RF Exposure Info

FCC ID: NDD9564250909

RF Exposure Info

Download: PDF
FCCID_1319381

                                                                                         RV-1003005
              Neutron Engineering Inc.

 9. RF EXPOSURE TEST

 9.1 APPLIED PROCEDURES / LIMIT
 Systems operating under the provisions of this section shall be operated in a manner that ensures
 that the public is not exposed to radio frequency energy levels in excess limit for maximum
 permissible exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this
 device has been defined as a mobile device whereby a distance of 0.2 m normally can be
 maintained between the user and the device.

  (A) Limits for Occupational / Controlled Exposure
                        Electric Field     Magnetic Field                       Averaging Time
 Frequency Range                                           Power Density (S)
                        Strength (E)        Strength (H)                          |E|2,|H|2or S
        (MHz)                                                 (mW/ cm2)
                            (V/m)              (A/m)                               (minutes)
        0.3-3.0              614                1.63             (100)*                 6
        3.0-30             1842 / f            4.89 / f        (900 / f)*               6
        30-300               61.4               0.163              1.0                  6
      300-1500                                                   F/300                  6
    1500-100,000                                                    5                   6
 (B) Limits for General Population / Uncontrolled Exposure
                        Electric Field     Magnetic Field                       Averaging Time
 Frequency Range                                           Power Density (S)
                        Strength (E)        Strength (H)                         |E|2,|H|2 or S
        (MHz)                                                 (mW/ cm2)
                            (V/m)              (A/m)                              (minutes)
       0.3-1.34              614                1.63             (100)*                30
       1.34-30              824/f              2.19/f           (180/f)*               30
        30-300               27.5               0.073              0.2                 30
      300-1500                                                  F/1500                 30
    1500-100,000                                                   1.0                 30
 Note: f = frequency in MHz ; *Plane-wave equivalent power density

  9.1.1 MEASUREMENT INSTRUMENTS LIST

  Item Kind of Equipment       Manufacturer       Type No.       Serial No.     Calibrated until
    1     Power Meter            Anritsu          ML2487A       6K00004714      Feb. 10, 2011
          Power Meter
    2                             Anritsu         MA2491A          34138         Feb. 10, 2011
            Sensor

     Remark: ” N/A” denotes No Model Name , Serial No. or No Calibration specified.

  9.1.2 MPE CALCULATION METHOD

        E (V/m) =
                     30 × P × G                Power Density:    Pd (W/m²) =
                                                                               E2
                         d                                                     377
       E = Electric field (V/m)
       P = Peak RF output power (W)
       G = EUT Antenna numeric gain (numeric)
       d = Separation distance between radiator and human body (m)
       The formula can be changed to
       Pd =
              30 × P × G
               377 × d 2
  From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well
  as the gain of the used antenna, the RF power density can be obtained

Report No.: NEI-FCCP-1-0907C089                                                      Page 133 of 141


                                                                                      RV-1003005
              Neutron Engineering Inc.

  9.1.3 DEVIATION FROM STANDARD

  No deviation.

  9.1.4 TEST SETUP




  9.1.5 EUT OPERATION CONDITIONS

  The EUT tested system was configured as the statements of 4.1.6 Unless otherwise a special
  operating condition is specified in the follows during the testing.




Report No.: NEI-FCCP-1-0907C089                                                  Page 134 of 141


                                                                                    RV-1003005
             Neutron Engineering Inc.

  9.1.6 TEST RESULTS

  EUT:               Wireless N Broadband Router Model Name :       BR-6425N
  Temperature:       13℃                         Relative Humidity: 64%
  Test Voltage:      AC 120V/60Hz
  Test Mode :        802.11b


                                                                               Limit of Power
  Frequency Antenna Antenna Gain Peak Output Peak Output Power Density
                                                                                 Density (S)
    (MHz)   Gain (dBi) (numeric) Power (dBm) Power (mW) (S) (mW/cm2)
                                                                                 (mW/cm2)
    2412          3.00      1.9953      14.4500     27.8612      0.011065            1

    2437          3.00      1.9953      14.0000     25.1189      0.009976            1

    2462          3.00      1.9953      14.0800     25.5859      0.010161            1

  EUT:               Wireless N Broadband Router Model Name :       BR-6425N
  Temperature:       13℃                         Relative Humidity: 64%
  Test Voltage:      AC 120V/60Hz
  Test Mode :        802.11g


                                                                               Limit of Power
  Frequency Antenna Antenna Gain Peak Output Peak Output Power Density
                                                                                 Density (S)
    (MHz)   Gain (dBi) (numeric) Power (dBm) Power (mW) (S) (mW/cm2)
                                                                                 (mW/cm2)
    2412          3.00      1.9953      24.7400     297.8516     0.118291            1

    2437          3.00      1.9953      24.5300     283.7919     0.112707            1

    2462          3.00      1.9953      23.8100     240.4363     0.095488            1




Report No.: NEI-FCCP-1-0907C089                                                Page 135 of 141


                                                                                    RV-1003005
             Neutron Engineering Inc.

  EUT:               Wireless N Broadband Router Model Name :       BR-6425N
  Temperature:       13℃                         Relative Humidity: 64%
  Test Voltage:      AC 120V/60Hz
  Test Mode :        802.11n HT20 Single TX (TX No.1)


                                                                               Limit of Power
  Frequency Antenna Antenna Gain Peak Output Peak Output Power Density
                                                                                 Density (S)
    (MHz)   Gain (dBi) (numeric) Power (dBm) Power (mW) (S) (mW/cm2)
                                                                                 (mW/cm2)
    2412          3.00      1.9953      19.7800     95.06050     0.037753            1

    2437          3.00      1.9953      21.9600     157.0363     0.062366            1

    2462          3.00      1.9953      22.1800     165.1962     0.065607            1

  EUT:               Wireless N Broadband Router Model Name :       BR-6425N
  Temperature:       13℃                         Relative Humidity: 64%
  Test Voltage:      AC 120V/60Hz
  Test Mode :        802.11n HT20 Single TX (TX No.2)


                                                                               Limit of Power
  Frequency Antenna Antenna Gain Peak Output Peak Output Power Density
                                                                                 Density (S)
    (MHz)   Gain (dBi) (numeric) Power (dBm) Power (mW) (S) (mW/cm2)
                                                                                 (mW/cm2)
    2412          3.00      1.9953      18.9700     78.8860      0.031329            1

    2437          3.00      1.9953      21.4000     138.0384     0.054821            1

    2462          3.00      1.9953      21.5700     143.5489     0.057010            1

  EUT:               Wireless N Broadband Router Model Name :       BR-6425N
  Temperature:       13℃                         Relative Humidity: 64%
  Test Voltage:      AC 120V/60Hz
  Test Mode :        802.11n HT20 Dual TX (TX No.1 + TX No.2)


                                                                               Limit of Power
  Frequency Antenna Antenna Gain Peak Output Peak Output Power Density
                                                                                 Density (S)
    (MHz)   Gain (dBi) (numeric) Power (dBm) Power (mW) (S) (mW/cm2)
                                                                                 (mW/cm2)
    2412          6.00      3.9811      22.4042     173.9465     0.137837            1

    2437          6.00      3.9811      24.6993     295.0747     0.233820            1

    2462          6.00      3.9811      24.8960     308.7451     0.244653            1

  Remark:
       (1) The MIMO test requirement, MPE shall measure by using the total sum power of each
           transmitter chain.




Report No.: NEI-FCCP-1-0907C089                                                Page 136 of 141


                                                                                    RV-1003005
             Neutron Engineering Inc.

  EUT:               Wireless N Broadband Router Model Name :       BR-6425N
  Temperature:       13℃                         Relative Humidity: 64%
  Test Voltage:      AC 120V/60Hz
  Test Mode :        802.11n HT40 Single TX (TX No.1)


                                                                               Limit of Power
  Frequency Antenna Antenna Gain Peak Output Peak Output Power Density
                                                                                 Density (S)
    (MHz)   Gain (dBi) (numeric) Power (dBm) Power (mW) (S) (mW/cm2)
                                                                                 (mW/cm2)
    2412          3.00      1.9953      20.2000     104.7129     0.041586            1

    2437          3.00      1.9953      21.8100     151.7050     0.060249            1

    2462          3.00      1.9953      20.2000     104.7129     0.041586            1

  EUT:               Wireless N Broadband Router Model Name :       BR-6425N
  Temperature:       13℃                         Relative Humidity: 64%
  Test Voltage:      AC 120V/60Hz
  Test Mode :        802.11n HT40 Single TX (TX No.2)


                                                                               Limit of Power
  Frequency Antenna Antenna Gain Peak Output Peak Output Power Density
                                                                                 Density (S)
    (MHz)   Gain (dBi) (numeric) Power (dBm) Power (mW) (S) (mW/cm2)
                                                                                 (mW/cm2)
    2412          3.00      1.9953      20.2100     104.9542     0.041682            1

    2437          3.00      1.9953      21.8400     152.7566     0.060667            1

    2462          3.00      1.9953      20.1000     102.3293     0.040640            1

  EUT:               Wireless N Broadband Router Model Name :       BR-6425N
  Temperature:       13℃                         Relative Humidity: 64%
  Test Voltage:      AC 120V/60Hz
  Test Mode :        802.11n HT40 Dual TX (TX No.1 + TX No.2)


                                                                               Limit of Power
  Frequency Antenna Antenna Gain Peak Output Peak Output Power Density
                                                                                 Density (S)
    (MHz)   Gain (dBi) (numeric) Power (dBm) Power (mW) (S) (mW/cm2)
                                                                                 (mW/cm2)
    2412          6.00      3.9811      23.2153     209.6671     0.166142            1

    2437          6.00      3.9811      24.8353     304.4616     0.241259            1

    2462          6.00      3.9811      23.1606     207.0422     0.164062            1

  Remark:
       (1) The MIMO test requirement, MPE shall measure by using the total sum power of each
           transmitter chain.




Report No.: NEI-FCCP-1-0907C089                                                Page 137 of 141



Document Created: 2010-05-19 18:29:24
Document Modified: 2010-05-19 18:29:24