FCC TEST REPORT                                                                           Report No. : FC110510




                       FCC EMC TEST REPORT
                                     CERTIFICATE
                                                 according to

                                  47 CFR FCC Part 15 Subpart B

                  Equipment              : 300N Wireless LAN USB Adapter
                  Model No.              : EW-7822GTN, GWU-H822GTn,
                                             EW-7722UTn V2, EW-7822UAN,
                                             GWU-H822UAn
                  Brand Name             :   EDIMAX
                  Filing Type            :   New Application
                  Applicant              :   EDIMAX TECHNOLOGY CO., LTD.
                                             No.3, Wu Chuan 3rd Road, Wu-Ku
                                             Industrial Park, Taipei Hsien, Taiwan
                  FCC ID                 :   NDD9578221026
                  Manufacturer           :   EDIMAX TECHNOLOGY CO., LTD.
                                             No.3, Wu Chuan 3rd Road, Wu-Ku
                                             Industrial Park, Taipei Hsien, Taiwan
                  Received Date    :         Dec. 27, 2010
                  Final Test Date  :         Jan. 21, 2011
                  Multiple Listing : Please refer to section 2.3


Statement
Test result included is only for the equipment with Dipole Antenna of the product.
The test result in this report refers exclusively to the presented test model / sample.
Without written approval of SPORTON International Inc., the test report shall not be reproduced except in full.
The measurements and test results shown in this test report were made in accordance with the procedures and
found in compliance with the limit given in ANSI C63.4-2003 and 47 CFR FCC Part 15 Subpart B.
The test equipment used to perform the test is calibrated and traceable to NML/ROC.




                                    SPORTON International Inc.
                      st
    No. 52 Hwa Ya 1 Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.

                                                                                            SPORTON International Inc.
                                                                                               Report Format Version: a


   FCC TEST REPORT                                                                                                                                          Report No. : FC110510



                                                                           Table of Contents
   CERTIFICATE OF COMPLIANCE ...............................................................................................................................1
   1 SUMMARY OF THE TEST RESULT .......................................................................................................................2
   2 GENERAL INFORMATION......................................................................................................................................3
       2.1      Product Details ................................................................................................................................................................................... 3
       2.2      Table for Test Modes .......................................................................................................................................................................... 3
       2.3      Table for Multiple Listing ..................................................................................................................................................................... 3
       2.4      Table for Testing Locations ................................................................................................................................................................. 3
       2.5      Table for Supporting Units .................................................................................................................................................................. 4
       2.6      EUT Operation during Test ................................................................................................................................................................. 4
       2.7      Test Configuration............................................................................................................................................................................... 5

   3 TEST RESULT .........................................................................................................................................................6
       3.1      AC Power Line Conducted Emissions Measurement .......................................................................................................................... 6
       3.2      Radiated Emissions Measurement .................................................................................................................................................... 10

   4 LIST OF MEASURING EQUIPMENTS ..................................................................................................................20
   5 TEST LOCATION ...................................................................................................................................................21
   6 NVLAP CERTIFICATE OF ACCREDITATION ......................................................................................................22
   APPENDIX A. TEST PHOTOS ........................................................................................................................ A1 ~ A5
   APPENDIX B. PHOTOGRAPHS OF EUT ....................................................................................................... B1 ~ B6




SPORTON International Inc.                                                                                                                                    Page No.              : i of ii
TEL : 886-2-2696-2468                                                                                                                                         Issued Date           : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                Report No. : FC110510



                                     History of This Test Report

          Original Issue Date: Jan. 28, 2011
          Report No.: FC110510

            Report No.                Issue Date   Description




                                                   Receiver Frequency

                                                   2412~2462MHz




                                                   30~88 40 88~216 43.5 216~960

                                                   5th harmonic of highest frequency.



                                                   46 Above 960 54 3




SPORTON International Inc.                                                         Page No.      : ii of ii
TEL : 886-2-2696-2468                                                              Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                   Report No. : FC110510




             CERTIFICATE OF COMPLIANCE
                     CERTIFICATE
                                                 according to

                                   47 CFR FCC Part 15 Subpart B

                    Equipment           : 300N Wireless LAN USB Adapter
                    Model No.           : EW-7822GTN, GWU-H822GTn,
                                          EW-7722UTn V2, EW-7822UAN,
                                          GWU-H822UAn
                    Brand Name          : EDIMAX
                    Applicant           : EDIMAX TECHNOLOGY CO., LTD.
                                          No.3, Wu Chuan 3rd Road, Wu-Ku Industrial Park,
                                          Taipei Hsien, Taiwan




      WE HEREBY CERTIFY THAT:
        The measurements shown in this test report were made in accordance with the procedures given in
        ANSI C63.4-2003 and the energy emitted by this equipment were passed 47 CFR FCC Part 15 Subpart B.
        Testing was carried out on Dec. 27, 2010 at SPORTON International Inc. LAB.




        ____________________________
        Wayne Hsu / Vice Manager
        Reviewed Data: Jul. 30, 2004




                                       SPORTON International Inc.
                             st
         No. 52 Hwa Ya 1 Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.




SPORTON International Inc.                                                            Page No.      : 1 of 22
TEL : 886-2-2696-2468                                                                 Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                            Report No. : FC110510


   1 SUMMARY OF THE TEST RESULT

                                  Applied Standard: 47 CFR FCC Part 15 Subpart B
         Part   Rule Section                   Description of Test                Result         Under Limit
         3.1    15.107         AC Power Line Conducted Emissions                 Complies         18.69 dB
         3.2    15.109         Radiated Emissions                                Complies          3.52 dB

                              Test Items                        Uncertainty            Remark
          AC Power Line Conducted Emissions                    ±2.3dB         Confidence levels of 95%
          Radiated Emissions                                   ±1.9dB         Confidence levels of 95%




SPORTON International Inc.                                                     Page No.      : 2 of 22
TEL : 886-2-2696-2468                                                          Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                        Report No. : FC110510


   2 GENERAL INFORMATION
   2.1 Product Details
          The RF detail of EUT is shown in this report. For more detailed features description, please refer to the
          manufacturer’s specifications or user’s manual.


   2.2 Table for Test Modes
          Investigation has been done on the entire possible Configuration for searching the worst cases. The
          following table is a list of the test modes shown in this test report.
                            Test Items                                            Mode
            AC Power Line Conducted Emissions             Normal Mode
            Radiated Emissions (30MHz~1GHz)               Normal Mode
            Radiated Emissions (Above 1GHz)               CRX 802.11g CH 6 / CRX 802.11n CH 6 (20MHz) /
                                                          CRX 802.11n CH 6 (40MHz)

   2.3 Table for Multiple Listing
          No.                Brand Name                                    Model Name
                                                              EW-7822GTN,GWU-H822GTn,EW-7722UTn V2,
           1                    Edimax
                                                                     EW-7822UAN,GWU-H822UAn
           2                     Belkin                                      F7D2102

   2.4 Table for Testing Locations
           Test Site No.   Site Category           Location
             CO04-HY        Conduction              Hwa Ya
            03CH02-HY           SAC                 Hwa Ya
          Semi Anechoic Chamber (SAC).




SPORTON International Inc.                                                                 Page No.      : 3 of 22
TEL : 886-2-2696-2468                                                                      Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                        Report No. : FC110510


   2.5 Table for Supporting Units
                  Support Unit              Brand             Model              FCC ID             Remark
                    Notebook                 DELL             E5500                DoC
                     Modem                  ACEEX            DM1414                DoC
                                                                                                   Conducted
                  (USB)Mouse               Microsoft           1004                DoC             Emissions
                   Wireless AP
                                            D-Link          DNS-G120               DoC
               (Remote workstation)
                    Notebook                 DELL             E5500                DoC
                                                                                                    Radiated
                     Modem                  ACEEX            DM1414                DoC
                                                                                                    Emissions
                  (USB)Mouse               Microsoft           1004                DoC

   2.6 EUT Operation during Test
          An executive program, “EMCTEST.EXE” under WIN XP, which generates a complete line of
          continuously repeating “H“ pattern was used as the test software.
          The program was executed as follows :
          a. Turn on the power of all equipment.
          b. The NB reads the test program from the hard disk drive and runs it.
          c. The NB sends "H" messages to the monitor, and the monitor displays "H" patterns on the screen.
          d. The NB sends "H" messages to the modem.
          e. The NB sends "H" messages to the internal hard disk, and the hard disk reads and writes the message.
          f.     Repeat the steps from c to e.


          At the same time, the following programs were executed:
          - Executed " Realtek 11n single chip 9xC USB WLAN NIC " to the internal hard disk, and the hard disk
           reads and writes the message.
          - Executed "ping.exe" to link with the remote workstation to receive and transmit data by wireless.




SPORTON International Inc.                                                                Page No.      : 4 of 22
TEL : 886-2-2696-2468                                                                     Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                                         Report No. : FC110510


   2.7 Test Configuration
          Radiation Emissions Test Configuration
                                                                                                          AC Main
                                                      3
                                          AC Main



                                                                   VGA




                                                                                                            Adapter
                                                                                        DC
                                                          Dipole   RS232                USB x 2
                                              Modem        Ant.
                                                                   RJ-45     Notebook

                                                                   USB x 2

                                                                                                                  1
                                                          EUT




                                                                                                  2




             1. DC power line, 1.5m, Non-Shielded.
             2. USB cable, 1.8m, Braided-Shielded.
             3. RS-232, 1.5m, Braided-Shielded.
                                                                                                  Mouse




SPORTON International Inc.                                                                                  Page No.      : 5 of 22
TEL : 886-2-2696-2468                                                                                       Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                      Report No. : FC110510


   3 TEST RESULT
   3.1 AC Power Line Conducted Emissions Measurement
   3.1.1 Limit
          For this product which is designed to be connected to the AC power line, the radio frequency voltage
          that is conducted back onto the AC power line on any frequency or frequencies within the band 150
          kHz to 30 MHz shall not exceed below limits table.
          Class B
                    Frequency (MHz)                    QP Limit (dBuV)                   AV Limit (dBuV)
                        0.15~0.5                             66~56                             56~46
                          0.5~5                                56                                46
                          5~30                                 60                                50

   3.1.2 Measuring Instruments and Setting
          Please refer to section 4 of equipments list in this report. The following table is the setting of the
          receiver.
            Receiver Parameters       Setting
            Attenuation               10 dB
            Start Frequency           0.15 MHz
            Stop Frequency            30 MHz
            IF Bandwidth              9 KHz

   3.1.3 Test Procedures
          1.    The EUT warm up about 15 minutes then start test.
          2.    The EUT or host of EUT has to be placed 0.4 meter far from the conducting wall of the shielding
                room and at least 80 centimeters from any other grounded conducting surface.
          3.    Connect EUT or host of EUT to the power mains through a line impedance stabilization network
                (LISN).
          4.    All the support units are connected to the other LISNs. The LISN should provide 50uH/50ohms
                coupling impedance.
          5.    The frequency range from 150 KHz to 30 MHz was searched.
          6.    Set the test-receiver system to Peak Detect Function and Specified Bandwidth with Maximum
                Hold Mode.
          7.    The measurement has to be done between each power line and ground at the power terminal.




SPORTON International Inc.                                                               Page No.      : 6 of 22
TEL : 886-2-2696-2468                                                                    Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


 Foo Test hePont                                                                  Report No. : FCrtos10


 3.1.4 Test Setup Layout

                                                                              Hon.condtuctveTable
                                                                              f5xtm




                                                                  ,L Contueting GroundPlane
                                                                     Extndts At Leaet .50
                                                                     Bevond EUSystemFaotprint


                                   Bonded To GroundPlane:
        Leceno
        (1) Interconnecting cables that hang closer than 40 im t the ground plane shall be folded back and
        forth in the centerforning a buncle 30 to 40 crn long
        (2) 1 cables tnat are not connected to a peripneralshall be bunded in the center. The end of the
        catle may be terminated, f required, using the comect terminating impedance, The overall length
        shall not exceed 1 m
        (3) EUT commectes to one LISN. Unused WISN measurng port comnectors shallbe terminates in 50 0
        LISN can be placed on top of,orImmedately beneath, reference ground plane
        (3.1) Allother equipment powered from addtonal LISN($)
        (3.2) Multgle outetstrp can be used for muliple power cords of non—EUT equlpment
        (3.) LISN atleast 80om from nearest part of EUT chassis
        (d) Cables of hand—operated devices, such as keyBoards, mice, etc., shall be placed as for normal
        use
        (6) Non—EUT components of EUT system being tested
        (6) Rear of EUT, inclueing pergnerals, shall al be algned and fush with ear oftabletop
        (7) Rearot tabletop shallbe 40 em removed from a vertical conducting plane that is bonded to the
        ground plane
 3.1.5 Test Deviation
      There is no deviaton win the ongnal standard

 3.1.8 EUT Operation during Test
      The EUT was placed on the testtable and programmex in normal functin



WFORbTmemateraie.                                                                  Farns         um
Te iss 2asosarce                                                                   Issied Date   Jon 28. 2001
mc sonnassarss


  Fco Test RePonT                                                               Heport No. : EGr10510

  3.1.7 Results of AC Power Line Conducted Emissions Measurement
          Finai Test Bate yan. 21, 2011                  Test Sie No:        coomry
          Temperature     2ase                           Humdity             seov
          Test Engineer   vason                          Gontiquration       Normal mose
         Line
                 Lereicem                                                                  oae: rorores


                                                                                        cismmensvects
                                                                                    Eismmensveoss av




                    eases            as        i          2              s          m           ®       &
                                                    trequency ut




                                    Over timit mss irme cane
                     Froq   level Linit Line. level. Pactor Loss Renark
                      in     an       a aw aw            a    oa
           1    o.asssore                exuse arces o.oe o.or on
           2.   o assoro                 stise. solen 0200 0.07 average
           3.   ocszsisro                sousr meler ocos o.on ar
           a    ocszsisre                ancsr anlor oc09 0l03 average
           s    ocssrsizo                secco 20.72. o0 oo« op
           6.   ocssmsuso                4600 he.3r 9130 0.08 average
           10      so—re0                €o.00 sucar ocze ocan or
           s       secreo                so.00 2o.2s oc20 Ol24 wverage
           s       iesz0                 eo.00 Relse o me ocne op
          10       resso    recre czscze so.co, 2o.20 034. 0.24 Average
          in       Rmeso    meaorcaslse eolco 2e es ol on on
          u2       brleso   secss orlos so.co se.so B4 oo Average




SFOmrONmtematoratie.                                                             Fasue        —sur
Te soc2zsosz0e                                                                   IssuedDate   Jon 28. z0
rax. ceszzsosems


   FCC TEST REPORT                                           Report No. : FC110510


            Neutral




            Note:
            Level = Read Level + LISN Factor + Cable Loss.




SPORTON International Inc.                                   Page No.      : 9 of 22
TEL : 886-2-2696-2468                                        Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                         Report No. : FC110510


   3.2 Radiated Emissions Measurement
   3.2.1 Limit
          Measurements shall be made with a quasi-peak measuring receiver in the frequency range 30 MHz to
          5th harmonic of highest frequency. The quasi-peak measuring receiver shall be in accordance with
          clause 2 of CISPR 16-1. Receivers with peak detectors shall be in accordance with clause 3 of CISPR
          16-1, and shall have a 6 dB bandwidth in accordance with clause 2 of CISPR 16-1.
                     Frequency of Emission (MHz)                    Field Strength QP Limit (dBuV/m) at 3m
                                  30~88                                                40
                                 88~216                                               43.5
                                 216~960                                               46

   3.2.2 Measuring Instruments and Setting
          Please refer to section 4 of equipments list in this report. The following table is the setting of spectrum
          analyzer and receiver.
            Receiver Parameter                           Setting
            Attenuation                                  Auto
            Start ~ Stop Frequency                       30MHz~1000MHz / RB 120kHz for QP

               Spectrum Parameter                        Setting
               Start Frequency                           1000 MHz
               Stop Frequency                            5th harmonic of highest frequency
               RB / VB                                   1 MHz / 1MHz for Peak; 1 MHz / 10Hz for Average


   3.2.3 Test Procedures
          1.     The EUT was placed on the top of the turntable 0.8 meter above ground. The phase center of the
                 receiving antenna mounted on the top of a height-variable antenna tower was placed 3 meters far
                 away from the turntable.
          2.     Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to
                 determine the position of the highest radiation.
          3.     The height of the broadband receiving antenna was varied between one meter and four meters
                 above ground to find the maximum emissions field strength of both horizontal and vertical
                 polarization.
          4.     For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the
                 turntable was rotated (from 0 degree to 360 degrees) to find the maximum reading.
          5.     Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified
                 bandwidth under Maximum Hold Mode.




SPORTON International Inc.                                                                  Page No.      : 10 of 22
TEL : 886-2-2696-2468                                                                       Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                 Report No. : FC110510


   3.2.4 Test Setup Layout




                                                              3m




   3.2.5 Test Deviation
          There is no deviation with the original standard.




SPORTON International Inc.                                         Page No.      : 11 of 22
TEL : 886-2-2696-2468                                              Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


  Fco Test Repont                                                                         Heport No: Ecrtosta

  32. Results of Radlated Emissions (30MHz~1GHz)
          Finai Test Bate       Dec. 27. 2010                         Test Site ho.    sschozny
          Temperature           2re                                   Humiity          sn
          Test Engineer         Cns                                   Goniquration     NomiMose
         Honzantal
               s Lovel abovim                                                                      se onz27
                                                                                                    reccusee
                                                                                                         "ab




                »|




               an 5                    ma                   m                    Ca          we.             ow
                                                                Iroquency tity




                                                  Over.   kinit      Reattatema. Cabie Presrp
                               treq:    Level.   Linit      Line.   Level Pactor Louw Factor Remark
                                c      awun          —a   awh        ow am           a~    a
           a                 ow         anae     cnen     ancen     anaz anae ncts mnn reak
           :                aet.me       ancee   coom     ancse     ssces sltn mae i94 reak
           a                rulase      anes     calrn    accon     siist oiz0 rlon enles reak
           a                asocose     ancar    ~ouss.   accen            ancas a.66. 2n.8e reak
           s                reecass     arior    calss    accoo     aelns mite ac9e. mnces reak
           6                seo.zzs     secor    calne     sacee    seisn miles slon moore reak




SFOmrONmtematoratie.                                                                      Farns        rrom
Te soc2zsosz0e                                                                            IssuedDate   Jon 28. z0
rax. ceszzsosems


   FCC TEST REPORT                                                                  Report No. : FC110510


            Vertical




            Note:
            The amplitude of spurious emissions that are attenuated by more than 20dB below the permissible
            value has no need to be reported.
            Emission level (dBuV/m) = 20 log Emission level (uV/m).
            Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.




SPORTON International Inc.                                                           Page No.      : 13 of 22
TEL : 886-2-2696-2468                                                                Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


  FCC Test REPORT                                                                      Heport No: Eortasta

  3,2.7 Results for Radlated Emisslons (1GHz~Sth harmonic of highest frequeney}
          Finai Test Bate   Jan. 10. 2om                       Test Site No:         sschozny
          Temperature       2re                                Humeity               sn
          Test Engineer     Cns                                Goniquration          cox 502 1i on.5
         Ronzontal
              i0 Lover atovim                                                                       pweczereras




               is                                                                            ree cuasssavsim
                    R   a




                "ew                Sim:              Sin:           i.                       To:             d
                                                         Frequency t




          +             uss.es      anes    ceas     siee    ssas    mner    qo      mt      reas
          —             aess.o00    anisn   ~nlar    secoe   socae   melse    rlre   92090   Peak
          a             ans.oo      aelse   cnael    silee   secas   recan   2iz     anlse   reak
          a             assecoos    aaise   colanl   silen   anor    enlon   2ige    azine   eak




SFONTONmematonatne.                                                                     Farus          nor
Te..sos22008200                                                                         IssuedDate     Jan 25. z011
rax ceszasssems


   FCC TEST REPORT                                                                  Report No. : FC110510


            Vertical




            Note:
            The amplitude of spurious emissions that are attenuated by more than 20dB below the permissible
            value has no need to be reported.
            Emission level (dBuV/m) = 20 log Emission level (uV/m).
            Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.




SPORTON International Inc.                                                           Page No.      : 15 of 22
TEL : 886-2-2696-2468                                                                Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


  FCC Test REPORT                                                                    Heport No: Eortasta

          Finai Test Bate   Jan. 10. 2on                         Test Site No.    sschozny
          Temperature       2re                                  Humiity          s%
          Test Engineer     Cns                                  Gonfiquration    orx 502 tm on.5 comm®)
         Ronzontal
              i0 Lovel abovim                                                                  pweczereras




               ®                                                                        ree cuisesavrcimn
                   &




                Cw                  Sim:              Sin:              En              To:              To
                                                          Frequency tity




                                             Over.    kinit     readintena. Cabie Preanp
                            treq:   evel    Linit      Line.   Level Tacton Lows Tactor Renask
                             ic     mam         —a   aumn       aw am           a~    a
                        snse.ass    anee    celar     seee     s9u95 milst oo ocms reak
                        ies sn       m      55e        mm       ic n n           omerarmzeval
          4             ares .000   aecss   ~ras      secon    secte 2ecas rlnd orles Peak
          a             aserloos    anles   chas      salen    anceel emlee 2lee anice reak




SFONTONmematonatne.                                                                   Faris        mor
Te..sos22008200                                                                       IssuedDate   Jan 25. z011
rax ceszasssems


   FCC TEST REPORT                                                                  Report No. : FC110510


            Vertical




            Note:
            The amplitude of spurious emissions that are attenuated by more than 20dB below the permissible
            value has no need to be reported.
            Emission level (dBuV/m) = 20 log Emission level (uV/m).
            Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.




SPORTON International Inc.                                                           Page No.      : 17 of 22
TEL : 886-2-2696-2468                                                                Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


  FCC Test RePont                                                                            Heport No : Eortasta


          Finai Test Date Dec. 27. 2010                               Test Site No.        sschozny
          Temperature       2re                                       Humiity              s%
          Test Engineer     Cns                                       Gonfiquration        orx 502 tm on.5 govng)
         Ronzontal
               ty Levelapuuim                                                                        poesrontz2r




                  «                                                                                ree; cuisss av.umy
                       +




                  Cw                   Sim:                Sin:             m                      To:            To
                                                               Frequency tte




                                                  Over.   Linit      teadintenna.   Cable Preanp
                               ¥req.   taver.    Linit      kine.   tevet ¥acton     Lore ¥actor   Renack
                                mc     nam           a    aah        ow am             a~
          1                aesi.ee     aecrn     cner      seee     sier iss         alen a0u90    Peak
          —                asse.oss    anlee     calne:    selee    som rnlee        nan nrise     rear
          a                resecoo     aalaz     coise|    salee    anion recar      2iz aniee     eak
          a                anez.o00    ances    cancae     sacen    anige: 2ec94.    2090 anire    veak




SFONTONmematonatne.                                                                           rans          —mor
Te sos22008200                                                                                IssuedDate    Jan 25. z01
rax ceszasssems


   FCC TEST REPORT                                                                  Report No. : FC110510


            Vertical




            Note:
            The amplitude of spurious emissions that are attenuated by more than 20dB below the permissible
            value has no need to be reported.
            Emission level (dBuV/m) = 20 log Emission level (uV/m).
            Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.




SPORTON International Inc.                                                           Page No.      : 19 of 22
TEL : 886-2-2696-2468                                                                Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                            Report No. : FC110510


   4 LIST OF MEASURING EQUIPMENTS
                                                                                              Calibration
            Instrument       Manufacturer    Model No.     Serial No.    Characteristics                           Remark
                                                                                                 Date
                                                                                                                  Conduction
           EMC Receiver          R&S          ESCS 30       100174       9kHz – 2.75GHz       Apr. 06, 2010
                                                                                                                  (CO04-HY)
                                                                                                                  Conduction
               LISN            MessTec       NNB-2/16Z       99041       9kHz – 30MHz         Mar. 23, 2010
                                                                                                                  (CO04-HY)
               LISN                                                                                               Conduction
                                EMCO         3810/2NM      9703-1839     9kHz – 30MHz         Apr. 29, 2010
           (Support Unit)                                                                                         (CO04-HY)
                                                                                                                  Conduction
          RF Cable-CON         UTIFLEX      3102-26886-4    CB049        9kHz – 30MHz         Apr. 20, 2010
                                                                                                                  (CO04-HY)
                                                                                                                  Conduction
             EMI Filter       LINDGREN       LRE-2030        2651              < 450 Hz           N/A
                                                                                                                  (CO04-HY)
       Note: Calibration Interval of instruments listed above is one year.

                                                                                               Calibration
            Instrument       Manufacturer    Model No.     Serial No.    Characteristics                           Remark
                                                                                                  Date
             Spectrum                                                                                              Radiation
                                 R&S           FSP40       100305/040        9 kHz - 40GHz    Feb. 02, 2010
             Analyzer                                                                                            (03CH02-HY)
         3m Semi Anechoic        SIDT                                    30 MHz - 1 GHz                            Radiation
                                              SAC-3M       03CH02-HY                          May 01, 2010
             Chamber          FRANKONIA                                       3m                                 (03CH02-HY)
                                                                                                                   Radiation
             Amplifier          Agilent        8447D       2944A11146   100 kHz – 1.3 GHz     Jul. 23, 2010
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
             Amplifier          Agilent        8449B       3008A02373    1GHz – 26.5 GHz      Jul. 23, 2010
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
           Horn Antenna      ETS-LINDGREN       3117        00091920         1GHz~18GHz       Nov. 11, 2010
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
          RF Cable-R03m         Jye Bao        RG142         CB021       30MHz ~ 1GHz         Feb. 26, 2010
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
          RF Cable-HIGH        SUHNER       SUCOFLEX106    03CH02-HY         1GHz~40GHz       Feb. 26, 2010
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
           Bilog Antenna      SCHAFFNER       CBL61128        2723       30 MHz - 2 GHz       Oct. 16, 2010
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
            Turn Table            HD           DS 420      420/649/00        0 - 360 degree        N/A
                                                                                                                 (03CH02-HY)
                                                                                                                   Radiation
           Antenna Mast           HD           MA 240      240/559/00          1m-4m               N/A
                                                                                                                 (03CH02-HY)
       Note: Calibration Interval of instruments listed above is one year.

                                                                                               Calibration
            Instrument       Manufacturer    Model No.     Serial No.    Characteristics                           Remark
                                                                                                  Date
                                                                                                                   Radiation
           Loop Antenna          R&S          HFH2-Z2      860004/001    9 kHz - 30 MHz       Jul. 29, 2010*
                                                                                                                 (03CH02-HY)
       Note: Calibration Interval of instruments listed above is two year.




SPORTON International Inc.                                                                    Page No.         : 20 of 22
TEL : 886-2-2696-2468                                                                         Issued Date      : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                                                                                 Report No. : FC110510


   5 TEST LOCATION
          SHIJR        ADD   :   6Fl., No. 106, Sec. 1, Shintai 5th Rd., Shijr City, Taipei, Taiwan 221, R.O.C.
                       TEL   :   886-2-2696-2468
                       FAX   :   886-2-2696-2255
          HWA YA       ADD   :   No. 52, Hwa Ya 1st Rd., Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.
                       TEL   :   886-3-327-3456
                       FAX   :   886-3-318-0055
          LINKOU       ADD   :   No. 30-2, Dingfu Tsuen, Linkou Shiang, Taipei, Taiwan 244, R.O.C
                       TEL   :   886-2-2601-1640
                       FAX   :   886-2-2601-1695
          DUNGHU       ADD   :   No. 3, Lane 238, Kangle St., Neihu Chiu, Taipei, Taiwan 114, R.O.C.
                       TEL   :   886-2-2631-4739
                       FAX   :   886-2-2631-9740
          JUNGHE       ADD   :   7Fl., No. 758, Jungjeng Rd., Junghe City, Taipei, Taiwan 235, R.O.C.
                       TEL   :   886-2-8227-2020
                       FAX   :   886-2-8227-2626
                                                            nd
          NEIHU        ADD   :   4Fl., No. 339, Hsin Hu 2        Rd., Taipei 114, Taiwan, R.O.C.
                       TEL   :   886-2-2794-8886
                       FAX   :   886-2-2794-9777
          JHUBEI       ADD   :   No.8, Lane 724, Bo-ai St., Jhubei City, HsinChu County 302, Taiwan, R.O.C.
                       TEL   :   886-3-656-9065
                       FAX   :   886-3-656-9085




SPORTON International Inc.                                                                         Page No.       : 21 of 22
TEL : 886-2-2696-2468                                                                              Issued Date    : Jan. 28, 2011
FAX : 886-2-2696-2255


   FCC TEST REPORT                        Report No. : FC110510


   6 NVLAP CERTIFICATE OF ACCREDITATION




SPORTON International Inc.                Page No.      : 22 of 22
TEL : 886-2-2696-2468                     Issued Date   : Jan. 28, 2011
FAX : 886-2-2696-2255



Document Created: 2019-10-15 17:15:49
Document Modified: 2019-10-15 17:15:49

© 2024 FCC.report