MPE

FCC ID: NKR-P11

RF Exposure Info

Download: PDF
FCCID_4314707

                   FCC RF Exposure Report
            FCC ID                 : NKR-P11
            Equipment              : Wireless LAN Module
            Model No.              : DNSK-P11
            Brand Name             : Panasonic
            Applicant              : Wistron NeWeb Corporation
            Address                : 20 Park Avenue II, Hsinchu Science Park,
                                     Hsinchu 308,Taiwan,R.O.C.
            Standard               : 47 CFR FCC Part 2.1091
            Received Date          : Jan. 03, 2017
            Tested Date            : Jan. 05 ~ Jan. 18, 2017


      We, International Certification Corp., would like to declare that the tested sample has been
      evaluated and in compliance with the requirement of the above standards. The test results
      contained in this report refer exclusively to the product. It may be duplicated completely for
      legal use with the approval of the applicant. It shall not be reproduced except in full without
      the written approval of our laboratory.



      Reviewed by:                        Approved by:




      Along Chen / Assistant Manager      Gary Chang / Manager




Report No.: FA711706-01                                                               Page : 1 of 6
Report Version: Rev. 01


                                                   Table of Contents
1        MPE EVALUATION OF MOBILE DEVICES ......................................................................................... 4

1.1      LIMITS FOR GENERAL POPULATION/UNCONTROLLED EXPOSURE............................................. 4
1.2      MPE EVALUATION FORMULA ............................................................................................................. 4
1.3      DEVIATION FROM TEST STANDARD AND MEASUREMENT PROCEDURE ................................... 4
1.4      MEASUREMENT UNCERTAINTY ......................................................................................................... 4
1.5      MPE EVALUATION RESULTS .............................................................................................................. 5

2        TEST LABORATORY INFORMATION ................................................................................................. 6




Report No.: FA711706-01                                                                                             Page : 2 of 6
Report Version: Rev. 01


                                    Release Record
     Report No.           Version                   Description      Issued Date
    FA711706-01           Rev. 01   Initial issue                    May 31, 2019




Report No.: FA711706-01                                           Page : 3 of 6
Report Version: Rev. 01


1         MPE EVALUATION OF MOBILE DEVICES
Human exposure to RF emissions from mobile devices (47 CFR §2.1091) may be evaluated based on the
MPE limits adopted by the FCC for electric and magnetic field strength and/or power density, as appropriate,
since exposures are assumed to occur at distances of 20 cm or more from persons.



1.1       LIMITS FOR GENERAL POPULATION/UNCONTROLLED EXPOSURE
                                                                  2
      Frequency Range (MHz)               Power Density (mW /cm )           Averaging Time (minutes)
               300~1500                           F/1500                                  30
             1500~100000                            1.0                                   30


1.2       MPE EVALUATION FORMULA
                                Pt
                 Pd =
                           4 * Pi * R 2

Where
                                   2
Pd=    Power density in mW/cm
Pt=    EIRP in mW
Pi=    3.1416
R=     Measurement distance


1.3       DEVIATION FROM TEST STANDARD AND MEASUREMENT PROCEDURE
None


1.4       MEASUREMENT UNCERTAINTY
ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the emissions test
results be included in the report. The measurement uncertainties given below are based on a 95% confidence
level (based on a coverage factor (k=2)

                          Parameters                                       Uncertainty
Conducted power                                                             ±0.808 dB


Declaration of Conformity:
The test results with all measurement uncertainty excluded are presented in accordance with the regulation
limits or requirements declared by manufacturers.
Comments and Explanations:
The declared values of gain for EUT presented in the report are provided by the manufacturer, and the
manufacturer takes all the responsibilities for the accuracy of the gain.



Report No.: FA711706-01                                                                  Page : 4 of 6
Report Version: Rev. 01


1.5       MPE EVALUATION RESULTS

                  Maximum
 Frequency                        Rated   Antenna            Power
                  Conducted                       Distance               Limit                     Pass /
   Range                          Power    Gain             Density            2     Ratio*
                    Power                           (cm)           2   (mW/cm )                     Fail
   (MHz)                          (dBm)    (dBi)           (mW/cm )
                    (dBm)
 2412~2462
                      18.59        19      1.03      20      0.020        1          0.020         Pass
   (Wi-Fi)
*Ratio = Power density / Limit.




Report No.: FA711706-01                                                            Page : 5 of 6
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




2          Test laboratory information
Established in 2012, ICC provides foremost EMC & RF Testing and advisory consultation services by our
skilled engineers and technicians. Our services employ a wide variety of advanced edge test equipment and
one of the widest certification extents in the business.


International Certification Corp (EMC and Wireless Communication Laboratory), it is our definitive objective is
to institute long term, trust—based associations with our clients. The expectation we set up with our clients is
based on outstanding service, practical expertise and devotion to a certified value structure. Our passion is to
grant our clients with best EMC / RF services by oriented knowledgeable and accommodating staff.


Our Test sites are located at Linkou District and Kwei Shan District. Location map can be found on our
website http://www.icertifi.com.tw.


Linkou                                 Kwei Shan                            Kwei Shan Site II
Tel: 886—2—2601—1640                   Tel: 886—3—271—8666                  Tel: 886—3—271—8640
No. 30—2, Ding Fwu Tsuen, Lin          No. 3—1, Lane 6, Wen San 3rd St.,    No. 14—1, Lane 19, Wen San 3rd
Kou District, New Taipei City,         Kwei Shan District, Tao Yuan City    St., Kwei Shan District, Tao Yuan
Taiwan, R.0.C.                         333, Taiwan, R.0.C.                  City 333, Taiwan, R.O.C..


If you have any suggestion, please feel free to contact us as below information

Tel: 886—3—271—8666
Fax: 886—3—318—0155
Email: ICC_Service@icertifi.com.tw




==END=




Report No.: FA711706—01                                                                    Page : 6 of 6
Report Version: Rev. 01



Document Created: 2019-06-13 05:26:40
Document Modified: 2019-06-13 05:26:40

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC