SAR attachment 1-3

FCC ID: N7NGOBI2

RF Exposure Info

Download: PDF
FCCID_1367852

                                                                                       Date/Time: 9/17/2010 3:17:22 PM

Test Laboratory: Compliance Certification Services

UMTS band V_Laptop Mode
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: UMTS Band V; Frequency: 836.4 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.4 MHz; σ = 0.989 mho/m; εr = 56.4; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

M-ch_ Ant retracted/Area Scan (14x14x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.008 mW/g

M-ch_ Ant retracted/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 2.61 V/m; Power Drift = 0.193 dB
Peak SAR (extrapolated) = 0.012 W/kg
SAR(1 g) = 0.0075 mW/g; SAR(10 g) = 0.00719 mW/g
Info: Interpolated medium parameters used for SAR evaluation.


                                                                                       Date/Time: 9/17/2010 3:52:15 PM

Test Laboratory: Compliance Certification Services

UMTS band V_Laptop Mode
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: UMTS Band V; Frequency: 836.4 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.4 MHz; σ = 0.989 mho/m; εr = 56.4; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

M-ch_Ant extended/Area Scan (14x14x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.018 mW/g

M-ch_Ant extended/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 4.22 V/m; Power Drift = -0.072 dB
Peak SAR (extrapolated) = 0.023 W/kg
SAR(1 g) = 0.017 mW/g; SAR(10 g) = 0.014 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.019 mW/g


                                                                                      Date/Time: 9/17/2010 11:23:27 AM

Test Laboratory: Compliance Certification Services

UMTS band V_Bottom face
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: UMTS Band V; Frequency: 836.4 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.4 MHz; σ = 0.986 mho/m; εr = 53.1; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

M-ch_Ant retracted/Area Scan (11x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.009 mW/g

M-ch_Ant retracted/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 2.89 V/m; Power Drift = 0.245 dB
Peak SAR (extrapolated) = 0.013 W/kg
SAR(1 g) = 0.00816 mW/g; SAR(10 g) = 0.0078 mW/g
Info: Interpolated medium parameters used for SAR evaluation.

M-ch_Ant retracted/Zoom Scan (7x7x9)/Cube 1: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 2.89 V/m; Power Drift = 0.245 dB
Peak SAR (extrapolated) = 0.010 W/kg
SAR(1 g) = 0.00866 mW/g; SAR(10 g) = 0.00827 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.010 mW/g




                      0 dB = 0.010mW/g


                                                                                      Date/Time: 9/17/2010 12:06:15 PM

Test Laboratory: Compliance Certification Services

UMTS band V_Bottom face
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: UMTS Band V; Frequency: 836.4 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.4 MHz; σ = 0.986 mho/m; εr = 53.1; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

M-ch_Ant extended/Area Scan (9x9x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.321 mW/g

M-ch_Ant extended/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 17.8 V/m; Power Drift = 0.071 dB
Peak SAR (extrapolated) = 0.411 W/kg
SAR(1 g) = 0.297 mW/g; SAR(10 g) = 0.206 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.339 mW/g


                                                                          Date/Time: 9/17/2010 12:30:13 PM

Test Laboratory: Compliance Certification Services

UMTS band V_Bottom face
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: UMTS Band V; Frequency: 836.4 MHz;Duty Cycle: 1:1



M-ch_Ant extended/Z Scan (1x1x29): Measurement grid: dx=20mm, dy=20mm, dz=3.5mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.310 mW/g


                                                                                       Date/Time: 9/16/2010 5:53:56 PM

Test Laboratory: Compliance Certification Services

UMTS Bnad V_Secondary Landscape
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: UMTS Band V; Frequency: 836.4 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.4 MHz; σ = 0.986 mho/m; εr = 53.1; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

M-ch_Ant retracted/Area Scan (8x9x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.251 mW/g

M-ch_Ant retracted/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 16.6 V/m; Power Drift = -0.155 dB
Peak SAR (extrapolated) = 0.862 W/kg
SAR(1 g) = 0.252 mW/g; SAR(10 g) = 0.112 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.362 mW/g


                                                                                       Date/Time: 9/16/2010 6:38:10 PM

Test Laboratory: Compliance Certification Services

UMTS band V_Primary Portrait
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: UMTS Band V; Frequency: 836.4 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.4 MHz; σ = 0.986 mho/m; εr = 53.1; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

M-ch_Ant retracted/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.020 mW/g

M-ch_Ant retracted/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 4.49 V/m; Power Drift = 0.13 dB
Peak SAR (extrapolated) = 0.045 W/kg
SAR(1 g) = 0.023 mW/g; SAR(10 g) = 0.013 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.029 mW/g


                                                                                       Date/Time: 9/16/2010 7:08:37 PM

Test Laboratory: Compliance Certification Services

UMTS band V_Primary Portrait
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: UMTS Band V; Frequency: 836.4 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.4 MHz; σ = 0.986 mho/m; εr = 53.1; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

M-ch_Ant extended/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.382 mW/g

M-ch_Ant extended/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 17.2 V/m; Power Drift = -0.183 dB
Peak SAR (extrapolated) = 0.523 W/kg
SAR(1 g) = 0.276 mW/g; SAR(10 g) = 0.178 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.359 mW/g



Document Created: 2010-09-17 16:35:09
Document Modified: 2010-09-17 16:35:09