RF EX

FCC ID: N6C-SDMAN

RF Exposure Info

Download: PDF
FCCID_2934736

                                  RF Exposure / MPE Calculation
                          No. : 32IE0154-HO-01 / 10517042H / 11166423H
                     Applicant         :          silex technology, Inc.
                     Type of Equipment :          SDIO Wireless Module *1)
                                                  (11n-20(5180 - 5320MHz, 5745 - 5825MHz),
                                                  11n-40(5190 - 5310MHz, 5755 - 5795MHz),
                                                  11a(5180 - 5320MHz, 5745 - 5825MHz))
                     Model No.             :      SX-SDMAN
                     FCC ID                :      N6C-SDMAN
                     IC Number             :      4908B-SDMAN

  silex technology, Inc. declares that Model : SX-SDMAN
  complies with FCC radiation exposure requirement specified in the FCC Rules 2.1091 (for mobile).


  RF Exposure Calculations:

  The following information provides the minimum separation distance for the highest gain
  antenna provided with the “SX-SDMAN“ as calculated
  from (B) Limits for General Population / Uncontrolled Exposure of
  TABLE 1- LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) of §1.1310 Radiofrequency
  radiation exposure limits.
  This calculation is based on the highest EIRP possible from the system,
  considering maximum power and antenna gain, and considering a 1.0mW/cm^2 uncontrolled
  exposure limit. The Friis formula used was:


             S = (P * G) / (4* π * r2)
  Where
                P=     24.66 mW (Maximum conducted output power)
             Frame power was used for the above value in consideration of 6-minutes time-averaging
             Burst power was used for the above value in consideration of worst condition.
                G=      3.02 Numerical Antenna gain; equal            4.80 dBi
                r=      20.0 cm

                                                                                          2
  For: SX-SDMAN                                                S=     0.01482 mW/cm

  Even taking into account the tolerance, this device can be satisfied with the limits.

  *1) The test of frequency band 5180-5320MHz and 5190-5310MHz were referred from 32IE0154-HO-01.
      The test of frequency band 5745-5825MHz and 5775-5795MHz were referred to by 10517042H.




UL Japan, Inc.
Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8999
Facsimile       : +81 596 24 8124



Document Created: 2016-03-18 13:05:05
Document Modified: 2016-03-18 13:05:05

© 2024 FCC.report