Report for internal antenna EUT

FCC ID: NDD9578221026

Test Report

Download: PDF
FCCID_1422242

FCC TEST REPORT                                                                           Report No. : FC110510




                     FCC EMC TEST REPORT
                                     CERTIFICATE
                                                 according to

                                  47 CFR FCC Part 15 Subpart B

                Equipment              : 300N Wireless LAN USB Adapter
                Model No.              : EW-7822GTN, GWU-H822GTn,
                                           EW-7722UTn V2, EW-7822UAN,
                                           GWU-H822UAn
                Brand Name             :   EDIMAX
                Filing Type            :   New Application
                Applicant              :   EDIMAX TECHNOLOGY CO., LTD.
                                           No.3, Wu Chuan 3rd Road, Wu-Ku Industrial
                                           Park, Taipei Hsien, Taiwan
                FCC ID                 :   NDD9578221026
                Manufacturer           :   EDIMAX TECHNOLOGY CO., LTD.
                                           No.3, Wu Chuan 3rd Road, Wu-Ku Industrial
                                           Park, Taipei Hsien, Taiwan
                Received Date    :         Oct. 14, 2010
                Final Test Date  :         Jan. 21, 2011
                Multiple Listing : Please refer to section 2.3


Statement
Test result included is only for the equipment with PIFA Antenna of the product.
The test result in this report refers exclusively to the presented test model / sample.
Without written approval of SPORTON International Inc., the test report shall not be reproduced except in full.
The measurements and test results shown in this test report were made in accordance with the procedures and
found in compliance with the limit given in ANSI C63.4-2003 and 47 CFR FCC Part 15 Subpart B.
The test equipment used to perform the test is calibrated and traceable to NML/ROC.




                                    SPORTON International Inc.
                      st
    No. 52 Hwa Ya 1 Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.

                                                                                            SPORTON International Inc.
                                                                                               Report Format Version: a


   FCC TEST REPORT                                                                                                                                          Report No. : FC110510



                                                                           Table of Contents
   CERTIFICATE OF COMPLIANCE ...............................................................................................................................1
   1 SUMMARY OF THE TEST RESULT .......................................................................................................................2
   2 GENERAL INFORMATION......................................................................................................................................3
       2.1      Product Details ................................................................................................................................................................................... 3
       2.2      Table for Test Modes .......................................................................................................................................................................... 3
       2.3      Table for Multiple Listing ..................................................................................................................................................................... 3
       2.4      Table for Testing Locations ................................................................................................................................................................. 3
       2.5      Table for Supporting Units .................................................................................................................................................................. 4
       2.6      EUT Operation during Test ................................................................................................................................................................. 4
       2.7      Test Configuration............................................................................................................................................................................... 5

   3 TEST RESULT .........................................................................................................................................................6
       3.1      AC Power Line Conducted Emissions Measurement .......................................................................................................................... 6
       3.2      Radiated Emissions Measurement .................................................................................................................................................... 10

   4 LIST OF MEASURING EQUIPMENTS ..................................................................................................................20
   5 TEST LOCATION ...................................................................................................................................................21
   6 NVLAP CERTIFICATE OF ACCREDITATION ......................................................................................................22
   APPENDIX A. TEST PHOTOS ........................................................................................................................ A1 ~ A5
   APPENDIX B. PHOTOGRAPHS OF EUT ....................................................................................................... B1 ~ B6




SPORTON International Inc.                                                                                                                                    Page No.              : i of ii
TEL : 886-2-2696-2468                                                                                                                                         Issued Date           : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                Report No. : FC110510



                                     History of This Test Report

          Original Issue Date: Jan. 28, 2011
          Report No.: FC110510

            Report No.                Issue Date   Description




                                                   Receiver Frequency

                                                   2412~2462MHz




                                                   30~88 40 88~216 43.5 216~960

                                                   5th harmonic of highest frequency.



                                                   46 Above 960 54 3




SPORTON International Inc.                                                         Page No.      : ii of ii
TEL : 886-2-2696-2468                                                              Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                   Report No. : FC110510




             CERTIFICATE OF COMPLIANCE
                     CERTIFICATE
                                                 according to

                                   47 CFR FCC Part 15 Subpart B

                    Equipment           : 300N Wireless LAN USB Adapter
                    Model No.           : EW-7822GTN, GWU-H822GTn,
                                          EW-7722UTn V2, EW-7822UAN,
                                          GWU-H822UAn
                    Brand Name          : EDIMAX
                    Applicant           : EDIMAX TECHNOLOGY CO., LTD.
                                          No.3, Wu Chuan 3rd Road, Wu-Ku Industrial Park,
                                          Taipei Hsien, Taiwan




      WE HEREBY CERTIFY THAT:
        The measurements shown in this test report were made in accordance with the procedures given in
        ANSI C63.4-2003 and the energy emitted by this equipment were passed 47 CFR FCC Part 15 Subpart B.
        Testing was carried out on Oct. 14, 2010 at SPORTON International Inc. LAB.




        ____________________________
        Wayne Hsu / Vice Manager
        Reviewed Data: Jul. 30, 2004




                                       SPORTON International Inc.
                             st
         No. 52 Hwa Ya 1 Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.




SPORTON International Inc.                                                            Page No.      : 1 of 22
TEL : 886-2-2696-2468                                                                 Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                            Report No. : FC110510


   1 SUMMARY OF THE TEST RESULT

                                  Applied Standard: 47 CFR FCC Part 15 Subpart B
         Part   Rule Section                   Description of Test                Result         Under Limit
         3.1    15.107         AC Power Line Conducted Emissions                 Complies         16.51 dB
         3.2    15.109         Radiated Emissions                                Complies          4.76 dB

                              Test Items                        Uncertainty            Remark
          AC Power Line Conducted Emissions                    ±2.3dB         Confidence levels of 95%
          Radiated Emissions                                   ±1.9dB         Confidence levels of 95%




SPORTON International Inc.                                                     Page No.      : 2 of 22
TEL : 886-2-2696-2468                                                          Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                        Report No. : FC110510


   2 GENERAL INFORMATION
   2.1 Product Details
          The RF detail of EUT is shown in this report. For more detailed features description, please refer to the
          manufacturer’s specifications or user’s manual.


   2.2 Table for Test Modes
          Investigation has been done on the entire possible Configuration for searching the worst cases. The
          following table is a list of the test modes shown in this test report.
                            Test Items                                            Mode
            AC Power Line Conducted Emissions             Normal Mode
            Radiated Emissions (30MHz~1GHz)               Normal Mode
            Radiated Emissions (Above 1GHz)               CRX 802.11g CH 6 / CRX 802.11n CH 6 (20MHz) /
                                                          CRX 802.11n CH 6 (40MHz)

   2.3 Table for Multiple Listing
          No.                Brand Name                                    Model Name
                                                              EW-7822GTN,GWU-H822GTn,EW-7722UTn V2,
           1                    Edimax
                                                                     EW-7822UAN,GWU-H822UAn
           2                     Belkin                                      F7D2102

   2.4 Table for Testing Locations
           Test Site No.   Site Category           Location
             CO04-HY        Conduction              Hwa Ya
            03CH02-HY           SAC                 Hwa Ya
          Semi Anechoic Chamber (SAC).




SPORTON International Inc.                                                                 Page No.      : 3 of 22
TEL : 886-2-2696-2468                                                                      Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                        Report No. : FC110510


   2.5 Table for Supporting Units
                  Support Unit              Brand             Model              FCC ID             Remark
                    Notebook                 DELL             E5500                DoC
                     Modem                  ACEEX            DM1414                DoC
                                                                                                   Conducted
                  (USB)Mouse               Microsoft           1004                DoC             Emissions
                   Wireless AP
                                            D-Link          DNS-G120               DoC
               (Remote workstation)
                    Notebook                 DELL             E5500                DoC
                                                                                                    Radiated
                     Modem                  ACEEX            DM1414                DoC
                                                                                                    Emissions
                  (USB)Mouse               Microsoft           1004                DoC

   2.6 EUT Operation during Test
          An executive program, “EMCTEST.EXE” under WIN XP, which generates a complete line of
          continuously repeating “H“ pattern was used as the test software.
          The program was executed as follows :
          a. Turn on the power of all equipment.
          b. The NB reads the test program from the hard disk drive and runs it.
          c. The NB sends "H" messages to the monitor, and the monitor displays "H" patterns on the screen.
          d. The NB sends "H" messages to the modem.
          e. The NB sends "H" messages to the internal hard disk, and the hard disk reads and writes the message.
          f.     Repeat the steps from c to e.


          At the same time, the following programs were executed:
          - Executed " Realtek 11n single chip 9xC USB WLAN NIC " to the internal hard disk, and the hard disk
           reads and writes the message.
          - Executed "ping.exe" to link with the remote workstation to receive and transmit data by wireless.




SPORTON International Inc.                                                                Page No.      : 4 of 22
TEL : 886-2-2696-2468                                                                     Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                                      Report No. : FC110510


   2.7 Test Configuration
          Radiation Emissions Test Configuration
                                                                                                       AC Main
                                                      3
                                          AC Main



                                                                VGA




                                                                                                         Adapter
                                                                                     DC
                                                                RS232                USB x 2
                                              Modem
                                                                RJ-45     Notebook

                                                                USB x 2

                                                                                                               1
                                                          EUT




                                                                                               2




             1. DC power line, 1.5m, Non-Shielded.
             2. USB cable, 1.8m, Braided-Shielded.
             3. RS-232, 1.5m, Braided-Shielded.
                                                                                               Mouse




SPORTON International Inc.                                                                               Page No.      : 5 of 22
TEL : 886-2-2696-2468                                                                                    Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                      Report No. : FC110510


   3 TEST RESULT
   3.1 AC Power Line Conducted Emissions Measurement
   3.1.1 Limit
          For this product which is designed to be connected to the AC power line, the radio frequency voltage
          that is conducted back onto the AC power line on any frequency or frequencies within the band 150
          kHz to 30 MHz shall not exceed below limits table.
          Class B
                    Frequency (MHz)                    QP Limit (dBuV)                   AV Limit (dBuV)
                        0.15~0.5                             66~56                             56~46
                          0.5~5                                56                                46
                          5~30                                 60                                50

   3.1.2 Measuring Instruments and Setting
          Please refer to section 4 of equipments list in this report. The following table is the setting of the
          receiver.
            Receiver Parameters       Setting
            Attenuation               10 dB
            Start Frequency           0.15 MHz
            Stop Frequency            30 MHz
            IF Bandwidth              9 KHz

   3.1.3 Test Procedures
          1.    The EUT warm up about 15 minutes then start test.
          2.    The EUT or host of EUT has to be placed 0.4 meter far from the conducting wall of the shielding
                room and at least 80 centimeters from any other grounded conducting surface.
          3.    Connect EUT or host of EUT to the power mains through a line impedance stabilization network
                (LISN).
          4.    All the support units are connected to the other LISNs. The LISN should provide 50uH/50ohms
                coupling impedance.
          5.    The frequency range from 150 KHz to 30 MHz was searched.
          6.    Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum
                Hold Mode.
          7.    The measurement has to be done between each power line and ground at the power terminal.




SPORTON International Inc.                                                               Page No.      : 6 of 22
TEL : 886-2-2696-2468                                                                    Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                     Report No. : FC110510


   3.1.4 Test Setup Layout




            LEGEND:
            (1) Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and
            forth in the center forming a bundle 30 to 40 cm long.
            (2) I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
            cable may be terminated, if required, using the correct terminating impedance. The overall length
            shall not exceed 1 m.
            (3) EUT connected to one LISN. Unused LISN measuring port connectors shall be terminated in 50 Ω.
            LISN can be placed on top of, or immediately beneath, reference ground plane.
            (3.1) All other equipment powered from additional LISN(s).
            (3.2) Multiple outlet strip can be used for multiple power cords of non-EUT equipment.
            (3.3) LISN at least 80 cm from nearest part of EUT chassis.
            (4) Cables of hand-operated devices, such as keyboards, mice, etc., shall be placed as for normal
            use.
            (5) Non-EUT components of EUT system being tested.
            (6) Rear of EUT, including peripherals, shall all be aligned and flush with rear of tabletop.
            (7) Rear of tabletop shall be 40 cm removed from a vertical conducting plane that is bonded to the
            ground plane.

   3.1.5 Test Deviation
          There is no deviation with the original standard.

   3.1.6 EUT Operation during Test
          The EUT was placed on the test table and programmed in normal function.


SPORTON International Inc.                                                              Page No.      : 7 of 22
TEL : 886-2-2696-2468                                                                   Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


  Fco Test RePonT                                                               Heport No. : EGr10510

  3.1.7 Results of AC Power Line Conducted Emissions Measurement
          Finai Test Bate      yan. 21, 2011             Test Sie No:        coomry
          Temperature          225                       Humaity             seov
          Test Engineer        Jason                     Gontiquration       Nornal Mose
         Line
                 so tevelasan)                                                             one: rorore:


                                                                                        ciommensvects
                              L.                                                    cismmensueoss      av

                   w

                                                                                              1



                   0 cases           as        i         2               s          o              mm
                                                   Freqvency titl)




                                  Over tisis maa ursn. canie
                      Freq bever Ainis Line. lever Pacton lore menare
                       n ~avf s aw aw s oa
           1.   o.soreeso. anas cancon enuas aries ocoe o.t0 on
           2    o aoreeso suleo ~arces sauts mrler 0.00 0.20 Average
           3    o.arenizo assoe ~anlsnl secar mnure oc09 o0 op
           4    ocarenizo ascoe ~ancon anlar anine 0109 0.01 Average
           s    olsissuzo arlos ancor selcn 2o.00 octo o.63 oo
           6.   olsussazo selee —onl06. 4600 24.8%...0.30 0.09 Average
           1    o.summuz. anlae —osse secco mrise on 0.00 oo
           s    o.sassuzo sn e z684. 4600 29026 Oc42.0.09 Average
           s‘      s0.900 as se zes colce sulre ocze oine on
          10       solsco ascer cz0.se no.co 2s.20 0.20.. o.id Average
          in       dearo anze cssure eo.co seire oise o.or
          12       resio mrior czeu99 so.00. 20.3 0.34 0.94 Average




SFOTONmtematoratine:                                                             Fwane            —sue
Te so2asoszce                                                                    IssuedDate       Jon 28. z0
rax. ceszzsosems


   FCC TEST REPORT                                           Report No. : FC110510


            Neutral




            Note:
            Level = Read Level + LISN Factor + Cable Loss.




SPORTON International Inc.                                   Page No.      : 9 of 22
TEL : 886-2-2696-2468                                        Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                         Report No. : FC110510


   3.2 Radiated Emissions Measurement
   3.2.1 Limit
          Measurements shall be made with a quasi-peak measuring receiver in the frequency range 30 MHz to
          5th harmonic of highest frequency. The quasi-peak measuring receiver shall be in accordance with
          clause 2 of CISPR 16-1. Receivers with peak detectors shall be in accordance with clause 3 of CISPR
          16-1, and shall have a 6 dB bandwidth in accordance with clause 2 of CISPR 16-1.
                     Frequency of Emission (MHz)                    Field Strength QP Limit (dBuV/m) at 3m
                                  30~88                                                40
                                 88~216                                               43.5
                                 216~960                                               46

   3.2.2 Measuring Instruments and Setting
          Please refer to section 4 of equipments list in this report. The following table is the setting of spectrum
          analyzer and receiver.
            Receiver Parameter                           Setting
            Attenuation                                  Auto
            Start ~ Stop Frequency                       30MHz~1000MHz / RB 120kHz for QP

               Spectrum Parameter                        Setting
               Start Frequency                           1000 MHz
               Stop Frequency                            5th harmonic of highest frequency
               RB / VB                                   1 MHz / 1MHz for Peak; 1 MHz / 10Hz for Average


   3.2.3 Test Procedures
          1.     The EUT was placed on the top of the turntable 0.8 meter above ground. The phase center of the
                 receiving antenna mounted on the top of a height-variable antenna tower was placed 3 meters far
                 away from the turntable.
          2.     Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to
                 determine the position of the highest radiation.
          3.     The height of the broadband receiving antenna was varied between one meter and four meters
                 above ground to find the maximum emissions field strength of both horizontal and vertical
                 polarization.
          4.     For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the
                 turntable was rotated (from 0 degree to 360 degrees) to find the maximum reading.
          5.     Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified
                 bandwidth under Maximum Hold Mode.




SPORTON International Inc.                                                                  Page No.      : 10 of 22
TEL : 886-2-2696-2468                                                                       Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                 Report No. : FC110510


   3.2.4 Test Setup Layout




                                                              3m




   3.2.5 Test Deviation
          There is no deviation with the original standard.




SPORTON International Inc.                                         Page No.      : 11 of 22
TEL : 886-2-2696-2468                                              Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


  Fco Test RePonT                                                                               Heport No. : EGr10510

  32. Results of Radlated Emissions (30MHz~1GHz)
          Finai Test Bate Oc 14, 2010                               Test Site ho.           sschozny
          Temperature      2re                                      Humiity                 sn
          Test Engineer    Cns                                      Goniquration            NomiMose
         Honzantel
                 .Levetoouim                                                                         peeczemncs
                                                                                                      ree use



                           —'3—5‘7
                       o4




                | ‘          |
                *5                    ze                  ns                    on                  we.              ow
                                                               Frequeney uts




                                      Over.   Linit     readiatema.    Cabte    Preanp
                   Preq.   tevet.    kinit     line:   Level. Hactor    toae    Yactor   Renack
                    c      aun           —a   nam       aw am              a~       a
           a     ecaee     snn       cner     anon     srge ces         aar      riire   reak
           20   ars.oes    ons      cancce    ancse    anler anas       altz     27053   Peak
           3    esn        anse      cecte    acon     sis anerl        2isn     2ei9s   reak
           a    smisse     anas      cnlen    aclen    anoe mmz         acte     onar    reak
           s    asnare.    aner      celas    accon    ancs ancer       ale      Piies   Peak
           6    melase     aner      ces      aclon    anlee recrrl     alns     riom    beak




SFOmrONmtematoratie.                                                                              Farns        rrom
Te soc2zsosz0e                                                                                    IssuedDate   Jon 28. z0
rax. ceszzsosems


   FCC TEST REPORT                                                                  Report No. : FC110510


            Vertical




            Note:
            The amplitude of spurious emissions that are attenuated by more than 20dB below the permissible
            value has no need to be reported.
            Emission level (dBuV/m) = 20 log Emission level (uV/m).
            Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.




SPORTON International Inc.                                                           Page No.      : 13 of 22
TEL : 886-2-2696-2468                                                                Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


  Fco Test RePonT                                                                      Heport No. : EGr10510

  3,2.7 Results for Radlated Emissions (1GHz~Sth harmonic of highest frequency}
          Finai Test Bate Jan 05. 2om                              Test Site ho.     sschozny
          Temperature       2re                                    Humiity           sn
          Test Engineer     Cns                                    Goniquration      cox 502 t1g on 5
         Honzantel
                 . Levetoouim                                                                  pae:zencsas




                 a




                     wooe            Sim                  Eo            F.                  Toom:            Toow
                                                            Frequeny uts




                                      Ovex.   kinit      tesdtatema. Cabte Prearp
                    Preq.   tevet.   kinit      Line:   Level. Ractor Loas Factor Remack
                     c      aun          ~a   num        aw am           a~    a
           1.   aemees      sear     cnsr      sen      snar enas aler micts reak
           2    asesoos     anse     css       silom    siire mss 239 docte Peak
           3    reerloos    anes     ceon      silee    anar azcce sz ors reak




SFOmrONmtematoratie.                                                                       Farns        mm
Te soc2zsosz0e                                                                             IssuedDate   Jon 28. z0
rax. ceszzsosems


   FCC TEST REPORT                                                                  Report No. : FC110510


            Vertical




            Note:
            The amplitude of spurious emissions that are attenuated by more than 20dB below the permissible
            value has no need to be reported.
            Emission level (dBuV/m) = 20 log Emission level (uV/m).
            Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.




SPORTON International Inc.                                                           Page No.      : 15 of 22
TEL : 886-2-2696-2468                                                                Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


  Fco Test RePonT                                                            Heport No. : EGr10510


          Finai Test bate Jan. 05. 20m                 Test Site ho.     sschozny
          Temperature      2re                         Humiity           s%
          Test Engineer    Cns                         Gonfiquration     Crx 502 tim on o Govng)
         Honzantel
                 .tevetoonim                                                            paeczoncores




                                                                                ree cuass n avam




                  wove         sam             son.             wn.             Toom:            Toowe
                                                   Frequency uts




                                 Over. kinit tesdtatemsa. Cabte Prearp
                   Peeq. tevet. Linit Line: Level. Ractor Loss Factor Renack

           1.   ameaes sese cnas siee aoian mees           ns 9093 Peak
           20   anmloes asles chon silem arise anae        olsz ts Peak
           3    smirloos anar color selon ancee. ances     dlee oalse Reak




SFOmrONmtematoratie.                                                           Farns        rua
Te soc2zsosz0e                                                                 IssuedDate   Jon 28. z0
rax. ceszzsosems


   FCC TEST REPORT                                                                  Report No. : FC110510


            Vertical




            Note:
            The amplitude of spurious emissions that are attenuated by more than 20dB below the permissible
            value has no need to be reported.
            Emission level (dBuV/m) = 20 log Emission level (uV/m).
            Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.




SPORTON International Inc.                                                           Page No.      : 17 of 22
TEL : 886-2-2696-2468                                                                Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


  Fco Test Repont                                                                  Heport No: Ecrtosta

          Finai Test bate        Oc. 14, 2010              Test Site ho.       sschozny
          Temperature            2re                       Humiity             s%
          Test Engineer          Cns                       Gonfiquration       crx 502 Tim on o omg)
         Honzantel
                   ar Lovet atovim                                                            paeczemcens




                   al   o       x—




                    "rom             T:            Sien.            w.                To:              Toom
                                                        Frequency ty




                                      Over Linit resitatema. Cabte Preary
                     Freq.    tevet. kinit bine: evel. Hactor tone ¥actor   Renack
                      ic     auh ~a aum aw am a~ a
           1    mss          sese cnar siee sian enae nier onleo            reak
           20   masloes      soar colst se anlen arian alee ie              rear
           a     ausnloss    asles calonl selen arar anas alne ailse        Pear




Sromonmemateraiie.                                                                   Fams         —mug
Te soc2zsosz0e                                                                       IssuedDate   Jon 28. z0
rax. ceszzsosems


   FCC TEST REPORT                                                                  Report No. : FC110510


            Vertical




            Note:
            The amplitude of spurious emissions that are attenuated by more than 20dB below the permissible
            value has no need to be reported.
            Emission level (dBuV/m) = 20 log Emission level (uV/m).
            Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.




SPORTON International Inc.                                                           Page No.      : 19 of 22
TEL : 886-2-2696-2468                                                                Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                            Report No. : FC110510


   4 LIST OF MEASURING EQUIPMENTS
                                                                                              Calibration
            Instrument       Manufacturer    Model No.     Serial No.    Characteristics                           Remark
                                                                                                 Date
                                                                                                                  Conduction
           EMC Receiver          R&S          ESCS 30       100174       9kHz – 2.75GHz       Apr. 06, 2010
                                                                                                                  (CO04-HY)
                                                                                                                  Conduction
               LISN            MessTec       NNB-2/16Z       99041       9kHz – 30MHz         Mar. 23, 2010
                                                                                                                  (CO04-HY)
               LISN                                                                                               Conduction
                                EMCO         3810/2NM      9703-1839     9kHz – 30MHz         Apr. 29, 2010
           (Support Unit)                                                                                         (CO04-HY)
                                                                                                                  Conduction
          RF Cable-CON         UTIFLEX      3102-26886-4    CB049        9kHz – 30MHz         Apr. 20, 2010
                                                                                                                  (CO04-HY)
                                                                                                                  Conduction
             EMI Filter       LINDGREN       LRE-2030        2651              < 450 Hz           N/A
                                                                                                                  (CO04-HY)
       Note: Calibration Interval of instruments listed above is one year.

                                                                                               Calibration
            Instrument       Manufacturer    Model No.     Serial No.    Characteristics                           Remark
                                                                                                  Date
             Spectrum                                                                                              Radiation
                                 R&S           FSP40       100305/040        9 kHz - 40GHz    Feb. 02, 2010
             Analyzer                                                                                            (03CH02-HY)
         3m Semi Anechoic        SIDT                                    30 MHz - 1 GHz                            Radiation
                                              SAC-3M       03CH02-HY                          May 01, 2010
             Chamber          FRANKONIA                                       3m                                 (03CH02-HY)
                                                                                                                   Radiation
             Amplifier          Agilent        8447D       2944A11146   100 kHz – 1.3 GHz     Jul. 23, 2010
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
             Amplifier          Agilent        8449B       3008A02373    1GHz – 26.5 GHz      Jul. 23, 2010
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
           Horn Antenna      ETS-LINDGREN       3117        00091920         1GHz~18GHz       Nov. 11, 2010
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
          RF Cable-R03m         Jye Bao        RG142         CB021       30MHz ~ 1GHz         Feb. 26, 2010
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
          RF Cable-HIGH        SUHNER       SUCOFLEX106    03CH02-HY         1GHz~40GHz       Feb. 26, 2010
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
           Bilog Antenna      SCHAFFNER       CBL61128        2723       30 MHz - 2 GHz       Oct. 16, 2010
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
            Turn Table            HD           DS 420      420/649/00        0 - 360 degree        N/A
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
           Antenna Mast           HD           MA 240      240/559/00          1m-4m               N/A
                                                                                                                 (03CH02-HY)
       Note: Calibration Interval of instruments listed above is one year.

                                                                                               Calibration
            Instrument       Manufacturer    Model No.     Serial No.    Characteristics                           Remark
                                                                                                  Date
                                                                                                                   Radiation
           Loop Antenna          R&S          HFH2-Z2      860004/001    9 kHz - 30 MHz       Jul. 29, 2010*
                                                                                                                 (03CH02-HY)
       Note: Calibration Interval of instruments listed above is two year.




SPORTON International Inc.                                                                    Page No.         : 20 of 22
TEL : 886-2-2696-2468                                                                         Issued Date      : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                                 Report No. : FC110510


   5 TEST LOCATION
          SHIJR        ADD   :   6Fl., No. 106, Sec. 1, Shintai 5th Rd., Shijr City, Taipei, Taiwan 221, R.O.C.
                       TEL   :   886-2-2696-2468
                       FAX   :   886-2-2696-2255
          HWA YA       ADD   :   No. 52, Hwa Ya 1st Rd., Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.
                       TEL   :   886-3-327-3456
                       FAX   :   886-3-318-0055
          LINKOU       ADD   :   No. 30-2, Dingfu Tsuen, Linkou Shiang, Taipei, Taiwan 244, R.O.C
                       TEL   :   886-2-2601-1640
                       FAX   :   886-2-2601-1695
          DUNGHU       ADD   :   No. 3, Lane 238, Kangle St., Neihu Chiu, Taipei, Taiwan 114, R.O.C.
                       TEL   :   886-2-2631-4739
                       FAX   :   886-2-2631-9740
          JUNGHE       ADD   :   7Fl., No. 758, Jungjeng Rd., Junghe City, Taipei, Taiwan 235, R.O.C.
                       TEL   :   886-2-8227-2020
                       FAX   :   886-2-8227-2626
                                                            nd
          NEIHU        ADD   :   4Fl., No. 339, Hsin Hu 2        Rd., Taipei 114, Taiwan, R.O.C.
                       TEL   :   886-2-2794-8886
                       FAX   :   886-2-2794-9777
          JHUBEI       ADD   :   No.8, Lane 724, Bo-ai St., Jhubei City, HsinChu County 302, Taiwan, R.O.C.
                       TEL   :   886-3-656-9065
                       FAX   :   886-3-656-9085




SPORTON International Inc.                                                                         Page No.       : 21 of 22
TEL : 886-2-2696-2468                                                                              Issued Date    : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                        Report No. : FC110510


   6 NVLAP CERTIFICATE OF ACCREDITATION




SPORTON International Inc.                Page No.      : 22 of 22
TEL : 886-2-2696-2468                     Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255



Document Created: 2011-02-16 16:27:55
Document Modified: 2011-02-16 16:27:55

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC