DFS testreport 2

FCC ID: N6C-SX10WAG

Test Report

Download: PDF
FCCID_853243

                                                                   Test report No.   : 27KE0242-HO-A
                                                                   Page              : 22 of 23
                                                                   Issued date       : September 27, 2007
                                                                   FCC ID            : N6C-SX10WAG


APPENDIX 2: Data of DFS test

                                     Parameter Data for Radar Type 5

  Trial         Number of Pulse Width Chirp Width Pulse 1-to-2    Pulse 2-to-3   Starting Location
          Burst
 Number          Pulses      (usec)     (MHz)     Spacing (usec) Spacing (usec) Within Interval (usec)
        1     1         2           71        11           1000                               252421
        1     2         3           82        12           1020            1653               743407
        1     3         3           96        12           1732            1717                 73328
        1     4         3           56        20           1000            1153               825412
        1     5         2           54          7          1976                               896923
        1     6         2           54        20           1594                               370119
        1     7         2           75        14           1503                               973316
        1     8         3           89          5          1683            1296               215826
        1     9         1           68        12                                              967702
        1   10          1           83        13                                              293246
        1   11          2           69        12           1135                               968264
        1   12          2           62          6          1206                                 72149




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124


                                                                              Test report No.   : 27KE0242-HO-A
                                                                              Page              : 23 of 23
                                                                              Issued date       : September 27, 2007
                                                                              FCC ID            : N6C-SX10WAG


APPENDIX 3:Test instruments

EMI Test Equipment
 Control No.     Instrument            Manufacturer         Model No         Test Item      Calibration Date *
                                                                                             Interval(month)
  MOS-14      Thermo-Hygrometer     Custom             CTH-180              DFS           2006/01/19 * 24
  MSG-05      Signal Generator      Agilent            E4438C               DFS           2007/06/20 * 12
  MSA-03      Spectrum Analyzer     Agilent            E4448A               DFS           2006/09/13 * 12
  MPSC-02     Power                 Mini-Circuit       ZFSC-2-10G           DFS           2006/09/25 * 12
              Splitters/Combiners
  MPSC-04     Power                 Mini-Circuit       ZFSC-2-10G           DFS           2007/01/17 * 12
              Splitters/Combiners
   MPD-01     PowerDivider DC to    Agilent            11636B               DFS           2007/03/16 * 12
              26.5GHz
   MCC-65     Microwave Cable 1G-   Schner             SUCOFLEX102          DFS           2007/04/03 * 12
              40GHz
   MCC-66     Microwave Cable 1G-   Schner             SUCOFLEX102          DFS           2007/04/03 * 12
              40GHz
   MCC-35     Microwave Cable       Hirose Electric U.FL-2LP-066-A-         DFS           2006/11/13 * 12
                                                    (200)
   MCC-37     Microwave Cable      Hirose Electric  U.FL-2LP-066-A-         DFS           2006/11/13 * 12
                                                    (200)
   MAT-21     Attenuator(20dB)(abo HIROSE ELECTRIC AT-120                   DFS           2007/01/11 * 12
              ve1GHz)              CO.,LTD.
   MAT-22     Attenuator(10dB)     Orient Microwave BX10-0476-00            DFS           2007/03/07 * 12
              DC-18GHz
   MAT-24     Attenuator(10dB)(abo Agilent          8493C                   DFS           2007/06/28 * 12
              ve1GHz)
   MAT-39     Attenuator(20dB)1-   Weinschel        54A-20                  DFS           2006/12/12 * 12
              40GHz
   MAT-40     Attenuator(20dB)1-   Weinschel        54A-20                  DFS           2006/12/12 * 12
              40GHz
  MSTW-30     Signal Studio        Agilent          N7620A-101              DFS           -
              Software for DFS
  MSTW-31     Radar Generating     Agilent          -                       DFS           -
              Software for DFS
   MTA-24     Terminator           Weinschel        M1459A                  DFS           2006/12/13 * 12
   MTA-25     Terminator           Weinschel        M1459A                  DFS           2006/12/13 * 12
   MOS-04     Digital Humidity     N.T              NT-1800                 DFS           2006/11/27 * 12
              Indicator


The expiration date of the calibration is the end of the expired month.

All equipment is calibrated with traceable calibrations. Each calibration is traceable to the national or
international standards.

DFS: Dynamic Frequency Selection




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124



Document Created: 2007-10-02 18:08:02
Document Modified: 2007-10-02 18:08:02