10U13412-6A SAR attachment 1-1

FCC ID: N7N-MHS802

RF Exposure Info

Download: PDF
FCCID_1412544

                                                                                       Date/Time: 9/27/2010 4:13:11 PM

Test Laboratory: Compliance Certification Services

Cell 850_Top mode
DUT: Sierra Wireless; Type: NA; Serial: NA

Communication System: CDMA Cell Band; Frequency: 836.52 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.992 mho/m; εr = 56; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: SAM 2 (Twin); Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

1xRTT SO32_M-ch/Area Scan (9x9x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.893 mW/g

1xRTT SO32_M-ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 30.4 V/m; Power Drift = -0.138 dB
Peak SAR (extrapolated) = 1.19 W/kg
SAR(1 g) = 0.791 mW/g; SAR(10 g) = 0.526 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.918 mW/g


                                                                              Date/Time: 9/27/2010 7:15:34 PM

Test Laboratory: Compliance Certification Services

Cell 850_Top mode
DUT: Sierra Wireless; Type: NA; Serial: NA

Communication System: CDMA Cell Band; Frequency: 836.52 MHz;Duty Cycle: 1:1



1xRTT SO32_M-ch/Z Scan (1x1x29): Measurement grid: dx=20mm, dy=20mm, dz=3.5mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.879 mW/g


                                                                                       Date/Time: 9/27/2010 6:41:34 PM

Test Laboratory: Compliance Certification Services

Cell 850_Top mode
DUT: Sierra Wireless; Type: NA; Serial: NA

Communication System: CDMA Cell Band; Frequency: 836.52 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.992 mho/m; εr = 56; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: SAM 2 (Twin); Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

1xRTT SO32_M-ch/Area Scan (9x9x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.836 mW/g

1xRTT SO32_M-ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 29.1 V/m; Power Drift = -0.103 dB
Peak SAR (extrapolated) = 1.11 W/kg
SAR(1 g) = 0.765 mW/g; SAR(10 g) = 0.513 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.884 mW/g


                                                                                       Date/Time: 9/27/2010 4:55:56 PM

Test Laboratory: Compliance Certification Services

Cell 850_Bottom mode
DUT: Sierra Wireless; Type: NA; Serial: NA

Communication System: CDMA Cell Band; Frequency: 836.52 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.992 mho/m; εr = 56; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: SAM 2 (Twin); Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

1xRTT SO32_M-ch/Area Scan (9x9x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.813 mW/g

1xRTT SO32_M-ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 28.7 V/m; Power Drift = 0.159 dB
Peak SAR (extrapolated) = 1.14 W/kg
SAR(1 g) = 0.776 mW/g; SAR(10 g) = 0.517 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.894 mW/g


                                                                                       Date/Time: 9/27/2010 6:06:54 PM

Test Laboratory: Compliance Certification Services

Cell 850_Edge mode
DUT: Sierra Wireless; Type: NA; Serial: NA

Communication System: CDMA Cell Band; Frequency: 836.52 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.52 MHz; σ = 0.992 mho/m; εr = 56; ρ = 1000 kg/m3
Phantom section: Flat Section
Room Ambient Temperature: 24.0 deg. C; Liquid Temperature: 23.0 deg. C
DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Probe: EX3DV3 - SN3531; ConvF(10.18, 10.18, 10.18); Calibrated: 2/23/2010
- Sensor-Surface: 3mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 7/21/2010
- Phantom: SAM 2 (Twin); Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.7 Build 80; Postprocessing SW: SEMCAD, V1.8 Build 186

1xRTT SO32_M-ch/Area Scan (9x9x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.210 mW/g

1xRTT SO32_M-ch/Zoom Scan (7x7x9)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=3mm
Reference Value = 14.5 V/m; Power Drift = -0.108 dB
Peak SAR (extrapolated) = 0.311 W/kg
SAR(1 g) = 0.182 mW/g; SAR(10 g) = 0.112 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.221 mW/g



Document Created: 2010-10-15 17:20:13
Document Modified: 2010-10-15 17:20:13