    FCC TEST REPORT                 Report No. : FR070629-02AC




       Appendix A. Maximum Permissible Exposure




                                          Page No.   : A1 of A3
                                          FCC ID     : NDD9562281018


F
    FCC TEST REPORT                                                            Report No. : FR070629-02AC


    1. Maximum Permissible Exposure
    1.1. Applicable Standard
        Systems operating under the provisions of this section shall be operated in a manner that ensures that
        the public is not exposed to radio frequency energy levels in excess limit for maximum permissible
        exposure. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been
        defined as a mobile device whereby a distance of 0.2 m normally can be maintained between the user
        and the device.
        (A) Limits for Occupational / Controlled Exposure
                                                                                                  Averaging Time
          Frequency Range         Electric Field        Magnetic Field      Power Density (S)
                                                                                                    |E|²,|H|² or S
                (MHz)           Strength (E) (V/m) Strength (H) (A/m)           (mW/ cm²)
                                                                                                      (minutes)
                0.3-3.0                 614                   1.63                  (100)*                 6
                3.0-30                1842 / f              4.89 / f              (900 / f)*               6
                30-300                  61.4                 0.163                    1.0                  6
              300-1500                                                              F/300                  6
            1500-100,000                                                               5                   6
        (B) Limits for General Population / Uncontrolled Exposure
                                                                                                  Averaging Time
          Frequency Range         Electric Field        Magnetic Field      Power Density (S)
                                                                                                    |E|²,|H|² or S
                (MHz)           Strength (E) (V/m) Strength (H) (A/m)           (mW/ cm²)
                                                                                                     (minutes)
               0.3-1.34                 614                  1.63                   (100)*                30
               1.34-30                 824/f                 2.19/f                (180/f)*               30
                30-300                  27.5                 0.073                    0.2                 30
              300-1500                                                             F/1500                 30
            1500-100,000                                                              1.0                 30
        Note: f = frequency in MHz ; *Plane-wave equivalent power density

    1.2. MPE Calculation Method

                    30  P  G                                                 E2
        E (V/m) =                              Power Density:    Pd (W/m²) =
                        d                                                      377
        E = Electric field (V/m)
        P = Peak RF output power (W)
        G = EUT Antenna numeric gain (numeric)
        d = Separation distance between radiator and human body (m)
        The formula can be changed to

        Pd =
               30  P  G
                377  d 2
        From the peak EUT RF output power, the minimum mobile separation distance, d=0.2m, as well as the
        gain of the used antenna, the RF power density can be obtained.




                                                                                      Page No.   : A2 of A3
                                                                                      FCC ID     : NDD9562281018


F
    FCC TEST REPORT                                                 Report No. : FR070629-02AC


    1.3. Calculated Result and Limit
        Antenna Type : Dipole Antenna
        Max Conducted Power for IEEE 802.11b/g: 17.39dBm
                                                                                                      Power
          Test     Min. User                                   Conducted       Conducted
                                 Gain (dBi)    Numeric Gain                                          Density
          Mode   Distance (cm)                                Power (dBm)      Power (mW)
                                                                                                    (mW/cm2)
          2.4G        20             5           3.162278        17.39           54.8277             0.0345