RF Exposure

FCC ID: N6C-SDMGN

RF Exposure Info

Download: PDF
FCCID_2200923

                                      RF Exposure / MPE Calculation
                                            No. : 10156278H
                  Applicant            :     silex technology, Inc.
                  Type of Equipment    :     SDIO Wireless Module
                  Model No.            :     SX-SDMGN
                  FCC ID               :     N6C-SDMGN


silex technology, Inc. declares that Model : SX-SDMGN                                             ⇒
complies with FCC radiation exposure requirement specified in the FCC Rule 2.1091 (for mobile).


RF Exposure Calculations:                                                                         ←

The following information provides the minimum separation distance for the highest gain
antenna provided with the “SX-SDMGN“ as calculated
from (B) Limits for General Population / Uncontrolled Exposure of
TABLE 1- LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) of §1.1310 Radiofrequency
radiation exposure limits.
This calculation is based on the highest EIRP possible from the system,
considering maximum power and antenna gain, and considering a 1.0mW/cm^2 uncontrolled
exposure limit. The Friis formula used was:



          S = (P * G) / (4* π * r2)
Where
             P=    194.73 mW (Maximum average output power)
             G=      3.16 Numerical Antenna gain; equal to  5.00 dBi
             r=      20.0 cm




For: SX-SDMGN                                                S=    0.12251 mW/cm2


Reference data from Original test report: 32IE0153-HO-01

Where
             P=    194.73 mW (Maximum peak output power)
             G=      1.62 Numerical Antenna gain; equal to            2.10 dBi
             r=      20.0 cm



For: SX-SDMGN                                                S=    0.06283 mW/cm2