SAR Plots CDMA 850

FCC ID: N7NGOBI2

RF Exposure Info

Download: PDF
FCCID_1481912

                                                                                          Date/Time: 5/12/2011 5:22:01 PM

Test Laboratory: UL CCS


1_Lap-held
DUT: Panasonic; Type: Tablet; Serial: 1BKKSA00017

Communication System: CDMA Cell Band for Palm; Frequency: 836.52 MHz; Duty Cycle: 1:1
                                                                                                   3
Medium parameters used (interpolated): f = 836.52 MHz; s = 0.961 mho/m; er = 53.037; ? = 1000 kg/m
Phantom section: Flat Section

Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C

DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3686; ConvF(8.78, 8.78, 8.78); Calibrated: 1/24/2011
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1239; Calibrated: 11/17/2010
- Phantom: ELI 4.0; Type: QDOVA001BB; Serial: 1099
- Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595)


CDMA2000/Cell_RC3, SO32_CH384/Area Scan (11x15x1):                              Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.052 mW/g

CDMA2000/Cell_RC3, SO32_CH384/Zoom Scan (7x7x9)/Cube 0:                                  Measurement grid: dx=5mm,
dy=5mm, dz=3mm
Reference Value = 5.469 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 0.068 W/kg
SAR(1 g) = 0.044 mW/g; SAR(10 g) = 0.030 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.053 mW/g


                                                                                          Date/Time: 5/13/2011 6:11:35 PM

Test Laboratory: UL CCS


4_Bottom Face
DUT: Panasonic ; Type: Tablet; Serial: 1BKKSA00017

Communication System: CDMA Cell Band; Frequency: 836.52 MHz; Duty Cycle: 1:1
                                                                                                   3
Medium parameters used (interpolated): f = 836.52 MHz; s = 0.958 mho/m; er = 53.772; ? = 1000 kg/m
Phantom section: Flat Section

Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C

DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3686; ConvF(8.78, 8.78, 8.78); Calibrated: 1/24/2011
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1239; Calibrated: 11/17/2010
- Phantom: ELI 4.0; Type: QDOVA001BB; Serial: 1099
- Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595)


CDMA2000/Cell_RC3, SO32_CH384/Area Scan (11x12x1):                              Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.215 mW/g

CDMA2000/Cell_RC3, SO32_CH384/Zoom Scan (7x7x9)/Cube 0:                                  Measurement grid: dx=5mm,
dy=5mm, dz=3mm
Reference Value = 14.930 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 0.286 W/kg
SAR(1 g) = 0.185 mW/g; SAR(10 g) = 0.126 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.225 mW/g


                                                                                        Date/Time: 5/13/2011 10:37:37 PM

Test Laboratory: UL CCS


5_Secondary Landscape
DUT: Panasonic ; Type: Tablet; Serial: 1BKKSA00017

Communication System: CDMA Cell Band for Palm; Frequency: 836.52 MHz; Duty Cycle: 1:1
                                                                                                   3
Medium parameters used (interpolated): f = 836.52 MHz; s = 0.958 mho/m; er = 53.772; ? = 1000 kg/m
Phantom section: Flat Section

Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C

DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3686; ConvF(8.78, 8.78, 8.78); Calibrated: 1/24/2011
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn1239; Calibrated: 11/17/2010
- Phantom: ELI 4.0; Type: QDOVA001BB; Serial: 1099
- Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595)


CDMA2000/Cell_RC3, SO32_CH384/Area Scan (8x14x1):                             Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.303 mW/g

CDMA2000/Cell_RC3, SO32_CH384/Zoom Scan (7x7x9)/Cube 0:                                  Measurement grid: dx=5mm,
dy=5mm, dz=3mm
Reference Value = 17.968 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 0.464 W/kg
SAR(1 g) = 0.262 mW/g; SAR(10 g) = 0.159 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.339 mW/g



Document Created: 2011-05-19 08:50:00
Document Modified: 2011-05-19 08:50:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC