SAR attachment 1 - sysverif plots

FCC ID: N7NAC402

RF Exposure Info

Download: PDF
FCCID_1068255

                                                                                     Date/Time: 1/26/2009 9:55:25 AM

Test Laboratory: Compliance Certification Services

System Performance Check - D1900V2
DUT: Dipole; Type: D1900V2; Serial: 5d043

Communication System: System Check Signal - CW; Frequency: 1900 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1900 MHz; σ = 1.59 mho/m; εr = 51.2; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 25.0 deg. C; Liquid Temperature: 24.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(8.7, 8.7, 8.7); Calibrated: 4/23/2008
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 10/20/2008
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:XXXX
- Measurement SW: DASY4, V4.7 Build 71; Postprocessing SW: SEMCAD, V1.8 Build 184



d=10mm, Pin=250mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 9.14 mW/g

d=10mm, Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 87.4 V/m; Power Drift = 0.044 dB
Peak SAR (extrapolated) = 70.4 W/kg
SAR(1 g) = 38.4 mW/g; SAR(10 g) = 20 mW/g
Normalized to target power = 1 W and actual power = 0.25 W
Maximum value of SAR (measured) = 48.7 mW/g


                                                                                 Date/Time: 1/26/2009 10:12:09 AM

Test Laboratory: Compliance Certification Services

System Performance Check - D1900V2
DUT: Dipole; Type: D1900V2; Serial: 5d043

Communication System: System Check Signal - CW; Frequency: 1900 MHz;Duty Cycle: 1:1



d=10mm, Pin=250mW/Z Scan (1x1x34): Measurement grid: dx=20mm, dy=20mm, dz=3mm
Maximum value of SAR (measured) = 12.2 mW/g


                                                                                      Date/Time: 2/3/2009 9:43:13 AM

Test Laboratory: Compliance Certification Services

System Performance Check - D835V2
DUT: Dipole; Type: D835V2; Serial: 4d002

Communication System: System Check Signal - CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium parameters used: f = 835 MHz; σ = 0.951 mho/m; εr = 53.9; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 25.0 deg. C; Liquid Temperature: 24.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.22, 10.22, 10.22); Calibrated: 4/23/2008
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 10/20/2008
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:XXXX
- Measurement SW: DASY4, V4.7 Build 71; Postprocessing SW: SEMCAD, V1.8 Build 184



d=15mm, Pin=250mW/Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 2.94 mW/g

d=15mm, Pin=250mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 55.9 V/m; Power Drift = 0.015 dB
Peak SAR (extrapolated) = 15.1 W/kg
SAR(1 g) = 10.1 mW/g; SAR(10 g) = 6.66 mW/g
Normalized to target power = 1 W and actual power = 0.25 W
Maximum value of SAR (measured) = 11.8 mW/g


                                                                                     Date/Time: 2/3/2009 10:01:17 AM

Test Laboratory: Compliance Certification Services

System Performance Check - D835V2
DUT: Dipole; Type: D835V2; Serial: 4d002

Communication System: System Check Signal - CW; Frequency: 835 MHz;Duty Cycle: 1:1



d=15mm, Pin=250mW/Z Scan (1x1x34): Measurement grid: dx=20mm, dy=20mm, dz=3mm
Maximum value of SAR (measured) = 2.97 mW/g



Document Created: 2009-02-03 17:21:48