RF Exposure (FCC15E)

FCC ID: N6C-SDMAN

RF Exposure Info

Download: PDF
FCCID_2225417

                                     RF Exposure / MPE Calculation
                                         No. : 10195552-001H
                     Applicant         :        silex technology, Inc.
                     Type of Equipment :        SDIO Wireless Module (11n-20(5180 - 5320MHz),
                                                11n-40(5190 - 5310MHz), 11a(5180 - 5320MHz))
                     Model No.           :      SX-SDMAN
                     FCC ID              :      N6C-SDMAN
                     IC Number           :      4908B-SDMAN

   silex technology, Inc. declares that Model : SX-SDMAN
   complies with FCC radiation exposure requirement specified in the FCC Rules 2.1091 (for mobile).


   RF Exposure Calculations:

   The following information provides the minimum separation distance for the highest gain
   antenna provided with the “SX-SDMAN“ as calculated
   from (B) Limits for General Population / Uncontrolled Exposure of
   TABLE 1- LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) of §1.1310 Radiofrequency
   radiation exposure limits.
   This calculation is based on the highest EIRP possible from the system,
   considering maximum power and antenna gain, and considering a 1.0mW/cm^2 uncontrolled
   exposure limit. The Friis formula used was:

             S = (P * G) / (4* π * r2)
   Where
                P=      24.66 mW (Maximum peak output power)
                G=       3.02 Numerical Antenna gain; equal  4.80 dBi
                r=       20.0 cm

                                                                                   2
   For: SX-SDMAN                                            S=    0.01482 mW/cm


   Reference data from Original test report: 32IE0154-HO-01

   Where
                P=      24.66 mW (Maximum peak output power)
                G=       1.78 Numerical Antenna gain; equal  2.50 dBi
                r=       20.0 cm

   For: SX-SDMAN                                            S=   0.00872 mW/cm2




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124



Document Created: 2014-03-24 13:02:37
Document Modified: 2014-03-24 13:02:37

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC