SAR Report

FCC ID: N7NAC402

RF Exposure Info

Download: PDF
FCCID_1068253

     FCC OET BULLETIN 65 SUPPLEMENT C
         INDUSTRY CANADA RSS-102

         SAR EVALUATION REPORT

                   FOR

PCA, EVDO MINI-PCI EXPRESS CARD CDMA MODEM

              MODEL: AC402

             FCC ID: N7NAC402
              IC: 2417C-AC402

        REPORT NUMBER: 08U12312-5

       ISSUE DATE: FEBRUARY 11, 2009


                Prepared for

           SIERRA WIRELESS INC.
              2290 COSMOS CT.
            CARLSBAD, CA 92011

                Prepared by

    COMPLIANCE CERTIFICATION SERVICES
           47173 BENICIA STREET
         FREMONT, CA 94538, USA


REPORT NO: 08U12312-5                                     DATE: February 11, 2009          FCC ID: N7NAC402

Revision History
 Rev.             Issue Date                         Revisions                                Revised By

 --               February 11, 2009                  Initial Issue                            --




COMPLIANCE CERTIFICATION SERVICES                                                                  Page: 2 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                          DATE: February 11, 2009                                      FCC ID: N7NAC402

                                                          TABLE OF CONTENTS


1      ATTESTATION OF TEST RESULTS................................................................................................... 4
2      TEST METHODOLOGY....................................................................................................................... 5
3      FACILITIES AND ACCREDITATION ................................................................................................... 5
4      CALIBRATION AND UNCERTAINTY .................................................................................................. 6
     4.1      MEASURING INSTRUMENT CALIBRATION ............................................................................. 6
     4.2      MEASUREMENT UNCERTAINTY .............................................................................................. 6
5      DEVICE UNDER TEST (DUT) DESCRIPTION ................................................................................... 7
     5.1      DESCRIPTION OF EUT .............................................................................................................. 7
6      SYSTEM DESCRIPTION ..................................................................................................................... 8
     6.1      COMPOSITION OF INGREDIENTS FOR TISSUE SIMULATING LIQUIDS .............................. 9
7      SIMULATING LIQUID CHECK........................................................................................................... 10
     7.1      SIMULATING LIQUID PARAMETER CHECK RESULT............................................................ 11
8      SYSTEM PERFORMANCE CHECK .................................................................................................. 13
     8.1      SYSTEM PERFORMANCE CHECK RESULTS........................................................................ 14
9      OUTPUT POWER VERIFICATION.................................................................................................... 15
     9.1      RF POWER OUTPUT FOR WWAN .......................................................................................... 15
     9.2      RF POWER OUTPUT FOR 1XRTT........................................................................................... 15
     9.3      RF POWER OUTPUT FOR EV-DO REL 0................................................................................ 17
     9.4      RF POWER OUTPUT FOR EV-DO REV A............................................................................... 18
10     SAR MEASURMENT RESULTS FOR WWAN .................................................................................. 19
     10.1 PCS BAND................................................................................................................................. 19
     10.2 CELL BAND ............................................................................................................................... 20
11     EQUIPMENT LIST AND CALIBRATION............................................................................................ 23
12     ATTACHMENTS................................................................................................................................. 24
13     SETUP PHOTOS ................................................................................................................................ 25
14     EUT PHOTOS .................................................................................................................................... 26




COMPLIANCE CERTIFICATION SERVICES                                                                                                    Page: 3 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                      FCC ID: N7NAC402

1     ATTESTATION OF TEST RESULTS
    COMPANY NAME:                              SIERRA WIRELESS INC.
                                               2290 COSMOS CT.
                                               CARLSBAD, CA 92011
    EUT DESCRIPTION:                           CDMA/1x EVDO Rel 0 / EVDO Rev. A
    MODEL:                                     AC402
    DEVICE CATEGORY:                           Portable
    EXPOSURE CATEGORY:                         General Population/Uncontrolled Exposure
    DATE TESTED:                               January 26 and February 3, 2009
 THE HIGHEST SAR VALUES:
                                                                                                               1g_Limit
    FCC / IC Rule Parts           Frequency Range [MHz]               The Highest 1g_SAR Values (mW/g)         (mW/g)

      22H / RSS-102                         824 - 849                            1.04 (Express Card)              1.6

      24E / RSS-102                       1850 - 1910                            1.51 (Express Card)              1.6


                                      REFERENCE STANDARDS/TEST PROCEDURES
 FCC OET BULLETIN 65 SUPPLEMENT C, and the following specific FCC Test Procedures.
     o KDB 941225 D01 SAR Test for 3G Devices
     o KDB447498 Mobile and Portable Device RF Exposure Procedures and Equipment Authorization
        Policies
 IC RSS 102 Issue 2
 Compliance Certification Services, Inc. (CCS) tested the above equipment in accordance with the
 requirements set forth in the above standards. All indications of Pass/Fail in this report are opinions expressed
 by CCS based on interpretations and/or observations of test results. The test results show that the equipment
 tested is capable of demonstrating compliance with the requirements as documented in this report.
 Note: The results documented in this report apply only to the tested sample, under the conditions and modes
 of operation as described herein. This document may not be altered or revised in any way unless done so by
 CCS and all revisions are duly noted in the revisions section. Any alteration of this document not carried out
 by CCS will constitute fraud and shall nullify the document. No part of this report may be used to claim
 product certification, approval, or endorsement by NVLAP, NIST, or any government agency.
 Approved & Released For CCS By:                                          Tested By:




 SUNNY SHIH                                                               CAROL BAUMANN
 EMC SUPERVISOR                                                           EMC ENGINEER
 COMPLIANCE CERTIFICATION SERVICES                                        COMPLIANCE CERTIFICATION SERVICES




COMPLIANCE CERTIFICATION SERVICES                                                                           Page: 4 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009          FCC ID: N7NAC402

2     TEST METHODOLOGY
The tests documented in this report were performed in accordance with FCC OET Bulletin 65 Supplement
C, IC RSS 102 Issue 2 and the following specific FCC Test Procedures.
    o KDB 941225 D01 SAR Test for 3G Devices
    o KDB447498 Mobile and Portable Device RF Exposure Procedures and Equipment Authorization
        Policies


3     FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 47173 Benicia Street,
Fremont, California, USA.
CCS is accredited by NVLAP, Laboratory Code 200065-0. The full scope of accreditation can be viewed
at http://ts.nist.gov/Standards/scopes/2000650.htm.




COMPLIANCE CERTIFICATION SERVICES                                                               Page: 5 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                      DATE: February 11, 2009                               FCC ID: N7NAC402

4     CALIBRATION AND UNCERTAINTY

4.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report have been calibrated in
accordance with the manufacturer's recommendations, and is traceable to recognized national standards.

4.2 MEASUREMENT UNCERTAINTY
Measurement uncertainty for 300 MHz – 3000 MHz
                                                                           Probe                                     Std. Unc.(±%)
                 Uncertainty component                         Tol. (±%)            Div.    Ci (1g)   Ci (10g)
                                                                            Dist.                                  Ui (1g)    Ui(10g)
Measurement System
Probe Calibration                                                4.80        N        1       1          1          4.80       4.80
Axial Isotropy                                                   4.70        R      1.732   0.707      0.707        1.92       1.92
Hemispherical Isotropy                                           9.60        R      1.732   0.707      0.707        3.92       3.92
Boundary Effects                                                 1.00        R      1.732     1          1          0.58       0.58
Linearity                                                        4.70        R      1.732     1          1          2.71       2.71
System Detection Limits                                          1.00        R      1.732     1          1          0.58       0.58
Readout Electronics                                              1.00        N        1       1          1          1.00       1.00
Response Time                                                    0.80        R      1.732     1          1          0.46       0.46
Integration Time                                                 2.60        R      1.732     1          1          1.50       1.50
RF Ambient Conditions - Noise                                    1.59        R      1.732     1          1          0.92       0.92
RF Ambient Conditions - Reflections                              0.00        R      1.732     1          1          0.00       0.00
Probe Positioner Mechnical Tolerance                             0.40        R      1.732     1          1          0.23       0.23
Probe Positioning With Respect to Phantom Shell                  2.90        R      1.732     1          1          1.67       1.67
Extrapolation, interpolation, and integration algorithms for
max. SAR evaluation                                              3.90        R      1.732     1          1          2.25       2.25
Test sample Related
Test Sample Positioning                                          1.10        N        1       1          1          1.10       1.10
Device Holder Uncertainty                                        3.60        N        1       1          1          3.60       3.60
Power and SAR Drift Measurement                                  5.00        R      1.732     1          1          2.89       2.89
Phantom and Tissue Parameters
Phantom Uncertainty                                              4.00        R      1.732      1         1          2.31       2.31
Liquid Conductivity - Target                                     5.00        R      1.732    0.64      0.43         1.85       1.24
Liquid Conductivity - Meas.                                      8.60        N        1      0.64      0.43         5.50       3.70
Liquid Permittivity - Target                                     5.00        R      1.732     0.6      0.49         1.73       1.41
Liquid Permittivity - Meas.                                      3.30        N        1       0.6      0.49         1.98       1.62
Combined Standard Uncertainty                                                        RSS                           11.44       10.49
Expanded Uncertainty (95% Confidence Interval)                                       K=2                           22.87       20.98
Notesfor table
1. Tol. - tolerance in influence quaitity
2. N - Nomal
3. R - Rectangular
4. Div. - Divisor used to obtain standard uncertainty
5. Ci - is te sensitivity coefficient




COMPLIANCE CERTIFICATION SERVICES                                                                                      Page: 6 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                FCC ID: N7NAC402

5     DEVICE UNDER TEST (DUT) DESCRIPTION

5.1     DESCRIPTION OF EUT


PCA, EVDO MINI-PCI EXPRESS CARD CDMA MODEM
Network:                               3G-CDMA2000 EV-DO Rel 0, Rev A. This device also supports 1x RTT
                                       voice and/or data operations
Host Device:                           Toshiba Satellite P105-S9337 (for Express Card)
                                       Toshiba Satellite A105-S4344 (for Card Bus PC Card)
Antenna(s):                            Internal
Power Supply:                          Power is supplied through laptop computer (host device)




COMPLIANCE CERTIFICATION SERVICES                                                                     Page: 7 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009          FCC ID: N7NAC402

6     SYSTEM DESCRIPTION




The DASY4 system for performing compliance tests consists of the following items:
     •    A standard high precision 6-axis robot (Stäubli RX family) with controller, teach pendant and
          software. An arm extension for accommodating the data acquisition electronics (DAE).
     •    A dosimetric probe, i.e., an isotropic E-field probe optimized and calibrated for usage in tissue
          simulating liquid. The probe is equipped with an optical surface detector system.
     •    A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing,
          AD-conversion, offset measurements, mechanical surface detection, collision detection, etc. The
          unit is battery powered with standard or rechargeable batteries. The signal is optically transmitted
          to the EOC.
     •    The function of the measurement server is to perform the time critical tasks such as signal
          filtering, control of the robot operation and fast movement interrupts.
     •    A probe alignment unit which improves the (absolute) accuracy of the probe positioning.
     •    A computer operating Windows 2000 or Windows XP.
     •    DASY4 software.
     •    Remote controls with teach pendant and additional circuitry for robot safety such as warning
          lamps, etc.
     •    The SAM twin phantom enabling testing left-hand and right-hand usage.
     •    The device holder for handheld mobile phones.
     •    Tissue simulating liquid mixed according to the given recipes.
     •    Validation dipole kits to validate the proper functioning of the system.




COMPLIANCE CERTIFICATION SERVICES                                                                Page: 8 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                      FCC ID: N7NAC402

6.1 COMPOSITION OF INGREDIENTS FOR TISSUE SIMULATING LIQUIDS
The following tissue formulations are provided for reference only as some of the parameters have not
been thoroughly verified. The composition of ingredients may be modified accordingly to achieve the
desired target tissue parameters required for routine SAR evaluation.
       Ingredients                                                        Frequency (MHz)
     (% by weight)                     450                   835                  915            1900            2450
      Tissue Type                Head Body             Head Body            Head Body        Head Body      Head Body
          Water                  38.56 51.16           41.45 52.4           41.05 56.0       54.9    40.4   62.7     73.2
       Salt (NaCl)                3.95     1.49         1.45      1.4        1.35     0.76   0.18     0.5    0.5     0.04
          Sugar                  56.32 46.78            56.0     45.0        56.5 41.76       0.0    58.0    0.0      0.0
          HEC                     0.98     0.52         1.0       1.0         1.0     1.21    0.0     1.0    0.0      0.0
       Bactericide                0.19     0.05         0.1       0.1        0.1      0.27    0.0     0.1    0.0      0.0
      Triton X-100                0.0      0.0           0.0      0.0        0.0      0.0     0.0     0.0   36.8      0.0
          DGBE                     0.0     0.0           0.0      0.0         0.0     0.0    44.92    0.0    0.0     26.7
   Dielectric Constant           43.42 58.0            42.54 56.1            42.0     56.8   39.9    54.0   39.8     52.5
   Conductivity (S/m)             0.85     0.83         0.91     0.95        1.0      1.07   1.42    1.45   1.88     1.78

Salt: 99+% Pure Sodium Chloride              Sugar: 98+% Pure Sucrose
Water: De-ionized, 16 MΩ+ resistivity        HEC: Hydroxyethyl Cellulose
DGBE: 99+% Di(ethylene glycol) butyl ether, [2-(2-butoxyethoxy)ethanol]
Triton X-100 (ultra pure): Polyethylene glycol mono [4-(1,1, 3, 3-tetramethylbutyl)phenyl]ether




COMPLIANCE CERTIFICATION SERVICES                                                                            Page: 9 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                FCC ID: N7NAC402

7     SIMULATING LIQUID CHECK
The simulating liquids should be checked at the beginning of a series of SAR measurements to determine
of the dielectric parameters are within the tolerances of the specified target values. The relative
permittivity and conductivity of the tissue material should be within ± 5% of the values given in the table
below.

       Dielectric Probe




                                                       Network Analyzer                    Personal Computer
                                                  Set-up for liquid parameters check
Reference Values of Tissue Dielectric Parameters for Head and Body Phantom
(for 150 – 3000 MHz and 5800 MHz)
The head tissue dielectric parameters recommended by the IEEE SCC-34/SC-2 in IEEE Standard 1528
have been incorporated in the following table. These head parameters are derived from planar layer
models simulating the highest expected SAR for the dielectric properties and tissue thickness variations
in a human head. Other head and body tissue parameters that have not been specified in P1528 are
derived from the tissue dielectric parameters computed from the 4-Cole-Cole equations and extrapolated
according to the head parameters specified in IEEE Standard 1528.
                                                         Head                             Body
         Target Frequency (MHz)
                                                  εr           σ (S/m)              εr         σ (S/m)
                    150                         52.3              0.76            61.9          0.80
                    300                         45.3              0.87            58.2          0.92
                    450                         43.5              0.87            56.7          0.94
                    835                         41.5              0.90             55.2         0.97
                    900                         41.5              0.97            55.0          1.05
                    915                         41.5              0.98            55.0          1.06
                   1450                         40.5              1.20            54.0          1.30
                   1610                         40.3              1.29            53.8          1.40
                1800 – 2000                     40.0              1.40            53.3          1.52
                   2450                         39.2              1.80            52.7          1.95
                   3000                         38.5              2.40            52.0          2.73
                   5800                         35.3              5.27            48.2          6.00
                                                                                        3
                        (εr = relative permittivity, σ = conductivity and ρ = 1000 kg/m )




COMPLIANCE CERTIFICATION SERVICES                                                                     Page: 10 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                            FCC ID: N7NAC402


7.1 SIMULATING LIQUID PARAMETER CHECK RESULT
Simulating Liquid Dielectric Parameters Check Result @ Muscle 1900 MHz
Room Ambient Temperature = 25°C; Relative humidity = 46%                                      Measured by: Carol Baumann

        Simulating Liquid
                                                  Parameters                       Measured     Target   Deviation (%)   Limit (%)
      f (MHz)      Depth (cm)
                                 e'     51.3365      Relative Permittivity (єr):   51.3365       53.3       -3.68          ±5
       1900            15
                                 e"     14.9148                Conductivity (σ):   1.57649       1.52        3.72          ±5
 Liquid Check
 Ambient temperature: 25 deg. C; Liquid temperature: 24 deg. C
 January 26, 2009 09:28 AM
 Frequency              e'                       e''
 1710000000.             52.4543                  14.1112
 1720000000.             52.3621                  14.0927
 1730000000.             52.2857                  14.1094
 1740000000.             52.2716                  14.1559
 1750000000.             52.2357                  14.3105
 1760000000.             52.1284                  14.4801
 1770000000.             51.9942                  14.5821
 1780000000.             51.9005                  14.5939
 1790000000.             51.8749                  14.5898
 1800000000.             51.8833                  14.5901
 1810000000.             51.8582                  14.5573
 1820000000.             51.8315                  14.4829
 1830000000.             51.8707                  14.4640
 1840000000.             51.8767                  14.5555
 1850000000.             51.8016                  14.7165
 1860000000.             51.6060                  14.8423
 1870000000.             51.4017                  14.8839
 1880000000.             51.3326                  14.8565
 1890000000.             51.3204                  14.8766
 1900000000.             51.3365                  14.9148
 1910000000.             51.3182                  14.9724
 The conductivity (σ) can be given as:
 σ = ωε0 e''= 2 π f ε0 e''
 where     f = target f * 106
          ε0 = 8.854 * 10-12




COMPLIANCE CERTIFICATION SERVICES                                                                                   Page: 11 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                             FCC ID: N7NAC402

Simulating Liquid Dielectric Parameters Check Result @ Muscle 835 MHz
Room Ambient Temperature = 25°C; Relative humidity = 32%                                      Measured by: Carol Baumann

         Simulating Liquid
                                                  Parameters                       Measured     Target   Deviation (%)   Limit (%)
       f (MHz)     Depth (cm)
                                  e'    53.8969      Relative Permittivity (єr):   53.8969       55.2       -2.36          ±5
        835            15
                                  e"    20.4694                Conductivity (σ):   0.95085       0.97       -1.97          ±5
 Liquid Check
 Ambient temperature: 25 deg. C; Liquid temperature: 24 deg. C
 February 03, 2009 09:13 AM
 Frequency              e'                       e''
 750000000.              54.7316                  20.8737
 755000000.              54.7063                  20.8943
 760000000.              54.7105                  20.9283
 765000000.              54.7505                  20.9611
 770000000.              54.7557                  20.9581
 775000000.              54.7269                  20.9896
 780000000.              54.7100                  21.0515
 785000000.              54.6663                  21.0988
 790000000.              54.6311                  21.1657
 795000000.              54.5175                  21.1680
 800000000.              54.3753                  21.1807
 805000000.              54.2642                  21.1150
 810000000.              54.1301                  20.9966
 815000000.              54.0346                  20.8886
 820000000.              53.9714                  20.7593
 825000000.              53.9059                  20.6378
 830000000.              53.8802                  20.5638
 835000000.              53.8969                  20.4694
 840000000.              53.8270                  20.4073
 845000000.              53.8092                  20.4247
 850000000.              53.8005                  20.4058
 855000000.              53.8031                  20.4150
 860000000.              53.7897                  20.4084
 865000000.              53.7479                  20.4660
 870000000.              53.7458                  20.5400
 875000000.              53.7060                  20.5957
 880000000.              53.6525                  20.6670
 885000000.              53.5839                  20.7224
 890000000.              53.4715                  20.7421
 895000000.              53.3551                  20.7740
 900000000.              53.2514                  20.6866
 The conductivity (σ) can be given as:
 σ = ωε0 e''= 2 π f ε0 e''
 where     f = target f * 106
          ε0 = 8.854 * 10-12




COMPLIANCE CERTIFICATION SERVICES                                                                                    Page: 12 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                      FCC ID: N7NAC402

8     SYSTEM PERFORMANCE CHECK
The system performance check is performed prior to any usage of the system in order to guarantee
reproducible results. The system performance check verifies that the system operates within its
specifications of ±10%.
System Performance Check Measurement Conditions
•    The measurements were performed in the flat section of the SAM twin phantom filled with Body
     simulating liquid of the following parameters.
•    The DASY4 system with an Isotropic E-Field Probe EX3DV3-SN: 3531 was used for the
     measurements.
•    The dipole was mounted on the small tripod so that the dipole feed point was positioned below the
     center marking of the flat phantom section and the dipole was oriented parallel to the body axis (the
     long side of the phantom). The standard measuring distance was 10 mm (above 1 GHz) and
     15 mm (below 1 GHz) from dipole center to the simulating liquid surface.
•    The coarse grid with a grid spacing of 15 mm was aligned with the dipole.
     For 5 GHz band - The coarse grid with a grid spacing of 10 mm was aligned with the dipole.
•    Special 7 x 7 x 7 fine cube was chosen for cube integration(dx=dy=5mm; dz=5mm).
     For 5 GHz band - Special 7 x 7 x 7 fine cube was chosen for cube integration
     (dx=dy=4.3mm; dz=3mm)
•    Distance between probe sensors and phantom surface was set to 3 mm.
     For 5 GHz band - Distance between probe sensors and phantom surface was set to 2.5 mm
•    The dipole input power (forward power) was 250 mW±3%.
•    The results are normalized to 1 W input power.

Reference SAR Values for body-tissue
In the table below, the numerical reference SAR values of a SPEAG validation dipoles placed below the
flat phantom filled with body-tissue simulating liquid are given. The reference SAR values were
calculated using the finite-difference time-domain method and the geometry parameters.

                             Distance              Frequency               SAR (1g)        SAR (10g)       SAR (peak)
    Dipole Type
                               (mm)                  (MHz)                  [W/kg]          [W/kg]           [W/kg]
     D450V2                     15                    450                    5.01            3.36             7.22
     D835V2                     15                     835                   9.71            6.38             14.1
     D900V2                     15                    900                    11.1            7.17             16.3
     D1450V2                    10                    1450                   29.6            16.6             49.8
     D1800V2                    10                    1800                   38.5            20.3             67.5
     D1900V2                    10                    1900                   39.8            20.8             69.6
     D2000V2                    10                    2000                   40.9            21.2             71.5
     D2450V2                    10                    2450                   51.2            23.7             97.6
Note: All SAR values normalized to 1 W forward power.




COMPLIANCE CERTIFICATION SERVICES                                                                          Page: 13 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                               FCC ID: N7NAC402

8.1     SYSTEM PERFORMANCE CHECK RESULTS
System Validation Dipole: D1900V2 SN:5d043
The dipole input power (forward power): 250 mW
Results
Date: January 26, 2009
Ambient Temperature = 25°C; Relative humidity = 46%                                             Measured by: Carol Baumann
          B o d y S im u la tin g L iq u id                  N o r m a liz e d                          D e v ia tio n       L im it
                                                                                           T a rg e t
   f (M H z )      T e m p . ( ° C ) D e p th (c m )            to 1 W                                      (% )              (% )

                                                           1g            3 8 .4             3 9 .8         - 3 .5 2           ± 10
      1900               24                15
                                                          10g              20               2 0 .8         - 3 .8 5           ± 10


System Validation Dipole: D835V2 SN: 4d002
The dipole input power (forward power): 250 mW
Results
Date: February 3, 2009
Ambient Temperature = 25°C; Relative humidity = 32%                                             Measured by: Carol Baumann
          B o d y S im u la tin g L iq u id                  N o r m a liz e d                          D e v ia tio n       L im it
                                                                                           T a rg e t
   f (M H z )      T e m p . ( ° C ) D e p th (c m )            to 1 W                                      (% )              (% )

                                                           1g            1 0 .1              9 .7          4 .0 2             ± 10
      2450               24                15
                                                          10g            6 .6 6              6 .4          4 .3 9             ± 10




COMPLIANCE CERTIFICATION SERVICES                                                                                        Page: 14 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                  FCC ID: N7NAC402

9     OUTPUT POWER VERIFICATION

    9.1 RF POWER OUTPUT FOR WWAN
Maximum output power is verified on the Low, Middle and High channels according to procedures in
section 4.4.5.2 of 3GPP2 C.S0011/TIA-98-E for 1xRTT, section 3.1.2.3.4 of 3GPP2 C.S0033-0/TIA-866
for Rel. 0 and section 4.3.4 of 3GPP2 C.S0033-A for Rev. A

     9.2 RF POWER OUTPUT FOR 1xRTT
This procedure assumes the Agilent 8960 Test Set has the following applications installed and with valid
license.
Application                   Rev, License
CDMA2000 Mobile Test          B.13.08, L
   • Call Setup > Shift & Preset
   • Cell Info > Cell Parameters > System ID (SID) > 8
                                 > Network ID (NID) > 65535
   • Protocol Rev > 6 (IS-2000-0)
   • Radio Config (RC) > Please see following table or details
   • FCH Service Option (SO) Setup > Please see following table or details
   • Traffic Data Rate > Full
   • TDSO SCH Info > F-SCH Parameters > F-SCH Data Rate > 153.6 kbps
                       > R-SCH Parameters > R-SCH Data Rate > 153.6 kbps
   • Rvs Power Ctrl > Active bits
      o Rvs Power Ctrl > All Up bits (Maximum TxPout)

RF Power Output Results for 1xRTT
RF Power Output for 1xRTT - Cell Band
     Radio                                                          Conducted Output Power (dBm)
  Configuration      Service Option                Ch. 1013/824.7MHz    Ch. 384/836.52MHz       Ch. 777/848.31MHz
     (RC)                  (SO)                    Average     Peak     Average       Peak     Average       Peak
                         1 (Voice)
                       2 (Loopback)                 23.75           28.41           23.6   28.36    23.6      28.3
      RC1
                         3 (Voice)
  (Fwd1, Rvs1)
                      55 (Loopback)                 23.80           28.57           23.6   28.42   23.65      28.25
                        68 (Voice)
                       9 (Loopback)                 23.65           28.43           23.5   28.28   23.50      28.20
      RC2               17 (Voice)
  (Fwd2, Rvs2)        55 (Loopback)                 23.70           28.53           23.5   28.3     23.5      28.09
                      32768 (Voice)
                         1 (Voice)
                       2 (Loopback)                  23.6           27.96          23.40   27.84   23.50      27.68
      RC3                3 (Voice)
  (Fwd3, Rvs3)        55 (Loopback)                 23.60           28.07           23.6   27.81   23,60      27.67
                      32 (+ F-SCH)                  23.80           27.98          23.50   27.71    23.6      27.65
                        32 (+ SCH)                   23.6           27.89          23.50   28.07   23.75      28.00
                         1 (Voice)
                       2 (Loopback)                  23,6           27.96          23.50   27.82    23.6      27.78
      RC4                3 (Voice)
  (Fwd4, Rvs3)        55 (Loopback)                 23.60           27.84           23.5   27.87    23.5      27.88
                      32 (+ F-SCH)                  23.70           28.05           23.5   27.86   23.60      27.78
                        32 (+ SCH)                  23.60           28.06          23.40   27.71    23.6      27.76
                       9 (Loopback)                 23.80           28.05           23.5   27.73   23.50      27.72
      RC5               17 (Voice)
  (Fwd5, Rvs4)        55 (Loopback)                  23.6           28.02           23.4   27.77   23.50      27.71
                      32768 (Voice)



COMPLIANCE CERTIFICATION SERVICES                                                                      Page: 15 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                  FCC ID: N7NAC402

RF Power Output Results for 1xRTT
RF Power Output for 1xRTT - PCS Band
     Radio                                                           Conducted Output Power (dBm)
  Configuration      Service Option                Ch. 25/1851.25MHz      Ch. 600/1880MHz       Ch. 1175/1908.75 MHz
     (RC)                  (SO)                    Average      Peak     Average       Peak      Average      Peak
                         1 (Voice)
                      2 (Loopback)                  23.20           28.22          23.40   28.95   23.30      27.97
      RC1
                         3 (Voice)
  (Fwd1, Rvs1)
                     55 (Loopback)                   23.4           28.27           23.5   28.33    23.4      27.96
                        68 (Voice)
                      9 (Loopback)                   23.5           28.28           23.6   28.50    23.5       28
      RC2               17 (Voice)
  (Fwd2, Rvs2)       55 (Loopback)                   23.3           28.22           23.5   28.44    23.4      28.11
                      32768 (Voice)
                         1 (Voice)
                      2 (Loopback)                   23.5           27.90           23.6   28.01    23.4      27.76
      RC3                3 (Voice)
  (Fwd3, Rvs3)       55 (Loopback)                   23.5           27.87          23.60    28.1    23.4      27.62
                      32 (+ F-SCH)                   23.4            28            23.40   28.21   23.50      27.77
                       32 (+ SCH)                   23.50           27.96          23.60   28.02   23.50      28.07
                         1 (Voice)
                      2 (Loopback)                   23.5           27.94           23.5   28.05    23.4      27.66
      RC4                3 (Voice)
  (Fwd4, Rvs3)       55 (Loopback)                   23.5           27.97          23.50   28.12    23.5      27.79
                      32 (+ F-SCH)                   23.5           27.98          23.50   27.91   23.60      27.93
                       32 (+ SCH)                   23.50           27.97          23.50   28.11    23.5      27.83
                      9 (Loopback)                  23.4            28.07          23.50   27.88    23.4       27.7
      RC5               17 (Voice)
  (Fwd5, Rvs4)       55 (Loopback)                    235           27.99          23.60   28.06   23..4      27.65
                      32768 (Voice)




COMPLIANCE CERTIFICATION SERVICES                                                                      Page: 16 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                      FCC ID: N7NAC402


     9.3 RF POWER OUTPUT FOR EV-DO REL 0
This procedure assumes the Agilent 8960 Test Set has the following applications installed and with valid
license.
Application                 Rev, License
1xEV-DO Terminal Test       A.09.13

EVDO Release 0 - RTAP
• Call Setup > Shift & Preset
• Call Control:
   o Access Network Info > Cell Parameters > Sector ID > 00000000 > Subnet Mask > 0
   o Generator Info > Termination Parameters > Max Forward Packet Duration > 16 Slots
• Call Parms:
   o Cell Power > -105.5 dBm/1.23 MHz
   o Cell Band > (Select US Cellular or US PCS)
   o Channel > (Enter channel number)
   o Application Config > Enhanced Test Application Protocol > RTAP
   o RTAP Rate > 153.6 kbps
   o Rvs Power Ctrl > Active bits
   o Protocol Rel > 0 (1xEV-DO)
• Press “Start Data Connection” when “Session Open” appear in “Active Cell”
• Rvs Power Ctrl > All Up bits (Maximum TxPout)

EVDO Release 0 - FTAP
• Call Setup > Shift & Preset
• Call Control:
   o Access Network Info > Cell Parameters > Sector ID > 00000000 > Subnet Mask > 0
   o Generator Info > Termination Parameters > Max Forward Packet Duration > 16 Slots
• Call Parms:
   o Cell Power > -105.5 dBm/1.23 MHz
   o Cell Band > (Select US Cellular or US PCS)
   o Channel > (Enter channel number)
   o Application Config > Enhanced Test Application Protocol > FTAP (default)
   o FTAP Rate > 307.2 kbps (2 Slot, QPSK)
   o Rvs Power Ctrl > Active bits
   o Protocol Rel > 0 (1xEV-DO)
• Press “Start Data Connection” when “Session Open” appear in “Active Cell”
• Rvs Power Ctrl > All Up bits (Maximum TxPout)

RF Power Output for EV-DO Rel 0
Cell Band
                                                                                           Conducted power (dBm)
     FTAP Rate               RTAP Rate                Channel                 f (MHz)      Average        Peak
                                                       1013                   824.70        23.55         28.17
     307.2 kbps
                             153.6 kbps                 384                   836.52        23.50         28.12
   (2 slot, QPSK)
                                                        777                   848.31        23.50         28.10

PCS Band
                                                                                           Conducted power (dBm)
     FTAP Rate               RTAP Rate                Channel                 f (MHz)      Average        Peak
                                                         25                  1851.25        23.50         28.64
     307.2 kbps
                             153.6 kbps                 600                  1880.00        23.50         28.63
   (2 slot, QPSK)
                                                       1175                  1908.75        23.50         28.04




COMPLIANCE CERTIFICATION SERVICES                                                                            Page: 17 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                          FCC ID: N7NAC402


     9.4 RF POWER OUTPUT FOR EV-DO REV A
This procedure assumes the Agilent 8960 Test Set has the following applications installed and with valid
license.
Application                 Rev, License
1xEV-DO Terminal Test       A.09.13

EVDO Release A – RETAP
•      Call Setup > Shift & Preset
•      Cell Power > -60 dBm/1.23 MHz
•      Protocol Rev > A (1xEV-DO-A)
•      Application Config > Enhanced Test Application Protocol > RETAP
•      R-Data Pkt Size > 4096
•      Protocol Subtype Config > Release A Physical Layer Subtype > Subtype 2
> PL Subtype 2 Access Channel MAC Subtype > Default (Subtype 0)
•      Access Network Info > Cell Parameters > Sector ID > 00000000 > Subnet Mask > 0
•      Generator Info > Termination Parameters > Max Forward Packet Duration >16 Slots
       > ACK R-Data After > Subpacket 0 (All ACK)
•      Rvs Power Ctrl > All Up bits (to get the maximum power)

EVDO Release A - FETAP
•      Call Setup > Shift & Preset
•      Cell Power > -60 dBm/1.23 MHz
•      Protocol Rev > A (1xEV-DO-A)
•      Application Config > Enhanced Test Application Protocol > FETAP
•      F-Traffic Format > 4 (1024, 2,128) Canonical (307.2k, QPSK)
•      Protocol Subtype Config > Release A Physical Layer Subtype > Subtype 2
> PL Subtype 2 Access Channel MAC Subtype > Default (Subtype 0)
•      Access Network Info > Cell Parameters > Sector ID > 00000000 > Subnet Mask > 0
•      Generator Info > Termination Parameters > Max Forward Packet Duration >16 Slots
       > ACK R-Data After > Subpacket 0 (All ACK)
•      Rvs Power Ctrl > All Up bits (to get the maximum power)
RF Power Output Results for EV-DO Rev A
Cell Band
                                                                                                 Conducted power (dBm)
     FETAP-Traffic Format           RETAP-Data Payload Size            Channel         f (MHz)   Average       Peak
                                                                        1013           824.70     23.70        29.19
 307.2k, QPSK/ ACK channel
                                                4096                     384           836.52     23.60        29.21
 is transmitted at all the slots
                                                                         777           848.31     23.60        28.94

PCS Band
                                                                                                 Conducted power (dBm)
     FETAP-Traffic Format           RETAP-Data Payload Size            Channel         f (MHz)   Average       Peak
                                                                          25          1851.25     23.70        29.11
 307.2k, QPSK/ ACK channel
                                                4096                     600          1880.00     23.75        29.23
 is transmitted at all the slots
                                                                         1175         1908.75     23.70        28.93




COMPLIANCE CERTIFICATION SERVICES                                                                               Page: 18 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                         FCC ID: N7NAC402

10    SAR MEASURMENT RESULTS FOR WWAN
10.1 PCS BAND
                                 Separation                                                             1g_SAR (mW/g)
  Test Configurations             Distance             Mode           Channel              f (MHz)
                                   (mm)                                                              Measured        Limit
                                                       Rel 0              25           1851.25         1.35
                                                       Rel 0             600                1880       1.46
     Express Card
 (inserted into Toshiba                                Rel 0             1175          1908.75         1.13
                                       10                                                                             1.6
     Satellite P105-                                   Rev A              25           1851.25         1.37
         S9337)
                                                       Rev A             600                1880       1.51
                                                       Rev A             1175          1908.75         1.30
                                                       Rel 0              25           1851.25         1.00
   Card Bus PC Card
 (inserted into Toshiba                                Rel 0             600                1880       1.07
                                       10                                                                             1.6
     Satellite A105-                                   Rel 0             1175          1908.75        0.789
         S4344)
                                                       Rev A             600                1880       1.14

Notes:
   1. The modes with highest output power channel were chosen for the testing.
   2. SAR for Subtype 2 Physical Layer configurations is not required for Rev. A when the maximum
       average output of each RF channels is less than that measured in Subtype 0/1 Physical Layer
       configurations. Otherwise, SAR is measured on the maximum output channel for Rev. A using
       the exposure configuration that results in the highest SAR for that RF channel in Rel. 0.
   3. SAR is not required for 1xRTT when the maximum average output of each channel is less than ¼
       dB higher than that measured in Subtype 0/1 Physical Layer configurations for Rel. 0.




COMPLIANCE CERTIFICATION SERVICES                                                                               Page: 19 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                         FCC ID: N7NAC402

10.2 CELL BAND
                                 Separation                                                             1g_SAR (mW/g)
  Test Configurations             Distance             Mode           Channel              f (MHz)
                                   (mm)                                                              Measured        Limit
                                                       Rel 0             1013              824.7      0.869
                                                       Rel 0             384               836.52     0.953
     Express Card
 (inserted into Toshiba                                Rel 0             777               848.31     0.726
                                       10                                                                             1.6
     Satellite P105-                                   Rev A             1013              824.7      0.986
         S9337)
                                                       Rev A             384               836.52      1.04
                                                       Rev A             777               848.31     0.781
                                                       Rel 0             1013              824.7      0.739
   Card Bus PC Card
 (inserted into Toshiba                                Rel 0             384               836.52     0.860
                                       10                                                                             1.6
     Satellite A105-                                   Rel 0             777               848.31     0.658
         S4344)
                                                       Rev A             384               836.52     0.926

Notes:
   1. The modes with highest output power channel were chosen for the testing.
   2. SAR for Subtype 2 Physical Layer configurations is not required for Rev. A when the maximum
       average output of each RF channels is less than that measured in Subtype 0/1 Physical Layer
       configurations. Otherwise, SAR is measured on the maximum output channel for Rev. A using
       the exposure configuration that results in the highest SAR for that RF channel in Rel. 0.
   3. SAR is not required for 1xRTT when the maximum average output of each channel is less than ¼
       dB higher than that measured in Subtype 0/1 Physical Layer configurations for Rel. 0.




COMPLIANCE CERTIFICATION SERVICES                                                                               Page: 20 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


                                                                                    Date/Time: 1/26/2009 11:37:21 AM

Test Laboratory: Compliance Certification Services


Lapheld — Express Card

DUT: Sierra Wireless; Type: AC402; Serial: GOBEBDGD

Communication System: CDMA PCS band; Frequency: 1880 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1880 MHz; 0 = 1.55 mho/m,; e, = 51.3; p = 1000 kg/im?
Phantom section: Flat Section

Room Ambient Temperature: 25.0 deg. C; Liquid Temperature: 24.0 deg. C
DASY4 Configuration
— Area Scan setting — Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
— Probe: EX3DV3 — SN3531; ConvF(8.7, 8.7, 8.7); Calibrated: 4/23/2008
— Sensor—Surface: 3mm (Mechanical Surface Detection)
— Electronics: DAE3 Sn427; Calibrated: 10/20/2008
— Phantom: Flat Phantom EL14.0; Type: QDOVAOO1BA; Serial: SN:XXXX
— Measurement SW DASY4, V4.7 Build 71; Postprocessing SW: SEMCAD, V1.8 Build 184



EV—DO Rev. A — Mid—ch (d=10 mm) 2/Area Scan (6x10x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.71 mWq

EV—DO Rev. A — Mid—ch (d=10 mm) 2/Zo0om Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=3mm
Reference Value = 33.0 V/im; Power Drift = 0.221 dB
Peak SAR (extrapolated) = 2.61 Wikg
SAR(1 g) = 1.51 mWig; SAR(10 g) = 0.838 mWig
Maximum value of SAR (measured) = 1.84 mWq


          mWig
           1.71


           1.37



           1.03


           0.686



           0.344


           0.003




                                                                                                                       27


                                                         owertine anaotens zs a
TatLatoory Conptarce Centcon Sevces
Laphold — Express Card
00 Sere iesTiAcir sera saecoco
Carmatcton ptem: COU Fremuny t3 2 Mc uy Orde 11
Hadim parantoun(rupalauts * t0 82 hte > use nhan + 539. o 100 hyn?
Protanseston n seton
Rom AntotTenpuates.20desG; LiidTersunice .21 0w0
Ohor4cortznntcn
—es Scann: n ScuntayMsm in 20 9 ant wat en SAR vae entan Oootatag
"mete Soon ‘awsot Canrtfoas 1822 125. cainmid vanarce
"SteaSatice 2ne (Mecanca sutice Btcic)
"eanece 0E cotr Catee rocontcs
"Frann ratPranam £Lt0.nee aponorten sesnn
"Hemsronert if DRGTA VC 7 l 71 Portnceiing t cenenoui nsoe

EV—DO Rev. A — Mic.h (d=10 mm}Area Scan (Bx101}: Homrcnenit d—tSon. ttem
t nevolnnd netun punnewr w tSontuain
HinimanvaueoS nemure> 10 mitlo
EV—D0 Rev. A — Mid.ch (d=10 mmZoom Scan (7x7x8}iCube 0: Hemerenart it a—Som
drins drinn
Rdenece i 222¥ pove ont «.971 cn
Pou SR (enramed—‘1 t o
SARH  a t mivgsantio
t intrated             o#cart
             nedtinpunndue     move
                           wes oSontuatn
Himimanvaue oSi nemured» 1t mitlo
       wl
       l


       nste
       sae
       sez
       nove




                                                                                  r2r


REPORT NO: 08U12312-5                                     DATE: February 11, 2009                           FCC ID: N7NAC402

11    EQUIPMENT LIST AND CALIBRATION
                                                                                                            Cal. Due date
Name of Equipment                           Manufacturer          Type/Model          Serial Number
                                                                                                      MM DD             Year
Robot - Six Axes                               Stäubli              RX90BL                 N/A                    N/A
Robot Remote Control                           Stäubli              CS7MB              3403-91535                 N/A
DASY4 Measurement Server                       SPEAG             SEUMS001BA                1041                   N/A
Probe Alignment Unit                           SPEAG                LB (V2)                 261                   N/A
SAM Phantom (SAM1)                             SPEAG             QD000P40CA                1185                   N/A
SAM Phantom (SAM2)                             SPEAG             QD000P40CA                1050                   N/A
Oval Flat Phantom (ELI 4.0)                    SPEAG             QD OVA001 B               1003                   N/A
Electronic Probe kit                              HP                85070C                  N/A                   N/A
S-Parameter Network Analyzer                   Agilent             8753ES-6            MY40001647      11    22         2010
E-Field Probe                                  SPEAG                EX3DV3                 3531         4    24         2009
Thermometer                                    ERTCO                639-1S                 1718         5    28         2009
Data Acquisition Electronics                   SPEAG               DAE3 V1                  427        10    20         2009
System Validation Dipole                       SPEAG                D835V2                4d002        6     22         2009
System Validation Dipole                       SPEAG               D1900V2                5d043        1     29         2010
System Validation Dipole                       SPEAG               D2450V2                 748         4     14         2010
Signal Generator                                 R&S                SMP 04               DE34210       2     16         2009
Power Meter                                  Giga-tronics            8651A               8651404       1     11         2010
Power Sensor                                 Giga-tronics           80701A               1834588       1     11         2010
Amplifier                                    Mini-Circuits         ZHL-42W              D072701-5                 N/A
Radio Communication Tester                       R &S               CMU 200            838114/032       5    16         2009
Simulating Liquid                                 CCS                 H835                 N/A        Within 24 hrs of first test
Simulating Liquid                                 CCS                 M835                 N/A        Within 24 hrs of first test
Simulating Liquid                                 CCS                 H1900                N/A        Within 24 hrs of first test
Simulating Liquid                                 CCS                 M1900                N/A        Within 24 hrs of first test
Simulating Liquid                                 CCS                 H2450                N/A        Within 24 hrs of first test
Simulating Liquid                                 CCS                 M2450                N/A        Within 24 hrs of first test




COMPLIANCE CERTIFICATION SERVICES                                                                                 Page: 23 of 27
This report shall not be reproduced except in full, without the written approval of CCS.


REPORT NO: 08U12312-5                                     DATE: February 11, 2009          FCC ID: N7NAC402

12    ATTACHMENTS

     No.                                               Contents                            No. of Pages
       1         System Performance Check Plots                                                 4
     2-1         SAR Test Plots for PCS Band                                                    11
     2-2         SAR Test Plots for Cell Band                                                   11
       3         Certificate of E-Field Probe - EX3DV3SN3531                                    10
       4         Certificate of System Validation Dipole - D835V2 SN:4d002                      9
       5         Certificate of System Validation Dipole - D1900V2 SN:5d043                     9




COMPLIANCE CERTIFICATION SERVICES                                                              Page: 24 of 27
This report shall not be reproduced except in full, without the written approval of CCS.



Document Created: 2009-02-11 16:47:59
Document Modified: 2009-02-11 16:47:59

© 2024 FCC.report