Test report 15B Annex 1 Measurement diagrams

FCC ID: N5A6847

Test Report

Download: PDF
FCCID_4085466

                                 Annex 1: Measurement diagrams to
                                       TEST REPORT
                                      No.: 18-1-0102601T03a



                                                           According to:
                                                        FCC Regulations
                                                     Part 15.107, Part 15.109

                                                        ISED-Regulations
                                                         RSS-Gen, Issue 4
                                                        ICES-003, Issue 6



                                                               for

                                               Leica Camera AG

                                                   Digital Camera
                                                   Type No. 6847

                                                    FCC-ID: N5A6847
                                                   ISED: 11245A-6847




                                             Laboratory Accreditation and Listings



                                                                                    Voluntary Controls for Electromagnetic
                                                       Industry Canada
                                                                                                 Emissions
                                                      Reg. No.: 3462D-1
                                                      Reg. No.: 3462D-2                          Reg. No.:
            Accredited EMC-Test Laboratory            Reg. No.: 3462D-3                      R-4452, C-20009,
                                                                                             T-20006, G-20013




                                                                                             MRA US-EU 0003

                                      accredited according to DIN EN ISO/IEC 17025

                                                      CETECOM GmbH
                               Laboratory Radio Communications & Electromagnetic Compatibility
                                           Im Teelbruch 116 • 45219 Essen • Germany
                                  Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                    E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                     Page 1 of 4
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without
the written approval of the testing laboratory                                  © Copyright: All rights reserved by CETECOM


Annex 1 to Test Report 18-1-0102601T03a, Page 2 of 4



Table of contents
1. MEASUREMENT DIAGRAMS......................................................................................................................... 3
  1.1. Conducted emissions on AC-mains (120V/60Hz) ........................................................................................... 3
  1.2. Radiated emissions in the frequency range 30 to 1000MHz............................................................................ 4




CETECOM_TR18_1_0102601T03a_Annex1


Annex 1 to Test Report 18-1-0102601T03a, Page 3 of 4




1. Measurement diagrams
1.1. Conducted emissions on AC-mains (120V/60Hz)
1.1.1. Part 15B: Video-Mode
                                                       Diagram No. 1.01
Common Information
 Test Description:                                    Conducted Voltage Measurement Class B
 Test Site & Location:                                Conducted Emission, CETECOM GmbH Essen
 Test Software:                                       R&S EMC32 v9.15
 Test Specification:                                  FCC 15.107 /RSS-Gen, Issue 4
 Operating Mode:                                      Video mode
 Measured on line:                                    N/L1
 Diagram details:                                     Shows the peak values as a sum of measured ports in maxhold mode
 Environmental Conditions:                            Humidity: 42%rH; Temperature: 22°C
 Operator:                                            Mar

EUT Information
 Manufacturer:                                        Leica Camera AG
 Model:                                               Digital Camera
 Type:                                                6847
 -----------------------------------------            ---------------------------------------------
 SW:                                                  0.18.10.2
 HW:                                                  Prototype
 Ser-No:                                              P-016
                                                      1801-0101
 Power Supply:                                        120VAC/60Hz
            Level in dBµV




Final_Result
  Frequency                 QuasiP      CAvera      Limit
    (MHz)                     eak         ge       (dBµV)
                            (dBµV)      (dBµV)
       0.150000                   ---     30.96     56.00
       0.150000               46.40          ---    66.00
       0.163750               47.04          ---    65.27
       0.163750                   ---     33.86     55.27
       0.174375               45.28          ---    64.75
       0.174375                   ---     31.24     54.75
       0.242344               46.09          ---    62.02
       0.242344                   ---     34.05     52.02
       0.586094               40.39          ---    56.00
       0.586094                   ---     34.74     46.00


CETECOM_TR18_1_0102601T03a_Annex1


Annex 1 to Test Report 18-1-0102601T03a, Page 4 of 4


1.2. Radiated emissions in the frequency range 30 to 1000MHz
1.2.1. Part 15B: Video Mode

                                                       Diagram No. 3.01
                                                      24.01.2018      Page 1 of 1
 Test description:                                    Electric Field Strength Measurement
 Test site and distance:                              Ref.-Nr. 441 Semi Anechoic Room (SAR) with 3 m measurement distance
 Version of Testsoftware:                             EMC32 V9.25.0
 Distance correction:                                 not used
 Used filter:                                         not used
 Test specification.:                                 FCC 15.109 Class B/ RSS-Gen., Issue 4
 Operator:                                            MBe
 Operating conditions:                                Video mode
 Power during tests:                                  120V/60Hz

EUT Information
 Manufacturer:                                        Leica Camera AG
 Model:                                               Digital Camera
 Type:                                                6847
 -----------------------------------------            ---------------------------------------------
 SW:                                                  0.18.10.2
 HW:                                                  Prototype
 Ser-No:                                              P-016
                                                      1801-0101
 Power Supply:                                        120VAC/60Hz
            Level in dBµV/m




       Final_Result
         Frequen              QuasiPeak       Limit   Meas.        Bandwidt          Heigh        Pol   Azimut   Corr
            cy                (dBµV/m)       (dBµV/   Time             h               t                   h       .
          (MHz)                                m)     (ms)           (kHz)           (cm)                (deg)   (dB)
          63.66000                32.07       40.00   1000.0           120.000        133.0       V      286.0    7.7
          65.53000                33.39       40.00   1000.0           120.000        218.0       V      304.0    7.1
          69.18000                33.53       40.00   1000.0           120.000        128.0       V      339.0    6.6
          71.64000                32.63       40.00   1000.0           120.000        136.0       V      295.0    6.6
          88.51000                36.41       43.50   1000.0           120.000        105.0       V      116.0    8.1
          297.0100                37.36       46.00   1000.0           120.000        113.0       H      136.0   15.0



CETECOM_TR18_1_0102601T03a_Annex1



Document Created: 2018-08-10 08:21:20