DoC Report

FCC ID: NDPOT-110

Test Report

Download: PDF
FCCID_1515234

           CERPASS TECHNOLOGY CORP.                             Report No.: TEFD1102004




                FCC DOC TEST REPORT
                                            According to

                         47 CFR, Part 2, Part 15, CISPR PUB. 22



              Applicant            : Partner Tech Corp.
                                       10FL, 233-2, Baoqiao Road, Xindian,
              Address              :
                                       New Taipei City, Taiwan
              Equipment            : Handheld Terminal
              Model No.            : OT-110
              Trade Name           : Partner




             ‚ The test result refers exclusively to the test presented test model / sample.
             ‚ Without written approval of Cerpass Technology Corp., the test report shall not be
               reproduced except in full.




Cerpass Technology Corp.                                                     Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                      Page No.     : 1 of 24


             CERPASS TECHNOLOGY CORP.                                                            Report No.: TEFD1102004


                                                                         Contents

  1. Test Configuration of Equipment under Test ........................................................................................... 4
      1.1. Feature of Equipment under Test ..................................................................................................... 4
      1.2. Test Manner ..................................................................................................................................... 5
      1.3. Description of Support Unit .............................................................................................................. 6
      1.4. General Information of Test .............................................................................................................. 7
      1.5. Measurement Uncertainty ................................................................................................................ 7
      1.6. History of this test report .................................................................................................................. 8
  2. Test of Conducted Emission ...................................................................................................................... 9
      2.1. Test Limit .......................................................................................................................................... 9
      2.2. Test Procedures ............................................................................................................................... 9
      2.3. Typical test Setup ........................................................................................................................... 10
      2.4. Measurement Equipment ............................................................................................................... 10
      2.5. Test Result and Data ...................................................................................................................... 11
      2.6. Test Photographs ........................................................................................................................... 14
  3. Test of Radiated Emission ....................................................................................................................... 15
      3.1. Test Limit ........................................................................................................................................ 15
      3.2. Test Procedures ............................................................................................................................. 15
      3.3. Typical test Setup ........................................................................................................................... 16
      3.4. Measurement Equipment ............................................................................................................... 16
      3.5. Test Result and Data (30MHz ~ 1GHz).......................................................................................... 17
      3.6. Test Result and Data (1GHz ~ 6GHz) ............................................................................................ 21
      3.7. Test Photographs (30MHz ~ 1GHz) ............................................................................................... 23
      3.8. Test Photographs (1GHz ~ 6GHz) ................................................................................................. 24
  Appendix A. Photographs of EUT………………..………………………………......…..…….…..………A1 ~ A18




Cerpass Technology Corp.                                                                                            Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                                                             Page No.          : 2 of 24


           CERPASS TECHNOLOGY CORP.                            Report No.: TEFD1102004




                     FCC DOC TEST REPORT

                                           According to

                         47 CFR, Part 2, Part 15, CISPR PUB. 22


            Applicant          : Partner Tech Corp.
                                   10FL, 233-2, Baoqiao Road, Xindian,
            Address            :
                                   New Taipei City, Taiwan
            Equipment          : Handheld Terminal

            Model No.          : OT-110

           I HEREBY CERTIFY THAT :
           The measurements shown in this test report were made in accordance with the
           procedures given in ANSI C63.4 – 2009 and the energy emitted by this equipment was
           passed CISPR PUB. 22, FCC Part 15 in both radiated and conducted emission class B
           limits.
           Testing was carried out on Jun. 23, 2011 at Cerpass Technology Corp.


          Signature




           Hill Chen
           EMC/RF B.U. Chief of Engineering Dept.




Cerpass Technology Corp.                                                   Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                    Page No.     : 3 of 24


           CERPASS TECHNOLOGY CORP.                               Report No.: TEFD1102004


 1. Test Configuration of Equipment under Test

    1.1. Feature of Equipment under Test


           CPU                        CPU Samsung S3C 6410 667MHz
           Memory                     Mobile DDR 128MB, NAND flash 256MB
           LCD                        4.3” widescreen (resolution 272*480)
           Connection Interface       WLAN 802.11 b/g, Mini USB 2.0 (Client) / 1.1 (Host)
           Audio                      Speaker, Internal microphone, earphone jack, microphone jack
           Storage                    Micro SD Card (support SDHC)
                                      Vibrator motor (for alerts)
                                      4-way direction sensor
           Special features
                                      Ambient light sensor
                                      Backup restore utility
           Battery                    Li-ion 2200mAh (with Gas Gauge)
           Ruggedness                 IP54, 1.2 meter drop test
           Operating System           Windows CE 6.0
           Dimensions                 133 * 82 * 19 mm(H x W x D)
                                      Sunlight-readable panel with power-saving function
                                      MSR Track 1, 2, 3
           Option
                                      Barcode Scanner 1D/2D
                                      RFID 13.56MHz (Mifare)
           Weight                     Approx. 220g with battery
                                      CWT \ KPC-010B
           Adapter
                                      Touch \ M8-10US05R




Cerpass Technology Corp.                                                      Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                       Page No.      : 4 of 24


             CERPASS TECHNOLOGY CORP.                            Report No.: TEFD1102004


    1.2. Test Manner
         a. During testing, the interface cables and equipment positions were varied according to
              ANSI C63.4.
         b. The complete test system included PC, Monitor, Keyboard, Mouse, Printer, Modem,
              Earphone, Micro SD Card and EUT for EMI test.
         c. The result of Conduction test as follow:
              Test Mode 1. PC Link, EUT + Module: RFID + Adapter: CWT \ KPC-010B
              Test Mode 2. PC Link, EUT + Module: RFID + Adapter: Touch \ M8-10US05R
              Test Mode 3. PC Link, EUT + Module: BCR-1D + Adapter: CWT \ KPC-010B
              Test Mode 4. PC Link, EUT + Module: BCR-2D + Adapter: CWT \ KPC-010B
              Test Mode 5. PC Link, EUT + Module: MSR + Adapter: CWT \ KPC-010B
              Test Mode 6. EUT with Cradle: Single Set, Module: BCR-2D + Adapter: CWT \ KPC-010B
              Test Mode 7. EUT with Cradle: Multi Set, Module: BCR-2D + Adapter: CWT \ KPC-010B
              cause “Test Mode 4” generated the worst test result, it was reported as final data.
        d. The result of Radiation test as follow:
              Test Mode 1. PC Link, EUT + Module: BCR-1D + Adapter: Touch \ M8-10US05R
              Test Mode 2. PC Link, EUT + Module: BCR-2D + Adapter: Touch \ M8-10US05R
              Test Mode 3. PC Link, EUT + Module: MSR + Adapter: Touch \ M8-10US05R
              Test Mode 4. PC Link, EUT + Module: RFID + Adapter: Touch \ M8-10US05R
              Test Mode 5. PC Link, EUT + Module: BCR-2D + Adapter: CWT \ KPC-010B
              Test Mode 6. EUT with Cradle: Single Set, Module: BCR-2D + Adapter: CWT \ KPC-010B
              Test Mode 7. EUT with Cradle: Multi Set, Module: BCR-2D + Adapter: CWT \ KPC-010B
              Test Mode 8. EUT with Earphone, Power from Battery
              For 30MHz ~ 1Gbps, cause “Test Mode 5” generated the worst test result, it was reported
              as final data.
              For 1Gbps ~ 6Gpbs, cause “Test Mode 3” generated the worst test result, it was reported
              as final data.
        e. An executive program, “Active Sync” under WIN 7 was executed to keep sending signals.
        f.    An executive program, “Media Player” under WIN 7 was executed to play music.
        g. An executive program, “Word Pad” under WIN 7 was executed to display the message sent
              from EUT.
        h. The EUT was executed to keep transmitting and receiving data via Wireless and Bluetooth.




Cerpass Technology Corp.                                                     Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                      Page No.     : 5 of 24


           CERPASS TECHNOLOGY CORP.                             Report No.: TEFD1102004


    1.3. Description of Support Unit


            Device               Manufacturer     Model No.   Description
                                                  DIMENSION
            PC                   DELL                         Power Cable, Adapter Unshielding 1.8m
                                                  -4600
                                                              Power Cable, Unshielding, 1.8m
            Monitor              DELL             U2410f
                                                              VGA, Shielding 1.35m
            Keyboard             DELL             SK-8175     USB, Shielding 1.85m
            Mouse                DELL             M-UV83      USB, Shielding 1.85m
                                                              Power Cable, Unshielding, 1.8m
            Printer              hp               D2660
                                                              USB, Shielding 1.6m
                                                              Power Cable, Unshielding, 1.8m
            Modem                ACEEX            DM-1414
                                                              RS232, Shielding 1.35m
            Earphone             MIC              MIC-4       Audio, Shielding 1.35m
            Micro SD Card        Kingston         2GB         N/A

           Use Cable:
            Cable     Quantity          Description
            USB              1          Unshielding, 1.8m




Cerpass Technology Corp.                                                    Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                     Page No.     : 6 of 24


           CERPASS TECHNOLOGY CORP.                             Report No.: TEFD1102004



    1.4. General Information of Test

          Test Site :                     Cerpass Technology Corp.
                                          2F-11, No. 3, Yuan Qu St., (Nankang Software Park),
                                          Taipei, Taiwan 115, R.O.C.
          Test Site Location              No.68-1, Shihbachongsi, Shihding Township,
          (OATS2-SD) :                    Taipei City 223, Taiwan, R.O.C.
          FCC Registration Number :       TW1049, TW1061, 488071, 390316

          IC Registration Number :        4934B-1, 4934D-1
                                          T-543 for Telecommunication Test
                                          C-3328 for Conducted emission test
          VCCI Registration Number :
                                          R-3013 for Radiated emission test
                                          G-97 for radiated disturbance above 1GHz

          Test Voltage:                   AC 120V/ 60Hz

                                          ANSI C63.4-2009
          Test in Compliance with:
                                          FCC Part 15 Subpart B
          Frequency Range                 Conducted: from 150kHz to 30 MHz
          Investigated :                  Radiation: from 30 MHz to 6,000 MHz
                                          The test distance of radiated emission below 1GHz from
                                          antenna to EUT is 10 M.
          Test Distance :
                                          The test distance of radiated emission above 1GHz from
                                          antenna to EUT is 3 M.


    1.5. Measurement Uncertainty


          Measurement Item           Measurement Frequency     Polarization           Uncertainty
          Conducted Emission         9 kHz ~ 30 MHz            LINE / NEUTRAL         2.71dB
                                                               Vertical               3.52 dB
                                     30 MHz ~ 1,000 MHz
                                                               Horizontal             3.39 dB
          Radiated Emission
                                                               Vertical               4.39 dB
                                     1,000 MHz ~ 18,000 MHz
                                                               Horizontal             5.25 dB




Cerpass Technology Corp.                                                      Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                       Page No.     : 7 of 24


           CERPASS TECHNOLOGY CORP.                           Report No.: TEFD1102004


    1.6. History of this test report
           „ ORIGINAL.
             Additional attachment as following record:

            Attachment No.      Issue Date      Description




Cerpass Technology Corp.                                                Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                 Page No.     : 8 of 24


           CERPASS TECHNOLOGY CORP.                             Report No.: TEFD1102004



 2. Test of Conducted Emission

    2.1. Test Limit
           Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 KHz on
           the 120 VAC power and return leads of the EUT according to the methods defined in ANSI
           C63.4-2009 Section 3.1. The EUT was placed on a nonmetallic stand in a shielded room
           0.8 meters above the ground plane as shown in section 2.2. The interface cables and
           equipment positioning were varied within limits of reasonable applications to determine the
           position produced maximum conducted emissions.

           Conducted Emission Limits:
               Frequency             Quasi Peak                   Average
                  (MHz)               (dB µ V)                    (dB µ V)
                0.15 – 0.5             66-56*                      56-46*
                0.5 – 5.0                56                          46
                5.0 – 30.0               60                          50



    2.2. Test Procedures
           a. The EUT was placed 0.4 meter from the conducting wall of the shielding room was
              kept at least 80 centimeters from any other grounded conducting surface.
           b. Connect EUT to the power mains through a line impedance stabilization network
              (LISN).
           c. All the support units are connecting to the other LISN.
           d. The LISN provides 50 ohm coupling impedance for the measuring instrument.
           e. The FCC states that a 50 ohm, 50 micro-Henry LISN should be used.
           f. Both sides of AC line were checked for maximum conducted interference.
           g. The frequency range from 150 kHz to 30 MHz was searched.
           h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with
              Maximum Hold Mode.




Cerpass Technology Corp.                                                     Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                      Page No.     : 9 of 24


           CERPASS TECHNOLOGY CORP.                               Report No.: TEFD1102004



    2.3. Typical test Setup


                                              10cm




                             EUT



                                                                                80cm

                     80cm


                                     80cm


                                                               40cm
              LISN                                                               LISN

                                                        40cm




    2.4. Measurement Equipment

           Instrument       Manufacturer    Model No.    Serial No.   Calibration Date   Valid Date
          EMI Receiver         R&S            ESCI        100443        2011/02/08       2012/02/07
              LISN          Schwarzbeck     NSLK 8127    8127-516       2011/05/05       2012/05/04
              LISN           MessTec        NNS-2/16L    02/10191       2010/07/19       2011/07/18




Cerpass Technology Corp.                                                    Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                     Page No.     : 10 of 24


           CERPASS TECHNOLOGY CORP.                           Report No.: TEFD1102004



    2.5. Test Result and Data

          Power           : AC 120V                             Pol/Phase          :   LINE
          Test Mode 4     : PC Link, EUT + Module: BCR-2D +     Temperature        :   25 °C
                              Adapter: CWT \ KPC-010B
          Memo            :                                     Humidity           :   50 %




Cerpass Technology Corp.                                                   Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                    Page No.     : 11 of 24


           CERPASS TECHNOLOGY CORP.                           Report No.: TEFD1102004




          Power           : AC 120V                             Pol/Phase          :   LINE
          Test Mode 4     : PC Link, EUT + Module: BCR-2D +     Temperature        :   25 °C
                              Adapter: CWT \ KPC-010B
          Memo            :                                     Humidity           :   50 %




Cerpass Technology Corp.                                                   Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                    Page No.     : 12 of 24


           CERPASS TECHNOLOGY CORP.                           Report No.: TEFD1102004




            Power           :   AC 120V                             Pol/Phase      :    NEUTRAL
            Test Mode 4     :   PC Link, EUT + Module: BCR-2D +     Temperature    :    25 °C
                                Adapter: CWT \ KPC-010B
            Memo            :                                       Humidity       :    50 %




        Test engineer:


Cerpass Technology Corp.                                                Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                 Page No.       : 13 of 24


           CERPASS TECHNOLOGY CORP.       Report No.: TEFD1102004



    2.6. Test Photographs




       Front View




        Rear View




Cerpass Technology Corp.                            Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200             Page No.     : 14 of 24


           CERPASS TECHNOLOGY CORP.                              Report No.: TEFD1102004


 3. Test of Radiated Emission
    3.1. Test Limit
           Radiated emissions from 30 MHz to 6,000 MHz were measured with a bandwidth of 120
           kHz according to the methods defines in ANSI C63.4-2009. The EUT was placed on a
           nonmetallic stand in the open-field site, 0.8 meter above the ground plane, as shown in
           section 3.2. The interface cables and equipment positions were varied within limits of
           reasonable applications to determine the positions producing maximum radiated emissions.
           For unintentional device, according to § 15.109(a), except for Class A digital devices, the
           field strength of radiated emissions from unintentional radiators at a distance of 3 meters
           shall not exceed the following values:

              Frequency          Distance         Radiated         Radiated
               (MHz)              Meters          (µ V / M)       (dB µ V/ M)
                30-88                3               100             40.0
                88-216                3              150              43.5
               216-960                3              200              46.0
              Above 960               3              500              54.0

           For unintentional device, according to CISPR PUB.22, for Class B digital devices, the
           general requirement of field strength of radiated emissions from intentional radiators at a
           distance of 10 meters shall not exceed the below table.

              Frequency          Distance         Radiated
                  (MHz)           Meters         (dB µ V/ M)
                30-230              10               30
               230-1000              10              37


    3.2. Test Procedures
          a. The EUT was placed on a Rota table top 0.8 meter above ground.
          b. The EUT was set 10 meters from the interference receiving antenna which was mounted
             on the top of a variable height antenna tower.
          c. The table was rotated 360 degrees to determine the position of the highest radiation.
          d. The antenna is a half wave dipole and its height is varied between one meter and four
             meters above ground to find the maximum value of the field strength both horizontal
             polarization and vertical polarization of the antenna are set to make the measurement.
          e. For each suspected emission the EUT was arranged to its worst case and then tune the
             antenna tower (from 1 M to 4 M) and turn table (from 0 degree to 360 degrees) to find the
             maximum reading.
          f. Set the test-receiver system to Peak Detect Function and specified bandwidth with
             Maximum Hold Mode.
          g. If the emission level of the EUT in peak mode was 6 dB lower than the limit specified,
             then testing will be stopped and peak values of EUT will be reported, otherwise, the
             emissions which do not have 6 dB margin will be repeated one by one using the
             quasi-peak method and reported.



Cerpass Technology Corp.                                                      Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                       Page No.     : 15 of 24


           CERPASS TECHNOLOGY CORP.                                         Report No.: TEFD1102004



    3.3. Typical test Setup

                                      Antenna


                                                                                          Equipment under Test




                                                    *    Test distance

                                                                                                                  0.8M
                                                                                               Turn Table




                                                                           Ground Plane
              Receiver




    3.4. Measurement Equipment

          Instrument       Manufacturer         Model No.           Serial No.        Calibration Date           Valid Date
           Amplifier           Agilent           8447D            2944A10531               2011/01/21            2012/01/20
        Bilog Antenna        Schaffner          CBL6112D                 22242             2011/02/09            2012/02/08
         EMI Receiver            HP              8546A            3807A00454               2010/09/27            2011/09/26
       RF Filter Section         HP              85460A           3704A00386               2010/09/27            2011/09/26
        SPECTRUM
                                R&S              FSP40               100219                2010/11/05            2011/11/04
        ANALYZER
      HORN ANTENNA             EMCO               3115                   31589             2011/05/02            2012/05/01
         Preamplifier          Agilent           8449B            3008A01954               2011/03/02            2012/03/01




Cerpass Technology Corp.                                                                    Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                                     Page No.        : 16 of 24


           CERPASS TECHNOLOGY CORP.                             Report No.: TEFD1102004




    3.5. Test Result and Data (30MHz ~ 1GHz)


            Power           : AC 110V                                Pol/Phase       : VERTICAL
            Test Mode 5     : PC Link, EUT + Module: BCR-2D +        Temperature     : 30 °C
                                Adapter: CWT \ KPC-010B
            Memo            :                                        Humidity        : 65 %




Cerpass Technology Corp.                                                  Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                   Page No.     : 17 of 24


           CERPASS TECHNOLOGY CORP.                             Report No.: TEFD1102004




            Power           : AC 110V                                Pol/Phase       :   VERTICAL
            Test Mode 5     : PC Link, EUT + Module: BCR-2D +        Temperature     :   30 °C
                                Adapter: CWT \ KPC-010B
            Memo            :                                        Humidity        :   65 %




Cerpass Technology Corp.                                                  Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                   Page No.       : 18 of 24


           CERPASS TECHNOLOGY CORP.                             Report No.: TEFD1102004




            Power           : AC 120V                                Pol/Phase       :   HORIZONTAL
            Test Mode 5     : PC Link, EUT + Module: BCR-2D +        Temperature     :   30 °C
                                Adapter: CWT \ KPC-010B
            Memo            :                                        Humidity        :   65 %




Cerpass Technology Corp.                                                  Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                   Page No.       : 19 of 24


           CERPASS TECHNOLOGY CORP.                             Report No.: TEFD1102004




            Power           : AC 120V                                Pol/Phase       :   HORIZONTAL
            Test Mode 5     : PC Link, EUT + Module: BCR-2D +        Temperature     :   30 °C
                                Adapter: CWT \ KPC-010B
            Memo            :                                        Humidity        :   65 %




     Test engineer:




Cerpass Technology Corp.                                                  Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                   Page No.       : 20 of 24


           CERPASS TECHNOLOGY CORP.                           Report No.: TEFD1102004

    3.6. Test Result and Data (1GHz ~ 6GHz)


            Power           : AC 120V                              Pol/Phase       : VERTICAL
            Test Mode 3     : PC Link, EUT + Module: MSR +         Temperature     : 25 °C
                                Adapter: Touch \ M8-10US05R
            Memo            :                                      Humidity        : 43 %




Cerpass Technology Corp.                                                Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                 Page No.     : 21 of 24


           CERPASS TECHNOLOGY CORP.                           Report No.: TEFD1102004




            Power           : AC 120V                              Pol/Phase       :   HORIZONTAL
            Test Mode 3     : PC Link, EUT + Module: MSR +         Temperature     :   25 °C
                                Adapter: Touch \ M8-10US05R
            Memo            :                                      Humidity        :   43 %




         Test engineer:




Cerpass Technology Corp.                                                Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200                                 Page No.       : 22 of 24


           CERPASS TECHNOLOGY CORP.        Report No.: TEFD1102004



    3.7. Test Photographs (30MHz ~ 1GHz)




       Front View




        Rear View




Cerpass Technology Corp.                             Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200              Page No.     : 23 of 24


           CERPASS TECHNOLOGY CORP.       Report No.: TEFD1102004



    3.8. Test Photographs (1GHz ~ 6GHz)




       Front View




        Rear View




Cerpass Technology Corp.                            Issued Date : Jul. 04, 2011
Tel:886-2-2655-8100 Fax:886-2-2655-8200             Page No.     : 24 of 24