RF Exposure (15.247_LE)

FCC ID: N6C-SDMAN

RF Exposure Info

Download: PDF
FCCID_1769858

                                       RF Exposure / MPE Calculation
                                           No. : 32IE0154-HO-01
                   Applicant            :     silex technology, Inc.
                   Type of Equipment    :     SDIO Wireless Module (Low Energy)
                   Model No.            :     SX-SDMAN
                   FCC ID               :     N6C-SDMAN
                   IC Number            :     4908B-SDMAN

 silex technology, Inc. declares that Model : SX-SDMAN
 complies with FCC radiation exposure requirement specified in the FCC Rules 2.1091 (for mobile).


 RF Exposure Calculations:

 The following information provides the minimum separation distance for the highest gain
 antenna provided with the “SX-SDMAN“ as calculated
 from FCC OET Bulletin 65 Appendix A, Table (B) Limits for General Population / Uncontrolled
 Exposure. This calculation is based on the highest EIRP possible from the system,
 considering maximum power and antenna gain, and considering a 1.0mW/cm^2 uncontrolled
 exposure limit. The Friis formula used was:



           S = (P * G) / (4* π * r2)
 Where
              P=       8.63 mW (Maximum peak output power)
              G=       1.58 Numerical Antenna gain; equal to           2.00 dBi
              r=       20.0 cm




 For: SX-SDMAN                                                S=    0.00272 mW/cm2




UL Japan, Inc.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124



Document Created: 2012-08-06 16:00:38
Document Modified: 2012-08-06 16:00:38