SAR attachment 1-1

FCC ID: N7NGOBI2

RF Exposure Info

Download: PDF
FCCID_1367850

                                                                                        Date/Time: 9/17/2010 5:43:54 PM

Test Laboratory: Compliance Certification Services

Cellular 850_Laptop Mode
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.99 mho/m; εr = 56.4; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

2 slot_M-ch_Ant retracted/Area Scan (14x14x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.008 mW/g

2 slot_M-ch_Ant retracted/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=3mm
Reference Value = 2.46 V/m; Power Drift = 0.16 dB
Peak SAR (extrapolated) = 0.010 W/kg
SAR(1 g) = 0.00748 mW/g; SAR(10 g) = 0.00717 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.009 mW/g


                                                                                        Date/Time: 9/17/2010 5:07:56 PM

Test Laboratory: Compliance Certification Services

Cellular 850_Laptop Mode
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.99 mho/m; εr = 56.4; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

2 slot_M-ch_ Ant extended/Area Scan (14x14x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.020 mW/g

2 slot_M-ch_ Ant extended/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=3mm
Reference Value = 4.56 V/m; Power Drift = -0.198 dB
Peak SAR (extrapolated) = 0.023 W/kg
SAR(1 g) = 0.018 mW/g; SAR(10 g) = 0.015 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.021 mW/g


                                                                                      Date/Time: 9/17/2010 10:35:13 AM

Test Laboratory: Compliance Certification Services

Cellular 850_Bottom face
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.986 mho/m; εr = 53.1; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

2 slot_M-ch_Ant retracted/Area Scan (11x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.010 mW/g

2 slot_M-ch_Ant retracted/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=3mm
Reference Value = 3.01 V/m; Power Drift = 0.140 dB
Peak SAR (extrapolated) = 0.017 W/kg
SAR(1 g) = 0.00899 mW/g; SAR(10 g) = 0.00846 mW/g
Info: Interpolated medium parameters used for SAR evaluation.

2 slot_M-ch_Ant retracted/Zoom Scan (7x7x9)/Cube 1: Measurement grid: dx=5mm, dy=5mm,
dz=3mm
Reference Value = 3.01 V/m; Power Drift = 0.140 dB
Peak SAR (extrapolated) = 0.011 W/kg
SAR(1 g) = 0.0088 mW/g; SAR(10 g) = 0.00814 mW/g
Info: Interpolated medium parameters used for SAR evaluation.


                                                                                       Date/Time: 9/17/2010 9:56:34 AM

Test Laboratory: Compliance Certification Services

Cellular 850_Bottom face
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.986 mho/m; εr = 53.1; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

2 slot_M-ch_Ant extracted/Area Scan (9x9x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.415 mW/g

2 slot_M-ch_Ant extracted/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=3mm
Reference Value = 20.6 V/m; Power Drift = 0.072 dB
Peak SAR (extrapolated) = 0.559 W/kg
SAR(1 g) = 0.390 mW/g; SAR(10 g) = 0.267 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.449 mW/g


                                                                     Date/Time: 9/17/2010 10:19:23 AM

Test Laboratory: Compliance Certification Services

Cellular 850_Bottom face
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4



2 slot_M-ch_Ant extracted/Z Scan (1x1x29): Measurement grid: dx=20mm, dy=20mm, dz=3.5mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.453 mW/g


                                                                                       Date/Time: 9/16/2010 4:43:59 PM

Test Laboratory: Compliance Certification Services

Cellular 850_Secondary Landscape
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.986 mho/m; εr = 53.1; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

2 slot_M-ch_Ant retracted/Area Scan (8x9x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.270 mW/g

2 slot_M-ch_Ant retracted/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=3mm
Reference Value = 16.7 V/m; Power Drift = -0.14 dB
Peak SAR (extrapolated) = 1.06 W/kg
SAR(1 g) = 0.290 mW/g; SAR(10 g) = 0.122 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.391 mW/g


                                                                                       Date/Time: 9/16/2010 8:48:36 PM

Test Laboratory: Compliance Certification Services

Cellular 850_Primary Portrait
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.986 mho/m; εr = 53.1; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

2 slot_M-ch_Ant retracted/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.019 mW/g

2 slot_M-ch_Ant retracted/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=3mm
Reference Value = 4.47 V/m; Power Drift = 0.111 dB
Peak SAR (extrapolated) = 0.037 W/kg
SAR(1 g) = 0.021 mW/g; SAR(10 g) = 0.012 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.026 mW/g


                                                                                       Date/Time: 9/16/2010 8:24:08 PM

Test Laboratory: Compliance Certification Services

Cellular 850_Primary Portrait
DUT: Fujitsu-Australia; Type: NA; Serial: NA

Communication System: GSM850; Frequency: 836.6 MHz;Duty Cycle: 1:4
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.986 mho/m; εr = 53.1; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

2 slot_M-ch_Ant extended/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.378 mW/g

2 slot_M-ch_Ant extended/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=3mm
Reference Value = 19.9 V/m; Power Drift = 0.129 dB
Peak SAR (extrapolated) = 0.550 W/kg
SAR(1 g) = 0.360 mW/g; SAR(10 g) = 0.237 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.417 mW/g



Document Created: 2010-09-29 17:36:58