVENTOR                  I
                                             PCM_DIN                     PCM_DIN                        IO
                                             AUX_BT_I2S_DATA0            AUX_BT_I2S_DATA0               IO
                                             PCM_DOUT                    PCM_DOUT                       IO
                                             AUX_BT_I2S_DATA1            AUX_BT_I2S_DATA1               IO
  AUDIO             PCM/I2S
                                             PCM_CLK                     PCM_CLK                        O
                                             AUX_BT_I2S_SCK              AUX_BT_I2S_SCK                 O
                                             PCM_SYNC                    PCM_SYNC                       O
                                             AUX_BT_I2S_WS               AUX_BT_I2S_WS                  O
  RFU               RFU                      RFU                         Reserved For Future Use        I
                                             MDM_JTAG_SRST_N             JTAG reset for debug           I
                                             MDM_JTAG_TCK                JTAG clock input               I
                                             MDM_JTAG_TDI                JTAG data input                I
  Debug             JTAG
                                             MDM_JTAG_TDO                JTAG data output               O
                                             MDM_JTAG_TMS                JTAG mode select input         I
                                             MDM_JTAG_TRST_N             JTAG reset                     O


□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                                 11 / 33


                                                                                                     User Manual




                                             MDM_PS_HOLD                  PS_HOLD                            I
                    Force_USB_BOOT           Force_USB_BOOT_CONFIG        Force USB BOOT CONFIG              I


                                        Table 2. Digital I/O characteristics




 Note: This is preliminary data for reference and will be updated according to the final version of the
 MDM9207 datasheet.



 2.2. Power supply
 LTE module power input is VCC. The internal power chipset will transfer VCC to other power level.

                                       Table 3. Power supply specifications
                                                                                       Voltage Level (V)
 Power            Pin Name         Pads              Description
                                                                                Min.         Typ.      Max.
 VCC              VCC1 to VCC6 Nos. 37 to 42 Main Power Supply                   3.3         3.8           4.2
 The M14Q2FG includes an integrated power manager enabling single and direct voltage supply from the
 battery, reducing the overall bill of materials.




□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                                     12 / 33


                                                                                                     User Manual




                   VCC (3.3 V to 4.2 V)                                   VREG_S1
                                                   DCDC1.125 V                      1.125 V


                   VCC (3.3 V to 4.2 V)                                   VREG_S2
                                                   DCDC1.275 V                      1.275 V


                   VCC (3.3 V to 4.2 V)                                   VREG_S3
                                                   DCDC1.125 V                      1.125 V


                   VCC (3.3 V to 4.2 V)                                   VREG_S4
                                                    DCDC1.95 V                      1.95 V



                                                                               VREG_L1    1.25 V
                                                                               VREG_L2     1.8 V
                                                                               VREG_L3  1.8 V
                                                                               VREG_L4   3.075 V
                                                                               VREG_L5    2.85 V
                                                                               VREG_L6    2.85 V
                                                                               VREG_L7     1.8 V
                                                                               VREG_L8     1.8 V
                                                                               VREG_L9    1.225 V
                   VCC (3.3 V to 4.2 V)                 LDOS
                                                                              VREG_L10     1.025 V
                                                                               VREG_L11     1.8 V
                                                                              VREG_L12      1.15 V
                                                                               VREG_L13    2.85 V
                                                                              VREG_L14     2.7 V
                                                                             VREG_RFCLK    1.8 V
                                                                               VREG_XO    1.8 V
                                                                              VREG_LPDDR 0.6 V




                                      Figure 2. M14Q2FG internal power path

 Layout Suggestion: Each power trace should possess sufficient line width to withstand its respective
                     current listed in the table below:
                            Net Name                         Current Value
                            VCC(1–6) total                   2A
                            UIM_VCC                          150 mA
                            VREF                             300 mA




□ Normal   □ Internal Use     Confidential   □ Restricted Confidential                                 13 / 33


                                                                                                    User Manual




 2.3. USB interface
 The M14Q2FG module complies with USB 2.0 high-speed protocol. The USB input/output lines follow
 USB 2.0 specifications.

                                       Table 4. Signals of the USB interface
                                             Input/Output                             Voltage Level (V)
   Name            Description
                                             (Direction to module)             Min.         Typ.          Max.
                                             Input High                         2           3.3           3.6
                   USB data positive         Input Low                          0                         0.8
                   (low-/full-speed)         Output High                       2.8          3.3           3.6
                                             Output Low                                                   0.3
   D+
                                             Input High                        0.3                        0.44
                   USB data positive         Input Low                          0                         0.01
                   (high-speed)              Output High                       0.36         0.38          0.44
                                             Output Low                         0                         0.01
                                             Input High                         2           3.3           3.6
                   USB data negative         Input Low                          0                         0.8
                   (low-/full-speed)         Output High                       2.8          3.3           3.6
                                             Output Low                                                   0.3
   D–
                                             Input High                        0.3                        0.44
                   USB data negative         Input Low                          0                         0.01
                   (high-speed)              Output High                       0.36         0.38          0.44
                                             Output Low                         0                         0.01

 The layout design of this circuit on the host board should comply with the USB 2.0 high-speed protocol.

 Layout suggestion:
      Differential impedance: 90 Ω
      Space to other signals should be at least 20 mils
      Intra-lane length difference should be less than 150 mils
      Maximum length for each trace:150 mm


 Signals lengths on M14Q2FG are tuned as below:
  Function     Net                                     Length (mil)
               USB_Dp                                  545.54
  USB
               USB_Dn                                  503.04



□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                                     14 / 33


                                                                                            User Manual




 2.4. SGMII interface
 The M14Q2FG includes integrated Ethernet MAC with SGMII interfaces with the following key features:
      IEEE 802.3 compliance
      Full duplex at 1 Gbps
      Half/full duplex for 10/100 Mbps
      Supports VLAN tagging
       Supports IEEE 1588, Precision Time Protocol (PTP)
       Can be used to connect to external Ethernet PHYs such as AR8033 or to an external switch

 The following figures describe an example of the additional logic connection between the M14Q2FG and
 the Ethernet chip.




                                             Figure 3. SGMII circuit example

 Layout suggestion:
      Differential impedance:100 Ω
      Space to other signals: > 3x line width
      Lane-to-lane space: > 3x line width
      Intra-lane mismatch: < 0.7 mm




□ Normal   □ Internal Use    Confidential    □ Restricted Confidential                            15 / 33


                                                                                             User Manual




 Signals lengths on the M14Q2FG are tuned as below:
  Function     Net                                      Length (mil)
               SGMII_TX_P                               617.11
               SGMII_TX_M                               642.13
  SGMII
               SGMII_RX_P_C+SGMII_RX_P                  661.40
               SGMII_RX_M_C+SGMII_RX_M                  675.06



 2.5. HSIC interface
 The M14Q2FG includes a HSIC interface. This host interface can be connected to other application
 processor or interface-transfer chipset.




                                             Figure 4. HSIC circuit example

 Layout suggestion:
      Single-end impedance: 50 Ω
      Intra-lane mismatch: < 2 mm
      Maximum trace length:100 mm

 Signals lengths on the M14Q2FG are tuned as below:
  Function     Net                                      Length (mil)
               HSIC_STB                                 287.29
  HSIC
               HSIC_DATA                                315.04




□ Normal   □ Internal Use    Confidential    □ Restricted Confidential                             16 / 33


                                                                                                  User Manual




 2.6. SIM interface
 The M14Q2FG includes a SIM controller, interface pins, and a dedicated LDO (3.0 V or 1.8 V).
 The following figures describe the additional logic connection between the M14Q2FG and the SIM card.




                                       Figure 5. SIM card circuit (example)



 2.7. Control interface (wakeup)
 In applications where power consumption is a major factor in performance metrics (such as
 battery-operated sensors that are based on IOT/M2M modem solution and also include a third party
 host), it is necessary to define a simple interface that will allow both the modem and the host to be able
 to enter low power states whenever possible and the other side to wake it up once required.

 For example, if the host has no data to transmit nor any other tasks, it may enter some low power state
 according to its own capabilities and configurations. If during that period the host is in a low power state
 and the modem suddenly receives data, it must wake-up the host.

 A similar requirement exists from the other side. For example, if the modem is in a low power state and
 suddenly the host must transmit data, it must be able to wake-up the modem.

 The interface consists of two signals: One is driven by the host and received by the modem; the other is
 driven by the modem and received by the host.

 Each side can wake the other side by toggling wakeup signal high and allowing the other side to go to



□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                                 17 / 33


                                                                                                   User Manual




 sleep when not needed by toggling it low.

       “WAKEUP_IN” (Host: Output, Modem: Input):
           LOW: SoC does not require the MODEM (allowing it to sleep).
           HIGH: SoC requires the MODEM or acknowledges it is ready following a wakeup request from the
           MODEM.

       “WAKEUP_OUT” (Host: Input, Modem: Output):
           LOW: The MODEM does not require the Host (allowing it to sleep)
           HIGH: The MODEM requires the Host or acknowledges it is ready following a wakeup request
           from the SoC.



 2.8. Digital interface
 This section provides the required AC timing information relating to Module Digital Interfaces.



 2.8.1. JTAG Interface

 There is one JTAG interface for LGA module debugging.




                                       Figure 6. JTAG schematic (example)



 2.8.2. SPI Master Interface

          SPIM_CLK – Output clock
          SPIM_CS – Output, chip-select
          SPIM_MOSI – Output, data to slave
          SPIM_MISO – Input, data from slave


□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                                18 / 33


                                                                                              User Manual




 Timing
 Note: This part will be updated according to the final MDM9207 datasheet.



 2.8.3. PCM Interface

 The LGA module provides one PCM digital audio interface. The PCM data bus voltage level is 1.8 V.




                                      Figure 7. PCM connection (example)



 2.8.4. I2S Interface

 PCM and I2S share the same pins on the M14Q2FG; the PCM signal pins can be configured as an I2S
 interface.

                                   Config1                    Config2
                                   PCM_SYNC                   I2S_WS
                                   PCM_DIN                    I2S_DATA0
                                   PCM_DOUT                   I2S_DATA1
                                   PCM_CLK                    I2S_SCK




                                       Figure 8. I2S connection (example)


□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                               19 / 33


                                                                                                 User Manual




 2.8.5. I2C Interface

 Adding pull-high resistors to 1.8 V through the 2.2 kΩ resistors is recommended.




                                       Figure 9. I2C connection (example)



 2.8.6. UART Interface

 There are two UART interfaces: One is a 4 bit UART for high-speed data transfer, and the other is a 2 bit
 UART for diagnostic tools and debugging.




                                    Figure 10.       UART connection (example)




□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                                20 / 33


                                                                                              User Manual




 2.8.7. ADC Interface

 An Analog to Digital Converter (ADC) input is provided by the M14Q2FG. The converter is a 16 bit
 resolution, ranging from 0.1 V to 1.7 V, with a sampling rate of 2.4 MHz.




 Layout suggestion:
       Should be protected by GND
       Should be protected from noise and other easily radiated signals




□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                              21 / 33


                                                                                                User Manual




 3. RF Specifications

 3.1. RF connections
 The M14Q2FG has three RF pads; developers may connect them via 50 Ω traces to the main board.

 ANT0_TRX pad (Pin15) – Primary RX/TX path
 ANT1_DRX pad (Pin21) – Diversity path
 ANT_GNSS pad (Pin9) – GNSS path


 3.2. RF Layout guidance
 It is recommended that grounds not be present under the surface of the RF pads in the layout. Details
 are included below.

                                                          0.5mm




                                       Pin21                      Pin15            Pin9
                                                                           0.5mm




                                                                                          GND
                                                             Layer1




                                                                                          GND
                                                                  Layer2




                                                                                          GND

                                                                  Layer3




 The RF trace between RF pads and antenna should as shorter as possible with 50ohm characteristic
 impedance.


□ Normal   □ Internal Use    Confidential     □ Restricted Confidential                           22 / 33


WNC

 The characteristic impedance depends on the dielectric of PCB, the track width and the

 ground plane spacing. Microstrip type is required. The detail simulation as below.

                                                                  %           ;                                 Eumss
      «— AppCAD — [Microstrp]
       file Calculate Select Poramaters Options    Help
            —            —                                                                                       ManMera PB
         Microstrip
                                                                      h!.)

                                                                                     Cabute20 (F4

                  a
  |             mm
                un
                 T                                                                                  a
                                                                         EketLeagh=                 1

                Dideatis. #r= [TS
                                                                         EkeiLeagh«      258
                                                                                                        Besess[]
                                                                      10Warelengh=                  1
                 t                                        (A                       \p—              foctonote
                reames          [ @=__[]                                          sn
  |             Lergtine                                                          wn—


 @ Homal                     U                    wores —MODELS



      The RF trace of the test board which was used in the FCC test is defined as below.


                                                   Length2 ( white ) =1461mil
                                                      Trace width : 20mil




                                                                                                                                        Diversity Antenna
                                                                                                                                          interface port




                  RF VO port
                Diversity path




                 RF 1/O port                                                                                                             Pr_imary Antenna
                Primary path                                                                                                               interface port




                                                                             Length1=1000mil
                                                                        Trace width : 20mil                                   |   Note:Ri= Rz2= RY=R4=0ohm




C Normal              O Internal Use              M Confidential                  o Restricted Confidential                                                  23 / 33


WNc                                                                                                 User Manual




 3.3. Antenna Guidance

           The antenna should be 50ohm characteristic impedance with the return loss of better than —10dB

 at the operation band. The antenna gain would affect the radiated power and regulator test result.


 3.4. Interference and sensitivity
 This section includes tips to assist developers in identifying the interference that may affect the
 M14Q2FG when is it used in systems.

      M interference from other wireless devices


             —=—   Harmonics, inter—modulated signal generated from wireless devices that fall in RX ranges of

                   the M14Q2FG, may result in degraded RX performance.

             —     It is highly recommended to check RX performance of entire systems within the shielding

                   environment.

      M interference from host interface


             —     High—speed signal—switching elements in systems can easily couple noise into the module

                   (Ex.: DDR memory, LCD modules, DC—DC converter).

      M Methods to avoid sources of interference




C Normal    O Internal Use   M Confidential   o Restricted Confidential                                 24 / 33


WNC

            — Antenna location is important; we recommend directing the antenna away from high—speed

                switching signals. Furthermore, the trace from the module to the antenna should be as
                short as possible and must be shielded by complete grounding.

            — The M14Q2FG is well shielded; the high—speed elements on a system should have shielding

                reserved during the early stages of development.




 3.5. Radiated sensitivity measurement
 Over—the—air testing can demonstrate the TRX ability of the whole system. Keys elements that affect the
 measurement are:


 Module ability (refer Specification)
 Antenna Gain
 System noise source

 The OTA performance should be performed in an OTA chamber.




 3.6. GNSS external circuit design
 One GNSS SAW filter, LNA, and another GNSS SAW filter need to be used between the module and
 antenna.


 3.7. Supported frequencies
                                               Table 5.    Band support
            Band                             Uplink (MHz)                 Downlink (MHz)
            LTE Band 2                       1,850—1,910                  1,930—1,990
            LTE Band 4                       1,710—1,755                  2,110—2,155
            LTE Band 5                       824—849                      869—894
            LTE Band 12                      699—716                      729—746
            Band                             Uplink (MHz)                 Downlink (MHz)
            WCDMA Band 2                     1,850—1910                   1,930—1,990
            WCDMA Band 5                     824—849                      869—894




C Normal   C Internal Use   M Confidential   o Restricted Confidential                              25 / 33


                                                                                                              User Manual




                                             Table 6. Bandwidth support
                                                                     Bandwidth
            Band
                                   1.4 MHz       3 MHz        5 MHz       10 MHz        15 MHz       20 MHz
            LTE Band 2                                                                            
            LTE Band 4                                                                            
            LTE Band 5                                                    
            LTE Band 12                                                   




                                        Table 7. Conductive Rx sensitivity
 Band                  Items                       Parameter                     Unit     Min.       Typ.      Max.
 LTE Band 2            Receive Sensitivity         10 MHz with 50 RBs            dBm                           –94.3
 LTE Band 4            Receive Sensitivity         10 MHz with 50 RBs            dBm                           –96.3
 LTE Band 5            Receive Sensitivity         10 MHz with 50 RBs            dBm                           –94.3
 LTE Band 12           Receive Sensitivity         10 MHz with 50 RBs            dBm                           –93.3
 Band                  Items                       Parameter                     Unit     Min.       Typ.      Max.
 WCDMA Band 2          Receive Sensitivity                       -               dBm                 –110      –104.7
 WCDMA Band 5          Receive Sensitivity                       -               dBm                 –110      –104.7




                                          Table8. GPS and GLONASS support band

   Band                                                Frequency                              Unit
   GPS                                              1574.4 - 1576.4                           MHz
   GLONASS                                          1597.5 - 1605.9                           MHz




□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                                           26 / 33


                                                                                   User Manual




 4. Software Interface

 4.1. Support tools
 The M14Q2FG is compatible with the following support tools:
      WNC M14Q2FG Connection Manager (WNCCM)




 4.2. USB interface
 The M14Q2FG supports 3GPP standard AT commands and proprietary AT commands; the MAL Manager
 SDK is also supported for Linux platforms.




□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                 27 / 33


                                                                                    User Manual




 5. Mechanical and Environmental Certifications

 5.1. PCBA Form Factor
 Dimensions 26.3 mm (typ.) × 23.1 mm (typ.) × 2.3 mm (typ.), tolerance: ± 0.15 mm




                                                            Top view




                                                            Right view



□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                 28 / 33


                                                                         User Manual




                                                    Bottom view




□ Normal   □ Internal Use    Confidential   □ Restricted Confidential      29 / 33


                                                                             User Manual




                                                      Pads location




                                                      Pin1 location
                                             Figure 11.    PCBA dimensions




□ Normal   □ Internal Use    Confidential    □ Restricted Confidential         30 / 33


                                                                                                 User Manual




 5.2. Labeling
 When the module is installed in the host device, the FCC ID label must be visible through a window on
 the final device or it must be visible when an access panel, door or cover is easily re-moved. If not, a
 second label must be placed on the outside of the final device that contains the following text:
 “Contains FCC ID: NKRM18Q2”

 The grantee's FCC ID can be used only when all FCC compliance requirements are met




□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                               31 / 33


                                                                         User Manual




 6. Regulatory Compliance and Certification

 6.1. Certification testing
 PTCRB, FCC and AT&T TA




□ Normal   □ Internal Use    Confidential   □ Restricted Confidential      32 / 33


                                                                                                    User Manual




 7. Safety Recommendation
 Be sure the use of this product is allowed in the country and in the environment required. The use of this
 product may be dangerous and must be avoided in the following areas:
      Where it can interfere with other electronic devices in environments such as hospitals, airports,
        and aircraft
      Where there is a risk of explosion such as gasoline stations and oil refineries

 It is the responsibility of the user to comply with his or her country’s regulations and the specific
 environmental regulations.

 Do not disassemble the product; any mark of tampering will compromise the warranty’s validity.

 We recommend following the instructions of the hardware user guides for a correct wiring of the
 product. The product must be supplied with a stabilized voltage source, and the wiring must conform to
 the security and fire-prevention regulations.

 This product must be handled with care; avoid any contact with the pins because electrostatic discharge
 may damage the product. Same caution must be taken regarding the SIM card; carefully check the
 instructions for its use. Do not insert or remove the SIM when the product is in power-saving mode.

 The system integrator is responsible of the functioning of the final product; therefore, care must be
 taken for the external components of the module as well as for project or installation issues—there may
 be a risk of disturbing the GSM network or external devices or of having an impact on device security. If
 you have any doubts, please refer to the technical documentation and the relevant regulations in force.

 Every module must be equipped with a proper antenna with specific characteristics. The antenna must
 be installed with care in order to avoid any interference with other electronic devices.




□ Normal   □ Internal Use    Confidential   □ Restricted Confidential                                   33 / 33



Document Created: 2019-09-12 08:47:03
Document Modified: 2019-09-12 08:47:03

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC