MPE 11n

FCC ID: NDD9574151017

RF Exposure Info

Download: PDF
FCCID_1495928

FCC TEST REPORT                      Report No.: FR921313-01AI




      Appendix A. Maximum Permissible Exposure




                                      Page No.   : A1 of A3
                                      FCC ID     : NDD9574151017


FCC TEST REPORT                                                                             Report No.: FR921313-01AI


1. Maximum Permissible Exposure
1.1. Applicable Standard

    Systems operating under the provisions of this section shall be operated in a manner that ensures that the
    public is not exposed to radio frequency energy levels in excess limit for maximum permissible exposure. In
    accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as a mobile device
    whereby a distance of 0.2 m normally can be maintained between the user and the device.
    (A) Limits for Occupational / Controlled Exposure
                                                                                                         Averaging Time
     Frequency Range             Electric Field       Magnetic Field      Power Density (S)
                                                                                                          |E|²,|H|² or S
          (MHz)                Strength (E) (V/m)   Strength (H) (A/m)       (mW/ cm²)
                                                                                                            (minutes)
            0.3-3.0                   614                  1.63                   (100)*                        6
            3.0-30                  1842 / f              4.89 / f               (900 / f)*                     6
            30-300                    61.4                0.163                       1.0                       6
           300-1500                                                               F/300                         6
        1500-100,000                                                                   5                        6
    (B) Limits for General Population / Uncontrolled Exposure
                                                                                                         Averaging Time
     Frequency Range             Electric Field       Magnetic Field      Power Density (S)
                                                                                                          |E|²,|H|² or S
          (MHz)                Strength (E) (V/m)   Strength (H) (A/m)       (mW/ cm²)
                                                                                                            (minutes)
           0.3-1.34                   614                  1.63                   (100)*                       30
            1.34-30                  824/f                2.19/f                  (180/f)*                     30
            30-300                   27.5                 0.073                       0.2                      30
           300-1500                                                               F/1500                       30
        1500-100,000                                                                  1.0                      30
    Note: f = frequency in MHz ; *Plane-wave equivalent power density

1.2. MPE Calculation Method

                30  P  G                                                      E2
    E (V/m) =                                  Power Density:     Pd (W/m²) =
                    d                                                           377
    E = Electric field (V/m)
    P = Peak RF output power (W)
    G = EUT Antenna numeric gain (numeric)
    d = Separation distance between radiator and human body (m)
    The formula can be changed to

    Pd =
           30  P  G
            377  d 2
    From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the gain of
    the used antenna, the RF power density can be obtained.


                                                                                              Page No.      : A2 of A3
                                                                                              FCC ID        : NDD9574151017


FCC TEST REPORT                                                             Report No.: FR921313-01AI


1.3. Calculated Result and Limit

    Max Conducted Power for IEEE 802.11n (20MHz) port A: 23.39dBm
      Test     Min. User                                  Conducted      Conducted      Power Density
                             Gain (dBi)   Numeric Gain
      Mode   Distance (cm)                               Power (dBm)    Power (mW)       (mW/cm2)
      2.4G        20              5         3.162278         23.39        218.2730          0.1374




    Max Conducted Power for IEEE 802.11n (20MHz) port B: 23.01dBm
      Test     Min. User                                  Conducted      Conducted      Power Density
                             Gain (dBi)   Numeric Gain
      Mode   Distance (cm)                               Power (dBm)    Power (mW)       (mW/cm2)
      2.4G        20              5         3.162278         23.01        199.9862          0.1259
    IEEE 802.11n (20MHz) port A + port B Power Density = 0.1374 + 0.1259 = 0.2633 (mW/cm2)




    Max Conducted Power for IEEE 802.11n (40MHz) port A: 21.56dBm
      Test     Min. User                                  Conducted      Conducted      Power Density
                             Gain (dBi)   Numeric Gain
      Mode   Distance (cm)                               Power (dBm)    Power (mW)       (mW/cm2)
      2.4G        20              5         3.162278         21.56        143.2188          0.0901




    Max Conducted Power for IEEE 802.11n (40MHz) port B: 21.27dBm
      Test     Min. User                                  Conducted      Conducted      Power Density
                             Gain (dBi)   Numeric Gain
      Mode   Distance (cm)                               Power (dBm)    Power (mW)       (mW/cm2)
      2.4G        20              5         3.162278         21.27        133.9677          0.0843
    IEEE 82.11n (40MHz) port A + port B Power Density = 0.0901 + 0.0843 = 0.1744 (mW/cm2)




                                                                             Page No.    : A3 of A3
                                                                             FCC ID      : NDD9574151017



Document Created: 2011-07-05 17:15:01
Document Modified: 2011-07-05 17:15:01

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC