  FCC ID: N82-KOHLER036                   ISED No.: 4554A-KOHLER036                          Page:    1 / 32
Report No.: T190220D01-RP                                                                     Rev.:   02


          FCC RADIO TEST REPORT
               FCC 47 CFR PART 15 SUBPART C
                       INDUSTRY CANADA RSS-310
 Test Standard             FCC Part 15.249
                           IC RSS-310 issue 4 and IC RSS-GEN issue 5
 Trade name                KOHLER
 Product name              New Microwave Sensor
 Model No.                 1384310, 1384311, 1384312, 1384313, 1384314, 1386373,
                           1386374, 1386375, 1386376
 Test Result               Pass


The test Result was tested by Compliance Certification Services Inc. The test data, data
evaluation, test procedures, and equipment configurations shown in this report were
given in ANSI C63.10: 2013 and compliance standards.
The test results of this report relate only to the tested sample (EUT) identified in this
report.
The test Report of full or partial shall not copy. Without written approval of Compliance
Certification Services Inc. (Wugu Laboratory)




Approved by:                                           Tested by:




Kevin Tsai                                             Dally Hong
Deputy Manager                                         Engineer




                         No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan / 新北市五股區五工六路 11 號
                                                t:(886-2) 2299-9720 f:(886-2) 2298-1882 www.sgs.tw www.ccsrf.com


                                                                                       Page:    2 / 32
  Report No.: T190220D01-RP                                                             Rev.:   02


                                Revision History
Rev.    Issue Date                     Revisions                    Effect Page         Revised By
 00    March 20, 2019                 Initial Issue                     ALL              May Lin
                        1. Revised the EUT information、           P.4, P.6, P.13-14,
01     April 03, 2019   measurement uncertainty、test                P.17, P.20-21,        May Lin
                        procedure、test plot and test results.       P.23, P.26-31

                        1. Revised the EUT information and test
02     April 11, 2019                                                 P.4, P.18           May Lin
                        procedure.


                                                                                                                   Page:      3 / 32
   Report No.: T190220D01-RP                                                                                        Rev.:     02


                                           Table of contents
1. GENERAL INFORMATION .................................................................................................. 4

1.1 EUT INFORMATION ............................................................................................................ 4

1.2 EUT CHANNEL INFORMATION .......................................................................................... 5

1.3 ANTENNA INFORMATION .................................................................................................. 5

1.4 MEASUREMENT UNCERTAINTY ....................................................................................... 6

1.5 FACILITIES AND TEST LOCATION .................................................................................... 7

1.6 INSTRUMENT CALIBRATION ............................................................................................. 8

1.7 SUPPORT AND EUT ACCESSORIES EQUIPMENT ........................................................... 9

2. TEST SUMMERY ............................................................................................................... 10

3. DESCRIPTION OF TEST MODES ..................................................................................... 11

3.1 THE WORST MODE OF MEASUREMENT ........................................................................ 11

4. TEST RESULT ................................................................................................................... 12

4.1 AC POWER LINE CONDUCTED EMISSION ..................................................................... 12

4.2 20dB BANDWIDTH AND OCCUPIED BANDWIDTH (99%) .............................................. 13

4.3 FIELD STRENGTH OF FUNDAMENTAL AND RADIATION SPURIOUS EMISSION ........ 15

APPENDIX 1 - PHOTOGRAPHS OF EUT


                                                                                               Page:    4 / 32
  Report No.: T190220D01-RP                                                                     Rev.:   02

1. GENERAL INFORMATION
1.1 EUT INFORMATION
                                 Kohler Co.
Applicant
                                 444 Highland Drive Kohler, WI 53044 United States
                                 Shanghai Kohler Electronics., Ltd.
Manufacturer                     No. 1955, Fengxiang Road, Baoshan Area, Shanghai, PRC Post
                                 code: 200444
Equipment                        New Microwave Sensor
                                 1384310, 1384311, 1384312, 1384313, 1384314, 1386373,
Model Name
                                 1386374, 1386375, 1386376
Model Discrepancy                See the following Note 1

EUT Functions                    24G Radar

Received Date                    February 20, 2019

Date of Test                     March 06 ~ April 03, 2019
                                 Peak : 79.83dBuV/m
Output Power
                                 Average : 64.65dBuV/m

                                      AC
                                      DC Type:
Power Operation                          Battery
                                         DC Power Supply: 5V
                                         External DC adapter
Note:
1. Difference of the five samples (list on this report) please see as below:
          New Microwave                                                         Cable Length
 No.                         Part No./ Material No.            Difference
             Sensor                                                                (mm)
                                     1384310                  Main Model           800+
                                     1384311             Cable Length & Order    500 - 600
                                     1384312                 Cable Length        250 - 300
                                                            Cable Length &
                                     1384313                                       800+
                                                            Connector Type
                                                            Cable Length &
                                     1386373                                       500+
   1       Right-angle                                      Connector Type
                                                            Cable Length &
                                     1386374                                       500+
                                                            Connector Type
                                                            Cable Length &
                                     1386375                                       500+
                                                            Connector Type
                                                            Cable Length &
                                     1386376                                       500+
                                                            Connector Type
   2      Chamfer-angle              1384314                  Main Model           700+


                                                    Page:    5 / 32
 Report No.: T190220D01-RP                           Rev.:   02

1.2 EUT CHANNEL INFORMATION
Center Frequency
                        24.125GHz(24GHz-24.25GHz)
Frequency Range

Modulation Type         FMCW


Number of channel       1

1.3 ANTENNA INFORMATION
                                      PIFA
                                      PCB
Antenna Type                          Dipole
                                      Printed
                                      Coils

Antenna Gain                       0 dBi

Antenna Connector                  N/A


                                                                                      Page:    6 / 32
  Report No.: T190220D01-RP                                                            Rev.:   02

1.4 MEASUREMENT UNCERTAINTY
                 PARAMETER                            UNCERTAINTY
AC Powerline Conducted Emission                               N/A
Emission bandwidth, 20dB bandwidth                         +/- 0.0014
RF output power, conducted                                  +/- 1.14
Power density, conducted                                    +/- 1.40
3M Semi Anechoic Chamber / 30M~200M                         +/- 4.12
3M Semi Anechoic Chamber / 200M~1000M                       +/- 4.68
3M Semi Anechoic Chamber / 1G~8G                            +/- 5.18
3M Semi Anechoic Chamber / 8G~18G                           +/- 5.47
3M Semi Anechoic Chamber / 18G~26G                          +/- 3.81
3M Semi Anechoic Chamber / 26G~40G                          +/- 3.87
3M Semi Anechoic Chamber / 40G~60G                         +/- 1.8509
3M Semi Anechoic Chamber / 60G~90G                          +/- 3.43
3M Semi Anechoic Chamber / 90G~140G                          +/- 3.52
Remark:
1.This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=2
2. ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the
emissions test results be included in the report.


                                                                                       Page:    7 / 32
  Report No.: T190220D01-RP                                                             Rev.:   02

1.5 FACILITIES AND TEST LOCATION
All measurement facilities used to collect the measurement data are located at
No.11, Wugong 6th Rd., Wugu Dist., New Taipei City 24891, Taiwan. (R.O.C.)

              Test site                          Test Engineer                  Remark
         AC Conduction Room                            -                          -
              Radiation                           Dally Hong                      -
            RF Conducted                          Dally Hong                      -
Remark: The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.4 and
CISPR Publication 22.


                                                                                         Page:    8 / 32
  Report No.: T190220D01-RP                                                               Rev.:   02



1.6 INSTRUMENT CALIBRATION
                                  3M 966A Chamber Test Site
Name of Equipment      Manufacturer     Model      Serial Number             Cal Date      Cal Due
                         MICRO
 Band Reject Filters                  BRM 50702          120                05/14/2018   05/13/2019
                        TRONICS
    Bilog Antenna      Sunol Sciences        JB3             A030105        07/13/2018   07/12/2019
                          HUBER          SUCOFLEX
        Cable                                                 25157         06/29/2018   06/28/2019
                         SUHNER           104PEA
                          HUBER          SUCOFLEX
        Cable                                                 20995         06/29/2018   06/28/2019
                         SUHNER           104PEA
  Digital Thermo-
                        WISEWIND             1206              D07          01/30/2019   01/29/2020
    Hygro Meter
double Ridged Guide
                            ETC          MCTD 1209        DRH13M02003       08/20/2018   08/19/2019
   Horn Antenna
      Loop Ant         COM-POWER            AL-130           121051         03/21/2018   03/20/2019
    Pre-Amplifier          EMEC             EM330            060609         06/29/2018   06/28/2019
    Pre-Amplifier            HP             8449B          3008A00965       06/29/2018   06/28/2019
PSA Series Spectrum
                           Agilent         E4446A          MY46180323       05/31/2018   05/30/2019
     Analyzer
   Antenna Tower            CCS            CC-A-1F             N/A            N.C.R         N.C.R
      Controller            CCS            CC-C-1F             N/A            N.C.R         N.C.R
     Turn Table             CCS            CC-T-1F             N/A            N.C.R         N.C.R
        Mixer             Keysight        11974VE01        MY30012006       09/01/2016   08/31/2019
        Mixer             Keysight        11974VE01        MY30012006       08/19/2016   08/18/2019
        Mixer             Keysight       N9029AV08         US53250002       08/19/2016   08/18/2019
        Mixer             Keysight       N9029AV05         US53250003       08/24/2016   08/23/2019
    Horn Antenna            CMI             WR15            WR15-01         08/29/2016   08/28/2019
    Horn Antenna            CMI             WR12            WR12-01         08/19/2016   09/18/2019
    Horn Antenna            CMI             WR8.0            WR8-01         05/30/2016   05/29/2019
    Horn Antenna            CMI             WR8.0            WR8-02         08/24/2016   08/23/2019
    Horn Antenna            CMI             WR5.1           WR5.1-01        08/29/2016   08/28/2019
   PXA Spectrum
                         Agilent         N9030A            MY53120760       04/09/2018   04/08/2019
     Analyzer
Remark: Each piece of equipment is scheduled for calibration once a year.


                                                                          Page:    9 / 32
 Report No.: T190220D01-RP                                                 Rev.:   02

1.7 SUPPORT AND EUT ACCESSORIES EQUIPMENT
                              EUT Accessories Equipment
 No.         Equipment        Brand        Model          Series No.       FCC ID
                N/A

                                  Support Equipment
 No.         Equipment        Brand        Model          Series No.       FCC ID
  1.            NB            Lenovo   Thinkpad L460         N/A             N/A
  2.       USB Test Board      N/A       test plate 2        N/A             N/A


1.8 TEST METHODOLOGY AND APPLIED STANDARDS
The test methodology, setups and results comply with all requirements in accordance
with ANSI C63.10:2013, FCC Part 15.249, RSS-310 Issue 4 and RSS-GEN Issue 5.


       .


                                                                   Page:     10 / 32
 Report No.: T190220D01-RP                                          Rev.:    02

2. TEST SUMMERY
  FCC       IC Standard
                             Report
Standard      Section                            Test Item              Result
                             Section
 Section
 15.203          -             1.3          Antenna Requirement             Pass
15.207(a)   RSS-GEN 8.8        4.1         AC Conducted Emission            N/A
                                               20dB Bandwidth
 15.215       RSS-210          4.2                                          Pass
                                       and Occupied Bandwidth (99%)
15.249(a)   RSS-310 3.10       4.3      Filed strength of fundamental       Pass
            RSS-GEN 8.9,
15.249(a)                      4.3      Radiation Spurious Emission         Pass
                8.10


                                                                             Page:    11 / 32
  Report No.: T190220D01-RP                                                   Rev.:   02

3. DESCRIPTION OF TEST MODES
3.1 THE WORST MODE OF MEASUREMENT

                    Radiated Emission Measurement Above 1G
  Test Condition          Band edge, Emission for Unwanted and Fundamental
Power supply Mode Mode 1: EUT power by host system (DC 5V)
    Worst Mode             Mode 1       Mode 2     Mode 3       Mode 4
                           Placed in fixed position.
                           Placed in fixed position at X-Plane (E2-Plane)
  Worst Position
                           Placed in fixed position at Y-Plane (E1-Plane)
                           Placed in fixed position at Z-Plane (H-Plane)
   Worst Polarity          Horizontal     Vertical

                     Radiated Emission Measurement Below 1G
  Test Condition                       Radiated Emission Below 1G
Power supply Mode Mode 1: EUT power by host system (DC 5V)
    Worst Mode             Mode 1      Mode 2       Mode 3       Mode 4

Remark:
1. The worst mode was record in this test report.
2. EUT pre-scanned in three axis, X, Y, Z and two polarity, Horizontal and Vertical for
radiated measurement. The worst case (X-Plane and Horizontal) were recorded in this
report


                                                                                        Page:    12 / 32
  Report No.: T190220D01-RP                                                              Rev.:   02

4. TEST RESULT
4.1 AC POWER LINE CONDUCTED EMISSION
4.1.1 Test Limit
According to §15.207(a) and RSS-GEN section 8.8,
           Frequency Range                                           Limits(dBμV)
                (MHz)                                        Quasi-peak           Average
             0.15 to 0.50                                     66 to 56*           56 to 46*
               0.50 to 5                                         56                  46
                5 to 30                                          60                  50
* Decreases with the logarithm of the frequency.


4.1.2 Test Procedure
1. The EUT was placed on a non-conducted table, which is 0.8m above horizontal
ground plane and 0.4m above vertical ground plane.
2. EUT connected to the line impedance stabilization network (LISN)
3. Receiver set RBW of 9kHz and Detector Peak, and note as quasi-peak and average.
4. Maximum procedure was performed on the six highest emissions to ensure EUT
compliance.
5. Recorded Line for Neutral and Line.


4.1.3 Test Setup
                           Vertical reference ground plane
                                                                         EMI receiver

          40c
          m        EUT



                                    80cm



   LISN                                    Horizontal reference ground
                                           plane




4.1.4 Test Result

Not applicable, because EUT not connect to AC Main Source direct.


                                                                          Page:    13 / 32
 Report No.: T190220D01-RP                                                 Rev.:   02

4.2 20dB BANDWIDTH AND OCCUPIED BANDWIDTH (99%)

TEST CONFIGURATION



   EUT                                           Spectrum
                                                 Analyzer




TEST PROCEDURE

  1. Place the EUT on the table and set it in the transmitting mode.
  2. SA set RBW = 1% ~ 5% OBW, VBW = three times the RBW and Detector = Peak,
     to measurement 99% Bandwidth and 20dB Bandwidth
  3. Measure and record the result of 20 dB Bandwidth and 99% Bandwidth. in the test
     report.


TEST RESULTS
No non-compliance noted

                                        Occupied Bandwidth        20 dB Bandwidth
Test Condition     Frequency(Hz)
                                            99% (MHz)                  (MHz)
  24G Radar               24G                  211.866                 218.81


                              Page:    14 / 32
  Report No.: T190220D01-RP    Rev.:   02

Test Plot

20dB Bandwidth




Date: 3.APR.2019   09:29:32


BANDWIDTH (99%)




Date: 3.APR.2019   09:33:51


                                                                                Page:    15 / 32
  Report No.: T190220D01-RP                                                      Rev.:   02

4.3 FIELD STRENGTH OF FUNDAMENTAL AND RADIATION
      SPURIOUS EMISSION
4.3.1 Test Limit
FCC according to §15.249(a).
(1) The field strength of emissions from intentional radiators operated within these
frequency bands shall comply with the following:
          Fundamental                        Field strength of     Field strength of
           frequency                           fundamental            harmonics
             (MHz)                           (millivolts/meter)   (microvolts/meter)
         2400-2483.5                                  50                  500
          5725-5875                                   50                  500
         24000-24250                                 250                 2500
* Field strength limits are specified at a distance of 3 meters

                                   Fundamental Limit Conversion
       Average                    Average              Average              Peak
       (mV/m)                    (dBuV/m)             (dBuV/m)            (dBuV/m)
        at 3M                      at 3M                at 1M               at 1M
         250                     107.9588              117.50              137.50
*(Limit=107.9588+20LOG(3/1)=117.50 dBuV/m)

                                     Harmonic Limit Conversion
       Average                    Average              Average              Peak
        (uV/m)                   (dBuV/m)             (dBuV/m)            (dBuV/m)
         at 3M                     at 3M                at 1M               at 1M
         2500                     67.9588               77.50               97.50
*(Limit=67.9588+20LOG(3/1)=77.50 dBuV/m)


                                                                               Page:    16 / 32
  Report No.: T190220D01-RP                                                     Rev.:   02


(2) Emissions radiated outside of the specified frequency bands, except for harmonics,
shall be attenuated by at least 50 dB below the level of the fundamental or to the general
radiated emission limits in §15.209(follow the table), whichever is the lesser attenuation
Below 30 MHz
                                                                         Measurement
                        Field Strength      Magnetic field strength
    Frequency                                                              Distance
                            (µA/m)             (H-Field) (µA/m)
                                                                           (metres)
     9-490 kHz        2,400/F (F in kHz)       2,400/F (F in kHz)            300
   490-1,705 kHz      24,000/F (F in kHz)     24,000/F (F in kHz)             30
   1.705-30 MHz               30                      N/A                     30

Above 30 MHz
                                                  Field Strength
      Frequency                       microvolts/m at 3 metres (watts, e.i.r.p.)
        (MHz)
                                    Transmitters                       Receivers
         30-88                       100 (3 nW)                       100 (3 nW)
        88-216                      150 (6.8 nW)                      150 (6.8 nW)
        216-960                     200 (12 nW)                       200 (12 nW)
      Above 960                     500 (75 nW)                       500 (75 nW)


                                                                          Page:    17 / 32
 Report No.: T190220D01-RP                                                 Rev.:   02


IC according to RSS-Gen, Section 8.9 and 8.10.
RSS-Gen Table 3 and Table 5 – General Field Strength Limits for Transmitters and
Receivers at Frequencies Above 30 MHz (Note)
                                              Field Strength
     Frequency                   microvolts/m at 3 metres (watts, e.i.r.p.)
       (MHz)
                                 Transmitters                   Receivers
        30-88                     100 (3 nW)                    100 (3 nW)
        88-216                     150 (6.8 nW)                   150 (6.8 nW)
       216-960                     200 (12 nW)                    200 (12 nW)
      Above 960                    500 (75 nW)                    500 (75 nW)
Note: Measurements for compliance with the limits in table 3 may be performed at
distances other than 3 metres, in accordance with Section 6.6.

RSS-Gen Table 6: General Field Strength Limits for Transmitters at Frequencies
Below 30 MHz (Transmit)
                                Magnetic field strength     Measurement Distance
        Frequency
                                    (H-Field) (µA/m)                  (m)
       9-490 kHz Note               6.37/F (F in kHz)                 300
       490-1,705 kHz                63.7/F (F in kHz)                  30
       1.705-30 MHz                       0.08                         30
Note: The emission limits for the ranges 9-90 kHz and 110-490 kHz are based on
measurements employing a linear average detector..


                                                                                 Page:    18 / 32
        Report No.: T190220D01-RP                                                 Rev.:   02


      4.3.2 Test Procedure
      1. The EUT is placed on a turntable, Above 1 GHz is 1.5m, below 1 GHz and above 40G
      is 0.8m above ground plane. The EUT Configured un accordance with ANSI C63.10:
      2013, and the EUT set in a continuous mode.
      2. The turntable shall be rotated for 360 degrees to determine the position of maximum
      emission level. And EUT is set 3m away from the receiving antenna, which is scanned
      from 1m to 4m above the ground plane to find out the highest emissions. Measurement
      are made polarized in both the vertical and the horizontal positions with antenna.
      3. The measurement distance above 40 GHz is set 1m away from the receiving antenna.
      4. The SA setting following:
        (1) Below 1G:RBW = 100kHz, VBW ≥ 3 RBW, Sweep = Auto, Detector = Peak,
        (2) Above 1G:
           (2.1) For Peak measurement:RBW = 1MHz, VBW ≥ 3 RBW.
           (2.2) For Average measurement:RBW = 1MHz, VBW = 10Hz.


For measurements above 40 GHz, every attempt shall be made to reduce contributions from
reflections to a minimum. Measurements in the frequency range above 40 GHz are typically
made at a closer distance because the instrumentation noise floor is typically close to
the radiated emission limit. Use of waveguide and flexible waveguide might be necessary
at frequencies above 40 GHz to achieve usable signal-to-noise ratios at required
measurement distances.The corrected system noise floor level is 6 dB or more below
the limit, then the validated maximum measurement distance is the distance specified
by the limit.
This devices that cause emissions above 10 GHz are physically small compared with
the beamwidths of typical horn antennas used for EMC measurements. For such EUTs
and frequencies above 40 GHz,, it might be preferable to vary the height and
polarization of the EUT, instead of the receiving antenna, to maximize the measured emissions.


                                                               Page:    19 / 32
 Report No.: T190220D01-RP                                      Rev.:   02




4.3.3 Test Setup

9kHz ~ 30MHz




                             3m
                                                Loop antenna
       EUT

                                              Spectrum /
                                               Receiver


             Turntable                  1m
                            0.8m




   Reference ground plane


30MHz ~ 1GHz

                                              Antenna
                                               tower


                             3m                Bi-log
                                              antenna
       EUT
                                   4m
                                             Spectrum
                                             analyzer


             Turntable                  1m
                            0.8m




   Reference ground plane


                                                   Page:    20 / 32
 Report No.: T190220D01-RP                          Rev.:   02




Above 1 GHz

                                       Antenna
                                        tower


                     3m                Horn
                                      antenna
  EUT
                            4m
                                      Spectrum
                                      analyzer

        Turntable   1.5m
                                 1m
                                         Pre-amp
                           ▲▲▲
                       ▲▲▲



Above 40 GHz


                                                                          Page:        21 / 32
 Report No.: T190220D01-RP                                                 Rev.:       02



4.3.4 Test Result

              Peak      Average         Peak          Average               Antenna
  Freq.
              Value      Value          Limit          Limit     Result    Polarization
  (GHz)
            (dBuV/m)   (dBuV/m)       (dBuV/m)       (dBuV/m)                 (V/H)
 24107.50    96.87       81.69         128.00         108.00     Pass              H
 24195.00    94.78       69.78         128.00         108.00     Pass              V

Test Data
(1) Filed strength of fundamental :
   Test Mode:             TX-24GHz                Temp/Hum       23(℃)/ 66%RH
    Test Item            Fundamental               Test Date     March 06, 2019
      Axis                 X-Plane               Test Engineer     Dally Hong
    Detector            Peak & Average             Horizontal


                                                          Page:    22 / 32
Report No.: T190220D01-RP                                  Rev.:   02




 Test Mode:          TX-24GHz        Temp/Hum       23(℃)/ 66%RH
  Test Item         Fundamental       Test Date     March 06, 2019
  Polarize            Vertical      Test Engineer     Dally Hong
  Detector         Peak & Average      Vertical


                                                                                Page:     23 / 35
  Report No.: T190220D01-RP                                                      Rev.:    00




(2) Band Edge Test Data
    Test Mode:                   24 GHz               Temp/Hum           23(℃)/ 66%RH
     Test Item                  Band Edge              Test Date         March 06, 2019
     Polarize                    Vertical            Test Engineer         Dally Hong




     No.   Frequency   Reading      Correct       Result     Limit     Margin   Remark
             (MHz)     (dBuV)     Factor(dB/m)   (dBuV/m)   (dBuV/m)    (dB)
     1     24000.00     34.65        17.09        51.74      54.00     -2.26    Average
     2     24000.00     42.37        17.09        59.46      74.00     -14.54    Peak


                                                                               Page:     24 / 32
Report No.: T190220D01-RP                                                       Rev.:    02




  Test Mode:                   24 GHz                Temp/Hum           23(℃)/ 66%RH
   Test Item                  Band Edge               Test Date         March 06, 2019
   Polarize                   Horizontal            Test Engineer         Dally Hong




   No.   Frequency   Reading       Correct       Result     Limit     Margin   Remark
           (MHz)     (dBuV)      Factor(dB/m)   (dBuV/m)   (dBuV/m)    (dB)
   1     24000.00     34.62         17.09        51.71      54.00     -2.29    Average
   2     24000.00     43.80         17.09        60.89      74.00     -13.11    Peak


                                                                       Page:    25 / 32
 Report No.: T190220D01-RP                                              Rev.:   02

(3) Below 1G:
   Test Mode:            TX-24GHz              Temp/Hum        23(℃)/ 66%RH
    Test Item          30MHz-1GHz               Test Date      March 06, 2019
    Polarize               Vertical           Test Engineer      Dally Hong
    Detector         Peak and Qusi-peak




                           Correct
   Frequency    Reading                Result        Limit    Margin
                           Factor                                         Remark
     (MHz)      (dBuV)               (dBuV/m)      (dBuV/m)    (dB)
                           (dB/m)

    59.10       35.34      -15.36     19.98          40.00    -20.02      Peak
    122.15      26.65      -8.25      18.40          43.50    -25.10      Peak
    424.79      27.19      -4.09      23.10          46.00    -22.90      Peak
    524.70      25.81      -1.31      24.50          46.00    -21.50      Peak
    638.19      24.75       0.86      25.61          46.00    -20.39      Peak
    833.16      25.38       4.45      29.83          46.00    -16.17      Peak


                                                                     Page:    26 / 32
Report No.: T190220D01-RP                                             Rev.:   02



 Test Mode:            TX-24GHz              Temp/Hum        23(℃)/ 66%RH
  Test Item          30MHz-1GHz               Test Date      March 06, 2019
  Polarize             Horizontal           Test Engineer      Dally Hong
  Detector         Peak and Qusi-peak




                         Correct
 Frequency    Reading                Result        Limit    Margin
                         Factor                                         Remark
   (MHz)      (dBuV)               (dBuV/m)      (dBuV/m)    (dB)
                         (dB/m)

  120.21      27.18      -8.33      18.85          43.50    -24.65      Peak
  173.56      31.09      -10.36     20.73          43.50    -22.77      Peak
  287.05      31.58      -7.70      23.88          46.00    -22.12      Peak
  500.45      26.36      -2.10      24.26          46.00    -21.74      Peak
  634.31      26.67       0.92      27.59          46.00    -18.41      Peak
  830.25      25.78       4.32      30.10          46.00    -15.90      Peak


                                                                               Page:    27 / 32
  Report No.: T190220D01-RP                                                     Rev.:   02

(4) Above 1G :
   Test Mode:                 TX-24GHz                 Temp/Hum       23(℃)/ 66%RH
    Test Item                1GHz-40GHz                 Test Date     March 06, 2019
    Polarize                    Vertical              Test Engineer     Dally Hong
    Detector               Peak and Average




                                Correct
   Frequency      Reading                   Result           Limit    Margin
                                Factor                                            Remark
     (MHz)        (dBuV)                  (dBuV/m)         (dBuV/m)    (dB)
                                (dB/m)
    1595.00        52.94         -7.18        45.76          74.00    -28.24       Peak
      N/A




Remark:
    1. For above 1GHz, the EUT peak value was under average limit, therefore the Average
        value compliance with the average limit


                                                                               Page:    28 / 32
  Report No.: T190220D01-RP                                                     Rev.:   02



    Test Mode:                TX-24GHz                 Temp/Hum        23(℃)/ 66%RH
     Test Item               1GHz-40GHz                 Test Date      March 06, 2019
     Polarize                 Horizontal              Test Engineer      Dally Hong
     Detector              Peak and Average




                               Correct
   Frequency      Reading                   Result           Limit    Margin
                               Factor                                             Remark
     (MHz)        (dBuV)                  (dBuV/m)         (dBuV/m)    (dB)
                               (dB/m)
    1595.00        55.98        -7.18         48.80         74.00     -25.20       Peak
      N/A




Remark:
    1. For above 1GHz, the EUT peak value was under average limit, therefore the Average
        value compliance with the average limit


                                                                       Page:    29 / 32
 Report No.: T190220D01-RP                                              Rev.:   02




   Test Mode:             TX-24GHz             Temp/Hum          23(℃)/ 66%RH
    Test Item          40GHz-50GHz              Test Date        March 06, 2019
    Polarize          Vertical/Horizontal     Test Engineer        Dally Hong
    Detector          Peak and Average




Remark:
    1. For above 1GHz, the EUT peak value was under average limit, therefore the
        Average value compliance with the average limit


                                                                       Page:    30 / 32
 Report No.: T190220D01-RP                                              Rev.:   02



   Test Mode:             TX-24GHz             Temp/Hum          23(℃)/ 66%RH
    Test Item          50GHz-75GHz              Test Date        March 06, 2019
    Polarize          Vertical/Horizontal     Test Engineer        Dally Hong
    Detector          Peak and Average




Remark:
    1. For above 1GHz, the EUT peak value was under average limit, therefore the
        Average value compliance with the average limit


                                                                       Page:    31 / 32
 Report No.: T190220D01-RP                                              Rev.:   02



   Test Mode:             TX-24GHz             Temp/Hum          23(℃)/ 66%RH
    Test Item          75GHz-90GHz              Test Date        March 07, 2019
    Polarize          Vertical/Horizontal     Test Engineer        Dally Hong
    Detector          Peak and Average




Remark:
    1. For above 1GHz, the EUT peak value was under average limit, therefore the
        Average value compliance with the average limit


                                                                       Page:    32 / 32
 Report No.: T190220D01-RP                                              Rev.:   02



   Test Mode:             TX-24GHz             Temp/Hum          23(℃)/ 66%RH
    Test Item          90GHz-100GHz             Test Date        March 07, 2019
    Polarize          Vertical/Horizontal     Test Engineer        Dally Hong
    Detector          Peak and Average




Remark:
    1. For above 1GHz, the EUT peak value was under average limit, therefore the
        Average value compliance with the average limit


                                 --End of Report--