User manual

FCC ID: NKRD54A1

Users Manual

Download: PDF
FCCID_3246959

Connected Cooler Radio
Quick Start Guide


Table of Contents

1. GETTING STARTED ............................................................................................... 5
    1.1 UNPACKING INFORMATION ......................................................................................5
    1.2 INTRODUCTION......................................................................................................5

2. PORTS AND LED INDICATORS .............................................................................. 6
    2.1 PORTS .................................................................................................................6
    2.2 LED INDICATORS....................................................................................................7

3. INSTALLATION ..................................................................................................... 8

4. SPECIFICATIONS ................................................................................................ 10


Declaration of Conformity
Manufacturer:

       Name: Wistron NeWeb Corporation

       Address: 20 Park Avenue II, Hsinchu Science Park, Hsinchu 308, Taiwan, R.O.C

Radio Equipment:

       Model: D54A1

       Description: Connected Cooler Radio USA and North America version

       Radio-related Software Version: D54A1_v00.01

       Supplied Accessories and Components: NA

We, Wistron NeWeb Corporation, declare under our sole responsibility that the
product described above is in conformity with the relevant Union harmonization
legislations:

RE Directive (2014/53/EU), RoHS Directive (2011/65/EU)

The following harmonized standards and/or other relevant standards have been
applied:
1. Health and Safety (Article 3.1(a) of the RE Directive)
    EN 62311:2008
    EN 60950-1:2006/A11:2009+A1:2010+A12:2011+A2:2013
2. Electromagnetic compatibility (Article 3.1 (b) of the RE Directive)
      Final Draft ETSI EN 301 489-1 V2.1.1,
      Draft ETSI EN 301 489-3 V2.1.0
      Final Draft ETSI EN 301 489-17 V3.1.1
3. Radio frequency spectrum usage (Article 3.2 of the RE Directive)
      ETSI EN 300 328 V2.1.1
      Draft ETSI EN 300 440 V2.1.0
4. RoHS Directive (2011/65/EU)
         EN 50581:2012


Signed for and on behalf of: Wistron NeWeb Corporation

Place: 20 Park Avenue II, Hsinchu Science Park, Hsinchu 308, Taiwan, R.O.C, Date:
January 4, 2017


Name: Brian Lin; function: Technical Manager; signature:


1. Getting Started
1.1 Unpacking Information
       The Connected Cooler Radio (CCR)
       Battery notice card


                                           Battery
                                           Notice
                                           Card




1.2 Introduction
The Connected Cooler Radio (CCR) works with sensors installed in coolers to
deliver cooler information to Cloud servers for better monitoring and
management. The Wi-Fi, AGPS, and 3G/4G (based on the models you select)
functions of the CCR enables stable delivery of accurate information collected
by analog or digital sensors.


2. Ports and LED Indicators
2.1 Ports

                                         3   4         5

    1                 2




        Port               Description

1       Power              Power supply connection

2       Self-test button   The button for activating the self-test process

3       Sensor port        Connects to sensors installed in the cooler

4       Engineering        For engineering uses only

5       ANT                Antenna connection


2.2 LED Indicators

                                    Power      RF   Sensors




 LED         Indication          Description

Power        Steady green        All self-tests passed, and the battery is full.
             Blinking green      All self-tests passed, and the battery is
                                 charging
             Off                 No power connection


RF           Steady red          Other failures; for example, SIM card,
                                 battery, or Wi-Fi functions
             Blinking red        Unsuccessful antenna connection

Sensors      Steady blue         The self-test mode is running.
             Blinking blue       Detected function failure of the
                                 temperature sensor or door-open sensor.

Notes:
1) This table is only valid for checking the information after pressing the
  self-test button.
2) The Power LED (Green) will be on during Operating AC mode.


3. Installation
1. Place the CCR in the specified location (for example wall) and affix the
    screws.

                      Screw




                                                               Screw




                      Screw
    Screw type M4
2. Attach the antenna to the antenna port of the CCR.


                                                               Antenna




3. Connect the power port to the power supply.



                        Power
                    connection


4. Connect the Sensor port to the sensors.

                                    Sensors




5. Press the Self-test button. The system begins testing the CCR and the
   sensors attached to the CCR.


        Self-test
         button




6. The system will be ready for use when the Power LED returns to steady
   green, indicating the system functions normally.
   Refer to the “LED Indicators” section of this document for details if other
   LED indications are displayed.

                             Power LED


4. Specifications

Specifications

Standards        Wi-Fi: IEEE 802.11b/g/n (2.4 GHz)
                 BLE
                 LTE CAT1: B2/4/5/12; 3G: B2/5

Max. power                                 Mobile
for each
frequency                                                  Max.     Antenna
                                           Power
And                                                        Power   peak Gain
Antenna Typy                                class
                                                           (dBm)      (dBi)
Antenna Gain
                              LTE B2          3             24            4

                       LTE    LTE B4          3            24.5           4
                  Band(s)     LTE B5          3             24            1
                              LTE B12         3            24.5           2

                   UMTS       FDD II          3             25            4
                  Band(s)     FDD V           3             25            1
                                        *Antenna Type
                                          Fixed External     Antenna-For
                                          primary antenna
                  *Antenna     3G/4G
                                          Fixed internal    Antenna-For
                                          Diversity antenna


                                     WLAN

                      WiFi TX                      11b/g/n

                 Max Power(dBm)                     17.9
                Antenna peak Gain
                                                     1
                       (dBi)
                   Antenna type          internal PCB antenna


                                      BLE
                 Max Power(dBm)                      4
                Antenna peak Gain
                                                     1
                       (dBi)
                   Antenna type          internal PCB antenna



Regions and
countries
applicable


Connection    USIM 3FF, VGA for sensor(optional)
interfaces

Power input   12 V DC/ 1 A (powered by UL Listed power source.)
              Backup battery: 3.7 V > 900 mAH Li-Ion

Environment   Ambient operating temperature: –20 °C to +60 °C
              Storage temperature: –40 °C to +70 °C

Dimensions    150 mm (L) × 50 mm (W) ×30 mm (H)
              (without antenna and screws)


 5. Instruction

  Instruction

CAUTION
 Only authorized service providers shall replace battery.
 Do not disassemble or open crush, bend or deform, puncture or shred
 Do not modify or remanufacture, attempt to insert foreign objects into
    the battery, immerse or expose to water or other liquids, expose to fire,
    explosion or other hazard.
 Only use the battery with a charging system that has been qualified with
    the system per CTIA Certification Requirements for Battery System
    Compliance to IEEE 1725. Use of an unqualified battery or charger may
    present a risk of fire, explosion, leakage, or other hazard.
 Replace the battery only with another battery that has been qualified
    with the system per this standard, IEEE-Std-1725. Use of an unqualified
    battery may present a risk of fire, explosion, leakage or other hazard.
 Promptly dispose of used batteries in accordance with local regulations
 Avoid dropping the device or battery. If the device or battery is dropped,
    especially on a hard surface, and the user suspects damage, take it to a
    service center for inspection.
 Improper battery use may result in a fire, explosion or other hazard.
    For those host devices that utilize a USB port as a charging source, the
    host device's user manual shall include a statement that the device shall
    only be connected to CTIA certified adapters, products that bear the
    USB-IF logo or products that have


Specific Absorption Rate information

This mobile device meets the government’s requirements for
exposure to radio waves. Your mobile device is a radio
transmitter and receiver. The exposure standard for mobile
devices employs a unit of measurement known as the
Specific Absorption Rate, or SAR. The SAR limit adopted by
Europe is 2.0 W/kg averaged over 10 grams of tissue. Tests
for SAR are conducted using standard operating positions
with the device transmitting at its highest certified power
level in all tested frequency bands. The minimum distance
between the user and/or any bystander and the radiating
structure of the transmitter is 20cm.


FCC Regulations:

This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired
operation.

This device has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses
and can radiated radio frequency energy and, if not
installed and used in accordance with the instructions,
may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation If
this equipment does cause harmful interference to radio
or television reception, which can be determined by
turning the equipment off and on, the user is
encouraged to try to correct the interference by one or
more of the following measures:


-Reorient or relocate the receiving antenna.

-Increase the separation between the equipment and
receiver.

-Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.

-Consult the dealer or an experienced radio/TV
technician for help.



Caution: Changes or modifications not expressly
approved by the party responsible for compliance could
void the user‘s authority to operate the equipment.




RF Exposure Information

This device complies with FCC radiation exposure limits
set forth for an uncontrolled environment. In order to
avoid the possibility of exceeding the FCC radio
frequency exposure limits, human proximity to the
antenna shall not be less than 20cm (8 inches) during
normal operation.


ISED Notice

This device complies with Innovation, Science and
Economic Development Canada license-exempt RSS
standard(s). Operation is subject to the following two
conditions:

(1) this device may not cause interference, and

(2) this device must accept any interference, including
interference that may cause undesired operation of the
device.



Le présent appareil est conforme aux CNR Innovation,
Sciences et Développement économique Canada
applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions
suivantes:

(1) l'appareil ne doit pas produire de brouillage, et

(2) l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est
susceptible d'en



This Class B digital apparatus complies with Canadian
ICES-003.


Cet appareil numérique de la classe B est conforme à la
norme NMB-003 du Canada.




ISED RF Exposure Statement

This device complies with ISED RSS-102 RF exposure
limits set forth for an uncontrolled environment. In order
to avoid the possibility of exceeding the ISED RSS-102
RF exposure limits, human proximity to the antenna
shall not be less than 20cm (8 inches) during normal
operation.



Cet appareil est conforme aux limites d'exposition aux
rayonnements de la CNR-102 définies pour un
environnement non contrôlé. Afin d'éviter la possibilité
de dépasser les limites d'exposition aux fréquences
radio de la CNR-102, la proximité humaine à l'antenne
ne doit pas être inférieure à 20 cm (8 pouces) pendant le
fonctionnement normal.



Document Created: 2017-01-04 11:54:59
Document Modified: 2017-01-04 11:54:59

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC