RF Exposure Info

FCC ID: N82-KOHLER034

RF Exposure Info

Download: PDF
FCCID_4416393

                                                              SGS-CSTC Standards Technical Services Co., Ltd.
                                                              Shanghai Branch

   588 West Jindu Road, Xinqiao, Songjiang, 201612 Shanghai, China
   Telephone:   +86 (0) 21 6191 5666                                                                                            Report No.: SHEM181200000204
   Fax:         +86 (0) 21 6191 5678
   ee.shanghai@sgs.com
                                                                                                                                Page:        1 of 8




   1          Cover Page
                                                               RF MPE REPORT
   Application No.:                               SHEM1812000002CR
   Applicant:                                     Kohler Co.
   FCC:                                           N82-KOHLER034
   IC ID:                                         4554A-KOHLER034
   Equipment Under Test (EUT):
   NOTE: The following sample(s) was/were submitted and identified by the client as
   Product Name:                                  Eir Intelligent Remote Control

   Model No.(EUT):                                1377073

   Trade mark:                                    KOHLER
   Standards:                                     RSS-102 Issue 5 (March 2015)
   Date of Receipt:                               2018-12-18

   Date of Test:                                  2018-12-18 to 2018-12-25

   Date of Issue:                                 2019-04-08

   Test Result:                                   Pass*

   *           In the configuration tested, the EUT complied with the standards specified above.




                      Parlam Zhan
                   E&E Section Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this
report. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure
the new system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS
International Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by
SGS International Electrical Approvals in writing.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and,
for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the
limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time
of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.


                                      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                                      Branch
                                                                                               Report No.: SHEM181200000204
                                                                                               Page:       2 of 8




                                                                     Revision Record
               Version                     Description                                     Date                                      Remark

                   00                          Original                               2019-04-10                                            /




          Authorized for issue
          by:




                                                            Vincent Zhu / Project Engineer




                                                            Parlam Zhan / Reviewer




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only


                                      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                                      Branch
                                                                                                Report No.: SHEM181200000204
                                                                                                Page:       3 of 8




2         Contents
                                                                                                                                                                 Page
1       COVER PAGE ................................................................................................................................................. 1
2       CONTENTS ..................................................................................................................................................... 3
3       GENERAL INFORMATION ......................................................................................................................... 4
    3.1     CLIENT INFORMATION.................................................................................................................................... 4
    3.1     GENERAL DESCRIPTION OF E.U.T. ................................................................................................................. 4
    3.2     TECHNICAL SPECIFICATIONS .......................................................................................................................... 4
    3.3     TEST LOCATION ............................................................................................................................................. 5
    3.4     TEST FACILITY ............................................................................................................................................... 5
4       TEST STANDARDS AND LIMITS ............................................................................................................... 6
    4.1     IC RADIOFREQUENCY RADIATION EXPOSURE LIMITS:..................................................................................... 6
5       MEASUREMENT AND CALCULATION ................................................................................................... 7
    5.1     MAXIMUM TRANSMIT POWER ........................................................................................................................ 7
    5.2     MPE CALCULATION....................................................................................................................................... 8




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only


                                      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                                      Branch
                                                                                               Report No.: SHEM181200000204
                                                                                               Page:       4 of 8




3        General Information

3.1 Client Information
           Applicant:                                       Kohler Co.
           Address of Applicant:                            444 Highland Drive KOHLER, WI 53044
           Manufacturer:                                    Shanghai Kohler Electronics., Ltd.
           Address of Manufacturer:                         No. 1955, Fengxiang Road, Baoshan Area, Shanghai, PRC Post
                                                            code: 200444
           Factory:                                         Shanghai Kohler Electronics., Ltd.
           Address of Factory:                              No. 1955, Fengxiang Road, Baoshan Area, Shanghai, PRC Post
                                                            code: 200444

3.1 General Description of E.U.T.
         Power supply:                                      Remote: DC 3.7V 400mAh Li-on rechargeable battery
                                                            Charger: DC 6V by 4*AA size batteries
         Test voltage:                                      DC 3.7V

3.2 Technical Specifications
2.4GHz:
         Modulation Type                                    MSK
         Number of Channels                                 8
         Operation Frequency                                2414.5MHz~2449.5MHz
         Channel Spacing                                    5MHz
         Antenna Type:                                      PCB Antenna
         Antenna Gain:                                      2.88 dBi
         Modulation Type                                    MSK




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only


                                      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                                      Branch
                                                                                               Report No.: SHEM181200000204
                                                                                               Page:       5 of 8




3.3 Test Location
          All tests were performed at:
          SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. E&E Lab
          588 West Jindu Road, Xinqiao, Songjiang, 201612 Shanghai, China
          Tel: +86 21 6191 5666        Fax: +86 21 6191 5678
          No tests were sub-contracted.

3.4 Test Facility
           The test facility is recognized, certified, or accredited by the following organizations:
             • CNAS (No. CNAS L0599)
           CNAS has accredited SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. to ISO/IEC
           17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories
           (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration Laboratories) for
           the competence in the field of testing.
            • NVLAP (Certificate No. 201034-0)
           SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. is accredited by the National Voluntary
           Laboratory Accreditation Program(NVLAP). Certificate No. 201034-0.
            • FCC –Designation Number: CN5033
           SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. has been recognized as an accredited
           testing laboratory.
           Designation Number: CN5033. Test Firm Registration Number: 479755.
            • Industry Canada (IC) – IC Assigned Code: 8617A
           The 3m Semi-anechoic chamber of SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
           has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment
           testing with Registration No.: 8617A-1. CAB identifier: CN0020.
            • VCCI (Member No.: 3061)
           The 3m Semi-anechoic chamber and Shielded Room of SGS-CSTC Standards Technical Services
           (Shanghai) Co., Ltd. has been registered in accordance with the Regulations for Voluntary Control
           Measures with Registration No.: R-13868, C-14336, T-12221, G-10830 respectively.




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only


                                      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                                      Branch
                                                                                               Report No.: SHEM181200000204
                                                                                               Page:       6 of 8




4         Test Standards and Limits

4.1 IC Radiofrequency radiation exposure limits:
According RSS-102 Table 4(RF Field Strength Limits for Devices Used by the General Public)


      Frequency Range                   Electric Field               Magnetic Field                  Power Density                   Reference Period
             (MHz)                         (V/m rms)                      (A/m rms)                         (W/m2)                          (minutes)
           0.003-10                              83                             90                               -                      Instantaneous*
             0.1-10                                -                        0.73/ ƒ                              -                                6**
             1.1-10                          87/ ƒ 0.5                           -                               -                                6**
              10-20                            27.46                        0.0728                              -2                                 6
              20-48                        58.07/ ƒ0.25                 0.1540/ ƒ0.25                     8.944/ ƒ0.5                              6
             48-300                            22.06                       0.05852                           1.291                                 6
           300-6000                      3.142 ƒ 0.3417              0.008335 ƒ 0.3417                0.02619 ƒ 0.6834                             6
          6000-15000                            61.4                         0.163                              10                                 6
        15000-150000                            61.4                         0.163                              10                        616000/ ƒ 1.2
        150000-300000                      0.158 ƒ 0.5                4.21 x 10-4 ƒ 0.5                 6.67 x 10-5 ƒ                      616000/ƒ1.2
Note: ƒ is frequency in MHz.
*    Based on nerve stimulation (NS).
**   Based on specific absorption rate (SAR).

For 2.4GHz Devices RF Field Strength Limits is 45V/m




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only


                                      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                                      Branch
                                                                                               Report No.: SHEM181200000204
                                                                                               Page:       7 of 8




5        Measurement and Calculation

5.1 Maximum transmit power
                          Read                                                         Limit                 Over
Frequency                                    Factor              Level
                          Level                                                        Line                  Limit            Detector             Polarization
  (MHz)                                      (dB/m)            (dBuV/m)
                         (dBuV)                                                      (dBuV/m)                (dB)
                           90.99               -8.15              82.84                    94               -11.16               Peak               Horizontal
    2414.5
                           86.76               -8.18              78.58                    94               -15.42               Peak                  Vertical

                          Read                                                         Limit                 Over
Frequency                                    Factor              Level
                          Level                                                        Line                  Limit            Detector             Polarization
  (MHz)                                      (dB/m)            (dBuV/m)
                         (dBuV)                                                      (dBuV/m)                (dB)
                           89.17               -8.17                 81                    94                  -13               Peak               Horizontal
    2434.5
                           86.56               -8.17              78.39                    94               -15.61               Peak                  Vertical

                          Read                                                         Limit                 Over
Frequency                                    Factor              Level
                          Level                                                        Line                  Limit            Detector             Polarization
  (MHz)                                      (dB/m)            (dBuV/m)
                         (dBuV)                                                      (dBuV/m)                (dB)
                           90.34               -8.18              82.16                    94               -11.84               Peak               Horizontal
    2449.5
                           85.94               -8.15              77.79                    94               -16.21               Peak                  Vertical




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only


                                      SGS-CSTC Standards Technical Services Co., Ltd. Shanghai
                                      Branch
                                                                                               Report No.: SHEM181200000204
                                                                                               Page:       8 of 8




5.2 MPE Calculation
The max Field Strength is 82.84 dBuV/m=0.0139V/m<45V/m

So the device is exclusion from SAR test.


                                                              --End of the Report--




 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at
www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this
document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights
and obligations under the transaction
documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results
shown in this test report refer only to thesample(s) tested and such sample(s) are retained for 90 days only