MPE

FCC ID: NDD9564281303

RF Exposure Info

Download: PDF
FCCID_2153852

           FCC EMF Test Report                                                          Report No. : FA370530



1         Human Exposure Assessment
1.1       Maximum Permissible Exposure
1.1.1     Limit of Maximum Permissible Exposure
                             Limits for Occupational / Controlled Exposure
                                                                                        Averaging Time
 Frequency Range         Electric Field       Magnetic Field     Power Density (S)
                                                                                         |E|²,|H|² or S
      (MHz)            Strength (E) (V/m)   Strength (H) (A/m)      (mW/ cm²)
                                                                                          (minutes)
         0.3-3.0              614                  1.63                (100)*                   6
         3.0-30              1842 / f             4.89 / f            (900 / f)*                6
         30-300               61.4                0.163                  1.0                    6
        300-1500                -                    -                 F/300                    6
    1500-100,000                -                    -                    5                     6
                        Limits for General Population / Uncontrolled Exposure
                                                                                        Averaging Time
 Frequency Range         Electric Field       Magnetic Field     Power Density (S)
                                                                                         |E|²,|H|² or S
      (MHz)            Strength (E) (V/m)   Strength (H) (A/m)      (mW/ cm²)
                                                                                          (minutes)
        0.3-1.34              614                  1.63                (100)*                   30
        1.34-30               824/f               2.19/f              (180/f)*                  30
         30-300               27.5                0.073                  0.2                    30
        300-1500                -                    -                F/1500                    30
    1500-100,000                -                    -                   1.0                    30
Note 1: f = frequency in MHz ; *Plane-wave equivalent power density
Note 2: For the applicable limit, see FCC 1.1310




SPORTON INTERNATIONAL INC.                                             Page No.           : 1 of 3
TEL : 886-3-327-3456                                                   Report Version     : Rev. 01
FAX : 886-3-327-0973


            FCC EMF Test Report                                                                   Report No. : FA370530



              RF Field Strength Limits for Controlled Use Devices (Controlled Environment)

 Frequency Range       Electric Field (V/m   Magnetic Field               Power Density          Averaging Time
      (MHz)                   rms)             (A/m rms)                     (W/m2)                (minutes)
        0.003-1               600                    4.9                         -                       6
          1-10               600/ƒ                   4.9/ƒ                       -                       6
         10-30                 60                    4.9/ƒ                       -                       6
         30-300                60                   0.163                       10*                      6
        300-1500           3.54 ƒ 0.5          0.0094 ƒ 0.5                     ƒ/30                     6
     1500-15000               137                   0.364                        50                      6
    15000-150000              137                   0.364                        50               616000/ƒ 1.2
   150000-300000           0.354 ƒ 0.5       9.4 x 10-4 ƒ 0.5             3.33 x 10-4 ƒ           616000/ƒ 1.2
     RF Field Strength Limits for Devices Used by the General Public (Uncontrolled Environment)
  Frequency Range          Electric Field     Magnetic Field              Power Density          Averaging Time
       (MHz)                 (V/m rms)          (A/m rms)                    (W/m2)                (minutes)
         0.003-1                280                   2.19                        -                      6
          1-10                 280/ƒ                 2.19/ƒ                       -                      6
          10-30                 28                   2.19/ƒ                       -                      6
         30-300                 28                   0.073                       2*                      6
                                       0.5                        0.5
        300-1500             1.585 ƒ               0.0042 ƒ                     ƒ/150                    6
      1500-15000               61.4                  0.163                       10                      6
                                                                                                                1.2
    15000-150000               61.4                  0.163                       10               616000/ƒ
                                       0.5                   -4     0.5                 -5                      1.2
    150000-300000            0.158 ƒ           4.21 x 10 ƒ                 6.67 x 10 ƒ            616000/ƒ
Note 1: ƒ is frequency in MHz.
Note 2: For the applicable limit, see IC RSS-102


1.1.2     MPE Calculation Method
              30  P  G                                                    2     E2
E (V/m) =                                    Power Density: Pd (W/m ) =
                  d                                                               377
E = Electric field (V/m)                     P = RF output power (W)
G = EUT Antenna numeric gain (numeric)       d = Separation distance between radiator and human body (m)
The formula can be changed to
Pd =
      30  P  G
        377  d 2




SPORTON INTERNATIONAL INC.                                                      Page No.            : 2 of 3
TEL : 886-3-327-3456                                                            Report Version      : Rev. 01
FAX : 886-3-327-0973


          FCC EMF Test Report                                                                   Report No. : FA370530


1.1.3     Result of Maximum Permissible Exposure
                                 Transmitter Chains & Receiver Chains Information
                              Number of                                  Correlation
  IEEE Std. 802.11                              Number of Receive                             RF Output Power
                           Transmit Chains                               Signals with
     Protocol                                     Chains (NRX)                                    (dBm)
                                (NTX)                                    Multiple NTX
           b                         1                  1                 Correlated               13.18
           g                         1                  1                 Correlated               21.52
        n (HT20)                     2                  2                Uncorrelated              22.03
        n (HT40)                     2                  2                Uncorrelated              18.59
Note 1: RF output power specifies that Maximum Conducted (Average) Output Power.


                                     Worst Maximum RF Output Power Result
    Exposure Environment             General Population / Uncontrolled Exposure
  Separation Distance (cm)           20
   Power Level             1                                  RF Output Power (dBm)
    Modulation                            RF Output                                                 PD (S)
                           NTX                              Gain (dBi)      EIRP Power
      Mode                               Power (dBm)                                                (mW/cm²)

     11B-20M               1                13.18             9.00              22.18              0.03286
     11G-20M               1                21.52             9.00              30.52              0.22425
  11N2.4G-20M              2                22.03             9.00              31.03              0.25194
  11N2.4G-40M              2                18.59             9.00              27.59              0.11427
                       Maximum Permissible Exposure Limit (mW/cm²)                                      1
Note 1: NTX = Number of Transmit Chains




SPORTON INTERNATIONAL INC.                                                   Page No.            : 3 of 3
TEL : 886-3-327-3456                                                         Report Version      : Rev. 01
FAX : 886-3-327-0973



Document Created: 2019-11-12 13:26:38
Document Modified: 2019-11-12 13:26:38

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC