RF Exposure_Q2698_03

FCC ID: N7NQ2698

RF Exposure Info

Download: PDF
FCCID_1787523

Evaluation of RF Exposure for Q2698 Wireless Modem as a Mobile Device

In this application we seek modular approval to the Q2698 wireless modem for use in mobile
configuration.

Part I: FCC requirement
Based on the FCC OET Bulletin 65 Supplement C and 47 CFR §2.1091, we have concluded that
the Q2698 will comply with the FCC rules on RF exposure for mobile devices if the antenna gain
does not exceed 7.5 dBi in cellular band and 3.5 dBi in PCS band. The following analysis will
demonstrate such compliance. The analysis will be done in two US bands.

Operation in cellular band (824 – 849 MHz)

The peak conducted output power of Q2698 in Cellular band is 32.65 dBm. Take the worst case
as an example, in which an antenna with 7.5 dBi gain is used. The resulted power density at a
distance of 20 cm can be deducted as follows:

        EIRP = Pcond + 7.5
        Power Density = EIRP*DutyCycle/(4πR2)

The table below shows the different MPE levels in different time slot configurations:

                   Max Pcond Max EIRP Max EIRP Dute Cycle
                   (dBm)      (dBm)     (mW)              MPE (mW/ cm2)
    1 Time Slot         32.44     39.94   9862.79   12.5%           0.245
    2 Time Slots        32.65     40.15  10351.42     25%           0.515
    3 Time Slots           30      37.5   5623.41   37.5%           0.420
    4 Time Slots           29      36.5   4466.84     50%           0.444

The MPE limit for General Population/Uncontrolled Exposure is shown in the FCC OET Bulletin
65 Supplement C and can be calculated as follows:

        MPE limit = 824/1500 = 0.55 mW/cm2

As we can see the resulted power density is below the MPE limit, therefore Q2698 in Cellular
band is compliant with the FCC rules on RF exposure.

Operation in PCS band (1850 – 1910 MHz)

The peak conducted output power of Q2698 in PCS band is 29.4 dBm. Take the worst case as an
example, in which an antenna with 3.5 dBi gain is used. The resulted ERP can be expressed as
follows:

        ERP = 29.4 + 3.5 –2.15 = 30.75 dBm (1.19 W) < 3 W

The FCC OET Bulletin 65 Supplement C states that mobile devices identified in 47 CFR §2.1091
that operate at frequencies above 1.5 GHz with an ERP of 3.0 watts or more are required to


perform routine environmental evaluation for RF exposure prior to equipment authorization or
use; otherwise, they are categorically excluded.

As we can see this resulted ERP is below 3 W, therefore routine environmental evaluation for RF
exposure prior to equipment authorization or use for Q2698 in PCS band is categorically
excluded.

Part II: IC requirement

Power Density= 0.515m W/cm2 =5.15W/ m2 (Worse case) When operate in cellular band (824 –
849 MHz) if the device antenna gain does not exceed 7.5 dBi in cellular band.

Power Density= 0.095m W/cm2 =0.95W/ m2 (Worse case) When operate in PCS band (1850 –
1910 MHz) if the device antenna gain does not exceed 3.5 dBi in PCS band. The table below
shows the different MPE levels in different time slot configurations:

                       Max Pcond Max EIRP Max EIRP Dute Cycle
                       (dBm)      (dBm)     (mW)              MPE (mW/ cm2)
    1 Time Slot              29.4      32.9   1949.84   12.5%           0.048
    2 Time Slots             29.3      32.8   1905.46     25%           0.095
    3 Time Slots              27       30.5   1122.02   37.5%           0.084
    4 Time Slots              25       28.5    707.95     50%           0.070

AS IC RSS-102 requirement, RF Field Strength Limits for Devices Used by the General Public
(Uncontrolled Environment) listed below:

 Frequency Range        Electric Field (V/m Magnetic Field (A/m                Power Density       Averaging Time
                                                                                       2
      (MHz)                     rms)               rms)                          (W/ m )             (minutes)
0.003-1                 280                    2.19                        -                   6
1-10                    280/f                  2.19/f                      -                   6
10-30                   28                     2.19/f                      -                   6
30-300                  28                     0.073                       2*                  6
300-1500                1.585 f 0.5            0.0042 f 0.5                f/150               6
1500-15000              61.4                   0.163                       10                  6
15000-150000            61.4                   0.163                       10                  616000/f 1.2
150000-300000           0.158 f 0.5            4.21 x 10-4 f 0.5           6.67 x 10-5 f       616000/f 1.2

Note: f is frequency in MHz.
* Power density limit is applicable at frequencies greater than 100 MHz.

The RF Field Strength limit for General Population/Uncontrolled Exposure is shown in the RSS-
102 and can be calculated as follows:

          Cellular band limit = 824/150 = 5.5 W/m2
          PCS band limit =10W/ m2

As we can see the resulted power density is below the MPE limit, therefore Q2698 is compliant
with the IC rules on RF exposure.



Document Created: 2012-08-14 10:11:57
Document Modified: 2012-08-14 10:11:57

© 2024 FCC.report