MPE

FCC ID: NKR-VRWL25

RF Exposure Info

Download: PDF
FCCID_1381977

                                             Report No.: FR0O1232-01




            Appendix C. Maximum Permissible Exposure




FCC ID: NKR-VRWL25                            Page No.   : 1 of 3


                                                                                                 Report No.: FR0O1232-01



1. Maximum Permissible Exposure
1.1. Applicable Standard

      Systems operating under the provisions of this section shall be operated in a manner that ensures that the
      public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure.
      In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a
      mobile device whereby a distance of 0.2 m normally can be maintained between the user and the
      device.
      (A) Limits for Occupational / Controlled Exposure
                                                                                                        Averaging Time
        Frequency Range              Electric Field     Magnetic Field         Power Density (S)
                                                                                                         |E|²,|H|² or S
              (MHz)               Strength (E) (V/m)   Strength (H) (A/m)         (mW/ cm²)
                                                                                                           (minutes)
              0.3-3.0                    614                 1.63                    (100)*                    6
              3.0-30                   1842 / f             4.89 / f                (900 / f)*                 6
              30-300                    61.4                 0.163                     1.0                     6
            300-1500                                                                  F/300                    6
          1500-100,000                                                                    5                    6
      (B) Limits for General Population / Uncontrolled Exposure
                                                                                                        Averaging Time
        Frequency Range              Electric Field     Magnetic Field        Power Density (S)
                                                                                                         |E|²,|H|² or S
              (MHz)               Strength (E) (V/m)   Strength (H) (A/m)        (mW/ cm²)
                                                                                                           (minutes)
             0.3-1.34                   614                  1.63                    (100)*                   30
             1.34-30                    824/f                2.19/f                  (180/f)*                 30
              30-300                    27.5                 0.073                     0.2                    30
            300-1500                                                                 F/1500                   30
          1500-100,000                                                                 1.0                    30
      Note: f = frequency in MHz ; *Plane-wave equivalent power density

1.2. MPE Calculation Method

      E (V/m) =
                     30 × P × G                   Power Density:      Pd (W/m²) =
                                                                                    E2
                         d                                                          377
      E = Electric field (V/m)
      P = Peak RF output power (W)
      G = EUT Antenna numeric gain (numeric)
      d = Separation distance between radiator and human body (m)
      The formula can be changed to

      Pd =
              30 × P × G
               377 × d 2
      From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain
      of the used antenna, the RF power density can be obtained.

FCC ID: NKR-VRWL25                                                                                Page No.   : 2 of 3


                                                                                  Report No.: FR0O1232-01


1.3. Calculated Result and Limit

      Antenna Type : PIFA Antenna
      Max Conducted Power for IEEE 802.11g Ant. A: 24.75 dBm
                                    Peak Output                  Power Density Limit of Power
      Antenna Gain Antenna Gain                   Peak Output
                                       Power                          (S)        Density (S)    Test Result
          (dBi)      (numeric)                    Power ( mW )
                                       (dBm)                       (mW/cm²)      (mW/cm²)
            2.55        1.7989       24.7500       298.5383        0.106893          1          Complies




FCC ID: NKR-VRWL25                                                                  Page No.    : 3 of 3



Document Created: 2010-11-25 13:38:11
Document Modified: 2010-11-25 13:38:11

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC