SAR Plots - repeatability measurements

FCC ID: N7NAC340U

RF Exposure Info

Download: PDF
FCCID_1866291

Test Laboratory: UL CCS SAR Lab E Date: 10/18/2012

GSM850

Frequency: 836.6 MHz; Duty Cycle: 1:4; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                  3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.965 mho/m; εr = 54.201; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1343; Calibrated: 8/20/2012
- Probe: EX3DV4 - SN3871; ConvF(9.68, 9.68, 9.68); Calibrated: 8/20/2012;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 A; Type: QDOVA002AA; Serial: 1180

Horizontal Up/GPRS 2 slots/Ch 190/Area Scan (10x13x1): Measurement grid: dx=10mm, dy=10mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 1.31 W/kg

Horizontal Up/GPRS 2 slots/Ch 190/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 37.777 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 1.640 mW/g
SAR(1 g) = 1.11 mW/g; SAR(10 g) = 0.717 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 1.35 W/kg




                     0 dB = 1.35 W/kg = 2.61 dB W/kg




                                                                                                           Plot No. 1


Test Laboratory: UL CCS SAR Lab E Date: 10/19/2012

GSM1900

Frequency: 1909.8 MHz; Duty Cycle: 1:4; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                  3
Medium parameters used: f = 1910 MHz; σ = 1.557 mho/m; εr = 52.453; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1343; Calibrated: 8/20/2012
- Probe: EX3DV4 - SN3871; ConvF(7.83, 7.83, 7.83); Calibrated: 8/20/2012;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1180

Horizontal Up_Repeated Test/GPRS 2 slots/Ch 810/Area Scan (10x13x1): Measurement grid:
dx=10mm, dy=10mm
Maximum value of SAR (measured) = 1.47 W/kg

Horizontal Up_Repeated Test/GPRS 2 slots/Ch 810/Zoom Scan (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 32.013 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 2.008 mW/g
SAR(1 g) = 1.25 mW/g; SAR(10 g) = 0.736 mW/g
Maximum value of SAR (measured) = 1.57 W/kg




                     0 dB = 1.57 W/kg = 3.92 dB W/kg




                                                                                                           Plot No. 2


Test Laboratory: UL CCS SAR Lab E Date: 10/19/2012

LTE Band 4

Frequency: 1732.5 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                                   3
Medium parameters used (interpolated): f = 1732.5 MHz; σ = 1.492 mho/m; εr = 53.157; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1343; Calibrated: 8/20/2012
- Probe: EX3DV4 - SN3871; ConvF(8.1, 8.1, 8.1); Calibrated: 8/20/2012;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm
(Mechanical Surface Detection)
- Phantom: ELI v5.0 B; Type: QDOVA002AA; Serial: 1180

Horizontal Up/QPSK_RB# 1, 49/Ch 20175/Area Scan (10x13x1): Measurement grid: dx=10mm,
dy=10mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 1.11 W/kg

Horizontal Up/QPSK_RB# 1, 49/Ch 20175/Zoom Scan (7x7x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 27.515 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 1.471 mW/g
SAR(1 g) = 0.877 mW/g; SAR(10 g) = 0.517 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.957 W/kg




                     0 dB = 1.11 W/kg = 0.91 dB W/kg




                                                                                                           Plot No. 3



Document Created: 2012-11-27 18:57:27
Document Modified: 2012-11-27 18:57:27

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC