                                    Parameters (Profibus PA)
          Device parameter,
                                                            Factory        Setting
          parameter, menu Description
                                                            Setting        Possibilities
          identification
          4.4.1.3: Level param.   = [4.2.4]
          or                      = [4.2.5]
          4.4.1.3: Volume
          param.
          4.4.1.4: Line 2 local   Display in line 2         S/N ratio      Level
                                                                           Volume
                                                                           Temperature
                                                                           Validity
                                                                           S/N ratio
                                                                           Amplitude
                                                                           Digital output
                                                                           Analog output
          4.4.1.5: Level param.   = [4.2.4]
          or                      = [4.2.5]
          4.4.1.5: Volume
          param.
          4.4.2: Language local   = [1.1]
          4.4.3: LCD backlight    Background illumination   off            on
                                  of the LCD                               off
          4.5: Device info
          4.5.1: Power supply    Voltage range of the built- according to non-editable
                                 in power supply unit        customer
                                                             specifications
          4.5.2: Flange temper- Temperature range of the according to non-editable
          ature                  flange in °C                customer
                                                             specifications

                                                                                                       Parameters (Profibus PA)
          4.5.4: Electrical con-                             according to non-editable
          nection                                            customer
                                                             specifications                                                       mmmmm

          4.5.5:
          Antenna&flange
          4.5.5.1: Flange size   Rated width of the flange according to DN 50, 2 in
                                                             customer       DN 80, 3 in
                                                             specifications DN 100, 4 in
                                                                            DN 150, 6 in
                                                                            Special design
          4.5.5.2: Flange type Type of flange                according to DIN
                                                             customer       ANSI
                                                             specifications JIS
                                                                            Special design
          4.5.5.3: Pressure      Pressure range of the       according to non-editable
          range                  process connection          customer
                                                             specifications

   7ML19985FH01             SITRANS LR 400 – INSTRUCTION MANUAL DRAFT                        Page 59


                                   chap6.fm Page 60 Tuesday, October 9, 2001 2:26 PM




                                                                       Parameters (Profibus PA)
                                             Device parameter,
                                                                                                  Factory          Setting
                                             parameter, menu Description
                                                                                                  Setting          Possibilities
                                             identification
                                             4.5.5.4: Antenna type                                according to     Horn type long
                                                                                                  customer         Horn type short
                                                                                                  specifications   Special design
                                             4.5.5.6: Flange mate-                                according to     315/316L
                                             rial                                                 customer         Special design
                                                                                                  specifications
                                             4.5.5.7: Seal material Sealing material              according to     Teflon
                                                                                                  customer         Kalrez
                                                                                                  specifications   Viton
                                                                                                                   Perbunan
                                                                                                                   Special design
                                             4.5.6: Tag              Device identification       according to      up to any eight
                                                                                                 customer          characters
                                                                                                 specifications
                                             4.5.7: Descriptor       Measuring point descrip- according to         up to any 16 char-
                                                                     tion                        customer          acters
                                                                                                 specifications
                                             4.5.8: Message          Measuring point mes-        according to      up to any 32 char-
                                                                     sage, e.g. the date of last customer          acters
                                                                     check or clean              specifications
                                             4.5.9: Manufacturer
                                             identification
                                             4.5.9.1: Serial no.     Factory serial number        unique num- non-editable
                                                                                                  ber
                                             4.5.9.2: Order no.      Delivery order no. (deliv-   according to non-editable
                                                                     ery state)                   customer
        Parameters (Profibus PA)




                                                                                                  specifications
                                             4.5.9.3: Device revi- Device version                 Number         non-editable
                                             sion
mmmmm




                                             4.5.9.4: Software revi-                              Number           non-editable
                                             sion
                                             4.5.9.5: Hardware                                    Number           non-editable
                                             revision
                                             4.5.9.6: Antenna off- Distance sensor/flange         approx. 0.5 m non-editable
                                             set                                                  (calibration
                                                                                                  value)
                                             4.5.9.7: Reference      Internal reference dis-      approx. 106 m non-editable
                                             distance                tance                        (calibration
                                                                                                  value)
                                             5: Options




                                      Page 60                 SITRANS LR 400 – INSTRUCTION MANUAL DRAFT                    7ML19985FH01


chap6.fm Page 61 Tuesday, October 9, 2001 2:26 PM




                                    Parameters (Profibus PA)
          Device parameter,
                                                          Factory   Setting
          parameter, menu Description
                                                          Setting   Possibilities
          identification
          5.1: Enter code         Input of customer code to         Customer code
                                  enable programmability
          5.2: Customer code      Determination of cus-     0       up to 4 digit code
                                  tomer code
          5.3: Factory reset      Reset all parameters to no        yes
                                  factory setting                   no




                                                                                              Parameters (Profibus PA)
                                                                                                                         mmmmm




   7ML19985FH01             SITRANS LR 400 – INSTRUCTION MANUAL DRAFT               Page 61


                    chap7.fm Page 62 Tuesday, October 9, 2001 1:06 PM




                       Troubleshooting
                             The SITRANS LR 400 has left the factory in a fully tested condition. Carefully selected
                             components and compliance with prescribed quality standards guarantee the high
                             reliability of the SITRANS LR 400. In the unlikely event of a fault, please consult the
                             instructions in this chapter before contacting the responsible customer services.


                       Classification of faults
                             Faults occurring in the SITRANS LR 400 can be classified in the following groups:
                             •    faults caused by ambient influences: over and undertemperature, moisture,
                                  contamination by the measuring medium and other substances, mains faults,
                                  vibration
                             •    faults in the device: display, electronics, mechanics, connections
                             Please try to determine the fault and localize it as accurately as possible..
                             If the fault cannot be eliminated with the measures described, follow the instructions in
                             “Maintenance and repairs” on page 65.


                       Self-test
  Troubleshooting
mmmmm




                                 Note: The device performs a self-test every time it is switched on. It is ready for
                                 operation when the LCD displays the multi-display and the control elements can be
                                 operated.

                             If you get fault messages after the self-test, please proceed according to “Fault
                             messages” on page 64.
                             If there is a malfunction in the device, you can also activate the self-test manually with
                             Parameter 3.2.1.




                       Page 62                    Sitrans LR 400 – INSTRUCTION MANUAL                     7ML19985FH01


chap7.fm Page 63 Tuesday, October 9, 2001 1:06 PM




   Symptoms, causes and their remedy

             Symptom            Possible causes                              Remedy
                                                          Check that the power supply is connected
          No display on the Defective or missing
                                                          correctly. Replace the device fuse if necessary
          LCD               power supply
                                                          (see “Changing the device fuse” on page 65).
                                                          Connect a HART Communicator or a PC/Laptop
                              LCD is defective            with SIMATIC PDM software. If the device can be
                                                          parameterized from there, the LCD is defective.
                                                          Measure the analog current output. If the output
                                                          current is not between 3.6 mA < x < 22 mA, the
                              Electronics are defective   electronics are defective. Replace the electronics
                                                          unit as described in “Maintenance and repairs”
                                                          on page 65.
                                                          Call the fault display in Function 3.1.
          A fault message
                              Internal fault              Proceed as described in “Maintenance and
          is displayed
                                                          repairs” on page 65.
          An incorrect        The device is not
          measured value      parameterized correctly     Set the device parameters and functions
          appears after       according to the            manually.
          Auto-Setup.         application
          No measured
          value appears
          after the Auto-                                 Call the fault display in Function 3.1.




                                                                                                               Troubleshooting
          Setup               Internal fault              Proceed as described in “Maintenance and
          (measured value                                 repairs” on page 65.
          “0” and the fault




                                                                                                                          mmmmm
          display flashes)




   7ML19985FH01               Sitrans LR 400 – INSTRUCTION MANUAL                                    Page 63


                    chap7.fm Page 64 Tuesday, October 9, 2001 1:06 PM




                       Fault messages
                             The device indicates faults with a flashing letter on the right of the first line of the display.
                             It has the following meaning:
                             •    W: Warning – device is still ready for operation but faults may occur
                             •    F: Fault – sporadic fault, device conditionally ready for operation
                             •    D: continuous fault – device is not ready for operation
                             Under Parameter 3.1.x, you will find a fault log which indicates the type of the fault(s)
                             which occur. It indicates the device function status in which the fault occurred and
                             outputs an fault message in plain text.
                             The possible fault messages are as follows:


                              Function       Message                    Possible causes                    Remedy
                                                                                                   Contact your Siemens
                                          MW cable       Microwave cable not connected or line
                                                                                                   Milltronics
                                          defective      break
                                                                                                   representative
                                                                                                   Contact your Siemens
                                          Sensor
                                                         Overtemperature in device                 Milltronics
                                          defective
                              Sensor                                                               representative
                                                         Antenna contaminated, damaged or not
                                          Check antenna                                            Check the antenna
                                                         mounted
                                                                                                   Check the max.
                                          Sensor too hot Sensor temperature exceeds 85 °C          permissible ambient
  Troubleshooting




                                                                                                   and flange temperature
                                                                                                   Contact your Siemens
mmmmm




                              Electronics all messages   Internal fault                            Milltronics
                                                                                                   representative
                                                                                                   Contact your Siemens
                              Software    all messages   Internal fault                            Milltronics
                                                                                                   representative
                                                         fault in fixed target detection, fault in
                                          No valid meas.
                                                         multiple echo detection, poorly           1
                                          value
                                                         reflecting measuring medium
                                                         vessel is empty (only when sensor         Deactivate vessel
                                          Tank empty
                              Application                parameter “vessel empty detection”        empty detection if
                                          detected
                                                         active)                                   necessary
                                                                                                   Correct the parameters
                                                         incompatible parameters entered,
                                          false param.                                             listed in the next
                                                          e. g.: URV = LRV
                                                                                                   function
                                          <Parameter to                                            Perform the correction
                              Parameters                 False parameterization
                                          be corrected>                                            as indicated
                                                                                                   For service personnel
                              Service     (various)
                                                                                                   only

                             1.   Make the following modifications, starting with
                                  a. Check whether the fault still occurs after every step:
                                  b. Check the set measuring range and the dead band (Function 4.2.2.3).
                                  c. Check whether the filling speed has been correctly set (Function 4.2.2.5).
                                  d. Reduce the reflectivity (Function 4.2.2.6).
                                  e. Switch off the automatic fixed target detection (Function 4.2.3.6) if necessary.
                                  f. Switch off the multiple echo detection (Function 4.2.3.2) if necessary.


                       Page 64                    Sitrans LR 400 – INSTRUCTION MANUAL                         7ML19985FH01


chap8.fm Page 65 Tuesday, October 9, 2001 1:29 PM




   Maintenance and repairs

   Changing the device fuse

              Warning: The device fuse must only be changed by qualified personnel
              who are familiar with the installation, commissioning, and operation of
              the SITRANS LR 400.
         The device fuse is located on the power supply unit board.

         Position of device fuse and electronics cover locking:
                device fuse
                                                                    electronics cover locking




                                                                                                          Maintenance
                                                                                                                  mmmmm




         Change a defective fuse as follows:
         1.     Disconnect the device from the power supply.
         2.     If your device is in a pressure-tight housing, release the cover locking of the
                electronics cover with an Allen key (see above).
         3.     Remove the electronics cover from the housing.
         4.     If your device has an optional operating and monitoring module, pull it out of the
                front of the housing. Disconnect the plug of its cable from the socket and place the
                operating and monitoring module on one side.

              Caution! Take care not to bend or damage any of the cables.
              Touching the electronic circuit boards can damage sensitive parts.


   7ML19985FH01               Sitrans LR 400 – INSTRUCTION MANUAL                               Page 65


                chap8.fm Page 66 Tuesday, October 9, 2001 1:29 PM




                         5.     Lift the device fuse carefully from its clip with a suitable tool (tweezers, flat-tipped
                                pliers or similar) (see above), and remove it from the housing.
                         6.     Insert a new fuse. Only use original spare fuses! Press it into the clip until it snaps in
                                audibly.
                         7.     Reassemble the device in reverse order.

                              Caution! The device contains a second fuse that is not accessible via the front side.
                              This fuse is only to be replaced by the manufacturer (following a complete safety
                              check of the device).



                   Disconnecting the electronics part from the
                   mechanical part
                         For maintenance it is possible to separate the electronic enclosure of the device from the
                         mechanical part (flange) without endangering the pressure tightness of the vessel.
                         Release the threaded ring of the electronics part from the mechanical part with a hook
                         key 68/75 and remove the electronics part. Place the enclosed plastic cap on the
                         mechanical part to prevent from soiling.


                   Cleaning the antenna
                         Depending on the type of measuring material, it may be necessary to clean the antenna
                         at certain intervals to remove soiling which could affect the measuring result. You can
                         clean it without removing the flange from the vessel. Proceed as follows:
                         1.     Disconnect and remove the electronics part as described above.

                              Caution! As soon as you remove the pressure window from the mechanical part the
                              vessel is no longer pressure-tight and explosion protected!
                         2.     Unscrew the pressure window which becomes accessible after removing the
                                threaded ring with an M36 open-ended wrench and lift it off the mechanical part
  Maintenance




                                together with the white PTFE stopper.
mmmmm




                         3.     Clean the inside of the antenna with compressed air and/or a brush. Make
                                especially sure that the pressure window thread is clean. Apply fresh grease to the
                                thread as required. Check the O-rings for damage and replace them if necessary.
                         4.     If the PTFE stopper has come loose when removing from the pressure window,
                                reinsert it long end first in the mechanical part. Push it into the guide up to its
                                thickened stop.
                         5.     Place the pressure window and screw it tight.
                         6.     Reattach the electronics part to the mechanical part. You can align the rotatable
                                housing head before tightening the threaded ring.
                         7.     Check the pressure tightness of the vessel.




                   Page 66                     Sitrans LR 400 – INSTRUCTION MANUAL                        7ML19985FH01


chap9.fm Page 67 Tuesday, October 9, 2001 1:13 PM




   Certificates
         The necessary certificates are enclosed separately.




                                                                                   Certificates
                                                                                                  mmmmm




   7ML19985FH01              SITRANS LR 400 – INSTRUCTION MANUAL DRAFT   Page 67


             chap10.fm Page 68 Tuesday, October 9, 2001 1:51 PM




                Glossary
                                   Term                                         Explanation
  Glossary
mmmmm




                                                       Propagation time of the signal in the sensor, expressed as a dis-
                   Antenna offset
                                                       tance
                                                       The maximum possible value of the output signal in fault-free
                   Current limit                       operation in mA. The value of the fail signal may be above the
                                                       current limit with 24 mA.
                                                       User-defined code which protects the device against accidental
                   Customer code
                                                       programming.
                   Dead band                           Value range below the device flange declared unmeasureable.
                                                       Sensor parameter for a fuzzy rule which takes into account
                   Echo movement                       dynamic procedures in the measuring medium for example and
                                                       therefore rules out fixed targets.
                                                       Permanently installed objects inside the vessel which may cause
                   Fixed target
                                                       reflective interference, e.g. struts, agitators, feed pipes etc.
                   FMCW method                         Frequency Modulated Continuous Wave method
                   Frequency deviation                 Changing the transmission frequency in the *FMCW method.
                                                       Distance from the *LRV to the surface of the *measuring
                   Level
                                                       medium.
                                                       Lower limit of the valid measuring range as a distance from the
                   LRV
                                                       bottom inside of the vessel.
                   Measuring medium                    The (solid or liquid) contents of the vessel.
                   Multiple echo                       Sensor parameter for a fuzzy rule which detects and suppresses
                   evaluation                          multiple reflections of the measuring signal at the vessel walls.
                                                       Distance from the top of the inside of the vessel to the bottom of
                   Nozzle height
                                                       the device flange.
                   PELV                                Protected Extra Low Voltage
                   PTFE                                Polytetrafluorethylene (Teflon)
                   SELV                                Safety Extra Low Voltage
                                                       Measure of the strength of reflection of the *measuring medium
                   Signal-to-noise ratio
                                                       in the current measuring situation in dB.
                   vessel height                       Distance between the floor and top of the vessel.
                   Triple reflector                    Metal instrument formed as a cubic segment with right angles.
                                                       Upper limit of the valid measuring range as a distance from the
                   URV
                                                       bottom inside of the vessel.
                   Validity                            Measure of the certainty of the current measured value in %.




                Page 68                    Sitrans LR 400 – INSTRUCTION MANUAL DRAFT                      7ML19985FH01


sitranslrd3.book Page 69 Tuesday, October 9, 2001 10:09 AM




   Appendix I




                                                                                                 Appendix 1
   Alphabetical Parameter List




                                                                                                              mmmmm
                                                        Menu
                  Parameter Name                    Identification       Page Number
                                                       Number
          Aging                                              3.1.1.4      28
          Analog output                                      4.3          44
          Antenna offset                                     4.6.9.6      51
          Antenna type                                       4.6.5.4      49
          Antenna&flange                                     4.6.5        49
          AO select                                          4.3.1        44
          Application type                                   4.2.2.1      34
          Auto False Echo Suppression                        4.2.3.9      39
          Auto False Echo Suppression                        4.2.3.A      39
          Distance
          Auto fix distance                                  4.2.3.6      38
          Auto-Setup                                         1            25
          Bottom design                                      4.2.5.8.2    44
          Calculate                                          4.2.5.8      43
          Calibrate                                          4.2.5.8.1    42
          Calibrate/table                                    4.2.5.8      41
          Clear table                                        4.2.5.8.4    43
          Correction factor                                  4.2.2.4      35
          Current limit                                      4.3.3        45
          Current output                                     2.5          28
          Customer code                                      5.2          52
          Dead band                                          4.2.2.3      35
          Descriptor                                         4.6.7        50
          Device data                                        4            32
          Device info                                        4.6          48
          Device Revision                                    4.6.9.3      51
          Device test                                        3.2          30
          Diagnostics                                        3            28
          Digital output                                     2.6          28
          Digital output                                     4.4          46
          Display                                            2            27
          Display local                                      4.5.1.2      47
          Display parameter                                  4.5          47
          Display test                                       3.2.2        30
          Echo amplitude                                     3.4.2        31
          Echo motion                                        4.2.3.3      37
          Electrical connection                              4.6.3        49
          Enter code                                         5.1          52
          Enter table                                        4.2.5.8.2    42
          Error signal                                       4.3.4        45


   7ML19985FH01               SITRANS LR 400 – INSTRUCTION MANUAL DRAFT                Page 69


                     sitranslrd3.book Page 70 Tuesday, October 9, 2001 10:09 AM




                                                                             Menu
                                       Parameter Name                    Identification     Page Number
                                                                            Number
        Appendix 1


                               Factory reset                                      5.3        52
                               Failsafe level                                     4.2.2.7    36
mmmmm




                               Failsafe timer                                     4.2.2.8    36
                               Filling speed                                      4.2.2.5    35
                               Fix distance list                                  4.2.3.7    38
                               Flange material                                    4.6.5.6    50
                               Flange size                                        4.6.5.1    49
                               Flange temperature                                 4.6.2      48
                               Flange type                                        4.6.5.2    49
                               Function DO                                        4.4.1      46
                               Hardware revision                                  4.6.9.5    51
                               Hours > 85°C                                       3.1.1.5    28
                               HYST level                                         4.2.4.6    40
                               HYST volume                                        4.2.5.6    41
                               Language local                                     1.1        25
                               Language local                                     4.5.2      48
                               LCD lighting                                       4.5.3      48
                               Length unit                                        1.2        26
                               Length unit                                        4.1.1      32
                               Level                                              2.2        27
                               Level damping                                      1.7        27
                               Level damping                                      4.2.4.3    39
                               Level LRV                                          1.6        26
                               Level LRV                                          4.2.4.2    39
                               Level parameters                                   4.2.4      39
                               Level URV                                          1.5        26
                               Level URV                                          4.2.4.1    39
                               Line 1 local                                       4.5.1.1    47
                               Line 2 local                                       4.5.1.4    48
                               Manufacturer identification                        4.6.9      50
                               Maximum temperature                                3.1.1.2    28
                               MaxLim level                                       4.2.4.5    39
                               MaxLim Volume                                      4.2.5.5    41
                               Measuring conditions                               4.2.2      34
                               Message                                            4.6.8      50
                               Minimum temperature                                3.1.1.3    28
                               MinLim level                                       4.2.4.4    39
                               MinLim Volume                                      4.2.5.4    41
                               Multi-display                                      2.1        27
                               Multi-display                                      4.5.1      47
                               Multiple echo                                      4.2.3.2    37
                               Nozzle height                                      1.3        26
                               Nozzle height                                      4.2.1.1    33
                               Operating hours                                    3.1.1.1    28
                               Operating Parameters                               4.2        33
                               Options                                            5          52
                               Order no.                                          4.6.9.2    51

                        Page 70               SITRANS LR 400 – INSTRUCTION MANUAL DRAFT           7ML19985FH01


sitranslrd3.book Page 71 Tuesday, October 9, 2001 10:09 AM




                                                        Menu
                  Parameter Name                    Identification       Page Number
                                                       Number




                                                                                                 Appendix 1
          Other units                                        4.1.5        33
          Pipe diameter (if 4.2.1.3 = yes)                   4.2.1.3      34




                                                                                                              mmmmm
          Power supply                                       4.6.1        48
          Pressure stage                                     4.6.5.3      49
          Range Extension                                    4.2.2.9      36
          Raw value                                          3.4.1        31
          Reference distance                                 4.6.9.7      51
          S/N ratio                                          3.4.3        31
          Seal material                                      4.6.5.7      50
          Self-test                                          3.2.1        30
          Sensor damping                                     4.2.3.1      37
          Sensor parameter                                   4.2.3        36
          Sensor temperature                                 3.4.5        32
          Sensor variables                                   3.4          31
          Sensor, electronics, software,                     3.1.x        29
          application, parameters and or
          service
          Serial no.                                         4.6.9.1      50
          Show table                                         4.2.5.8.3    44
          Signal type DO                                     4.4.2        46
          Simulate AO                                        3.3.1        30
          Simulate DO                                        3.3.2        31
          Simulation                                         3.3          30
          Software revision                                  4.6.9.4      51
          Status                                             3.1          28
          Stilling pipe?                                     4.2.1.3      33
          Surface                                            4.2.2.2      34
          Tag                                                4.6.6        50
          Tank characteristic                                4.2.5.7      41
          Tank design                                        4.2.5.8.1    43
          Tank empty detection                               4.2.3.5      38
          Tank geometry                                      4.2.1        33
          Tank height                                        1.4          26
          Tank height                                        4.2.1.2      33
          Tank height                                        4.2.5.8.4    44
          Tank volume                                        4.2.5.8.3    44
          Temperature unit                                   4.1.4        33
          Units                                              4.1          32
          Validity                                           3.4.4        32
          Volume                                             2.3          27
          Volume damping                                     4.2.5.3      40
          Volume LRV                                         4.2.5.2      40
          Volume Parameters                                  4.2.5        40
          Volume unit                                        4.1.2        32
          Volume URV                                         4.2.5.1      40
          Wear                                               3.1.1        28
          Window tracking                                    4.2.3.4      38

   7ML19985FH01               SITRANS LR 400 – INSTRUCTION MANUAL DRAFT                Page 71


                     sitranslrd3.book Page 72 Tuesday, October 9, 2001 10:09 AM




        Appendix 1
mmmmm




                        Page 72               SITRANS LR 400 – INSTRUCTION MANUAL DRAFT   7ML19985FH01


sitranslrd3.book Page 73 Tuesday, October 9, 2001 10:09 AM




   Appendix II

   Programming Chart
                 Menu
             Identification                    Parameter Name                    Value
                Number
                  1                Auto-Setup
                  1.1              Language local
                  1.2              Length unit
                  1.3              Nozzle height




                                                                                                   Appendix II
                  1.4              Tank height
                  1.5              Level URV




                                                                                                                 mmmmm
                  1.6              Level LRV
                  1.7              Level damping
                  2                Display
                  2.1              Multi-display
                  2.2              Level
                  2.3              Volume
                  2.5              Current output
                  2.6              Digital output
                  3                Diagnostics
                  3.1              Status
                  3.1.1            Wear
                  3.1.x            Sensor, electronics, software, application,
                                   parameters and or service
                  3.1.1.1          Operating hours
                  3.1.1.2          Maximum temperature
                  3.1.1.3          Minimum temperature
                  3.1.1.4          Aging
                  3.1.1.5          Hours > 85°C
                  3.2              Device test
                  3.2.1            Self-test
                  3.2.2            Display test
                  3.3              Simulation
                  3.3.1            Simulate AO
                  3.3.2            Simulate DO
                  3.4              Sensor variables
                  3.4.1            Raw value
                  3.4.2            Echo amplitude
                  3.4.3            S/N ratio
                  3.4.5            Sensor temperature
                  3.4.4            Validity
                  4                Device data
                  4.1              Units
                  4.1.1            Length unit
                  4.1.2            Volume unit


   7ML19985FH01                  SITRANS LR 400 – INSTRUCTION MANUAL DRAFT               Page 73


                      sitranslrd3.book Page 74 Tuesday, October 9, 2001 10:09 AM




                                       Menu
                                   Identification                    Parameter Name             Value
                                      Number
                                        4.1.4            Temperature unit
                                        4.1.5            Other units
                                        4.2              Operating Parameters
                                        4.2.1            Tank geometry
                                        4.2.1.1          Nozzle height
                                        4.2.1.2          Tank height
                                        4.2.1.3          Stilling pipe?
                                        4.2.1.3          Pipe diameter (if 4.2.1.3 = yes)
                                        4.2.2            Measuring conditions
                                        4.2.2.1          Application type
                                        4.2.2.2          Surface
        Appendix II




                                        4.2.2.3          Dead band
mmmmm




                                        4.2.2.4          Correction factor
                                        4.2.2.5          Filling speed
                                        4.2.2.7          Failsafe level
                                        4.2.2.8          Failsafe timer
                                        4.2.2.9          Range Extension
                                        4.2.3            Sensor parameter
                                        4.2.3.1          Sensor damping
                                        4.2.3.2          Multiple echo
                                        4.2.3.3          Echo motion
                                        4.2.3.4          Window tracking
                                        4.2.3.5          Tank empty detection
                                        4.2.3.6          Auto fix distance
                                        4.2.3.7          Fix distance list
                                        4.2.3.9          Auto False Echo Suppression
                                        4.2.3.A          Auto False Echo Suppression Distance
                                        4.2.4            Level parameters
                                        4.2.4.1          Level URV
                                        4.2.4.2          Level LRV
                                        4.2.4.3          Level damping
                                        4.2.4.4          MinLim level
                                        4.2.4.5          MaxLim level
                                        4.2.4.6          HYST level
                                        4.2.5            Volume Parameters
                                        4.2.5.1          Volume URV
                                        4.2.5.2          Volume LRV
                                        4.2.5.3          Volume damping
                                        4.2.5.4          MinLim Volume
                                        4.2.5.5          MaxLim Volume
                                        4.2.5.6          HYST volume
                                        4.2.5.7          Tank characteristic
                                        4.2.5.8          Calibrate/table
                                        4.2.5.8.1                 Calibrate
                                        4.2.5.8.2                 Enter table
                                        4.2.5.8.3                 Show table
                                        4.2.5.8.4                 Clear table

                         Page 74               SITRANS LR 400 – INSTRUCTION MANUAL DRAFT        7ML19985FH01


sitranslrd3.book Page 75 Tuesday, October 9, 2001 10:09 AM




                 Menu
             Identification                    Parameter Name                Value
                Number
                  4.2.5.8          Calculate
                  4.2.5.8.1                Tank design
                  4.2.5.8.2                Bottom design
                  4.2.5.8.3                Tank volume
                  4.2.5.8.4                Tank height
                  4.3              Analog output
                  4.3.1            AO select
                  4.3.2            Volume parameter
                  4.3.2            Level parameter
                  4.3.3            Current limit
                  4.3.4            Error signal




                                                                                               Appendix II
                  4.4              Digital output




                                                                                                             mmmmm
                  4.4.1            Function DO
                  4.4.2            Signal type DO
                  4.4.3            Volume parameter
                  4.4.3            Level parameter
                  4.5              Display parameter
                  4.5.1            Multi-display
                  4.5.1.1          Line 1 local
                  4.5.1.2          Display local
                  4.5.1.3          Volume parameter
                  4.5.1.3          Level parameter
                  4.5.1.4          Line 2 local
                  4.5.1.5          Volume parameter
                  4.5.1.5          Level parameter
                  4.5.2            Language local
                  4.5.3            LCD lighting
                  4.6              Device info
                  4.6.1            Power supply
                  4.6.2            Flange temperature
                  4.6.3            Explosion protection
                  4.6.4            Electrical connection
                  4.6.5            Antenna&flange
                  4.6.5.1          Flange size
                  4.6.5.2          Flange type
                  4.6.5.3          Pressure stage
                  4.6.5.4          Antenna type
                  4.6.5.6          Flange material
                  4.6.5.7          Seal material
                  4.6.6            Tag
                  4.6.7            Descriptor
                  4.6.8            Message
                  4.6.9            Manufacturer identification
                  4.6.9.1          Serial no.
                  4.6.9.2          Order no.
                  4.6.9.3          Device Revision
                  4.6.9.4          Software revision

   7ML19985FH01                  SITRANS LR 400 – INSTRUCTION MANUAL DRAFT           Page 75


                      sitranslrd3.book Page 76 Tuesday, October 9, 2001 10:09 AM




                                       Menu
                                   Identification                    Parameter Name        Value
                                      Number
                                        4.6.9.5          Hardware revision
                                        4.6.9.6          Antenna offset
                                        4.6.9.7          Reference distance
                                        5                Options
                                        5.1              Enter code
                                        5.2              Customer code
                                        5.3              Factory reset
        Appendix II
mmmmm




                         Page 76               SITRANS LR 400 – INSTRUCTION MANUAL DRAFT   7ML19985FH01


sitranslrd3.book Page 77 Tuesday, October 9, 2001 10:09 AM




   Appendix III

   Ambient/Operating Temperature Specification


                                                                Maximum Flange and Process Temperature
                                                                       Versus Allowable Ambient


                                                      70

                                                      60

                                                      50
                                                                                                               Process
                                        Ambient (C)




                                                      40
                                                                                                             Temperature
                                                      30
                                                                                             Process Flange
                                                      20                                      Temperature

                                                      10

                                                       0




                                                                                                                                                   Appendix III
                                                           0     25   50      75    100    125     150    175      200    225




                                                                                                                                                                  mmmmm
                                                                           Process-Flange Temp Vs. Ambient




                                                      Maximum Flange and Process Temperature Versus Allowable
                                                                  Ambient (Temperature Extension)

                                   70
                                   60
               Ambient Temp. (C)




                                   50                                                                                  Process
                                   40
                                                                                                                     Temperature
                                   30                                                            Process Flange
                                   20
                                                                                                  Temperature
                                   10
                                    0
                                          0                25    50   75      100    125    150     175      200    225    250     275
                                                                           Process-Flange Temp Vs. Ambient




   7ML19985FH01                                                 SITRANS LR 400 – INSTRUCTION MANUAL DRAFT                                Page 77


                      chap14a.fm Page 78 Tuesday, October 9, 2001 1:42 PM




                         Appendix IV

                         Process Pressure/Temperature de-Rating

                                                                            Flange 22482 or 22487, FF Standard Process Seal*
                                                                             30.0


                                                                             25.0                                                                 (A) 80 mm, 100
                                  Pressure (bar, gauge)




                                                                                                                                                  mm, 150 mm,
                                                                                                                                                  PN16 or 10K
                                                                             20.0


                                                                             15.0


                                                                             10.0                                                                 (B) 80 mm, 100
                                                                                                                                                  mm, 150 mm
                                                                                                                                                  PN40
                                                                               5.0


                                                                               0.0
                                                          -100        -50              0        50         100         150         200     250

                                                                                           Temperature (°C)




                                                                 Flange 22482 or 22487, FF Process Seal for Hazardous Locations**
                                                                            45.0

                                                                            40.0

                                                                            35.0
                                                                                                                                                   80 m m, 100
                             Pressure (bar, gauge)
        Appendix IV




                                                                                                                                                   mm, 150 mm
                                                                            30.0
                                                                                                                                                   PN16 or 10K
mmmmm




                                                                            25.0


                                                                            20.0

                                                                            15.0                                                                   80 m m, 100
                                                                                                                                                   mm, 150 mm
                                                                            10.0                                                                   PN40

                                                                             5.0

                                                                             0.0
                                                          -100      -50            0       50        100         150         200     250    300

                                                                                           Temperature (°C)

                                                * standard process seal is rated to a max. of 200°C of continuous duty.
                                                *process seal for hazardous location is rate for a max of 290°C of continuous duty.



                         Page 78                                            SITRANS LR 400 – INSTRUCTION MANUAL DRAFT                               7ML19985FH01


chap14a.fm Page 79 Tuesday, October 9, 2001 1:42 PM




                                                Flange 22483 or 22488, FF Standard Process Seal*

                                                  30.0


                                                  25.0
                                                                                                                             3", 4", 6"
                                                                                                                             300 #
       Pressure (bar, gauge)




                                                  20.0


                                                  15.0


                                                  10.0                                                                       3", 4", 6"
                                                                                                                             150 #

                                                    5.0


                                                    0.0
                                 -100     -50               0         50         100         150         200         250

                                                                Temperature (°C)




                                        Flange 22483 or 22488, RF Process Seal for Hazardous Locations**

                                                 60.0


                                                 50.0
                                                                                                                                3", 4",
         Pressure (bar, gauge)




                                                                                                                                6" 300 #
                                                 40.0


                                                 30.0


                                                 20.0
                                                                                                                                3", 4",
                                                                                                                                6" 150 #
                                                 10.0
                                                                                                                                              Appendix IV
                                                                                                                                                            mmmmm
                                                  0.0
                                 -100    -50            0        50        100         150         200         250     300
                                                                  Temperature (°C)



                           * standard process seal is rated to a max. of 200°C of continuous duty.
                           *process seal for hazardous location is rated to a max of 290°C of continuous duty.