                  RF Exposure Report                                              Report No. :FA222113-03



1         Maximum Permissible Exposure
1.1       Maximum Permissible Exposure
1.1.1     Limit of Maximum Permissible Exposure
                             Limits for Occupational / Controlled Exposure
                                                                                         Averaging Time
 Frequency Range          Electric Field      Magnetic Field      Power Density (S)
                                                                                          |E|²,|H|² or S
      (MHz)             Strength (E) (V/m)   Strength (H) (A/m)      (mW/ cm²)
                                                                                            (minutes)
         0.3-3.0               614                 1.63                (100)*                    6
         3.0-30              1842 / f             4.89 / f            (900 / f)*                 6
         30-300               61.4                 0.163                 1.0                     6
        300-1500                                                       F/300                     6
    1500-100,000                                                          5                      6
                         Limits for General Population / Uncontrolled Exposure
                                                                                         Averaging Time
 Frequency Range          Electric Field      Magnetic Field      Power Density (S)
                                                                                          |E|²,|H|² or S
      (MHz)             Strength (E) (V/m)   Strength (H) (A/m)      (mW/ cm²)
                                                                                            (minutes)
        0.3-1.34               614                 1.63                (100)*                    30
        1.34-30               824/f                2.19/f              (180/f)*                  30
         30-300               27.5                 0.073                 0.2                     30
        300-1500                                                       F/1500                    30
    1500-100,000                                                         1.0                     30
Note 1: f = frequency in MHz ; *Plane-wave equivalent power density
Note 2: For the applicable limit, see FCC 1.1310




SPORTON INTERNATIONAL INC.                                             Page No.            : 1 of 3
TEL : 886-3-327-3456                                                   Report Version      : Rev. 01
FAX : 886-3-327-0973


                 RF Exposure Report                                             Report No. :FA222113-03



              RF Field Strength Limits for Controlled Use Devices (Controlled Environment)

 Frequency Range       Electric Field (V/m   Magnetic Field        Power Density         Averaging Time
      (MHz)                   rms)             (A/m rms)              (W/m2)               (minutes)
        0.003-1                600                    4.9                -                       6
          1-10                600/ƒ                  4.9/ƒ               -                       6
         10-30                 60                    4.9/ƒ               -                       6
         30-300                60                    0.163              10*                      6
        300-1500           3.54 ƒ 0.5          0.0094 ƒ 0.5            ƒ/30                      6
     1500-15000                137                   0.364              50                       6
    15000-150000               137                   0.364              50                616000/ƒ 1.2
   150000-300000           0.354 ƒ 0.5       9.4 x 10-4 ƒ 0.5      3.33 x 10-4 ƒ          616000/ƒ 1.2
     RF Field Strength Limits for Devices Used by the General Public (Uncontrolled Environment)
  Frequency Range          Electric Field     Magnetic Field       Power Density         Averaging Time
       (MHz)                (V/m rms)           (A/m rms)             (W/m2)               (minutes)
         0.003-1                280                   2.19                -                      6
          1-10                 280/ƒ                 2.19/ƒ               -                      6
          10-30                  28                  2.19/ƒ               -                      6
         30-300                  28                   0.073              2*                      6
        300-1500             1.585 ƒ 0.5           0.0042 ƒ 0.5        ƒ/150                     6
      1500-15000                61.4                  0.163              10                      6
     15000-150000               61.4                  0.163              10               616000/ƒ 1.2
    150000-300000            0.158 ƒ 0.5       4.21 x 10-4 ƒ 0.5    6.67 x 10-5 ƒ          616000/ƒ 1.2
Note 1: ƒ is frequency in MHz.
Note 2: For the applicable limit, see IC RSS-102


1.1.2     MPE Calculation Method
                                                                            2
E (V/m) =     30  P  G                     Power Density: Pd (W/m2) = E
                  d                                                       377
E = Electric field (V/m)                     P = RF output power (W)
G = EUT Antenna numeric gain (numeric)       d = Separation distance between radiator and human body (m)
The formula can be changed to
Pd = 30  P  G
        377  d 2




SPORTON INTERNATIONAL INC.                                              Page No.            : 2 of 3
TEL : 886-3-327-3456                                                    Report Version      : Rev. 01
FAX : 886-3-327-0973


                  RF Exposure Report                                                    Report No. :FA222113-03


1.1.3     Result of Maximum Permissible Exposure
                                 Transmitter Chains & Receiver Chains Information
                             Number of                                    Correlation
  IEEE Std. 802.11                              Number of Receive                              RF Output Power
                          Transmit Chains                                 Signals with
     Protocol                                     Chains (NRX)                                     (dBm)
                               (NTX)                                      Multiple NTX
              b                      1                   1                 Correlated               23.72
              g                      1                   1                 Correlated               21.81
        n (HT20)                     2                   2                Uncorrelated              24.77
        n (HT40)                     2                   2                Uncorrelated              22.24
Note 1: RF output power specifies that Maximum Conducted (Average) Output Power.


                                     Worst Maximum RF Output Power Result
    Exposure Environment             General Population / Uncontrolled Exposure
  Separation Distance (cm)           20
   Power Level             1                                   RF Output Power (dBm)
    Modulation                            RF Output                                                  PD (S)
                           NTX                               Gain (dBi)      EIRP Power
      Mode                               Power (dBm)                                                 (mW/cm²)

          b                1                23.72              2.80               26.52             0.08928
          g                1                21.81              2.80               24.61             0.05750
     n (HT20)              2                24.77              2.80               27.57             0.11368
     n (HT40)              2                22.24              2.80               25.04             0.06345
                       Maximum Permissible Exposure Limit (mW/cm²)                                       1
Note 1: NTX = Number of Transmit Chains




SPORTON INTERNATIONAL INC.                                                    Page No.            : 3 of 3
TEL : 886-3-327-3456                                                          Report Version      : Rev. 01
FAX : 886-3-327-0973



Document Created: 2018-08-12 03:36:38
Document Modified: 2018-08-12 03:36:38

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC