Test Report 15B_rev

FCC ID: NKR-LVSK-P1

Test Report

Download: PDF
FCCID_4389771

                                                               FCC Test Report

                        Report No.: FD190606E05

                              FCC ID: NKR-LVSK-P1

                        Test Model: LVP1

                  Received Date: June 06, 2019

                          Test Date: July 05, 2019

                      Issued Date: July 31, 2019


                          Applicant: Wistron NeWeb Corp.

                            Address: 20 Park Avenue II, Hsinchu Science Park,Hsinchu 308, Taiwan, R.O.C.


                         Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                    Hsin Chu Laboratory
                     Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                  Taiwan R.O.C.
               Test Location (1): E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                  Taiwan R.O.C.
            Test Location (2): No. 49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin
                               Chu Hsien 307, Taiwan R.O.C.
         FCC Registration / 810758 / TW1085 for Test Location (1)
        Designation Number: 960022 / TW1058 for Test Location (2)




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.
Report No.: FD190606E05                                              Page No. 1 / 27                                            Report Format Version: 6.1.2


                                                                   Table of Contents
Release Control Record .................................................................................................................................. 3
1     Certificate of Conformity ......................................................................................................................... 4
2     Summary of Test Results......................................................................................................................... 5
    2.1     Measurement Uncertainty ................................................................................................................... 5
    2.2     Modification Record ............................................................................................................................ 5
3     General Information ................................................................................................................................. 6
    3.1     Description of EUT .............................................................................................................................. 6
    3.2     Features of EUT .................................................................................................................................. 6
    3.3     Operating Modes of EUT and Determination of Worst Case Operating Mode ................................... 7
    3.4     Test Program Used and Operation Descriptions ................................................................................. 7
    3.5     Primary Clock Frequencies of Internal Source ................................................................................... 7
4     Configuration and Connections with EUT ............................................................................................. 8
    4.1     Connection Diagram of EUT and Peripheral Devices ......................................................................... 8
    4.2     Configuration of Peripheral Devices and Cable Connections ............................................................. 9
5     Conducted Emissions at Mains Ports .................................................................................................. 10
    5.1     Limits ................................................................................................................................................. 10
    5.2     Test Instruments ................................................................................................................................ 10
    5.3     Test Arrangement ............................................................................................................................... 11
    5.4     Supplementary Information ................................................................................................................ 11
    5.5     Test Results ....................................................................................................................................... 12
6     Radiated Emissions up to 1 GHz .......................................................................................................... 14
    6.1     Limits ................................................................................................................................................. 14
    6.2     Test Instruments ................................................................................................................................ 15
    6.3     Test Arrangement .............................................................................................................................. 16
    6.4     Supplementary Information ............................................................................................................... 16
    6.5     Test Results ....................................................................................................................................... 17
7     Radiated Emissions above 1 GHz......................................................................................................... 19
    7.1     Limits ................................................................................................................................................. 19
    7.2     Test Instruments ................................................................................................................................ 20
    7.3     Test Arrangement .............................................................................................................................. 21
    7.4     Supplementary Information ............................................................................................................... 21
    7.5     Test Results ....................................................................................................................................... 22
8     Pictures of Test Arrangements ............................................................................................................. 24
    8.1     Conducted Emission from the AC Mains Power Port ........................................................................ 24
    8.2     Radiated Emissions up to 1 GHz ...................................................................................................... 25
    8.3     Radiated Emissions above 1 GHz .................................................................................................... 26
Appendix – Information of the Testing Laboratories ................................................................................. 27




Report No.: FD190606E05                                              Page No. 2 / 27                                               Report Format Version: 6.1.2


                                          Release Control Record


Issue No.             Description                                         Date Issued
FD190606E05           Original release.                                   July 31, 2019




Report No.: FD190606E05                      Page No. 3 / 27       Report Format Version: 6.1.2


1    Certificate of Conformity

              Product:    Home Phone Base

                Brand:    WNC

          Test Model:     LVP1

      Sample Status:      ENGINEERING SAMPLE

            Applicant:    Wistron NeWeb Corp.

            Test Date:    July 05, 2019

           Standards:     47 CFR FCC Part 15, Subpart B, Class B
                          ICES-003:2016 Issue 6, updated Apr. 2019, Class B
                          ANSI C63.4:2014




The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                             ,   Date:       July 31, 2019
                              Claire Kuan / Specialist




     Approved by :                                              ,   Date:       July 31, 2019
                                 Ken Lu / Manager




Report No.: FD190606E05                       Page No. 4 / 27                        Report Format Version: 6.1.2


                                                                                                                     s




                                                                                                             coryl
                                                                                                              (%4
                                                                                                               ced




2      Summary of Test Results

47 CFR FCC Part 15, Subpart B / ICES—003:2016 Issue 6, updated Apr. 2019, Class B
ANSI C63.4:2014
     (uS       SEsces                  Test Item                         Result/Remarks                  Verdict
    Clause      Clause
                           AC Power Line Conducted          Minimum passing Class B margin is
    15107         61       emissions                        —8.78 dB at 0.47031 MHz                        Pass
                 6.21      Radiated Emissions up to 1       Minimum passing Class B margin is              Pase
                  "C       GHz                              ~4.59 dB at 191.00 MHz
    15.109                     —       ——                     —            —             —
                 6.2.2     Radiated Emissions above 1|      Minimum passing Class B margin is              Pass
                   "C      GHz                              —8.37 dB at 7132.75 MHz
Note: Determining compliance based on the results of the compliance measurement, not taking into account
      measurement instrumentation uncertainty.



2.1     Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT:



                        Measurement                                   Frequency           Expand(igzl)JerE)ertamty
        Conducted Emissions at mains ports                      150kHz ~ 30MHz                    1.8 dB
             Radiated Emissions up to 1 GHz                      30MHz ~ 1GHz                     5.1 dB
                                                                     1GHz ~ 6GHz                  5.1 dB
             Radi
              adiated Emissi
                       Emissions above 1 GHz
                                          GH                     6GHz — 18GHz                     48 ap



2.2        Modification Record
There were no modifications required for compliance.




Report No.: FD190606E05                            Page No. 5 / 27                         Report Format Version: 6.1.2


3      General Information
3.1     Description of EUT


 Product                        Home Phone Base
 Brand                          WNC
 Test Model                     LVP1
 Sample Status                  ENGINEERING SAMPLE
 Operating Software             NA
                                DC 5V from power adapter or
 Power Supply Rating            DC 3.6V from battery
 Accessory Device               NA
 Data Cable Supplied            USB cable x 1 (Shielded, 1m)
Note:
1. The EUT needs to be supplied from power adapter or battery, the information is as below table:
Adapter
Brand              Model No.                                       Spec.
                                                                   Input: 100-240Vac, 0.4A, 50/60Hz
Lucent Trans       1A52-US0502
                                                                   Output: 5V, 2A
Battery
Brand              Model No.                                       Spec.
  WNC              BTY-LRV5000                                     DC 3.6V, 2330mAh
2. The antennas provided to the EUT, please refer to the following table:
                                     Antenna
    Antenna    RF Chain                                                       Antenna    Connector        *Cable
                          Brand         Net            Frequency range
      NO.        NO.                                                           Type        Type           Length
                                     Gain(dBi)
    LTE Main    Chain0    WNC          3.11          FDD 2: US(1850 -1910)      PIFA     i-pex(MHF)         No
                                                           FDD 4: US
    LTE Main    Chain0    WNC           2                                       PIFA     i-pex(MHF)         No
                                                  (T-Mobile)(1710-1755MHz)
    LTE Main    Chain0    WNC           0.9           FDD 5: US(824-849)        PIFA     i-pex(MHF)         No
                                                          FDD 13: US
    LTE Main    Chain0    WNC          1.25                                     PIFA     i-pex(MHF)         No
                                                    (Verizon)(777-787MHz)
    LTE Aux     Chain1    WNC          3.85          FDD 2: US(1850 -1910)      PIFA          NA            No
                                                           FDD 4: US
    LTE Aux     Chain1    WNC          2.84                                     PIFA          NA            No
                                                  (T-Mobile)(1710-1755MHz)
    LTE Aux     Chain1    WNC          1.14           FDD 5: US(824-849)        PIFA          NA            No
                                                          FDD 13: US
    LTE Aux     Chain1    WNC          1.16                                     PIFA          NA            No
                                                    (Verizon)(777-787MHz)
      GPS       Chain0    WNC          5.55            GPS(1575.42MHz)          PCB      i-pex(MHF)       80mm


3.2     Features of EUT


The tests reported herein were performed according to the method specified by Wistron NeWeb Corp., for
detailed feature description, please refer to the manufacturer's specifications or user's manual.




Report No.: FD190606E05                          Page No. 6 / 27                        Report Format Version: 6.1.2


                                                                                                        coryl
                                                                                                       (%)
                                                                                                         ezs
                                                                                                       pmnsnm




 3.3       Operating Modes of EUT and Determination of Worst Case Operating Mode


 For radiated emission test, the EUT has been pre—tested under following test modes, and test mode A was the
 worst case for final test.
                                                         Test condition
      Mode                                          Radiated emission test
                       Power Input                       Power Source                    Mode
       A              AC 120V/60Hz                       1A52—US0502                   GPS+—LTE
       B                  DC 3.6V                            Battery                   GPSA—LTE
 NOTE: The test configurations are defined by the applicant requirement.

 Test mode is presented in the report as below.
      Mode                                               Test Condition
                       Power Input                       Power Source                    Mode
       1              AC 120V/60H2z                      1A52—US0502                   GPSA—LTE




 3.4       Test Program Used and Operation Descriptions


           Turn on the power of all equipment.
N —




           Support units B (Signalling Tester MD8475A) link with EUT via LTE.
 3         Support units C (GPS simulator) link with EUT via GPS.



 3.5        Primary Clock Frequencies of Internal Source


 The EUT is provided by Wistron NeWeb Corp., for detailed internal source, please refer to the manufacturer‘s
 specifications.




 Report No.: FD190606E05                           Page No. 7 / 27                    Report Format Version: 6.1.2


4     Configuration and Connections with EUT
4.1    Connection Diagram of EUT and Peripheral Devices




                                                                                  LTE & GPS




                          (1)
              Adapter           USB type C




                          (2)
          (A)TELEPHONE            RJ11




                                                             EUT




                                     LTE                              GPS

                                   (B) Signalling Tester
                                                                    (C) GPS simulator
                                         MD8475A




Report No.: FD190606E05                           Page No. 8 / 27                       Report Format Version: 6.1.2


4.2     Configuration of Peripheral Devices and Cable Connections
 ID          Product                  Brand                 Model No.             Serial No.           FCC ID                Remarks
 A.       TELEPHONE                 WONDER                  WD-303               8C17DA02763               NA            Provided by Lab
        Signalling Tester
 B.                                   Anritsu               MD8475A              6201344422                NA            Provided by Lab
           MD8475A
 C.      GPS simulator         T&E Communication             GSG-5                 201062                  NA            Provided by Lab
Note:
1. All power cords of the above support units are non-shielded (1.8m).


 ID           Descriptions              Qty.        Length (m)   Shielding (Yes/No)         Cores (Qty.)                 Remarks
 1.            USB cable                  1             1                  Yes                   0                   Supplied by client
 2.           RJ11 cable                  1             1                  No                    0                   Provided by Lab
Note: The cores are originally attached to the cables




Report No.: FD190606E05                                  Page No. 9 / 27                                        Report Format Version: 6.1.2


5     Conducted Emissions at Mains Ports
5.1    Limits
                                            Class A (dBuV)                           Class B (dBuV)
       Frequency (MHz)
                                   Quasi-peak               Average         Quasi-peak            Average
         0.15 - 0.5                      79                   66               66 - 56             56 - 46
         0.50 - 5.0                      73                   60                 56                   46
         5.0 - 30.0                      73                   60                 60                   50
Notes: 1. The lower limit shall apply at the transition frequencies.
       2. The limit decreases linearly with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.

5.2    Test Instruments

      DESCRIPTION &                                                     CALIBRATED           CALIBRATED
                                 MODEL NO.           SERIAL NO.
     MANUFACTURER                                                           DATE                  UNTIL
Test Receiver
                              ESCS 30           100287               Apr. 16, 2019         Apr. 15, 2020
R&S
 Line-Impedance
 Stabilization Network (for
                              NSLK-8127          8127-523             Oct. 19, 2018        Oct. 18, 2019
 EUT)
 SCHWARZBECK
Line-Impedance
Stabilization Network
                              ENV216            100071               Nov. 05, 2018        Nov. 04, 2019
(for Peripheral)
R&S
RF Cable                      5D-FB             COACAB-001           Mar. 14, 2019        Mar. 13, 2020
10 dB PAD
                              STI02-2200-10     002                  Mar. 14, 2019        Mar. 13, 2020
EMEC
50 ohms Terminator            N/A               EMC-04               Nov. 14, 2018        Nov. 13, 2019
50 ohms Terminator            N/A               EMC-01               Oct. 04, 2018        Oct. 03, 2019
Software                      BVADT_Cond_
                                                NA                   NA                   NA
BVADT                         V7.3.7.4


Note:
 1. The calibration interval of the above test instruments are 12 months and the calibrations are
    traceable to NML/ROC and NIST/USA.
 2. The test was performed in Conducted Room D
 3. The VCCI Con D Registration No. is C-20005.
 4. Tested Date: July 05, 2019




Report No.: FD190606E05                       Page No. 10 / 27                        Report Format Version: 6.1.2


5.3   Test Arrangement
a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being connected
   to the power mains through a line impedance stabilization network (LISN). Other support units were
   connected to the power mains through another LISN. The two LISNs provide 50 Ohm/ 50uH of coupling
   impedance for the measuring instrument.
b. Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c. The test results of conducted emissions at mains ports are recorded of six worst margins for quasi-peak
   (mandatory) [and average (if necessary)] values against the limits at frequencies of interest unless the
   margin is 20 dB or greater.
Note: The resolution bandwidth and video bandwidth of test receiver is 9kHz for quasi-peak detection (QP) and
      average detection (AV) at frequency 0.15MHz-30MHz.




For the actual test configuration, please refer to the related Item – Photographs of the Test Configuration.



5.4   Supplementary Information


 There is not any deviation from the test standards for the test method.




Report No.: FD190606E05                        Page No. 11 / 27                         Report Format Version: 6.1.2


                                                                                                                    ied
                                                                                                                   Eusnn




5.5   Test Results


                                                          Detector Function               .
Frequency Range             150kHz ~ 3OMHz                & Resolution              gg;?;e(i@g@ggljz
                                                          Bandwidth                                   "
Input Power                 120Vac, 60Hz                  Eg‘r"'&;’t:‘o""]zn‘a'     25°C, 75%RH
Tested by                  Kevin Ko
Test Mode                  Mode 1


                                           Phase Of Power : Line (L)
       Frequency          Correction   Reading Value     Emission Level               Limit                   Margin
 No                         Factor        (dBuV)             (dBuV)                  (dBuV)                    (dB)
          (MHz)             (dB)        Q.P.    AV.        Q.P.        AV.         Q.P.        AV.         Q.P.      AV.
  1      0.15781            10.06      20.25    5.48      30.31       15.54       65.58       55.58       —35.27   —40.04
  2      0.40391            10.09      23.93   15.11      34.02       25.20       57.77       47.77       —23.75   —22.57
  3      0.47031            10.10      33.70   27.63      43.80       37.73       56.51       46.51       42.71     —8.78
  4      0.79844            10.12      21.32   11.61      31.44       21.73       56.00       46.00       —24.56   —24.27
  5      2.02344            10.21      16.67    8.57      26.88       18.78       56.00       46.00       —29.12   —27.22
  6      7.55078            10.51      16.65    7.52      27.16       18.03       60.00       50.00       —32.84   —31.97
Remarks:
         1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value




Report No.: FD190606E05                         Page No. 12 / 27                                Report Format Version: 6.1.2


                                                                                                                    ied
                                                                                                                   Eusnn




                                                           Detector Function              .
Frequency Range             150kHz ~ 3OMHz                 & Resolution             gg;?;e(i@g@ggljz
                                                           Bandwidth                                  "
Input Power                 120Vac, 60Hz                   Eg‘r"'&?‘:‘o""]zn‘a'     25°C, 75%RH
Tested by                  Kevin Ko
Test Mode                  Mode 1


                                           Phase Of Power : Neutral (N)
       Frequency          Correction   Reading Value      Emission Level              Limit                   Margin
 No                         Factor        (dBuV)              (dBuV)                 (dBuV)                    (dB)
          (MHz)              (dB)      Q.P.      AV.        Q.P.        AV.       a.P.         AV.         a.P.     AV.
  1      0.47422            10.14      27.50    21.99      37.64      3213        56.44       46.44       —18.80   —14.31
  2      0.50156            10.15      22.52     6.06      82.67      16.21       56.00       46.00       —23.33   —29.79
  3      0.53281            10.15      23.25     11.90     33.40      22.05       56.00       46.00       —22.60   —23.95
  4      0.81797            10.17      17.32     9.27      2749        19.44      56.00       46.00       —28.51   —26.56
  5      148828             10.23      12.81     6.68      23.04       16.91      56.00       46.00       —32.96   —29.09
  6      7.77344            10.62      12.21     4.16      22.83       14.78      60.00       50.00       —37.17   —35.22
Remarks:
         1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value




Report No.: FD190606E05                          Page No. 13 / 27                               Report Format Version: 6.1.2


6     Radiated Emissions up to 1 GHz
6.1    Limits
Emissions radiated outside of the specified bands, shall be according to the general radiated limits as
following:
                             Radiated Emissions Limits at 10 meters (dBμV/m)
  Frequencies    FCC 15B / ICES-003, FCC 15B / ICES-003,
                                                                   CISPR 22, Class A CISPR 22, Class B
      (MHz)             Class A                 Class B
       30-88               39                      29.5
      88-216              43.5                     33.1                    40                      30
     216-230
                          46.4                     35.6
     230-960
                                                                           47                      37
    960-1000              49.5                     43.5

                              Radiated Emissions Limits at 3 meters (dBμV/m)
    Frequencies    FCC 15B / ICES-003, FCC 15B / ICES-003,
                                                                 CISPR 22, Class A      CISPR 22, Class B
       (MHz)            Class A                Class B
        30-88             49.5                    40
       88-216              54                    43.5                   50.5                     40.5
      216-230
                           56.9                     46
      230-960
                                                                       57.5                      47.5
     960-1000              60                       54

Notes: 1. The lower limit shall apply at the transition frequencies.
       2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
       3. QP detector shall be applied if not specified.




Report No.: FD190606E05                       Page No. 14 / 27                       Report Format Version: 6.1.2


6.2    Test Instruments


      DESCRIPTION &                                                 CALIBRATED          CALIBRATED
                              MODEL NO.          SERIAL NO.
      MANUFACTURER                                                  DATE                UNTIL
      Test Receiver
                              N9038A             MY51210105          June 19, 2019      June 18, 2020
      Agilent
      Pre-Amplifier
                              ZFL-1000VH2B       AMP-ZFL-03          Oct. 30, 2018      Oct. 29, 2019
      Mini-Circuits
      Trilog Broadband
      Antenna                 VULB 9168          9168-360            Nov. 20, 2018      Nov. 19, 2019
      SCHWARZBECK
      Fixed attenuator
                              UNAT-5+            PAD-CHG-01          Sep. 27, 2018      Sep. 26, 2019
      Mini-Circuits
                              8D-FB              CHFCAB-003-2        May 02, 2019       May 01, 2020

      RF Cable                8D-FB              CHGCAB-001-2        Sep. 27, 2018      Sep. 26, 2019

                              RF-141             CHGCAB-004          Sep. 27, 2018      Sep. 26, 2019
      Software                ADT_Radiated
                                                 NA                  NA                 NA
      BVADT                   _V8.7.08
      Antenna Tower &
      Turn Table              NA                 NA                  NA                 NA
      CT

Note:
 1. The calibration interval of the above test instruments are 12 months and the calibrations are
    traceable to NML/ROC and NIST/USA.
 2. The test was performed in Chamber G room
 3. The VCCI Site Registration No. is R-20009.
 4. Tested Date: July 05, 2019




Report No.: FD190606E05                       Page No. 15 / 27                        Report Format Version: 6.1.2


6.3   Test Arrangement
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an accredited test facility.
   The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
   of a variable-height antenna tower.
c. The antenna is a broadband antenna, and its height is varied from one meter to four meters above the
   ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of
   the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
   heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find
   the maximum reading.
e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
   hold mode when the test frequency is up to 1 GHz.

Note: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
      quasi-peak detection (QP) at frequency up to 1GHz.




                                     3m




For the actual test configuration, please refer to the related Item – Photographs of the Test Configuration.




6.4   Supplementary Information


 There is not any deviation from the test standards for the test method.




Report No.: FD190606E05                        Page No. 16 / 27                         Report Format Version: 6.1.2


                                                                                                                                                     ezs
                                                                                                                                                   pmnsnm
                                                                                                                                                   veRitas



6.5   Test Results


                                                                                              Detector Function &
Frequency Range                30MHz ~ 1GHz                                                   Resolution                  Quasi—Peak (QP), 120kHz
                                                                                              Bandwidth
                                                                                              Environmental                 s     o
Input Power                    120Vac, 60Hz                                                   Conditions                  19°C, 65%RH

Tested by                      Kevin Ko
Test Made                      Mode 1

                                   Antenna Polarity & Test Distance : Horizontal at 3 m
                               Emission        l              ;     Antenna       Table                                                 Raw     Correction
 No     Frt(a&t;ezr;cy               Level                 (dIB;Ln\qll/tm)             M(erg;n          Height         Angle          Value        Factor
                            (dBuV/m)                                                                      (m)         (Degree)        (dBuV)      (dB/m)
  1        146.88           33.22 QP                         43.50                     —10.28           2.00 H            0            41.31       —8.09
  2        191.00           38.91 QP                         43.50                      ~4.59           2.00 H            0            49.52      ~10.61
  3        226.74           27.49 QP                         46.00                     —18.51           2.00 H            0            37.53      —10.04
  4        290.59           32.04 QP                         46.00                     —13.96           3.00 H          205            39.15       ~711
  5        418.19           32.85 QP                         46.00                     —13.15           4.00 H          271            36.89       ~4.04
  6        433.86           31.85 QP                         46.00                     —14.15           2.00 H          246            35.15       —3.30
Remarks:
            1. Emission Level{dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                            — Pre—Amplifier Factor (dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission level — Limit value

                          Level
                         (dBuVim)
                          ao—
                          80

                          70

                          60


                          s                                                                                                      [—
                          *                  T                  a                 5a
                          an                           3

                          20

                          10


                           o_I          1         1                 1         1           1                 1     1        1      1
                               30—     100       200            300          400         500      600     700    800      900    1000
                                                                                  Frequency (MHz)




Report No.: FD190606E05                                                  Page No. 17 / 27                                         Report Format Version: 6.1.2


                                                                                                                                                            ezs
                                                                                                                                                          pmnsnm
                                                                                                                                                          veRitas



                                                                                                     Detector Function &
Frequency Range                       30MHz ~ 1GHz                                                   Resolution                 Quasi—Peak (QP), 120kHz
                                                                                                     Bandwidth
                                                                                                     Environmental                 s     o
Input Power                           120Vac, 60Hz                                                   Conditions                  19°C, 65%RH

Tested by                             Kevin Ko
Test Mode                             Mode 1

                                            Antenna Polarity & Test Distance : Vertical at 3 m
                                      Emission        l               ;    Antenna         Table                                               Raw     Correction
 No     Frt(a'\q/ltlj_iezr;cy              Level                  ( déhn\q/'/tm )             M(erg;n          Height         Angle          Value        Factor
                                   (dBuV/m)                                                                      (m)         (Degree)        (dBuV)      (dB/m)
  1         38.95                  29.60 QP                          40.00                    —10.40           1.00 V          124            38.61       —9.01
  2         51.22                  29.72 QP                          40.00                    —10.28           1.00 V          164            38.36       —8.64
  3        117.71                  27.89 QP                          43.50                    —15.61           2.00 V          259            38.33      —10.44
  4        172.76                  29.74 QP                          43.50                    —13.76           1.00 V          251            38.69       —8.95
  5        316.22                  39.63 QP                          46.00                     —6.37           1.05 V          327            45.93       —6.30
  6        432.23                  33.21 QP                          46.00                    —12.79           1.00 V           62            36.59       —3.38
Remarks:
               1. Emission Level{dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
               2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                                                                — Pre—Amplifier Factor (dB)
               3. The other emission levels were very low against the limit.
               4. Margin value = Emission level — Limit value

                                  Level
                                (dBuVim)
                                 ao—
                                 80

                                 70

                                 60


                                 so
                                 49          ’—l                            3             N
                                                                                                                                        [—
                                       12         |g   )4
                                 30

                                 20

                                 10


                                  07          1              1          1            i           i                1      i        i      1
                                      30     100            200        300          400         500      600     700    800      900    1000
                                                                                         Frequency (MHz)




Report No.: FD190606E05                                                            Page No. 18 / 27                                      Report Format Version: 6.1.2


7     Radiated Emissions above 1 GHz
7.1    Limits
Emissions radiated outside of the specified bands, shall be according to the general radiated limits as
following:
                             Radiated Emissions Limits at 10 meters (dBμV/m)
    Frequencies    FCC 15B / ICES-003,      FCC 15B / ICES-003,
                                                                     CISPR 22, Class A       CISPR 22, Class B
       (MHz)            Class A                  Class B
    1000-3000              Avg: 49.5             Avg: 43.5              Not defined               Not defined
    Above 3000             Peak: 69.5            Peak: 63.5             Not defined               Not defined

                                 Radiated Emissions Limits at 3 meters (dBμV/m)
    Frequencies    FCC 15B / ICES-003,      FCC 15B / ICES-003,
                                                                     CISPR 22, Class A       CISPR 22, Class B
       (MHz)            Class A                  Class B
                                                                          Avg: 56                  Avg: 50
    1000-3000
                            Avg: 60               Avg: 54                 Peak: 76                 Peak: 70
                            Peak: 80              Peak: 74                Avg: 60                  Avg: 54
    Above 3000
                                                                          Peak: 80                 Peak: 74
Notes: 1. The lower limit shall apply at the transition frequencies.
       2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
       3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
          average detector, however, the peak field strength of any emission shall not exceed the maximum
          permitted average limits, specified above by more than 20dB under any condition of modulation.
Frequency Range (For unintentional radiators)
 Highest frequency generated or used in the device or
                                                               Upper frequency of measurement range (MHz)
      on which the device operates or tunes (MHz)
                          Below 1.705                                                30
                           1.705-108                                              1000
                           108-500                                                2000
                           500-1000                                               5000
                                                             5th harmonic of the highest frequency or 40GHz,
                          Above 1000
                                                                           whichever is lower




Report No.: FD190606E05                         Page No. 19 / 27                          Report Format Version: 6.1.2


7.2     Test Instruments


      DESCRIPTION &                                                 CALIBRATED          CALIBRATED
                               MODEL NO.          SERIAL NO.
      MANUFACTURER                                                  DATE                UNTIL
      Test Receiver
                               N9038A             MY51210105        June 19, 2019       June 18, 2020
      Agilent
      Horn Antenna
                               HA-07M18G-NF       0000320091110     Nov. 25, 2018       Nov. 24, 2019
      FT-RF
      Pre-Amplifier
                               8449B              3008A02578        June 12, 2019       June 11, 2020
      Agilent
                                                  150406
      RF Cable                 104 RF cable       131212            Jan. 10, 2019       Jan. 09, 2020
                                                  131205
      Software                 ADT_Radiated_
                                                  NA                NA                  NA
      BVADT                    V8.7.08
      Antenna Tower & Turn
                               NA                 NA                NA                  NA
      Table CT
      Test Receiver            N9038A             MY51210105        June 19, 2019       June 18, 2020
      Agilent
      Horn Antenna
                               HA-07M18G-NF       0000320091110     Nov. 25, 2018       Nov. 24, 2019
      FT-RF
      Fix tool for Boresight
                               BAF-01             5                 NA                  NA
      antenna tower

 Note:
 1. The calibration interval of the above test instruments are 12 months and the calibrations are
    traceable to NML/ROC and NIST/USA.
 2. The test was performed in Chamber G room
 3. Tested Date: July 05, 2019




Report No.: FD190606E05                        Page No. 20 / 27                       Report Format Version: 6.1.2


7.3   Test Arrangement
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an accredited chamber
   room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
   of a variable-height antenna tower.
c. The height of antenna can be varied from one meter to four meters, the height of adjustment depends on
   the EUT height and the antenna 3dB beamwidth both, to detect the maximum value of the field strength.
   Both horizontal and vertical polarizations of the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
   heights and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading.
e. The spectrum analyzer system was set to peak and average detect function and specified bandwidth with
   maximum hold mode when the test frequency is above 1 GHz.

Note: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and video bandwidth is 3MHz for
      Peak detection (PK) at frequency above 1GHz. The resolution bandwidth of test receiver/spectrum
      analyzer is 1 MHz for Average detection (AV) at frequency above 1GHz.



                                                     Ant. Tower
                                                                            1 - 4m
                                                                            Variable
         EUT&                            3m
        Support Units

                            Turn
                            Table         Absorber

          80cm



                                      Ground Plane

                                      Test Receiver




The test arrangement is in accordance with ANSI 63.4:2014. For the actual test configuration, please refer to
the related item – Photographs of the Test Configuration.




7.4   Supplementary Information
 There is not any deviation from the test standards for the test method.




Report No.: FD190606E05                       Page No. 21 / 27                         Report Format Version: 6.1.2


                                                                                                                          ezs
                                                                                                                        pmnsnm




7.5   Test Results


Frequency Range           1GHz ~ 10.7GHz                           gg;%?zi)étgunctlon §       is:ra(gF;K(XV), 1MHz

Input Power               120Vac, 60Hz                             Coniaione®                 21°C, 65%RH
Tested by                 Kevin Ko
Test Mode                 Mode 1

                                 Antenna Polarity & Test Distance : Horizontal at 3 m

 mo requensy
      t¥
             "Teso"
             (dBuy/m)
                                               um veen
                                             (CBuV/‘m)
                                                   (dB)
                                                        Mome
                                                         (m)
                                                              Roe vae Teur"
                                                             (Degree) (dBuv) (dB/im)
  1      1658.75          41.34 PK            74.00            —32.66       1.00 H           164          45.13         —3.79
  2      1658.75          27.79 AV            54.00            —26.21       1.00 H           360          31.58         —3.79
  3      4964.40          51.14 PK            74.00            —22.86       1.00 H           114          41.59          9.55
  4      4964.40          38.52 AV            54.00            —15.48       1.00 H            0           28.97          9.55
  5      6156.95          54.47 PK            74.00            —19.53       1.00 H           85           41.28         13.19
  6      6156.95          41.70 AV            54.00            —12.30       1.00 H           75           28.51         13.19
  7      6612.55          56.66 PK            74.00            17.34        1.00 H           225          41.08         15.58
  8      6612.55          44.23 AV            54.00             —9.77       1.00 H           214          28.65         15.58
  9      6927.90          58.52 PK            74.00            —15.48       1.00 H           103          41.85         16.67
 10      6927.90          45.37 AV            54.00             —8.63       1.00 H           360          28.70         16.67
 11      9098.80          58.64 PK            74.00            —15.36       1.00 H           333          43.70         14.94
 12      9098.80          45.25 AV            54.00             —8.75       1.00 H            0           30.31         14.94
Remarks:
            1. Emission Level{dBuV/m) = Raw Value(dBuV) + Correction Factor{dB/m)
            2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                            — Pre—Amplifier Factor (dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission level — Limit value

                        Level
                      (dBuVim)
                       BJ




                                                  1        i            i     i        i          i
                          1000 2000   4000      6000     8000      10000    12000    14000   16000    18000
                                                          Frequency (MHz)




Report No.: FD190606E05                                Page No. 22 / 27                                Report Format Version: 6.1.2


                                                                                                                       ezs
                                                                                                                     pmnsnm




Frequency Range           1GHz ~ 10.7GHz                         gg;%?zi)étgunctlon §       is:ra(gF;K(XV), 1MHz

Input Power               120Vac, 60Hz                           Coniaione®                 21°C, 65%RH
Tested by                 Kevin Ko
Test Mode                 Mode 1

                                Antenna Polarity & Test Distance : Vertical at 3 m
        Pregueney         Emission       Limit       Margin    Antgnna         Table                    Raw       Correction
 No       (MHz)             Level      (dBuV/m)       (dB)      Height         Angle                   Value        Factor
                          (dBuV/m)                                 (m)       (Degree)                 (dBuV)        (dB/m)
  1      1809.20          42.05 PK           74.00           —31.95       1.00 V           313         44.94         —2.89
  2      1809.20          29.92 AV           54.00           —24.08       1.00 V           360         32.81         —2.89
  3      3133.50          45.53 PK           74.00           —28.47       1.00 V           330         42.98          2.55
  4      3133.50          32.73 AV           54.00           —21.27       1.00 V           360         30.18          2.55
  5      3894.25          47.45 PK           74.00           —26.55       1.00 V           76          40.97          6.48
  6      3894.25          35.33 AV           54.00           —18.67       1.00 V           330         28.85          6.48
  7      5478.65          52.36 PK           74.00           —21.64       1.00 V           193         40.84         11.52
  8      5478.65          40.07 AV           54.00           —13.93       1.00 V           332         28.55         11.52
  9      7132.75          58.33 PK           74.00           —15.67       1.00 V           344         42.05         16.28
 10      7132.75          45.63 AV           54.00            —8.37       1.00 V           246         29.35         16.28
 11      8791.10          58.43 PK           74.00           15.57        1.00 V           29          42.93         15.50
 12      8791.10          44.81 AV           54.00            —9.19       1.00 V           254         29.31         15.50
Remarks:
            1. Emission Level{dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                            — Pre—Amplifier Factor (dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission level — Limit value

                        Level
                      (dBuVim)
                       BJ




                                                i        i            i     i        i       i
                          1000 2000   4000    6000     8000      10000    12000    14000   16000   18000
                                                        Frequency (MHz)




Report No.: FD190606E05                              Page No. 23 / 27                               Report Format Version: 6.1.2


Appendix – Information of the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Lin Kou EMC/RF Lab                                     Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                    Tel: 886-3-6668565
Fax: 886-2-26051924                                    Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: FD190606E05                        Page No. 27 / 27                  Report Format Version: 6.1.2



Document Created: 2019-08-07 12:41:09
Document Modified: 2019-08-07 12:41:09

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC