Test report_Wifi 2.4G_1

FCC ID: NDPM3A-2

Test Report

Download: PDF
FCCID_4312965

          CERPASS TECHNOLOGY CORP.                                               Report No.: TEFI1901083




                     FCC RADIO TEST REPORT

           Applicant         : Partner Tech Corporation
                                   10FL, 233-2, Baoqiao Road, Xindian,
           Address           :
                                   New Taipei City, Taiwan
           Equipment         : Mobile POS Terminal
                                   M3a-2, EM-110, EMC-21X0 (X could be 0-9, -, A-Z or
           Model No.         :
                                   blank )
           Trade Name : PARTNER

           FCC ID.           : NDPM3A-2

         I HEREBY CERTIFY THAT :

         The sample was received on Jan. 17, 2019 and the testing was carried out on May. 22,
         2019 at Cerpass Technology Corp. The test result refers exclusively to the test presented
         test model / sample. Without written approval of Cerpass Technology Corp., the test
         report shall not be reproduced except in full.


          Approved by:                                    Tested by:




          Mark Liao / Supervisor                          Spree Yeh / Engineer




           Laboratory Accreditation:



           Cerpass Technology Corporation Test Laboratory




Cerpass Technology Corp.                                                Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                                      Page No.      : 1 of 70
                                                                        FCC ID.       : NDPM3A-2


           CERPASS TECHNOLOGY CORP.                                                                                         Report No.: TEFI1901083



                                                                       Contents

  1.    Summary of Test Procedure and Test Results ................................................................................. 5
        1.1      Applicable Standards ................................................................................................................. 5
  2.    Test Configuration of Equipment under Test ................................................................................... 6
        2.1      Feature of Equipment ................................................................................................................. 6
        2.2      Model Difference ........................................................................................................................ 6
        2.3      Carrier Frequency of Channels .................................................................................................. 7
        2.4      Test Mode and Test Software ..................................................................................................... 8
        2.5      Description of Test System ......................................................................................................... 9
        2.6      General Information of Test ........................................................................................................ 9
        2.7      Measurement Uncertainty ........................................................................................................ 10
  3.    Test Equipment and Ancillaries Used for Tests ............................................................................. 11
  4.    Antenna Requirements ..................................................................................................................... 12
        4.1      Antenna Construction and Directional Gain ............................................................................. 12
  5.    Test of AC Power Line Conducted Emission ................................................................................. 13
        5.1      Test Limit .................................................................................................................................. 13
        5.2      Test Procedures ....................................................................................................................... 13
        5.3      Typical Test Setup .................................................................................................................... 14
        5.4      Test Result and Data ................................................................................................................ 15
        5.5      Test Photographs ..................................................................................................................... 17
  6.    Test of Radiated Spurious Emission ............................................................................................... 18
        6.1      Test Limit .................................................................................................................................. 18
        6.2      Test Procedures ....................................................................................................................... 18
        6.3      Typical Test Setup .................................................................................................................... 19
        6.4      Test Result and Data (9KHz ~ 30MHz) .................................................................................... 20
        6.5      Test Result and Data (30MHz ~ 1GHz) .................................................................................... 20
        6.6      Test Result and Data (1GHz ~ 25GHz) .................................................................................... 22
        6.7      Restricted Bands of Operation ................................................................................................. 46
        6.8      Test Photographs (30MHz ~ 1GHz) ......................................................................................... 47
        6.9      Test Photographs (1GHz ~ 25GHz) ......................................................................................... 48
  7.    Test of Conducted Spurious Emission ........................................................................................... 49
        7.1      Test Limit .................................................................................................................................. 49
        7.2      Test Procedure ......................................................................................................................... 49
        7.3      Test Setup Layout .................................................................................................................... 49
        7.4      Test Result and Data ................................................................................................................ 49
  8.    On Time, Duty Cycle and Measurement methods ......................................................................... 58
        8.1      Test Limit .................................................................................................................................. 58
        8.2      Test Procedure ......................................................................................................................... 58
        8.3      Test Setup Layout .................................................................................................................... 58
        8.4      Test Result and Data ................................................................................................................ 58
  9.    6dB Bandwidth Measurement Data ................................................................................................. 60
        9.1      Test Limit .................................................................................................................................. 60
        9.2      Test Procedures ....................................................................................................................... 60


Cerpass Technology Corp.                                                                                        Issued date        : May. 27, 2019
T-FD-509-0 Ver 1.0                                                                                              Page No.           : 2 of 70
                                                                                                                FCC ID.            : NDPM3A-2


           CERPASS TECHNOLOGY CORP.                                                                                         Report No.: TEFI1901083

        9.3      Test Setup Layout .................................................................................................................... 60
        9.4      Test Result and Data (6dB Bandwidth) .................................................................................... 60
        9.5      Test Result and Data (99% Bandwidth) ................................................................................... 61
  10.   Maximum Peak and Average Output Power ................................................................................... 66
        10.1     Test Limit .................................................................................................................................. 66
        10.2     Test Procedures ....................................................................................................................... 66
        10.3     Test Setup Layout .................................................................................................................... 66
        10.4     Test Result and Data ................................................................................................................ 67
  11.   Power Spectral Density .................................................................................................................... 68
        11.1     Test Limit .................................................................................................................................. 68
        11.2     Test Procedures ....................................................................................................................... 68
        11.3     Test Setup Layout .................................................................................................................... 68
        11.4     Test Result and Data ................................................................................................................ 68




Cerpass Technology Corp.                                                                                        Issued date        : May. 27, 2019
T-FD-509-0 Ver 1.0                                                                                              Page No.           : 3 of 70
                                                                                                                FCC ID.            : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                     Report No.: TEFI1901083



                                 History of this test report


            Report No.     Issue Date      Description

            TEFI1901083    May. 27, 2019   Original




Cerpass Technology Corp.                                       Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                             Page No.      : 4 of 70
                                                               FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                             Report No.: TEFI1901083


  1. Summary of Test Procedure and Test Results
     1.1 Applicable Standards
          ANSI C63.4:2014
          ANSI C63.10:2013
          FCC Rules and Regulations Part 15 Subpart C §15.247
          KDB558074
          KDB662911
          KDB447498

               FCC Rule      . Description of Test                             Result

                 15.203      . Antenna Requirement                              PASS

                 15.207      . AC Power Line Conducted Emission                 PASS

                 15.209
                             . Radiated Spurious Emission                       PASS
                 15.205

               15.247(d)     . Conducted Spurious Emission                      PASS

              15.247(a)(2)   . 6dB Bandwidth                                    PASS

               15.247(b)     . Maximum Peak and Average Output Power            PASS

               15.247(e)     . Power Spectral Density                           PASS

                 2.1091      . Radio Frequency Exposure                         PASS

           This EUT has been also tested and complied with the requirement of FCC Part 15, Subpart B,
           recorded in a separate test report (TEFV1901083).




Cerpass Technology Corp.                                               Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                                     Page No.      : 5 of 70
                                                                       FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                                Report No.: TEFI1901083


 2. Test Configuration of Equipment under Test
     2.1 Feature of Equipment
                                    BT / BLE: 2400-2483.5MHz
           Frequency Range          802.11b/g/n: 2400-2483.5MHz
                                    802.11a/n/ac: 5150-5250MHz, 5725-5850MHz
                                    BT: GFSK, π/4-DQPSK, 8DPSK
                                    BLE: GFSK
           Modulation Type          802.11b: CCK, DQPSK, DBPSK
                                    802.11g/n/a: BPSK, QPSK, 16QAM, 64QAM
                                    802.11ac: BPSK, QPSK, 16QAM, 64QAM, 256QAM
           Modulation Technology    DSSS, OFDM, FHSS, DTS
                                    BT:
                                    GFSK: 1Mbps, π/4-DQPSK: 2Mbps, 8DPSK: 3Mbps
                                    BLE:
                                    GFSK: 1Mbps
                                    WLAN:
           Data Rate
                                    802.11b: 1, 2, 5.5, 11Mbps
                                    802.11g: 6, 9, 12, 18, 24, 36, 48, 54Mbps
                                    802.11n: MCS0 – MCS7, HT20/40
                                    802.11a: 6, 9, 12, 18, 24, 36, 48, 54Mbps
                                    802.11ac: MCS0 – MCS9, VHT20/40/80
           Antenna Type             Dipole Antenna
                                    2400-2483.5MHz: 6.92dBi
           Antenna Gain             5150-5250MHz: 4.12dBi
                                    5725-5850MHz: 5.55dBi
                                    EDAC \ EA1024P1
           Adapter                  Input: 100-240Vac, 1A, 50-60Hz
                                    Output: 12Vdc, 3A
         Note:
         1. For a more detailed features description, please refer to the manufacturer’s specifications
         or the User's Manual.


     2.2 Model Difference
         M3a-2, EM-110, EMC-21X0 (X could be 0-9, -, A-Z or blank) for marketing purpose.




Cerpass Technology Corp.                                                  Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                                        Page No.      : 6 of 70
                                                                          FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                          Report No.: TEFI1901083


     2.3 Carrier Frequency of Channels
         802.11b, 802.11g, 802.11n HT20 (2412MHz~2462MHz)
                 Channel        Frequency(MHz)           Channel        Frequency(MHz)
                   *01               2412                  07                2442
                    02               2417                  08                2447
                    03               2422                  09                2452
                    04               2427                  10                2457
                    05               2432                  *11               2462
                   *06               2437                   ---               ---

         802.11n HT40 (2422MHz~2452MHz)
               Channel         Frequency(MHz)             Channel       Frequency(MHz)
                  ---                  ---                   07              2442
                  ---                  ---                   08              2447
                 *03                 2422                    *09             2452
                  04                 2427                     ---             ---
                  05                 2432                     ---             ---
                 *06                 2437                     ---             ---
         Note: Channels remarked * are selected to perform test.




Cerpass Technology Corp.                                            Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                                  Page No.      : 7 of 70
                                                                    FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                            Report No.: TEFI1901083

     2.4 Test Mode and Test Software
         a. During testing, the interface cables and equipment positions were varied according to ANSI
            C63.10.
         b. The complete test system included Notebook and EUT for RF test.
         c. An executive program, ”qdart: win.4.8_installer_00039.311-11-17_08_03_48” was executed to
            transmit and receive data via WLAN.
         d. The following test modes were performed for the test:
              AC Power Line Conducted Emission
              Test Mode Operating Description
                   1     802.11b (1Mbps) , Adapter:EDAC \ EA1024P1
                   2     802.11g (6Mbps) , Adapter:EDAC \ EA1024P1
                   3     802.11n HT20 (6.5Mbps) , Adapter:EDAC \ EA1024P1
                   4     802.11n HT40 (13.5Mbps) , Adapter:EDAC \ EA1024P1
              caused “Test Mode 2” generated the worst case, it was reported as the final data.
              Radiated Spurious Emission (below 1GHz)
              Test Mode Operating Description
                   1     802.11b (1Mbps) , Adapter:EDAC \ EA1024P1
                   2     802.11g (6Mbps) , Adapter:EDAC \ EA1024P1
                   3     802.11n HT20 (6.5Mbps) , Adapter:EDAC \ EA1024P1
                   4     802.11n HT40 (13.5Mbps) , Adapter:EDAC \ EA1024P1
              caused “Test Mode 2” generated the worst case, it was reported as the final data.
              Radiated Spurious Emission (above 1GHz)
              Test Mode Operating Description
                   1     802.11b (1Mbps) , Adapter:EDAC \ EA1024P1
                   2     802.11g (6Mbps) , Adapter:EDAC \ EA1024P1
                   3     802.11n HT20 (6.5Mbps) , Adapter:EDAC \ EA1024P1
                   4     802.11n HT40 (13.5Mbps) , Adapter:EDAC \ EA1024P1
              caused “Test Mode 1~4” generated the worst case, they were reported as the final data.
              Conducted Spurious Emission, 6dB Bandwidth, Maximum Peak Output Power,
              Power Spectral Density
              Test Mode Operating Description
                   1     802.11b (1Mbps) , Adapter:EDAC \ EA1024P1
                   2     802.11g (6Mbps) , Adapter:EDAC \ EA1024P1
                   3     802.11n HT20 (6.5Mbps) , Adapter:EDAC \ EA1024P1
                   4     802.11n HT40 (13.5Mbps) , Adapter:EDAC \ EA1024P1
              caused “Test Mode 1~4” generated the worst case, they were reported as the final data.




Cerpass Technology Corp.                                              Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                                    Page No.      : 8 of 70
                                                                      FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                           Report No.: TEFI1901083


     2.5 Description of Test System
                                           RF Conducted
           Equipment        Brand            Model       Length/Type       Power cord/Length/Type
           Notebook         DELL        Latitude E5450       N/A             Adapter / 1.8m / NS
           USB cable         N/A              N/A         1.2m / SH                 N/A
                                        Radiated Emissions
           Equipment        Brand            Model       Length/Type       Power cord/Length/Type
           Notebook         ASUS            P2430U           N/A             Adapter / 1.8m / NS
           USB cable         N/A              N/A         1.2m / SH                 N/A
                                  AC Power Line Conducted Emission
           Equipment        Brand            Model       Length/Type       Power cord/Length/Type
           Notebook         ASUS            P2430U           N/A             Adapter / 1.8m / NS
           USB cable         N/A              N/A         1.2m / SH                 N/A



     2.6 General Information of Test
                             Cerpass Technology Corporation Test Laboratory
                             Address: No.10, Ln. 2, Lianfu St., Luzhu Dist., Taoyuan City 33848,
                             Taiwan (R.O.C.)
                             Tel:+886-3-3226-888
                             Fax:+886-3-3226-881
                             Address: No.68-1, Shihbachongsi, Shihding Township,
                             New Taipei City 223, Taiwan, R.O.C.
          Test Site          Tel: +886-2-2663-8582
                             FCC       TW1079, TW1061,TW1439
                             IC        4934E-1, 4934E-2
                                       T-2205 for Telecommunication test
                                       C-4663 for Conducted emission test
                             VCCI
                                       R-4399, R-4218 for Radiated emission test
                                       G-10812, G-10813 for radiated disturbance above 1GHz
          Frequency Range    Conducted: from 150kHz to 30 MHz
          Investigated:      Radiation: from 30 MHz to 25,000MHz

          Test Distance:     The test distance of radiated emission from antenna to EUT is 3 M.




Cerpass Technology Corp.                                             Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                                   Page No.      : 9 of 70
                                                                     FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                         Report No.: TEFI1901083


     2.7 Measurement Uncertainty
          Measurement Item                           Uncertainty
          Radiated Spurious Emission(9KHz~30MHz)     ±3.405dB
          Radiated Spurious Emission(30MHz~1GHz)     ±5.326dB
          Radiated Spurious Emission(1GHz~25GHz)     ±5.918dB
          Conducted Spurious Emission                ±2.156dB
          6dB Bandwidth                              ±4.401%
          20dB Bandwidth                             ±4.40%
          Occupied Bandwidth                         ±4.41%
          Peak Output Power(Conducted Power Meter)   ±1.31dB
          Dwell Time                                 ±0.11%
          Power Spectral Density                     ±2.146dB
          Duty Cycle                                 ±0.17%




Cerpass Technology Corp.                                           Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                                 Page No.      : 10 of 70
                                                                   FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                      Report No.: TEFI1901083


  3. Test Equipment and Ancillaries Used for Tests
        Test Item     Radiated Emissions
        Test Site     Semi Anechoic Room(3M02-NK)
       Instrument          Manufacturer       Model No      Serial No  Calibration Date Valid Date
     Bilog Antenna         Schwarzbeck        VULB9168        275        2018/09/17 2019/09/16
  Active Loop Antenna          EMCO             6507         40855       2018/05/22 2019/05/21
     Horn Antenna              EMCO              3115        31601       2018/09/26 2019/09/25
     Horn Anrenna              EMCO             3116         31974       2018/09/07 2019/09/06
      EMI Receiver     ROHDE & SCHWARZ          ESCI         101423      2018/06/11 2019/06/10
   Spectrum Analyzer ROHDE & SCHWARZ           FSP 40        100219      2018/07/03 2019/07/02
       Preamplifier             EM             EM330         60659       2018/03/20 2019/03/19
       Preamplifier    EMC INSTRUMENTS EMC051845SE           980333      2018/09/18 2019/09/17
  Cable-3in1(30M-1G) HARBOUR INDUSTRIES         LL142      CCE1315       2018/04/20 2019/04/19
  Cable-0.5m(1G-40G)         Rapidtek       40GHZ 50CM 38MS-38MS50314    2018/03/27 2019/03/26
   Cable-3m(1G-40G)          Rapidtek       40GHZ 300CM 38MS-38MS300314 2018/03/27 2019/03/26
   Cable-8m(1G-40G)          Rapidtek       40GHZ 800CM 38MS-38MS800314 2018/03/27 2019/03/26
           E3                 AUDIX          v8.2014-8-6   RK-000529         NA             NA


        Test Item     RF Conducted
        Test Site     RFCON01-NK
       Instrument          Manufacturer         Model No       Serial No        Calibration Date Valid Date
    Spectrum Analyzer ROHDE & SCHWARZ            FSP 40         100219            2018/07/03     2019/07/02
       Attenuator           KEYSIGHT             8491B        MY39250705          2018/09/04     2019/09/03
     TEMP & HUMI
                           T-MACHINE            TMJ-9712      T-12-040111          2018/08/30   2019/08/29
       CHAMBER
      Power Sensor           Anritsu            MA2411B        1207295             2019/04/11   2020/04/10


        Test Item       AC Power Line Conducted Emission
         Test Site      CON01-NK
       Instrument            Manufacturer         Model No     Serial No        Calibration Date Valid Date
     EMI Receiver        ROHDE & SCHWARZ           ESCI         100821            2018/9/12      2019/09/11
    Line Impedance
                            Schwarzbeck          NSLK 8127     8127-740            2018/6/13    2019/06/12
  Stabilization Network
      Pulse Limiter      ROHDE & SCHWARZ          ESH3-Z2      101933               2018/9/4    2019/09/03
            E3                 AUDIX            v8.2014-8-6   RK-000531               NA           NA




Cerpass Technology Corp.                                        Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                              Page No.      : 11 of 70
                                                                FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                               Report No.: TEFI1901083

  4. Antenna Requirements

     4.1 Antenna Construction and Directional Gain
            Antenna Type       Dipole Antenna
                               2400-2483.5MHz: 6.92dBi
            Antenna Gain       5150-5250MHz: 4.12dBi
                               5725-5850MHz: 5.55dBi

           2400-2483.5MHz
           For Power directional gain= Gant= 6.92 dBi
           For PSD directional gain = Gant= 6.92 dBi

           5150-5250MHz
           For Power directional gain= Gant= 4.12 dBi
           For PSD directional gain = Gant= 4.12 dBi

           5725-5850MHz
           For Power directional gain= Gant= 5.55 dBi
           For PSD directional gain = Gant = 5.55 dBi




Cerpass Technology Corp.                                 Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                       Page No.      : 12 of 70
                                                         FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                                Report No.: TEFI1901083


  5. Test of AC Power Line Conducted Emission

     5.1 Test Limit

           Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of 9 KHz,
           according to the methods defined in ANSI C63.4-2014. The EUT was placed on a
           nonmetallic stand in a shielded room 0.8 meters above the ground plane. The interface
           cables and equipment positioning were varied within limits of reasonable applications to
           determine the position produced maximum conducted emissions.

                     Frequency           Quasi Peak               Average
                       (MHz)              (dB µ V)                (dB µ V)
                     0.15 – 0.5            66-56*                  56-46*
                     0.5 – 5.0                56                     46
                     5.0 – 30.0               60                     50
           *Decreases with the logarithm of the frequency.



     5.2 Test Procedures
           a. The EUT was placed 0.4 meter from the conducting wall of the shielding room was kept
              at least 80 centimeters from any other grounded conducting surface.
           b. Connect EUT to the power mains through a line impedance stabilization network (LISN).
           c. All the support units are connecting to the other LISN.
           d. The LISN provides 50 ohm coupling impedance for the measuring instrument.
           e. The FCC states that a 50 ohm, 50 micro-Henry LISN should be used.
           f. Both sides of AC line were checked for maximum conducted interference.
           g. The frequency range from 150 kHz to 30 MHz was searched.
           h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth with
              Maximum Hold Mode.




Cerpass Technology Corp.                                                  Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                                        Page No.      : 13 of 70
                                                                          FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                           Report No.: TEFI1901083




     5.3 Typical Test Setup


                                                10cm




                                   EUT
                     Adapter



                                                                                     80cm

                            80cm


         AC Line                         80cm


                                                              40cm
                     LISN                                                             LISN

                                                       40cm




Cerpass Technology Corp.                                             Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                                   Page No.      : 14 of 70
                                                                     FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                        Report No.: TEFI1901083


     5.4 Test Result and Data

            Power       :   AC 120V         Pol/Phase      :   LINE
            Test Mode   :   Mode 2          Temperature    :   22 °C
            Test date   :   Mar. 05, 2019   Humidity       :   52 %




Cerpass Technology Corp.                        Issued date    : May. 27, 2019
T-FD-509-0 Ver 1.0                              Page No.       : 15 of 70
                                                FCC ID.        : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                        Report No.: TEFI1901083



            Power       :   AC 120V         Pol/Phase      :   NEUTRAL
            Test Mode   :   Mode 2          Temperature    :   22 °C
            Test date   :   Mar. 05, 2019   Humidity       :   52 %




Cerpass Technology Corp.                        Issued date    : May. 27, 2019
T-FD-509-0 Ver 1.0                              Page No.       : 16 of 70
                                                FCC ID.        : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                                  Report No.: TEFI1901083

  6. Test of Radiated Spurious Emission
     6.1 Test Limit
           In any 100kHz bandwidth outside the frequency band in which the spread spectrum or
           digitally modulated intentional radiator is operating, the radio frequency power that is
           produced by the intentional radiator shall be at least 20dB below that in the 100kHz
           bandwidth within the band that contains the highest level of the desired power, based on
           either an RF conducted or a radiated measurement. If the transmitter measurement is
           based on the maximum conducted output power, the attenuation required under this
           paragraph shall be 30dB instead of 20dB. In addition, radiated emissions which fall in
           section 15.205(a) the restricted bands must also comply with the radiated emission limit
           specified in section 15.209(a).

                   Frequency              Field Strength         Measurement Distance
                      (MHz)              (microvolt/meter)             (meters)
                  0.009 ~ 0.490            2400/F(kHz)                   300
                  0.490 ~ 1.705            24000/F(kHz)                     30
                   1.705 ~ 30.0                  30                         30
                      30 ~ 88                   100                          3
                     88 ~ 216                   150                          3
                     216 ~ 960                  200                          3
                     Above 960                  500                          3


     6.2 Test Procedures
           a. The EUT was placed on a rotatable table top 0.8 meter above ground.
           b. The EUT was set 3 meters from the interference receiving antenna which was mounted on
                 the top of a variable height antenna tower.
           c.   The table was rotated 360 degrees to determine the position of the highest radiation.
           d.   The antenna is a broadband antenna and its height is varied between one meter and four
                 meters above ground to find the maximum value of the field strength both horizontal
                 polarization and vertical polarization of the antenna are set to make the measurement.
           e.   For each suspected emission the EUT was arranged to its worst case and then tune the
                 antenna tower (from 1 M to 4 M) and turn table (from 0 degree to 360 degrees) to find the
                 maximum reading.
           f.   Set the test-receiver system to Peak or CISPR quasi-peak Detect Function and specified
                 bandwidth with Maximum Hold Mode.
           g.   If the emission level of the EUT in peak mode was 3 dB lower than the limit specified, then
                 testing will be stopped and peak values of EUT will be reported, otherwise, the emissions
                 which do not have 3 dB margin will be repeated one by one using the quasi-peak method
                 and reported.
           h. For testing above 1GHz, the emission level of the EUT in peak mode was 20dB lower than
                average limit (that means the emission level in peak mode also complies with the limit in
                average mode), then testing will be stopped and peak values of EUT will be reported,
                otherwise, the emissions will be measured in average mode again and reported.
           i. “Cone of radiation” has been considered to be 3dB bandwidth of the measurement
                antenna.




Cerpass Technology Corp.                                                    Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                                          Page No.      : 18 of 70
                                                                            FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                        Report No.: TEFI1901083


     6.3 Typical Test Setup
           Below 30MHz test setup
                                  Antenna


                                                                    Equipment under Test


                                            *   3m


                            1m


                                                                                             0.8M
                                                                         Turn Table


                                                                              T

                                                                             bl
                                                     Ground Plane
              Receiver


          30MHz- 1GHz Test Setup
                                  Antenna


                                                                    Equipment under Test

                                            *   3m




                                                                                             0.8M
                                                                         Turn Table


                                                                              T

                                                                             bl
                                                     Ground Plane
              Receiver


          Above 1GHz Test Setup




                                                                                           1.5M




Cerpass Technology Corp.                                       Issued date        : May. 27, 2019
T-FD-509-0 Ver 1.0                                             Page No.           : 19 of 70
                                                               FCC ID.            : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                                            Report No.: TEFI1901083


     6.4 Test Result and Data (9KHz ~ 30MHz)
           The 9kHz - 30MHz spurious emission is under limit 20dB more.


     6.5 Test Result and Data (30MHz ~ 1GHz)

               Power        :   AC 120V                        Pol/Phase      :     VERTICAL
               Test Mode    :   Mode 2                         Temperature    :     23 °C
               Test Date    :   Feb. 19, 2019                  Humidity       :     61 %




Cerpass Technology Corp.                                              Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                                    Page No.      : 20 of 70
                                                                      FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                           Report No.: TEFI1901083




          Power       :   AC 120V         Pol/Phase     :   HORIZONTAL
          Test Mode   :   Mode 2          Temperature   :   23 °C
          Test Date   :   Feb. 19, 2019   Humidity      :   61 %




Cerpass Technology Corp.                            Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                  Page No.      : 21 of 70
                                                    FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                               Report No.: TEFI1901083


     6.6 Test Result and Data (1GHz ~ 25GHz)

            Power       :   AC 120V            Pol/Phase     :   VERTICAL
            Test Mode   :   Mode 1, CH01       Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019      Humidity      :   61 %




Cerpass Technology Corp.                                Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                      Page No.      : 22 of 70
                                                        FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                            Report No.: TEFI1901083




            Power       :   AC 120V         Pol/Phase     :   HORIZONTAL
            Test Mode   :   Mode 1, CH01    Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019   Humidity      :   61 %




Cerpass Technology Corp.                            Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                  Page No.      : 23 of 70
                                                    FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                            Report No.: TEFI1901083



            Power       :   AC 120V         Pol/Phase     :   VERTICAL
            Test Mode   :   Mode 1, CH06    Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019   Humidity      :   61 %




Cerpass Technology Corp.                            Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                  Page No.      : 24 of 70
                                                    FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                            Report No.: TEFI1901083




            Power       :   AC 120V         Pol/Phase     :   HORIZONTAL
            Test Mode   :   Mode 1, CH06    Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019   Humidity      :   61 %




Cerpass Technology Corp.                            Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                  Page No.      : 25 of 70
                                                    FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                            Report No.: TEFI1901083



            Power       :   AC 120V         Pol/Phase     :   VERTICAL
            Test Mode   :   Mode 1, CH11    Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019   Humidity      :   61 %




Cerpass Technology Corp.                            Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                  Page No.      : 26 of 70
                                                    FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                            Report No.: TEFI1901083




            Power       :   AC 120V         Pol/Phase     :   HORIZONTAL
            Test Mode   :   Mode 1, CH11    Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019   Humidity      :   61 %




Cerpass Technology Corp.                            Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                  Page No.      : 27 of 70
                                                    FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                            Report No.: TEFI1901083



            Power       :   AC 120V         Pol/Phase     :   VERTICAL
            Test Mode   :   Mode 2, CH01    Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019   Humidity      :   61 %




Cerpass Technology Corp.                            Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                  Page No.      : 28 of 70
                                                    FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                            Report No.: TEFI1901083




            Power       :   AC 120V         Pol/Phase     :   HORIZONTAL
            Test Mode   :   Mode 2, CH01    Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019   Humidity      :   61 %




Cerpass Technology Corp.                             Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                   Page No.      : 29 of 70
                                                     FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                            Report No.: TEFI1901083



            Power       :   AC 120V         Pol/Phase     :   VERTICAL
            Test Mode   :   Mode 2, CH06    Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019   Humidity      :   61 %




Cerpass Technology Corp.                            Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                  Page No.      : 30 of 70
                                                    FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                            Report No.: TEFI1901083




            Power       :   AC 120V         Pol/Phase     :   HORIZONTAL
            Test Mode   :   Mode 2, CH06    Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019   Humidity      :   61 %




Cerpass Technology Corp.                             Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                   Page No.      : 31 of 70
                                                     FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                            Report No.: TEFI1901083



            Power       :   AC 120V         Pol/Phase     :   VERTICAL
            Test Mode   :   Mode 2, CH11    Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019   Humidity      :   61 %




Cerpass Technology Corp.                             Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                   Page No.      : 32 of 70
                                                     FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                            Report No.: TEFI1901083




            Power       :   AC 120V         Pol/Phase     :   HORIZONTAL
            Test Mode   :   Mode 2, CH11    Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019   Humidity      :   61 %




Cerpass Technology Corp.                            Issued date   : May. 27, 2019
T-FD-509-0 Ver 1.0                                  Page No.      : 33 of 70
                                                    FCC ID.       : NDPM3A-2


          CERPASS TECHNOLOGY CORP.                            Report No.: TEFI1901083




            Power       :   AC 120V         Pol/Phase     :   VERTICAL
            Test Mode   :   Mode 3, CH01    Temperature   :   23 °C
            Test Date   :   Feb. 19. 2019   Humidity      :   61 %




Cerpass Technology Corp.                            Issued date   : May. 27, 2019