EXHIBIT 12.                LOW THRESHOLD CALCULATIONS

Frequency Range: 2402-2480MHz

Low threshold = 60/f(GHz) mW = 60 / 2.480 = 24.19mW

Conducted Output Power Measured (dBm) = 10.21 dBm

Antenna Gain (dBi) = -2.01 dBi

EIRP = 6.61 mW
Conducted Output Power (mW) = 10.495 mW

Since both Conducted output power and EIRP are below the low threshold, device complies with FCC’s RF
radiation exposure limits for general population/uncontrolled exposure category for a portable device without SAR
evaluation.




Prepared For: Kohler, CO              Model #:Fountain Head Bath Remote                       LS Research, LLC
EUT: 2.4 GHz Remote                   Serial #: 07420550                   Template: 15.247 DTS TX (V2 9-06-06)
Report #: 307434 TX                   Customer FCC ID #: n/a                                      Page 34 of 35



Document Created: 2008-08-28 12:01:09