MD 150M Manual English version

FCC ID: NDPMD150M

Users Manual

Download: PDF
FCCID_1167284

 Users’ Manual

     Product:

Mifare USB Reader

      Model:

    MD-150M


Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which
  the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:

(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
    that may cause undesired operation.

INFORMATION TO USER
To assure continued compliance, (example - use only shielded interface
cables when connecting to computer or peripheral devices) any changes
or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate this equipment.


                             MD-150M/MK-1500M User Manual




               ─ Table of contaens ─

  I. MD-150M Specification ----------------------------- 3

  II. Communication protocol -------------------------- 5

  III. MD-150M command list ------------------------------ 6

  IV. MD-150M command description ----------------- 7




                                      NOTE
This document is written by SUNION Electronic Corp. SUNION Electronic Corp.
reserves the right to change devices or specifications detailed herein at any time
without notice. Any third party is forbidden strictly to copy, edit, modify or quote the
contents of this document without written approval from SUNION electronic Corp.
SUNION’s products are not authorized for use as critical components in life support
devices or systems.
Copyright 2003~2007, SUNION Electronic Corporation All right reserved.




                                                                                       -2-


                               MD-150M User Manual



I. MD-150 M Reader Specification

    1 . Reader Specification

   Part Number                                       MD-150M

   RF Transmit Frequency            13.56 MHz
                                    Mifare_UltraLight
                                    Mifare_One(S50)

   Supported Transponder            Mifare_One(S70)
                                    Mifare_Pro(X)
                                    Mifare_DESFire
   Maximum Reading Range*           25~30 mm

   Reading Times                    150 ms

   Power Supply                     DC 5V/ 500mA Regulated

   Power Consumption                68mA in operation

   Communications Parameters        9600 baud, 8 data bits, no parity, 1 start bit, 1 stop bit

   Operating Temperature            0°C ~ 55°C

   Storage Temperature              -25°C ~ 85°C

   Storage Humidity                 5 ~ 95%RH non-condensing

   Communications Interface         Mini USB
                                    MD-150M       (PCBA) : 70mm × 30mm × 6.5mm
   Dimension (L × W × H)

                                    1 Status indicators 1 Buzzer
   Other
                                    Antenna On board or external (option)
   * Reading range may vary in depend on different transponder type.

   2 . Antenna Specification

                                         58.81mm


                                                                             5.26mm


        Wire Diameter:0.3mm
        Wire-wire distance:0.5mm


                                                                                                 -3-


                              MD-150M/MK-1500M User Manual



3. Dimension

                    4.275mm
              0
                                        70mm
   2.575mm



             0




                                                                    26.975mm
                        孔2mm
             30mm




                                                             孔2mm


                                       66.875mm




                                                                               -4-


                                   MD-150M/MK-1500M User Manual



II. Communication protocol
     This machine passes USB interface and computer end line homework in order to use a
USB connecting wire, USB of the homework is transfered to the driver of Serial Port through
can offer by institute of our company under the environment of Microsoft Windows XP/2000 (#1)
Succeed RS-232 signal USB signal simulation; So user meet device in operating system is it
increase one group communication mound newly to find on the administrator after the last
copies of machine on installation driver (COM PORT) ; Procedure of user can is it communicate
to go on through this communication between mound and copies of machine.

    MD-150M are using t he international S tandard UART communication for mat,
and support RS-232 interface with communication parameters set to 9600.N.8.1.

   DA    TA format are as follows:
                          HEADER                                  DATA          CHECK
        SOH     PT       ID1    ID2      FC1      FC2    STX      DATA   ETX     BCC
        01H Identify Reader ID           Function Code   02H      Data   03H   Checksum

     Description:
     1. SOH, STX and ET X are all cont ained with one byte and used f or control byte, the
         definition is:
        SOH= 01H, STX= 02H, ETX= 03H
          Note: The “SOH” is the start byte for current command set
                  The “STX” is the start byte for “Data”
                  The “ETX” is the end byte for “Data”
                  You will need these to judge the data length you transmitted or received; the
          data length will vary in depend on different command you given

     2. PT (Packet T ype) is used to identify w here is the message come s from; “S” means it
        comes from PC and “s” means from the reader.

     3. ID1, ID2 are the ID codes of reader, the value is always “01”.

     4. FC1 and F C2 are function codes, and relat ed to the DA TA, the relative dat a please
        refers to the next page.

     5. BCC is checksum,from SOH to ETX one byte do “xor”,then do “or” 20H.
          Ex. Reader responds:


                     SOH     “S”     “01”   “A1”   STX   “010”    ETX    BCC

                    BCC = 01H xor 53H xor 30H xor 31H xor 41H xor 31H xor 02H
                              Xor 30H xor 31H xor 30H xor 03H or 20H =33H

(#1) : Driver please to our company website download, procedure this by Prolific Technology Inc.
Offer.

                                                                                             -5-


                     MD-150M User Manual



III. USB Reader Command list

   Function   Code                    Description              Page
      1       "A0"   Switch to Stand-Alone Operation            7
      2       "A1"   Read card and acquire card ID              8
      3       "E1"   Acquire model name and firmware version    9
      4       "E2"   Reset reader                               10
      5       "K0"   Read data in specified page/block          11
      6       "K1"   Write data into specified page/block       12
      7       "K2"   Lock specified page/block                  13
      8       "K3"   Set A,B Key value of 32 Sector groups      14




                                                                      -6-


                             MD-150M/MK-1500M User Manual



IV. USB Reader command description

1. “A0” (Switch to Stand-Alone Operation)

      Controller send:
       SOH      “S”    ID1       ID2      “A”     “0”       STX    ETX    BCC

      USB Reader responds:
       SOH    “s”     ID1  ID2           “A”     “0”     STX      data    ETX     BCC

      Function description:
      (1) This function code is able to switch the reader to the “Stand-Alone Operation”.
      (2) Data response value is "Y" means successful, "N" means failure, duplicate, or no
          data.

      Example:
      Controller send:
      SOH + "S01A0" + STX + ETX + BCC

      USB Reader responds:
      SOH + "s01A0" + STX + " Y " + ETX + BCC (“Y” means Successful)




                                                                                        -7-


                             MD-150M User Manual



2. “A1” (Read card and acquire card ID)

      Controller send:
       SOH      “S”    ID1        ID2      “A”      “1”     STX      ETX     BCC

      USB Reader responds:
       SOH    “s”     ID1  ID2            “A”      “1”     STX      data     ETX     BCC

      Data description:
      (1) The format of “data” will be: Card type (1 byte) + Card ID (16 byte).
      (2) Card number is “0” ~ “9” , “A” ~ “F” 。 ex. "00000000003EA88F"。

      Function description:
      (1) Use this function to acquire card ID number through reader.
      (2) The “data” will be “N” if no card presented or failed reading; Such as: STX + “ N ” +
          ETX。

      Example:
      Controller send:
      SOH + "S01A1" + STX + ETX + BCC

      USB Reader responds:
      SOH + "s01A1" + STX + " N " + ETX + BCC (“N” means no card been read or failed
      reading)
      SOH + "s01A1" + STX + "ME007000000123456" + ETX + BCC

      Description:
      1. The “data” responded by USB Reader is;
          Card type is Multi-Page Typ.
          Card ID is "E007000000123456".




                                                                                           -8-


                             MD-150M User Manual


3. “E1” (Acquire model name and firmware version)

      Controller send:
       SOH      “S”    ID1       ID2      “E”      “1”    STX      ETX     BCC

      USB Reader responds:
       SOH    “s”     ID1         ID2      “E”      “1”     STX     date     ETX      BCC

      Data description:
      (1) The value of “data” will include current firmware version and model name.

      Function description:
      (1) Use this function to get model name and firmware version for current reader.

      Example:
      Controller send:
      SOH + "S07E1" + STX + ETX + BCC

      USB Reader responds:
      SOH + "s07E1" + STX + "V1.01 USB Reader" + ETX + BCC

      Description:
      1. The current firmware version is: V1.01and the model name is: USB Reader.
      2. Sunion reserved the right to update firmware at any time without prior notice.




                                                                                          -9-


                             MD-150M User Manual


4. “E2” ( Reset reader)

      Controller send:
       SOH      “S”    ID1        ID2      “E”     “2”      STX      ETX     BCC

      USB Reader responds:
       SOH    “s”     ID1          ID2      “E”      “2”     STX      data     ETX      BCC

      Function description:
      1. Use this function to reset USB Reader.
      2. If “data” value responded is “Y” means the set up is successful, “N” means failed,
          repeated or no data.
      3. CF Card will respond “Y” first then commence reset.

      Example:
      Controller send:
      SOH + "S01E2" + STX + ETX + BCC

      USB Reader responds:
      SOH + "s01E2" + STX + “Y” + ETX + BCC (“Y” means the set up is successful)




                                                                                          - 10 -


                               MD-150M User Manual


5. “K0”( Read data in specified page/block)

      Controller send:
       SOH      “S”    ID1         ID2      “K”      “0”       STX      DATA      ETX       BCC

      USB Reader responds:
       SOH    “s”     ID1          ID2      “K”      “0”       STX       data     ETX       BCC

      Data description:
      1. “DATA” should be entered as: Card type (1 bytes) + Page/Block number (2 bytes).
      2. When Read Mifare Card, Card type is “M ” + Page/Block number;The page/block
         number is fixed to 2 bytes. Number is “00” ~ “3F”(HEX) ,64 Blocks (0 Block is
         first)。
                   Sector 0      Block0    Block1    Block2     Block3
                   Sector 1      Block4    Block5    Block6     Block7



                                                                  AB

                                                                  Key




                   Sector 14     Block56   Block57   Block58    Block59
                   Sector 15     Block60   Block61   Block62    Block63

      Function description:
      1. Use this function to Read Mifare Card Block DATA.
      2. Every Sector last Block is A,B Key values.
      3. Read Every Sector A Key is always “0”.

      Example:
      Controller send:
      SOH + "S01K0" + STX + "M0E" + ETX + BCC

      USB Reader responds:
      SOH + "s01K0" + STX + "M00E0000456789ABCDEF1234567898765432" + ETX +
      BCC

      Description:
      1. USB Reader responded:
          "0E" ─ The information is from page/block NO.0E.
          "0000456789ABCDEF1234567898765432" ─ The dat                    a ins ide the p   age/block
          NO.0E.


                                                                                             - 11 -


                              MD-150M User Manual


6. “K1” (Write data into specified page/block)

      Controller send:
       SOH      “S”    ID1         ID2      “K”      “1”      STX     DATA       ETX   BCC

      USB Reader responds:
       SOH    “s”     ID1          ID2      “K”       “1”     STX      data      ETX   BCC

      Data description:
      1. DATA should be entered as cars type, page/block number and the information you
          want to input, just as follow:
          Card type (1 byte) + Page/block number (2 bytes) + Information (16 bytes).
      2. When Write Mifare Card, Card type is “M ” + Page/Block number;The page/block
          number is “01” ~ “3F”(HEX) ,63 Blocks。
      3. Responded “data” value will be as following:
           a. If “data” is “Y” means writing is successful.
           b. If “data” is “N” means failed or no data.
      4.   When Write data into specified page/block Sector A,B Key, please attend to
           “DATA” value. Because If Responded “data” is “Y” means writing is successful,
           Sector A,B Key was written and you can’t read this “DATA” value.

      Function description:
      1. Use this function to write information into desired block/Page of a card.
      2. Use this function to write information into desired A,B Key of a Sector.

      Example:
      Controller send:
      SOH + "S01K1" + STX + "M060000456789ABCDEF1234567898765432" + ETX + BCC

      USB Reader responds:
      SOH + "s01K1" + STX + "Y" + ETX + BCC
      (“Y” means the set up is successful)

      USB Reader responds:
      SOH + "s01K1" + STX + "N" + ETX + BCC
      (“N” means writing is failed or no data)




                                                                                        - 12 -


                             MD-150M User Manual


7. “K2” (Choose want to use Key)

      Controller send:
       SOH      “S”    ID1       ID2      “K”      “2”      STX       DATA   ETX   BCC

      USB Reader responds:
       SOH    “s”     ID1        ID2      “K”      “2”      STX       data   ETX   BCC

      Data description:
      1. “DATA” should be compare with A,B Key, sector number you want to lock, just as
           follow: Card type (1 byte) + Page/block number (2 bytes)
      2. Card type should be entered as: “M” for Multi-Page.
      3. The range of page/block number is different in different card type.
      4. “K2” function can’t lock a block of EM4135 tag. (Must use “K9”)
      5. Responded “data” value will be as following:
          If “data” is “Y” means page/block is successfully locked.
          If “data” is “N” means failed.

      Function description:
      1. Use this function to lock the data in specified page/block.
      2. Warning! This action is not recoverable, no any unlock maybe perform, use with
      extreme care!!!

      Example:
      Controller send:
      SOH + "S01K2" + STX + "M07" + ETX + BCC

      USB Reader responds:
      SOH + "s01K2" + STX + "Y" + ETX + BCC
      (“Y” means page/block is successfully locked)

      USB Reader responds:
      SOH + "s01K2" + STX + "N" + ETX + BCC
      (“N” means failed)




                                                                                     - 13 -


                             MD-150M User Manual


8. “K3” (Set A,B Key value of 32 Sector groups )

      Controller send:
       SOH      “S”    ID1        ID2      “K”      “3”     STX     DATA      ETX      BCC

      USB Reader responds:
       SOH    “s”     ID1         ID2      “K”      “3”     STX      data     ETX      BCC

      Data description:
      1. DATA should be entered as cars type, Sector group and the information you want
         to input, just as follow:Card type (1 byte) +[Sector group(2 bytes)]+ Information (12
         bytes).
      2. The range of Sector group of Reader is "01"- "20"(HEX ) 32 groups altogether.
         "01": Sector 0
         "02": Sector 1
         "03": Sector 2



         "10": Sector 15
         All groups of Sector picture of the Reader to reaching every group Sector of Mifare
         card.
      3. Responded “data” value will be as following:
         If “data” is “Y” means page/block is successfully locked.
         If “data” is “N” means failed.
      4. The content of the Reader is while wanting to write into Key value of each one
         Sector : " 123456789ABC " (12 yards of A , B Key value ).

      Function description:
      1. Use this function to Set A,B Key value of 32 Sector groups.
      2. Can just use K0 to need K2 movements effectively after needing to use this
         function.
      3. As want to revise within Mifare card , must establish Key of this Sector to the
         mould group first , Then choose to want Key of authentication , could read
         and write the materials within Mifare card in this way.

      Example:
      Controller send:
      SOH + "S01K3" + STX + " M01123456789ABC " + ETX + BCC

      USB Reader responds:
      SOH + "s01K3" + STX + "Y" + ETX + BCC
      (“Y” means page/block is successfully locked)

      Description:
      1. USB Reader responded:
          "M01" ─ Write into the first group.
          "123456789ABC " ─ The first group A,B Key Sector 0.