SAR Report

FCC ID: N7NGOBI2

RF Exposure Info

Download: PDF
FCCID_1481906

  FCC OET BULLETIN 65 SUPPLEMENT C 01-01
            IEEE STD 1528:2003

          SAR EVALUATION REPORT


                      For
        Gobi2000 PCI Express Mini Card
  (Tested inside of Panasonic Tablet PC CF-C1)

          MODEL NUMBER: GOBI2000
             FCC ID: N7NGOBI2



        REPORT NUMBER: 11J13758-1

           ISSUE DATE: May 19, 2011


                  Prepared for
PANASONIC CORPORATION OF NORTH AMERICA.
        ONE PANASONIC WAY, 4B-8
        SECAUCUS, NJ 07094, U.S.A


                  Prepared by
COMPLIANCE CERTIFICATION SERVICES (UL CCS)
          47173 BENICIA STREET
        FREMONT, CA 94538, U.S.A.
            TEL: (510) 771-1000
            FAX: (510) 661-0888


REPORT NO: 11J13758-1                                                                   DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                        IC ID: 2417C-GOBI2

                                             Revision History


 Rev.     Issue Date                Revisions                                             Revised By
 --       May 19, 2011              Initial Issue                                         --




                                          Page 2 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                         FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                    TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                                                              DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                                                                   IC ID: 2417C-GOBI2

                                                        TABLE OF CONTENTS
1.     ATTESTATION OF TEST RESULTS ............................................................................................... 4

2.     TEST METHODOLOGY ................................................................................................................... 5

3.     FACILITIES AND ACCREDITATION ............................................................................................... 5

4.     CALIBRATION AND UNCERTAINTY .............................................................................................. 6
     4.1.      MEASURING INSTRUMENT CALIBRATION ............................................................................ 6
     4.2.      MEASUREMENT UNCERTAINTY ............................................................................................. 7

5.     EQUIPMENT UNDER TEST ............................................................................................................. 8

6.     SYSTEM SPECIFICATIONS ............................................................................................................ 9

7.     COMPOSITION OF INGREDIENTS FOR TISSUE SIMULATING LIQUIDS ................................... 10

8.     TISSUE DIELECTRIC PARAMETERS CHECK ............................................................................. 11
     8.1.      LIQUID CHECK RESULTS ...................................................................................................... 12

SYSTEM VERIFICATION ...................................................................................................................... 17
     8.2.      SYSTEM CHECK RESULTS ................................................................................................... 17

9.     SAR MEASUREMENT PROCEDURES ......................................................................................... 18

10.         RF OUTPUT POWER VERIFICATION ....................................................................................... 19
     10.1.        GSM ..................................................................................................................................... 19
     10.2.        UMTS RELEASE 99 ............................................................................................................. 20
     10.3.        CDMA2000........................................................................................................................... 21

11.         SUMMARY OF TEST RESULT ................................................................................................... 22
     11.1.        GPRS 850 & 1900 ................................................................................................................ 23
     11.2.        UMTS BAND V & II .............................................................................................................. 24
     11.3.        CDMA2000 Cell & PCS Band ............................................................................................... 25

12.         ATTACHMENTS ......................................................................................................................... 30

13.         ANTENNA LOCATIONS AND SEPARATION DISTANCES ....................................................... 31

14.         TEST SETUP PHOTOS .............................................................................................................. 33




                                          Page 3 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                                                        FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                                                   TEL: (510) 771-1000   FAX: (510) 661-0888
             This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                   DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                        IC ID: 2417C-GOBI2

1. ATTESTATION OF TEST RESULTS
 Applicant name:         PANASONIC CORPORATION OF NORTH AMERICA.
                         ONE PANASONIC WAY, 4B-8
                         SECAUCUS, NJ 07094, U.S.A
 EUT description:        The EUT is the Sierra Wireless Gobi2000
                         850/1900 GSM/WCDMA/GPRS/EDGE/CDMA Module
                         (Tested inside of Panasonic Tablet PC, Model CF-C1)
 Model number:           GOBI2000
 Device category:        Portable
 Exposure category:      General Population/Uncontrolled Exposure
 Date tested:            May 11 - 17, 2011
                          Freq. Range                                                             Limit
 FCC / IC Rule Parts                                   Highest 1-g SAR (mW/g)
                             [MHz]                                                               (mW/g)
                                             0.261 mW/g (UMTS)
   22H / RSS-132            824 - 849
                                             Tablet Mode – Secondary Landscape
                                                                                                      1.6
                                             0.625 mW/g (CDMA2000)
   24E / RSS-133          1850 - 1910
                                             Tablet Mode – Secondary Landscape
                                                                                                  Test
                                    Applicable Standards
                                                                                                 Results
 OET Bulletin 65 Supplement C 01-01,
                                                                                                     Pass
 IEEE STD 1528: 2003
 Compliance Certification Services, Inc. (UL CCS) tested the above equipment in accordance with the
 requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions
 expressed by UL CCS based on interpretations and/or observations of test results. Measurement
 Uncertainties were not taken into account and are published for informational purposes only. The test
 results show that the equipment tested is capable of demonstrating compliance with the requirements
 as documented in this report.
 Note: The results documented in this report apply only to the tested sample, under the conditions and
 modes of operation as described herein. This document may not be altered or revised in any way
 unless done so by UL CCS and all revisions are duly noted in the revisions section. Any alteration of
 this document not carried out by UL CCS will constitute fraud and shall nullify the document. This
 report must not be used by the client to claim product certification, approval, or endorsement by
 NVLAP, NIST, any agency of the Federal Government, or any agency of any government (NIST
 Handbook 150, Annex A). This report is written to support regulatory compliance of the applicable
 standards stated above.
 Approved & Released For CCS By:                       Tested By:



 Sunny Shih                                           Hung Thai
 Engineering Team Leader                              RF Engineer
 Compliance Certification Services (UL CCS)           Compliance Certification Services (UL CCS)




                                          Page 4 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                         FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                    TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                   DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                        IC ID: 2417C-GOBI2


2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with FCC OET Bulletin 65
Supplement C Edition 01-01, IEEE STD 1528:2003, and the following KDB Procedures.

-   248227 SAR measurement procedures for 802.11a/b/g transmitters
-   447498 D01 Mobile Portable RF Exposure v04

3. FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 47173 Benicia Street,
Fremont, California, USA.
UL CCS is accredited by NVLAP, Laboratory Code 200065-0. The full scope of accreditation can be
viewed at http://www.ccsemc.com




                                          Page 5 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                         FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                    TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                    DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                         IC ID: 2417C-GOBI2

4. CALIBRATION AND UNCERTAINTY
     4.1.      MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been calibrated in
accordance with the manufacturer's recommendations, and is traceable to recognized national
standards.
                                                                                        Cal. Due date
Name of Equipment                  Manufacturer     Type/Model       Serial No.
                                                                              MM DD              Year
Robot - Six Axes                     Stäubli            TX90         C01209               N/A
Robot Remote Control                 Stäubli           CS8C            N/A                N/A
DASY5 Measurement Server             SPEAG         SEUMS014AA          1064               N/A
Probe Alignment Unit                 SPEAG            LB5 / 80         N/A                N/A
SAM Phantom                          SPEAG         QP 000 P40 CC      1602                N/A
Oval Flat Phantom (ELI 4.0)          SPEAG         QD OVA001 B         1099               N/A
Dielectronic Probe kit                  HP            85070C           N/A                N/A
ESA Series Network Analyzer          Agilent          E5071B       MY42100131   8      2         2011
Synthesized Signal Generator            HP            83732B       US34490599   7    14          2012
Wireless comunication test set       Agilent       E5515C (8960)   GB46160222   6    17          2012
E-Field Probe                        SPEAG            EX3DV3          3686      1    23          2013
Data Acquisition Electronics         SPEAG             DAE 4           1239    11     17         2011
Thermometer                          ERTCO            639-1S           1718     7     19         2011
System Validation Dipole             SPEAG            D835V2          4d002     4      4         2012
System Validation Dipole             SPEAG           *D1900V2         5d043    11     24         2012
Power Meter                        Giga-tronics        8651A         8651404    3    13          2012
Power Sensor                       Giga-tronics       80701A         1834588    3     13         2012
Power Meter                         Boonton             4541          12405     4     5          2012
Power Sensor                        Boonton            57006           6940     3     31         2012
Amplifier                          Mini-Circuits     ZHL-42W        D072701-5             N/A
Simulating Liquid                    SPEAG           MSL1900           N/A    Within 24 hrs of first test
Simulating Liquid                    SPEAG            MSL835           N/A    Within 24 hrs of first test


*Note: Per KDB 450824 D02 requirements for dipole calibration, UL CCS has adopted two years
calibration intervals. On annual basis, each measurement dipole has been evaluated and is in
compliance with the following criteria:
1.    There is no physical damage on the dipole
2.    System validation with specific dipole is within 10% of calibrated value.
3.    Return-loss is within 20% of calibrated measurement ( test data on file in UL CCS)
4.    Impedance is within 5Ω of calibrated measurement (test data on file in UL CCS)




                                          Page 6 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                          FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                     TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                                   DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                                        IC ID: 2417C-GOBI2

   4.2.          MEASUREMENT UNCERTAINTY
Measurement uncertainty for 300 MHz to 3 GHz averaged over 1 gram
Component                                                           error, % Probe Distribution   Divisor Sensitivity U (Xi), %
Measurement System
Probe Calibration (k=1)                                                 5.50             Normal        1          1       5.50
Axial Isotropy                                                          1.15   Rectangular         1.732     0.7071       0.47
Hemispherical Isotropy                                                  2.30   Rectangular         1.732     0.7071       0.94
Boundary Effect                                                         0.90   Rectangular         1.732          1       0.52
Probe Linearity                                                         3.45   Rectangular         1.732          1       1.99
System Detection Limits                                                 1.00   Rectangular         1.732          1       0.58
Readout Electronics                                                     0.30             Normal        1          1       0.30
Response Time                                                           0.80   Rectangular         1.732          1       0.46
Integration Time                                                        2.60   Rectangular         1.732          1       1.50
RF Ambient Conditions - Noise                                           3.00   Rectangular         1.732          1       1.73
RF Ambient Conditions - Reflections                                     3.00   Rectangular         1.732          1       1.73
Probe Positioner Mechanical Tolerance                                   0.40   Rectangular         1.732          1       0.23
Probe Positioning with respect to Phantom                               2.90   Rectangular         1.732          1       1.67
Extrapolation, Interpolation and Integration                            1.00   Rectangular         1.732          1       0.58
Test Sample Related
Test Sample Positioning                                                 2.90           Normal          1           1      2.90
Device Holder Uncertainty                                               3.60           Normal          1           1      3.60
Output Power Variation - SAR Drift                                      5.00 Rectangular           1.732           1      2.89
Phantom and Tissue Parameters
Phantom Uncertainty (shape and thickness)                               4.00 Rectangular          1.732          1     2.31
Liquid Conductivity - deviation from target                             5.00 Rectangular          1.732       0.64     1.85
Liquid Conductivity - measurement (Body 1900 MHz)                       2.29             Normal        1      0.64     1.47
Liquid Permittivity - deviation from target                             5.00 Rectangular          1.732        0.6     1.73
Liquid Permittivity - measurement uncertainty (Body 850 MHz)           -3.89             Normal        1       0.6    -2.33
                                                                             Combined Standard Uncertainty Uc(y) =     9.83
                                       Expanded Uncertainty U, Coverage Factor = 2, > 95 % Confidence =   19.67    %
                                       Expanded Uncertainty U, Coverage Factor = 2, > 95 % Confidence =   1.56     dB




                                          Page 7 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                                  FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                             TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                  DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                       IC ID: 2417C-GOBI2

5. EQUIPMENT UNDER TEST
The EUT is the Sierra Wireless Gobi 2000 850/1900 for GSM/WCDMA/GPRS/EDGE/CDMA Module.
Tested inside Panasonic Tablet PC, CF-C1, SN: 1BKSA00017
Normal operation:             Laptop mode - with display open at 90° to the keyboard
                              Tablet mode - Multiple display orientations supporting both portrait and
                              landscape configurations.
Antenna tested:                Part number:
                               ANTENNA MAIN: DFUP1887ZA(1)
                               Manufactured by:
                               Panasonic Corporation Of North America
Antenna-to-antenna/user       See Section 13 for details of antenna locations and separation
separation distances:         distances.
Simultaneous transmission:    •   WWAN can transmit simultaneously with WiFi
                              •   WWAN can transmit simultaneously with Bluetooth
                              •   WiFi can transmit simultaneously with Bluetooth
Assessment for SAR            WiFi and BT
evaluation for Simultaneous   The Bluetooth’s maximum output power is ≤ 60/f(GHz) mW. Therefore
transmission:                 stand-alone SAR evaluation is not required. Additionally, simultaneous
                              transmission SAR evaluation is not required for WiFi/Bluetooth antenna
                              pair.
                              (Bluetooth - FCC ID: ACJ9TGBT11B; IC: 216A-CFBT11B)
                              WWAN and BT
                              Same as WiFi and BT
                              WWAN and WiFi
                              SAR is not required due to ∑ (SAR1g) < SAR limit.




                                          Page 8 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                        FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                   TEL: (510) 771-1000   FAX: (510) 661-0888
       This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                  DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                       IC ID: 2417C-GOBI2

6. SYSTEM SPECIFICATIONS




   The DASY4 system for performing compliance tests consists of the following items:
   • A standard high precision 6-axis robot (Stäubli RX family) with controller, teach pendant and
      software. An arm extension for accommodating the data acquisition electronics (DAE).
   • A dosimetric probe, i.e., an isotropic E-field probe optimized and calibrated for usage in tissue
      simulating liquid. The probe is equipped with an optical surface detector system.
   • A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing,
      AD-conversion, offset measurements, mechanical surface detection, collision detection, etc. The
      unit is battery powered with standard or rechargeable batteries. The signal is optically transmitted
      to the EOC.
   • The function of the measurement server is to perform the time critical tasks such as signal
      filtering, control of the robot operation and fast movement interrupts.
   • A probe alignment unit which improves the (absolute) accuracy of the probe positioning.
   • A computer operating Windows 2000 or Windows XP.
   • DASY4 software.
   • Remote controls with teach pendant and additional circuitry for robot safety such as warning
      lamps, etc.
   • The SAM twin phantom enabling testing left-hand and right-hand usage.
   • The device holder for handheld mobile phones.
   • Tissue simulating liquid mixed according to the given recipes.
   • Validation dipole kits allowing validating the proper functioning of the system.




                                          Page 9 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                        FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                   TEL: (510) 771-1000   FAX: (510) 661-0888
       This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                                       DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                                            IC ID: 2417C-GOBI2

7. COMPOSITION OF INGREDIENTS FOR TISSUE SIMULATING LIQUIDS
The following tissue formulations are provided for reference only as some of the parameters have not
been thoroughly verified. The composition of ingredients may be modified accordingly to achieve the
desired target tissue parameters required for routine SAR evaluation.

      Ingredients                                                  Frequency (MHz)
     (% by weight)                450                 835                  915                 1900                   2450
      Tissue Type         Head          Body   Head         Body    Head         Body   Head      Body         Head      Body
         Water            38.56     51.16      41.45        52.4    41.05        56.0   54.9      40.4         62.7      73.2
      Salt (NaCl)          3.95         1.49   1.45         1.4     1.35         0.76   0.18          0.5       0.5      0.04
         Sugar            56.32     46.78      56.0         45.0    56.5      41.76      0.0      58.0          0.0          0.0
          HEC              0.98         0.52    1.0         1.0      1.0         1.21    0.0          1.0       0.0          0.0
      Bactericide          0.19         0.05    0.1         0.1      0.1         0.27    0.0          0.1       0.0          0.0
      Triton X-100         0.0          0.0     0.0         0.0      0.0         0.0     0.0          0.0      36.8          0.0
         DGBE              0.0          0.0     0.0         0.0      0.0         0.0    44.92         0.0       0.0      26.7
  Dielectric Constant     43.42         58.0   42.54        56.1    42.0         56.8   39.9      54.0         39.8      52.5
  Conductivity (S/m)       0.85         0.83   0.91         0.95     1.0         1.07   1.42      1.45         1.88      1.78
Salt: 99+% Pure Sodium Chloride              Sugar: 98+% Pure Sucrose
Water: De-ionized, 16 MΩ+ resistivity        HEC: Hydroxyethyl Cellulose
DGBE: 99+% Di(ethylene glycol) butyl ether, [2-(2-butoxyethoxy)ethanol]
Triton X-100 (ultra pure): Polyethylene glycol mono [4-(1,1, 3, 3-tetramethylbutyl)phenyl]ether

Simulating Liquids for 5 GHz, Manufactured by SPEAG
 Ingredients                (% by weight)
 Water                      78
 Mineral oil                11
 Emulsifiers                9
 Additives and Salt         2




                                          Page 10 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                                     FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                                TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                         DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                              IC ID: 2417C-GOBI2

8. TISSUE DIELECTRIC PARAMETERS CHECK
The simulating liquids should be checked at the beginning of a series of SAR measurements to
determine of the dielectric parameters are within the tolerances of the specified target values. For
frequencies in 300 MHz to 2 GHz, the measured conductivity and relative permittivity should be within ±
5% of the target values. For frequencies in the range of 2–3 GHz and above the measured conductivity
should be within ± 5% of the target values. The measured relative permittivity tolerance can be relaxed to
no more than ± 10%.
Reference Values of Tissue Dielectric Parameters for Body (for 300 – 3000 MHz and 5800 MHz)
The body tissue parameters that have not been specified in P1528 are derived from the tissue dielectric
parameters computed from the 4-Cole-Cole equations and extrapolated according to the head
parameters specified in IEEE Standard 1528.
                                             Body (Supplement C 01-01)
  Target Frequency (MHz)
                                             εr                   σ (S/m)
               300                         58.20                   0.92
               450                         56.70                   0.94
               835                         55.20                   0.97
               900                         55.00                   1.05
               915                         55.00                   1.06
              1450                         54.00                   1.30
              1610                         53.80                   1.40
          1800 – 2000                      53.30                   1.52
              2450                         52.70                   1.95
              3000                         52.00                   2.73
              5800                         48.20                   6.00
(εr = relative permittivity, σ = conductivity and ρ = 1000 kg/m )
                                                               3




                                          Page 11 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                                FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                           TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                              DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                                   IC ID: 2417C-GOBI2

   8.1.         LIQUID CHECK RESULTS
     Date      Freq. (MHz)               Liquid Parameters                  Measured   Target   Delta (%)   Limit ±(%)
                             e'   53.3924     Relative Permittivity (єr):    53.39     55.20      -3.27         5
   5/11/2011   Body 835
                             e"   20.7979             Conductivity (σ):       0.97      0.97      -0.45         5
 Liquid Check
 Ambient temperature: 24deg. C; Liquid temperature: 23 deg. C; Relative Humidity = 39%
 May 11, 2011 05:18 PM
 Frequency              e'                       e''
 800000000.              53.9161                  20.9852
 805000000.              53.9347                  21.0012
 810000000.              53.6533                  20.9836
 815000000.              53.8790                  21.0114
 820000000.              53.6802                  20.7708
 825000000.              53.7071                  20.8631
 830000000.              53.6846                  20.8912
 835000000.              53.3924                  20.7979
 840000000.              53.4867                  20.8234
 845000000.              53.4995                  20.8512
 850000000.              53.4947                  20.8350
 855000000.              53.3095                  20.8973
 860000000.              53.3517                  20.8739
 865000000.              53.2436                  20.7311
 870000000.              53.1990                  20.7289
 875000000.              53.2532                  20.7555
 880000000.              53.1282                  20.7672
 885000000.              53.0550                  20.5411
 890000000.              53.0456                  20.8120
 895000000.              52.9753                  20.7823
 900000000.              52.9642                  20.7800
 905000000.              52.9509                  20.7110
 910000000.              52.9374                  20.4905
 915000000.              53.0581                  20.5829
 920000000.              52.9296                  20.6054
 925000000.              52.8566                  20.6849
 930000000.              52.8061                  20.6177
 935000000.              52.6788                  20.4955
 940000000.              52.5162                  20.5117
 945000000.              52.6450                  20.6126
 950000000.              52.3967                  20.6468
 The conductivity (σ) can be given as:
 σ = ωε0 e''= 2 π f ε0 e''
                        6
 where f = target f * 10
       ε0 = 8.854 * 10-12




                                          Page 12 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                                     FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                                TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                               DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                                    IC ID: 2417C-GOBI2



     Date     Freq. (MHz)                Liquid Parameters                  Measured   Target   Delta (%)   Limit ±(%)
                             e'   53.0518     Relative Permittivity (єr):    53.05     55.20      -3.89         5
  5/12/2011   Body 835
                             e"   20.6589             Conductivity (σ):       0.96      0.97      -1.12         5
 Liquid Check
 Ambient temperature: 24 deg. C; Liquid temperature: 23 deg. C; Relative humidity = 40%
 May 12, 2011 09:19 AM
 Frequency              e'                       e''
 800000000.              53.4077                  20.7803
 805000000.              53.3578                  20.7637
 810000000.              53.3073                  20.7483
 815000000.              53.2504                  20.7261
 820000000.              53.1991                  20.7076
 825000000.              53.1500                  20.6926
 830000000.              53.1017                  20.6755
 835000000.              53.0518                  20.6589
 840000000.              53.0036                  20.6425
 845000000.              52.9569                  20.6245
 850000000.              52.9108                  20.6167
 855000000.              52.8631                  20.6000
 860000000.              52.8158                  20.5793
 865000000.              52.7644                  20.5671
 870000000.              52.7204                  20.5504
 875000000.              52.6713                  20.5340
 880000000.              52.6303                  20.5189
 885000000.              52.5835                  20.4999
 890000000.              52.5370                  20.4865
 895000000.              52.4891                  20.4681
 900000000.              52.4504                  20.4475
 905000000.              52.4095                  20.4280
 910000000.              52.3693                  20.4133
 915000000.              52.3282                  20.3985
 920000000.              52.2928                  20.3778
 925000000.              52.2509                  20.3688
 930000000.              52.2176                  20.3623
 935000000.              52.1766                  20.3551
 940000000.              52.1348                  20.3554
 945000000.              52.0944                  20.3573
 950000000.              52.0431                  20.3523
 The conductivity (σ) can be given as:
 σ = ωε0 e''= 2 π f ε0 e''
                        6
 where f = target f * 10
       ε0 = 8.854 * 10-12




                                          Page 13 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                                      FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                                 TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                               DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                                    IC ID: 2417C-GOBI2



     Date     Freq. (MHz)                Liquid Parameters                  Measured   Target   Delta (%)   Limit ±(%)
                             e'   53.7855     Relative Permittivity (єr):    53.79     55.20      -2.56         5
  5/13/2011   Body 835
                             e"   20.5920             Conductivity (σ):       0.96      0.97      -1.44         5
 Liquid Check
 Ambient temperature: 24 deg. C; Liquid temperature: 23 deg. C; Relative humidity = 40%
 May 13, 2011 03:23 PM
 Frequency              e'                       e''
 800000000.              54.1297                  20.6974
 805000000.              54.0819                  20.6806
 810000000.              54.0240                  20.6652
 815000000.              53.9754                  20.6524
 820000000.              53.9304                  20.6317
 825000000.              53.8797                  20.6207
 830000000.              53.8343                  20.6033
 835000000.              53.7855                  20.5920
 840000000.              53.7415                  20.5740
 845000000.              53.6900                  20.5617
 850000000.              53.6421                  20.5471
 855000000.              53.6003                  20.5299
 860000000.              53.5505                  20.5186
 865000000.              53.5019                  20.5048
 870000000.              53.4557                  20.4861
 875000000.              53.4099                  20.4734
 880000000.              53.3613                  20.4616
 885000000.              53.3124                  20.4433
 890000000.              53.2689                  20.4285
 895000000.              53.2301                  20.4145
 900000000.              53.1819                  20.3941
 905000000.              53.1394                  20.3828
 910000000.              53.0959                  20.3666
 915000000.              53.0595                  20.3569
 920000000.              53.0198                  20.3499
 925000000.              52.9816                  20.3438
 930000000.              52.9378                  20.3358
 935000000.              52.9011                  20.3340
 940000000.              52.8585                  20.3378
 945000000.              52.8160                  20.3368
 950000000.              52.7643                  20.3351
 The conductivity (σ) can be given as:
 σ = ωε0 e''= 2 π f ε0 e''
                        6
 where f = target f * 10
       ε0 = 8.854 * 10-12




                                          Page 14 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                                      FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                                 TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                               DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                                    IC ID: 2417C-GOBI2



     Date     Freq. (MHz)                Liquid Parameters                  Measured   Target   Delta (%)   Limit ±(%)
                             e'   53.6470     Relative Permittivity (єr):    53.65     53.30      0.65          5
  5/16/2011   Body 1900
                             e"   14.7178             Conductivity (σ):       1.55      1.52      2.29          5
 Liquid Check
 Ambient temperature: 24 deg. C; Liquid temperature: 23 deg. C; Relative humidity = 42%
 May 16, 2011 11:25 AM
 Frequency              e'                       e''
 1710000000.             54.3108                  14.0854
 1720000000.             54.2743                  14.1328
 1730000000.             54.2402                  14.1728
 1740000000.             54.2100                  14.2023
 1750000000.             54.1812                  14.2300
 1760000000.             54.1512                  14.2558
 1770000000.             54.1187                  14.2838
 1780000000.             54.0826                  14.3185
 1790000000.             54.0447                  14.3653
 1800000000.             54.0079                  14.4164
 1810000000.             53.9743                  14.4690
 1820000000.             53.9434                  14.5194
 1830000000.             53.9152                  14.5608
 1840000000.             53.8807                  14.5885
 1850000000.             53.8361                  14.6024
 1860000000.             53.7917                  14.6101
 1870000000.             53.7578                  14.6206
 1880000000.             53.7237                  14.6411
 1890000000.             53.6847                  14.6764
 1900000000.             53.6470                  14.7178
 1910000000.             53.6094                  14.7627
 The conductivity (σ) can be given as:
 σ = ωε0 e''= 2 π f ε0 e''
                        6
 where f = target f * 10
       ε0 = 8.854 * 10-12




                                          Page 15 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                                      FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                                 TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                               DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                                    IC ID: 2417C-GOBI2



     Date     Freq. (MHz)                Liquid Parameters                  Measured   Target   Delta (%)   Limit ±(%)
                             e'   53.5405     Relative Permittivity (єr):    53.54     53.30      0.45          5
  5/17/2011   Body 1900
                             e"   14.5679             Conductivity (σ):       1.54      1.52      1.25          5
 Liquid Check
 Ambient temperature: 24 deg. C; Liquid temperature: 23 deg. C; Relative humidity = 42%
 May 16, 2011 11:25 AM
 Frequency              e'                       e''
 1710000000.             54.3108                  14.0854
 1720000000.             54.2743                  14.1328
 1730000000.             54.2402                  14.1728
 1740000000.             54.2100                  14.2023
 1750000000.             54.1812                  14.2300
 1760000000.             54.1512                  14.2558
 1770000000.             54.1187                  14.2838
 1780000000.             54.0826                  14.3185
 1790000000.             54.0447                  14.3653
 1800000000.             54.0079                  14.4164
 1810000000.             53.9743                  14.4690
 1820000000.             53.9434                  14.5194
 1830000000.             53.9152                  14.5608
 1840000000.             53.8807                  14.5885
 1850000000.             53.8361                  14.6024
 1860000000.             53.7917                  14.6101
 1870000000.             53.7578                  14.6206
 1880000000.             53.7237                  14.6411
 1890000000.             53.6847                  14.6764
 1900000000.             53.6470                  14.7178
 1910000000.             53.6094                  14.7627
 The conductivity (σ) can be given as:
 σ = ωε0 e''= 2 π f ε0 e''
                        6
 where f = target f * 10
       ε0 = 8.854 * 10-12




                                          Page 16 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                                      FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                                 TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                      DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                           IC ID: 2417C-GOBI2


SYSTEM VERIFICATION
The system performance check is performed prior to any usage of the system in order to verify SAR
system measurement accuracy. The system performance check verifies that the system operates within
its specifications of ±10%.
System Performance Check Measurement Conditions
• The measurements were performed in the flat section of the SAM twin phantom filled with Head or
   Body simulating liquid of the following parameters.
• The DASY4 system with an Isotropic E-Field Probe EX3DV3 was used for the measurements.
• The dipole was mounted on the small tripod so that the dipole feed point was positioned below the
   center marking of the flat phantom section and the dipole was oriented parallel to the body axis (the
   long side of the phantom). The standard measuring distance was 10 mm (above 1 GHz) and
   15 mm (below 1 GHz) from dipole center to the simulating liquid surface.
• The coarse grid with a grid spacing of 15 mm was aligned with the dipole.
   For 5 GHz band - The coarse grid with a grid spacing of 10 mm was aligned with the dipole.
• Special 7x7x7 fine cube was chosen for cube
• Distance between probe sensors and phantom surface was set to 3 mm.
   For 5 GHz band - Distance between probe sensors and phantom surface was set to 2.5 mm
• The dipole input power (forward power) was 100 mW
• The results are normalized to 1 W input power.

Reference SAR Values for HEAD & BODY-tissue from calibration certificate of SPEAG.
      System                                                  SAR Avg (mW/g)
                      Cal. certificate # Cal. date
 validation dipole                                   Tissue:          Head        Body
      D835V2        D835V2-4d002_Apr11    4/4/11     1g SAR:          9.36         10.2
    SN: 4d002                                       10g SAR:          6.12         6.68
     D1900V2       D1900V2-5d043_Nov09   11/24/09    1g SAR:          39.8         40.4
    SN: 5d043                                       10g SAR:          20.7         21.4


   8.2.       SYSTEM CHECK RESULTS
      System                   Measured (Normalized to 1 W)                                    Tolerance
                   Date Tested                                        Target     Delta (%)
 validation dipole               Tissue:         Body                                             (%)
      D835V2                    1g SAR:          10.0                  10.2        -1.96
                    05/11/11                                                                      ±10
    SN: 4d002                   10g SAR:         6.59                  6.68        -1.35
      D835V2                    1g SAR:          9.91                  10.2        -2.84
                    05/12/11                                                                      ±10
    SN: 4d002                   10g SAR:         6.51                  6.68        -2.54
      D835V2                    1g SAR:          9.75                  10.2        -4.41
                    05/13/11                                                                      ±10
    SN: 4d002                   10g SAR:         6.41                  6.68        -4.04
     D1900V2                    1g SAR:          41.5                  40.4        2.72
                    05/16/11                                                                      ±10
    SN: 5d043                   10g SAR:         21.7                  21.4        1.40
     D1900V2                    1g SAR:          41.3                  40.4        2.23
                    05/17/11                                                                      ±10
    SN: 5d043                   10g SAR:         21.6                  21.4        0.93




                                          Page 17 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                         FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                    TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                   DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                        IC ID: 2417C-GOBI2

9. SAR MEASUREMENT PROCEDURES
Step 1: Power Reference Measurement
The Power Reference Measurement and Power Drift Measurements are for monitoring the power drift of
the device under test in the batch process. The Minimum distance of probe sensors to surface
determines the closest measurement point to phantom surface. The minimum distance of probe sensors
to surface is 2.1 mm. This distance cannot be smaller than the Distance of sensor calibration points to
probe tip as defined in the probe properties (for example, 1.2 mm for an EX3DV3 probe type).

Step 2: Area Scan
The Area Scan is used as a fast scan in two dimensions to find the area of high field values, before doing
a fine measurement around the hot spot. The sophisticated interpolation routines implemented in DASY4
software can find the maximum locations even in relatively coarse grids. When an Area Scan has
measured all reachable points, it computes the field maximal found in the scanned area, within a range
of the global maximum. The range (in dB) is specified in the standards for compliance testing. For
example, a 2 dB range is required in IEEE Standard 1528, EN 50361 and IEC 62209 standards, whereby
3 dB is a requirement when compliance is assessed in accordance with the ARIB standard (Japan). If
only one Zoom Scan follows the Area Scan, then only the absolute maximum will be taken as reference.
For cases where multiple maximums are detected, the number of Zoom Scans has to be increased
accordingly.

Step 3: Zoom Scan
Zoom Scans are used to assess the peak spatial SAR values within a cubic averaging volume containing
1 g and 10 g of simulated tissue. The Zoom Scan measures ≥ 7 x 7 x 9 points within a cube whose base
faces are centered on the maxima found in a preceding area scan job within the same procedure. When
the measurement is done, the Zoom Scan evaluates the averaged SAR for 1 g and 10 g and displays
these values next to the job’s label.

Step 4: Power drift measurement
The Power Drift Measurement measures the field at the same location as the most recent power
reference measurement within the same procedure, and with the same settings. The Power Drift
Measurement gives the field difference in dB from the reading conducted within the last Power
Reference Measurement. This allows a user to monitor the power drift of the device under test within a
batch process. The measurement procedure is the same as Step 1.

Step 5: Z-Scan
The Z Scan measures points along a vertical straight line. The line runs along the Z-axis of a one-
dimensional grid. In order to get a reasonable extrapolation, the extrapolated distance should not be
larger than the step size in Z-direction.




                                          Page 18 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                         FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                    TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                       DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                            IC ID: 2417C-GOBI2

10.   RF OUTPUT POWER VERIFICATION
   10.1.       GSM
GPRS (GMSK) - Coding Scheme: CS1
                                             Avg burst Pwr (dBm)
  Band       Ch No.      f (MHz)               Frame                Frame
                                    1 slot              2 slot
                                              Avg Pwr              Avg Pwr
           128        824.2    32.1             23.1    32.0        26.0
 GSM850    190        836.6    32.2             23.2    32.0        26.0
           251        848.8    32.0             23.0    31.9        25.9
           512       1850.2    30.0             21.0    29.9        23.9
GSM1900    661        1880     30.0             21.0    29.8        23.8
           810       1909.8    29.8             20.8    29.8        23.8
EGPRS (8PSK) - Coding Scheme: MCS5
                                             Avg burst Pwr (dBm)
  Band       Ch No.      f (MHz)               Frame                Frame
                                    1 slot              2 slot
                                              Avg Pwr              Avg Pwr
               128        824.2     27.9        18.9    27.7        21.7
 GSM850        190        836.6     27.9        18.9    27.8        21.8
               251        848.8     27.9        18.9    27.8        21.8
               512       1850.2     26.7        17.7    26.7        20.7
GSM1900        661        1880      26.7        17.7    26.7        20.7
               810       1909.8     26.3        17.3    26.3        20.3

Note:
   1. Since the source-based time-averaged output power for EGPRS mode is lower than that in the
      GPRS mode, therefore Body SAR test reduction is applicable for this device.
   2. Based on output power above and time slots, the following worst-case configurations were
      chosen for Body SAR testing.
         a. GPRS850 2 time slots
         b. GPRS1900 2 time slots




                                          Page 19 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                              FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                         TEL: (510) 771-1000   FAX: (510) 661-0888
         This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                   DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                        IC ID: 2417C-GOBI2


10.2. UMTS RELEASE 99
The following tests were completed according to the test requirements outlined in section 5.2 of the
3GPP TS34.121-1 specification. The EUT supports power Class 3, which has a nominal maximum
output power of 24 dBm (+1.7/-3.7).
                      Mode                                  Rel99
                      Subtest                               -
                      Loopback Mode                         Test Mode 1
 WCDMA      General   Rel99 RMC                             12.2kbps RMC
 Settings             Power Control Algorithm               Algorithm2
                      βc/βd                                 8/15

Results
Rel 99 (12.2kps RMC)
    Band        Mode          UL Ch No.         DL Ch No.     f (MHz)      Avg Tx Pwr (dBm)
                Rel 99          4132              4357         826.4             24.6
 UMTS850
              12.2kbps          4183              4408         836.6             25.0
  (Band V)
                RMC             4233              4458         846.6             24.9
                  Rel 99        9262              9662        1852.4             24.7
 UMTS1900
                 12.2kps        9400              9800        1880.0             25.1
  (Band II)
                  RMC           9538              9938        1907.6             24.7




                                          Page 20 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                         FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                    TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                  DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                       IC ID: 2417C-GOBI2


   10.3.      CDMA2000
CDMA2000 1xRTT
This procedure assumes the Agilent 8960 Test Set has the following applications installed and with valid
license.
Application                Rev, License
CDMA2000 Mobile Test       B.13.08, L
   • Protocol Rev > 6 (IS-2000-0)
   • System ID: 2004 (Cell & PCS); NID: 65535 (Cell & PCS); Reg. Ch. #.: 384 (Cell) & 600 (PCS)
   • Radio Config (RC) > Please see following table for details
   • FCH Service Option (SO) Setup > Please see following table or details
   • Traffic Data Rate > Full
   • TDSO SCH Info > F-SCH Parameters > F-SCH Data Rate > 153.6 kbps
                      > R-SCH Parameters > R-SCH Data Rate > 153.6 kbps
   • Rvs Power Ctrl > All Up bits (Maximum TxPout)

RF Output Power for Cellular Band
    Radio                                         Conducted Output Power (dBm)
               Service Option
 Configuration                   Ch. 1013/824.7 MHz   Ch. 384/836.52 MHz    Ch. 777/848.31 MHz
                    (SO)
    (RC)                               Average              Average               Average
     RC1       55 (Loopback)            24.5                 24.5                  24.5
               55 (Loopback)            24.6                 24.5                  24.6
     RC3
               32 (+ F-SCH)             24.5                 24.5                  24.6


RF Output Power for PCS Band

    Radio                                           Conducted Output Power (dBm)
 Configuration Service Option       Ch. 25/1851.25 MHz   Ch. 600/1880 MHz Ch. 1175/1908.75 MHz
    (RC)             (SO)                Average              Average            Average
     RC1       55 (Loopback)               24.7                25.0               24.7
               55 (Loopback)               24.7                25.1               24.8
     RC3
               32 (+ F-SCH)                24.9                25.1               25.0




                                          Page 21 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                        FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                   TEL: (510) 771-1000   FAX: (510) 661-0888
       This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                     DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                          IC ID: 2417C-GOBI2

11.    SUMMARY OF TEST RESULT
                            Antenna-to-User     SAR
Configuration                                              Comments
                            distance            Require
Laptop mode: Lap-held       158 mm              Yes
                            From Main-to-user
Bottom Face                 32 mm               Yes
                            From Antenna-to-
                            user
Edge - Primary              138 mm              No         This is not the most conservative antenna-to-
Landscape                   From Main-to-user              user distance at edge mode. Per According to
                                                           KDB 447498 4) b) ii) (2)
Edge - Secondary            21 mm               Yes        This is the most conservative antenna-to-user
Landscape                   From antenna-to-               distance at edge mode. According to KDB
                            user                           447498 4) b) ii) (2), SAR is required only for the
                                                           edge with the most conservative exposure
                                                           conditions.
Edge - Primary Portrait     295 mm from         No         SAR is not required due to separation distance
                            antenna to                     > 20 cm from antenna-to-user.
                            Primary edge
Edge - Secondary Portrait   < 2 mm from         No         Main antenna is disabled by software at this
                            antenna to edge                configuration.




                                          Page 22 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                         FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                    TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                  DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                       IC ID: 2417C-GOBI2

   11.1.     GPRS 850 & 1900
Laptop Mode - LapHeld
                                                                  SAR (mW/g)
    Band           Slot         Ch No.      Freq. (MHz)
                                                               1-g         10-g
                                 128          824.2
  GPRS850           2            190          836.6           0.077         0.060
                                 251          848.8
                                 512          1850.2
 GPRS1900           2            661          1880.0        0.00664        0.00244
                                 810          1909.8
Tablet Mode - Bottom Face
                                                                  SAR (mW/g)
    Band           Slot         Ch No.      Freq. (MHz)
                                                               1-g         10-g
                             128              824.2
  GPRS850         2          190              836.6           0.074         0.051
                             251              848.8
                             512              1850.2
 GPRS1900         2          661              1880.0          0.023         0.014
                             810              1909.8
Tablet Mode – Secondary Landscape
                                                                  SAR (mW/g)
    Band           Slot         Ch No.      Freq. (MHz)
                                                               1-g         10-g
                                 128          824.2
  GPRS850           2            190          836.6           0.204         0.126
                                 251          848.8
                                 512          1850.2
 GPRS1900           2            661          1880.0          0.471         0.225
                                 810          1909.8




                                          Page 23 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                        FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                   TEL: (510) 771-1000   FAX: (510) 661-0888
       This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                  DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                       IC ID: 2417C-GOBI2


   11.2.     UMTS BAND V & II
Test reduction considerations:
KDB 941225 D01 – Body SAR is not required for HSDPA when the maximum average output of each RF
channel with HSDPA active is less than ¼ dB higher than that measured without HSDPA using 12.2 kbps
RMC or the maximum SAR for 12.2 kbps RMC is < 75% of the SAR limit.
Laptop Mode - LapHeld
                                                                  SAR (mW/g)
   Band        Mode     UL Ch No. DL Ch No.       f (MHz)
                                                                1-g        10-g
                R99        4132        4357        826.4
  Band V      12.2kbps     4183        4408        836.6       0.019      0.014
                RMC        4233        4458        846.6
                R99        9262        9662      1850.2
  Band II    12.2kbps      9400        9800      1880.0        0.011     0.00735
                RMC        9538        9938      1907.6
Tablet Mode – Bottom Face
                                                                  SAR (mW/g)
   Band        Mode     UL Ch No. DL Ch No.       f (MHz)
                                                                1-g        10-g
                R99        4132        4357        826.4
  Band V      12.2kbps     4183        4408        836.6       0.221      0.147
                RMC        4233        4458        846.6
                R99        9262        9662      1850.2
  Band II    12.2kbps      9400        9800      1880.0        0.022      0.014
                RMC        9538        9938      1907.6
Tablet Mode – Secondary Landscape
                                                                  SAR (mW/g)
   Band        Mode     UL Ch No. DL Ch No.       f (MHz)
                                                                1-g        10-g
                R99        4132        4357        826.4
  Band V      12.2kbps     4183        4408        836.6       0.261      0.159
                RMC        4233        4458        846.6
                R99        9262        9662      1850.2
  Band II    12.2kbps      9400        9800      1880.0        0.625      0.300
                RMC        9538        9938      1907.6




                                          Page 24 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                        FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                   TEL: (510) 771-1000   FAX: (510) 661-0888
       This report shall not be reproduced except in full, without the written approval of UL CCS.


REPORT NO: 11J13758-1                                                                  DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                       IC ID: 2417C-GOBI2


   11.3.      CDMA2000 Cell & PCS Band
Laptop Mode - LapHeld
    Band           Mode           Ch No.        f (MHz)            SAR (mW/g)
                                                                 1-g       10-g
                                   1013          824.70
                 1xRTT
   Cellular                         384          836.52         0.044          0.03
               (RC3, SO32)
                                    777          848.31
                                     25         1851.25
                 1xRTT
    PCS                             600         1880.00         0.011         0.0063
               (RC3, SO32)
                                   1175         1908.75
Tablet Mode – Bottom Face
    Band           Mode           Ch No.        f (MHz)            SAR (mW/g)
                                                                 1-g       10-g
                              1013               824.70
                 1xRTT
   Cellular                   384                836.52         0.185         0.126
               (RC3, SO32)
                              777                848.31
                               25               1851.25
                 1xRTT
    PCS                       600               1880.00         0.03          0.014
              (RC3, SO32)
                              1175              1908.75
Tablet Mode – Secondary Landscape
    Band           Mode           Ch No.        f (MHz)            SAR (mW/g)
                                                                 1-g       10-g
                                   1013          824.70
                 1xRTT
   Cellular                         384          836.52         0.262         0.159
               (RC3, SO32)
                                    777          848.31
                                     25         1851.25
                 1xRTT
    PCS                             600         1880.00         0.485         0.239
               (RC3, SO32)
                                   1175         1908.75




                                          Page 25 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                        FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                   TEL: (510) 771-1000   FAX: (510) 661-0888
       This report shall not be reproduced except in full, without the written approval of UL CCS.


                                                                                        Date/Time: 5/13/2011 9:00:23 PM

Test Laboratory: UL CCS


5_Secondary Landscape

DUT: Panasonic ; Type: Tablet; Serial: 1BKKS$A00017


Communication System: UMTS Band V; Frequency: 836.6 MHz; Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.6 MHz; s = 0.958 mho/m; & = 53.771; ? = 1000 kg/m3
Phantom section: Flat Section

Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C

DASY5 Configuration:
— Area Scan setting — Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
— Probe: EX3DV4 — SN3686; ConvF(8.78, 8.78, 8.78); Calibrated: 1/24/2011
— Sensor—Surface: 2.5mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn1239; Calibrated: 11/17/2010
— Phantom: ELI 4.0; Type: QDOVAOO1BB; Serial: 1099
— Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595)


UMTS/Band V_R99_CH4183/Area Scan (9x16x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.309 mW/q

UMTS/Band V_R99_CH4183/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=3mm
Reference Value = 18.210 V/im; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 0.462 Wikq
SAR(1 g) = 0.261 mW/g; SAR(10 g) = 0.159 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.336 mW/q


  mWiq
   0.336


   0.274



   0.212


   0.150



   0.089



   0.027


                                                                                    Date/Time: 5/13/2011 9:18:13 PM

Test Laboratory: UL CCS


5_Secondary Landscape

DUT: Panasonic ; Type: Tablet; Serial: 1BKKSA00017


Communication System: UMTS Band V; Frequency: 836.6 MHz;Duty Cycle: 1:1


UMTS/Band V_R99_CH41 83/Z Scan (1X1X21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.335 mW/g


                                                        SAR(x.y.z.f0)
                                       mz                                  T



                  ad
                  O3      SARZ Scan:Value Along Z, X=0, Y=0               Markers




                  l
                  s»l—\
          mivta




                  0.15     \


                  0.10




                  0.00


                                                                                      Date/Time: 5/17/2011 12:31:30 AM

Test Laboratory: UL CCS


5_Secondary Landscape
DUT: Panasonic ; Type: Tablet; Serial: 1BKKSA00017


Communication System: UMTS Band II; Frequency: 1880 MHz; Duty Cycle: 1:1
Medium parameters used: f= 1880 MHz; s = 1.531 mho/m; & = 53.724; ? = 1000 kg/m3
Phantom section: Flat Section

Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C

DASY5 Configuration:
— Area Scan setting — Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kq
— Probe: EX3DV4 — SN3686; ConvF(6.99, 6.99, 6.99); Calibrated: 1/24/2011
— Sensor—Surface: 2.5mm (Mechanical Surface Detection)
— Electronics: DAE4 $n1239; Calibrated: 11/17/2010
— Phantom: ELI 4.0; Type: QDOVAOO1BB; Serial: 1099
— Measurement SW: DASY52, Version 52.6 (1);SEMCAD X Version 14.4.2 (2595)


UMTS/Band II_R99_CH_9400/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.659 mW/q

UMTS/Band II_R99_CH_9400/Zoom Scan (7x7x9)/Cube 0: Measurement grid: ¢x=5mm, dy=5mm,
dz=3mm
Reference Value = 20.941 V/im; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 1.180 W/kg
SAR(1 g) = 0.625 mW/g; SAR(10 g) = 0.300 mW/g
Maximum value of SAR (measured) = 0.861 mW/q


  dB
   0                                                   a
   ~3.58


   FAZ


   —10.75


   —14.34
                  z9
                 K.,
   ~17.92
              0 dB = 0.860mW/«


                                                                                 Date/Time: 5172011 124921 AM

Test Laboratary UL CCS


5_Secondary Landscape

DUT: Panasonic; Type: Tablet; Seri: 1BKKSAOOOT7

Communication System: UMTS Band it Frequency: 1880 MHzDuty Cyele: 1:1

UMTS/Band II_R99_CH_9400/Z Scan (1X1X21); Measurement grid: t=20mm, dy=20mm, de=5mm
Maxmum value of SAR (measured) = 0.850 miig
                                                   SAR(c3:z.00)
                                     w                                   _
             5s          SASeanvalseAlng 2. 300.¥—0                     markrs

             PA

             hl_|
             sa
             es


             e
             so
               odo       oo    olr     obn    ob      o     ols    oi   om        otr    or


REPORT NO: 11J13758-1                                                                      DATE: May 19, 2011
FCC ID: N7NGOBI2                                                                           IC ID: 2417C-GOBI2

12.     ATTACHMENTS
 No.    Contents                                                                           No. of page (s)
  1     System Check Plots                                                                        10
  2-1   SAR Test Plots for GSM850                                                                 3
  2-2   SAR Test Plots for GSM1900                                                                3
  2-3   SAR Test Plots for UMTS band V                                                            3
  2-4   SAR Test Plots for UMTS band II                                                           3
  2-5   SAR Test Plots for CDMA2000 Cellular band                                                 3
  2-6   SAR Test Plots for CDMA2000 PCS band                                                      3
  3     Certificate of E-Field Probe - EX3DV3 SN 3686                                             11
  4     Certificate of System Validation Dipole - D835V2 SN:4d002                                 10
  5     Certificate of System Validation Dipole - D1900V2 SN:5d043                                11




                                          Page 30 of 34
COMPLIANCE CERTIFICATION SERVICES (UL CCS)                                             FORM NO: CCSUP4031B
47173 BENICIA STREET, FREMONT, CA 94538, USA                        TEL: (510) 771-1000   FAX: (510) 661-0888
        This report shall not be reproduced except in full, without the written approval of UL CCS.



Document Created: 2011-05-19 14:04:37
Document Modified: 2011-05-19 14:04:37

© 2024 FCC.report