AR7550 Module FCC MPE Evaluation v4

FCC ID: N7NAR7550

RF Exposure Info

Download: PDF
FCCID_1961577

MPE Evaluation for
AR7550 Wireless
    Module

       May 6, 2013


1. Introduction

     In this application we seek for modular approval to the AR7550 wireless
     module for use in standalone and collocated simultaneous transmission under
     mobile configuration. This Maximum Permissive Exposure (MPE) report
     demonstrates compliance analysis for AR7550 wireless module with FCC CFR
     47 §2.1091 and IC RSS-102 for standalone and collocated transmission in
     mobile exposure conditions. The MPE analysis is limited for US / Canada
     bands only.

     The general population/uncontrolled exposure limits are applicable to situations
     in which the general public may be exposed or in which persons who are
     exposed as a consequence of their employment may not be made fully aware
     of the potential for exposure or cannot exercise control over their exposure.

     Any collocated transmitter must have a valid FCC ID documenting equivalent or
     degraded RF characteristics with the collocated parameters defined in this MPE
     report. A separation distance of 20cm or more shall be maintained between the
     end user and each WWAN, WiMAX or WLAN, and Bluetooth transmitting
     antenna.

     Portable user conditions or additional collocated transmitters not allowed
     based on this RF exposure analysis require a Class II permissive change and
     updated RF exposure report.


2. RF Exposure Limits and Equations

      FCC RULES:

      According to FCC OET Bulletin 65 Supplement C, the criteria listed in Table 1
      shall be used to evaluate the environmental impact of human exposure to radio




      frequency (RF) radiation as specified in §1.1307.

             Table 1 : Limits for Maximum Permissible Exposure (MPE)

IC RULES:

IC has adopted the RF field strength limits established in Health Canada’s RF
exposure guideline. The limits are shown in Table 2 below per RSS
102.




     Table 2 : RF Field Strength Limits for Devices Used by the General Public
                            (Uncontrolled Environment)


EQUATIONS:

Power density is given by :

       S = EIRP /(4 * Pi* D^2)

where S = Power density (mW/cm^2) EIRP = Equivalent Isotropic Radiated Power
      (mW)
      D = Separation distance (cm)


3. Product Declarations

  The AR7550 wireless module can be installed for use in any mobile host as long as
  the antenna gain of the host antenna does not exceed the gain listed in table 3.

  This MPE analysis is applicable to any collocated transmitters with transmit
  power:
   -less than or equal to 29.0dBm for WLAN/WiMAX; and
   -less than or equal to 15.0dBm for BT.

   Specific FCC IDs for those devices are not necessary or identified in this
   analysis providing they are classified as mobile transmitters. A 100% duty cycle
   is used for calculations to present a worse-case analysis when applicable.


                          Max        Transmitter       Maximum        Maximum Antenna Gain
           Equipment                                Conducted Power            (dBi)
 Mode                  Transmitter      Range
            Category
                        Duty Cycle      (MHz)      (dBm)      (W)     Standalone Collocated
                                      824‐849      25.0      0.32        6.5         3.0
 CDMA       EvDo         100%
                                     1850‐1910     25.0      0.32        3.0         3.0

            HSDPA                     824 ‐849     24.5      0.25        6.5         3.0
 UMTS                    100%
            HSUPA                    1850 ‐1910    24.5      0.25        3.0         3.0
           Band 13                    777 ‐787     24.0      0.25        9.0         6.0
  LTE       Band 7       100%        2500‐2570     24.0      0.25        9.0         9.0
            Band 4                   1710 ‐1755    24.0      0.25        6.0         6.0



        Table 3: AR7550 Standalone and Collocated Transmission Declarations


4. MPE Calculations

     The WWAN MPE calculations are based on conservative conducted transmit
     power exceeding those listed in the FCC ID N7NAR7550 and IC number
     2417C-AR7550 filing. The higher transmit power levels are used to present a
     worst case assessment.

     The WiMAX, WLAN, and BT transmit power and antenna gain parameters
     represent a maximum transmit power for a given frequency band.

     Integration of either a WiMAX or WLAN, and BT module that exceeds the
     parameters requires a new FCC authorization or permissive change
     application. A maximum antenna gain of 5 dBi for WLAN/WiMAX/BT has been
     assumed for all collocated antennas.

     Table 4, 5, and 6 summarize transmitter parameters associated with this
     analysis.


                            4.1.Individual Transmitter Calculations

                                4.1.1. Maximum Output Power

                                         The maximum power calculations for AR7550 per wireless technology are
                                         shown in Table 4

                                                        Maximum                 Maximum                                              Max
                                                                    Maximum                        Max     Max      Max     Max
                                           Frequency    Conducted               Antenna   Duty                                      output
                            Technology                              Conducted                      EIRP    EIRP     ERP     ERP
                                             (MHz)       Power                   Gain     Cycle                                     power
                                                                    Power (W)                     (dBm)     (W)    (dBm)    (W)
                                                         (dBm)                   (dBi)                                               limit
                            CDMA BC0        824‐849       25.0        0.32        6.5     1.000   31.500   1.413   29.360   0.863   7 W ERP
AR7550 module(Standalone)




                            CDMA BC1       1850‐1910      25.0        0.32        3.0     1.000   28.000   0.631   25.860   0.385   2 W EIRP

                              UMTS          824 ‐849      24.5        0.25        6.5     1.000   31.000   1.258   28.860   0.769   7 W ERP

                              UMTS         1850 ‐1910     24.5        0.25        3.0     1.000   27.500   0.562   25.360   0.344   2 W EIRP

                               LTE          777 ‐787      24.0        0.25        9.0     1.000   33.000   1.995   30.860   1.219   3 W ERP

                               LTE         2500‐2570      24.0        0.25        9.0     1.000   33.000   1.995   30.860   1.219   2 W EIRP

                               LTE         1710 ‐1755     24.0        0.25        6.0     1.000   30.000   1.000   27.860   0.611   1 W EIRP



                                                 Table 4: AR7550 Maximum Output Power Calculation


                            4.1.2. Standalone Power Density

                             The power density calculations for the individual transmitters per wireless technology
                             at an exposure minimum separation distance of 20cm are shown in Table 5.

                             For frequency dependent limit, the lowest transmitter frequency was used to represent
                                                                                              2
                             the lowest MPE limit in this analysis (eg. 824MHz = 0.549mW/cm )

                                                      Maximum                 Maximum                                  Power
                                                                  Maximum                       Average   Average                  FCC MPE
                                         Frequency    Conducted               Antenna   Duty                          Density @
                            Technology                            Conducted                       EIRP     EIRP                      Limit
                                           (MHz)       Power                   Gain     Cycle                           20cm
                                                                  Power (W)                      (dBm)     (mW)                   (mW/cm^2)
                                                       (dBm)                   (dBi)                                 (mW/cm^2)
                            CDMA BC0      824‐849        25.0       0.32        6.5     1.000    31.50    1412.538     0.281        0.549
AR7550 module(Standalone)




                            CDMA BC1     1850‐1910       25.0       0.32        3.0     1.000    28.00    630.957      0.126        1.000

                              UMTS        824 ‐849       24.5       0.25        6.5     1.000    31.00    1258.93      0.250        0.549

                              UMTS       1850 ‐1910      24.5       0.25        3.0     1.000    27.50    562.341      0.112        1.000

                               LTE        777 ‐787       24.0       0.25        9.0     1.000    33.00    1995.262     0.397        0.518

                               LTE       2500‐2570       24.0       0.25        9.0     1.000    33.00    1995.262     0.397        1.000

                               LTE       1710 ‐1755      24.0       0.25        6.0     1.000    30.00    1000.000     0.199        1.000


                                                      Table 5: AR7550 Standalone MPE Calculation


                                 4.2. Collocated MPE Calculation

                                      The WiMAX, WLAN, and BT power levels listed represent the worse-case scenario
                                      for corresponding frequency ranges given.

                                                           Maximum                 Maximum                                  Power
                                                                       Maximum                       Average   Average                  FCC MPE
                                              Frequency    Conducted               Antenna   Duty                          Density @
                                 Technology                            Conducted                       EIRP     EIRP                      Limit
                                                (MHz)       Power                   Gain     Cycle                           20cm
                                                                       Power (W)                      (dBm)     (mW)                   (mW/cm^2)
                                                            (dBm)                   (dBi)                                 (mW/cm^2)
                                 CDMA BC0      824‐849       25.0        0.32        3.0     1.000    28.00    630.957      0.126        0.549
    AR7550 module (Collocated)




                                 CDMA BC1     1850‐1910      25.0        0.32        3.0     1.000    28.00    630.957      0.126        1.000

                                   UMTS        824 ‐849      24.5        0.28        3.0     1.000    31.00    562.341      0.112        0.549

                                   UMTS       1850 ‐1910     24.5        0.28        3.0     1.000    27.50    562.341      0.112        1.000

                                    LTE        777 ‐787      24.0        0.25        6.0     1.000    30.00    1000.000     0.199        0.518

                                    LTE       2500‐2570      24.0        0.25        9.0     1.000    33.00    1995.262     0.397        1.000

                                    LTE       1710 ‐1755     24.0        0.25        6.0     1.000    30.00    1000.000     0.199        1.000

                                   WLAN       2400 ‐2500     29.0        0.794       5.0     1.000    34.00    2511.886     0.500        1.000
Other Collocated




                                   WLAN       5150 ‐5850     29.0        0.794       5.0     1.000    34.00    2511.886     0.500        1.000
 Transmitters




                                  WiMax       2300 ‐2400     29.0        0.794       5.0     1.000    34.00    2511.886     0.500        1.000

                                  WiMax       2500 ‐2700     29.0        0.794       5.0     1.000    34.00    2511.886     0.500        1.000

                                  WiMax       3300 ‐3800     29.0        0.794       5.0     1.000    34.00    2511.886     0.500        1.000

                                    BT        2400 ‐2500     15.0        0.032       5.0     1.000    20.00    100.000      0.020        1.000



                                                           Table 6: AR7550 Collocated MPE Calculation


            Per OET Bulletin 65, when RF sources have difference frequencies, the fraction of the
            FCC power density limit shall be determined and the sum of all fractional components
            shall be less than 1.

              WLAN/WiMAX          WLAN/WiMAX Pd                                WLAN/WiMAX +
                                                    BT Pd (mW/cm^2)                                      Limit
               Band (GHz)           (mW/cm^2)                                  BT Pd (mW/cm^2)
                 2.3-2.4
                 2.4-2.5
                 2.5-2.7              0.500                  0.020                  0.520                1.000
                 3.3-3.8
                5.15-5.85


                          Table 7: (WLAN or WiMAX) + BT Collocated MPE Calculation




WLAN /       WLAN /                    (WLAN /                                                       (850 MHz
                         FCC MPE                    850 MHz           FCC MPE     (WWAN 850
WiMAX        WiMAX +                 WiMAX + BT                                                  WWAN + WLAN
                           Limit                   WWAN Pd              Limit     MHz) / MPE                      Limit   Pass/Fail
  Band        BT Pd                   Pd) / (MPE                                                  / WiMAX + BT
                        (mW/cm^2)                  (mW/cm^2)         (mW/cm^2)      Limit)
 (GHz)      (mW/cm^2)                   Limit)                                                        fraction)
 2.3-2.4
 2.4-2.5
 2.5-2.7      0.520       1.000         0.520        0.126             0.549         0.230           0.750        1.000     Pass
 3.3-3.8
5.15-5.85



                 Table 8: WWAN 850MHz + WLAN / WiMAX + BT Collocated MPE Calculation




WLAN /       WLAN /                    (WLAN /                                                      (1900 MHz
                         FCC MPE                    1900 MHz          FCC MPE       (WWAN
WiMAX        WiMAX +                 WiMAX + BT                                                  WWAN + WLAN
                           Limit                   WWAN Pd              Limit     1900 MHz) /                     Limit   Pass/Fail
  Band        BT Pd                   Pd) / (MPE                                                  / WiMAX + BT
                        (mW/cm^2)                  (mW/cm^2)         (mW/cm^2)    MPE Limit)
 (GHz)      (mW/cm^2)                   Limit)                                                       fraction)
 2.3-2.4
 2.4-2.5
 2.5-2.7      0.520       1.000         0.520        0.126             1.000         0.126           0.646        1.000     Pass
 3.3-3.8
5.15-5.85




                Table 9: WWAN 1900MHz + WLAN / WiMAX + BT Collocated MPE Calculation


WLAN /       WLAN /                    (WLAN /                                               (700 MHz
                         FCC MPE                    700 MHz     FCC MPE    (WWAN 700
WiMAX        WiMAX +                 WiMAX + BT                                          WWAN + WLAN
                           Limit                   WWAN Pd        Limit    MHz) / MPE                     Limit   Pass/Fail
  Band        BT Pd                   Pd) / (MPE                                          / WiMAX + BT
                        (mW/cm^2)                  (mW/cm^2)   (mW/cm^2)     Limit)
 (GHz)      (mW/cm^2)                   Limit)                                                fraction)
 2.3-2.4
 2.4-2.5
 2.5-2.7      0.520        1.000        0.520        0.199       0.469        0.424          0.944        1.000     Pass
 3.3-3.8
5.15-5.85


                Table 10: WWAN 700MHz + WLAN / WiMAX + BT Collocated MPE Calculation



                             FCC
WLAN /                                 (WLAN /                                              (1700 MHz
               WLAN /        MPE                    2500 MHz    FCC MPE      (WWAN
WiMAX                                WiMAX + BT                                          WWAN + WLAN
            WiMAX + BT       Limit                 WWAN Pd        Limit    1700 MHz) /                    Limit   Pass/Fail
 Band                                 Pd) / (MPE                                          / WiMAX + BT
            Pd (mW/cm^2)    (mW/c                  (mW/cm^2)   (mW/cm^2)   MPE Limit)
(GHz)                                   Limit)                                               fraction)
                             m^2)
 2.3-2.4
 2.4-2.5
 2.5-2.7        0.520        1.000      0.520        0.397       1.000        0.397          0.917        1.000     Pass
 3.3-3.8
5.15-5.85


               Table 11: WWAN 2500MHz + WLAN / WiMAX + BT Collocated MPE Calculation



                             FCC
WLAN /                                 (WLAN /                                              (1700 MHz
               WLAN /        MPE                    1700 MHz    FCC MPE      (WWAN
WiMAX                                WiMAX + BT                                          WWAN + WLAN
            WiMAX + BT       Limit                 WWAN Pd        Limit    1700 MHz) /                    Limit   Pass/Fail
 Band                                 Pd) / (MPE                                          / WiMAX + BT
            Pd (mW/cm^2)    (mW/c                  (mW/cm^2)   (mW/cm^2)   MPE Limit)
(GHz)                                   Limit)                                               fraction)
                             m^2)
 2.3-2.4
 2.4-2.5
 2.5-2.7        0.520        1.000      0.520        0.199       1.000        0.199          0.719        1.000     Pass
 3.3-3.8
5.15-5.85


               Table 12: WWAN 1700MHz + WLAN / WiMAX + BT Collocated MPE Calculation


            5. Conclusion
               Based on FCC OET Bulletin 65 Supplement C and 47 CFR §2.1091, the analysis
               concludes that the AR7550 wireless module, when transmitting either in standalone
               or simultaneously with other co-located radio transmitters within a host device, is
               compliant with the FCC/IC RF exposure requirements in mobile exposure condition,
               provided the conducted power and antenna gain do not exceed the limits in Table
               13 for each given frequency band per wireless technology.


                                                            Maximum        Maximum Antenna Gain (dBi)
                       Technoloty       Frequency (MHz)     Conducted
                                                           Power (dBm)     Standalone       Collocated
                                            824-849           25.0            6.5              3.0
                         CDMA
                                           1850-1910          25.0            3.0              3.0

                                           824 -849           24.5            6.5              3.0
   AR7550




                         UMTS
                                          1850 -1910          24.5            3.0              3.0

                                           777 -787           24.0            9.0              6.0
                          LTE              2500-2570          24.0            9.0              9.0

                                          1710 -1755          24.0            6.0              6.0
                 WLAN                     2400 -2500          29.0                             5.0
                 WLAN                     5150 -5850          29.0                             5.0
Transmitters
 Collocated




                                WiMAX     2300 -2400           29                              5.0
                                WiMAX     2500 -2700           29                              5.0
                                WiMAX     3300 -3800           29                              5.0
                  BT             BT       2400 -2500           15                              5.0



            Table 13: Summary of Maximum Conducted Power and Antenna Gain



Document Created: 2013-05-08 16:31:22