RF Exposure Info

FCC ID: NKR-SWA

RF Exposure Info

Download: PDF
FCCID_1274625

                      RF EXPOSURE REPORT

                REPORT NO.:    SA990305L01

                  MODEL NO.:   SWA



                ACCORDING:     FCC Guidelines for Human Exposure
                               IEEE C95.1


                  APPLICANT:   Wistron NeWeb Corp.

                    ADDRESS:   20 Park Avenue II, Hsinchu Science Park,Hsinchu
                               308, Taiwan, R.O.C.




                  ISSUED BY:   Bureau Veritas Consumer Products Services (H.K.)
                               Ltd., Taoyuan Branch
         LAB LOCATION (1): No.49, Ln. 206, Wende Rd., Shangshan Tsuen,
                               Chiung Lin Hsiang, Hsin Chu Hsien, Taiwan
                               (R.O.C.)

         LAB LOCATION (2): No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen,
                               Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan




Report No.: SA990305L01                     1                  Report Format Version 3.0.1


                          RF Exposure Measurement
1. Introduction

In this document, we try to prove the safety of radiation harmfulness to the human body
for our product. The limit for Maximum Permissible Exposure (MPE) specified in FCC
1.1310 is followed. The Gain of the antenna used in this product is measured in a Fully
Anechoic Chamber (FAC) calibrated for antenna measurement in our lab, and also the
maximum total power input to the antenna is measured. Through the Friis transmission
formula and the maximum gain of the antenna, we can calculate the distance, away
from the product, where the limit of MPE is reached.
Although the Friis transmission formula is a far field assumption, the calculated result of
that is an over-prediction for near field power density. We will take that as the worst
case to specify the safety range.

2. RF Exposure Limit
According to FCC 1.1310: The criteria listed in the following table shall be used to
evaluate the environmental impact of human exposure to radio-frequency (RF) radiation
as specified in 1.1307(b)

LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

   Frequency          Electric Field   Magnetic Field   Power Density        Average Time
                                                                    2
      Range          Strength (V/m)    Strength (A/m)     (mW/cm )              (minutes)
      (MHz)
                     (A)Limits For Occupational / Control Exposures
    300-1500               …                …               F/300                    6
 1500-100,000              …                …                  5                     6
              (B)Limits For General Population / Uncontrolled Exposure
    300-1500               …                …               F/1500                  30
 1500-100,000              …                …                 1.0                   30
F = Frequency in MHz




Report No.: SA990305L01                       2                      Report Format Version 3.0.1


3. Friis Formula


Friis transmission formula : Pd = (Pout*G) / (4*pi*r 2)


where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


Pd is the limit of MPE, 1 mW/cm2. If we know the maximum Gain of the antenna and the
total power input to the antenna, through the calculation, we will know the MPE value at
distance 20cm.

Ref. : David K. Cheng, Field and Wave Electromagnetics, Second Edition,
      Page 640, Eq. (11-133).



4. EUT Operating condition
The software provided by Manufacturer enabled the EUT to transmit and receive data at
lowest, middle and highest channel individually.



5. Classification


The antenna of this product, under normal use condition, is at least 20cm away from the
body of the user. Warning statement to the user for keeping at least 20cm or more
separation distance with the antenna should be included in users manual. So, this
device is classified as Mobile Device




Report No.: SA990305L01                        3                 Report Format Version 3.0.1


6. TEST RESULTS
6.1 Antenna Gain
  The maximum Gain measured in Fully Anechoic Chamber is -2.0dBi or 0.63096
  (numeric)


  6.2 Output Power Into Antenna & RF Exposure value at distance 20cm:


                    Channel                                          Limit of
                               Output Power to   Power Density
   Channel         Frequency                                      Power Density
                               Antenna (mW)        (mW/cm2)
                     (MHz)                                          (mW/cm2)
       1              2412          269.2            0.034               1.0

       2              2438          245.5            0.031               1.0

       3              2462          223.9            0.028               1.0




Report No.: SA990305L01                     4                Report Format Version 3.0.1



Document Created: 2010-04-06 14:17:42
Document Modified: 2010-04-06 14:17:42

© 2024 FCC.report