Test report 15B - report original

FCC ID: N5A6847

Test Report

Download: PDF
FCCID_4085465

                                              TEST REPORT
                                              No.: 17-1-0021101T14



                                                            According to:
                                                         FCC Regulations
                                                      Part 15.107, Part 15.109

                                                           IC-Regulations
                                                          RSS-Gen, Issue 4




                                                                 for

                                                  Leica Camera AG

                                                     Digital Camera
                                                     Type No. 6847

                                                     FCC-ID: N5A6847


                                              Laboratory Accreditation and Listings



                                                                                       Voluntary Controls for Electromagnetic
                                                          Industry Canada
                                                                                                    Emissions
                                                         Reg. No.: 3462D-1
                                                         Reg. No.: 3462D-2                          Reg. No.:
             Accredited EMC-Test Laboratory              Reg. No.: 3462D-3                      R-4552, C-20009,
                                                                                                T-20006, G-20013




                                                                                                MRA US-EU 0003

                                       accredited according to DIN EN ISO/IEC 17025

                                                        CETECOM GmbH
                                Laboratory Radio Communications & Electromagnetic Compatibility
                                            Im Teelbruch 116 • 45219 Essen • Germany
                                   Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                     E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                       Page 1 of 19
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the
written approval of the testing laboratory                                         © Copyright: All rights reserved by CETECOM


Test Report 17-1-0021101T14, Page 2 of 19


Table of contents
1. Summary of test results                                                                   3
  1.1. TEST OVERVIEW ACCORDING FCC PART 15B AND CANADIAN RSS- OR ICES STANDARDS 3

2. Administrative Data                                                                       4
  2.1. Identification of the testing laboratory                                              4
  2.2. Test location                                                                         4
  2.3. Organizational items                                                                  4
  2.4. Applicant’s details                                                                   4
  2.5. Manufacturer’s details                                                                4

3. Equipment under test (EUT)                                                                5
  3.1. EUT: Type, S/N etc. and short descriptions used in this test report                   5
  3.2. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions                       5
  3.3. EUT set-ups                                                                           6
  3.4. EUT operating modes                                                                   6
  3.5. Additional declaration and description of EUT                                         7
  3.6. Configuration of cables used for testing                                              7

4. Description of test system set-up’s                                                       8
  4.1. Test system set-up for AC power-line conducted emission measurements                  8
  4.2. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz            9
  4.3. Test system set-up for radiated electric field measurement above 1 GHz               10

5. Measurements                                                                             11
  5.1. General Limit - Conducted emissions on AC-Power lines                                11
  5.2. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz                    12
  5.3. General Limit - Radiated emissions, above 1 GHz                                      13
  5.4. Measurement uncertainties                                                            14

6. Abbreviations used in this report                                                        15

7. Accreditation details of CETECOM’s laboratories and test sites                           15

8. Instruments and Ancillary                                                                16
  8.1. Used equipment “CTC”                                                                 16

9. Versions of test reports (change history)                                                19


Table of annex                                                                      Total pages
SEPARATE ANNEX 1: DIAGRAMS OF TESTING                                                       13
SEPARATE ANNEX 2: EXTERNAL EUT PHOTOGRAPHS                                                   7
SEPARATE ANNEX 3: SET-UP PHOTOGRAPHS                                                         5

The listed attachments are an integral part of this report.




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 3 of 19



1. Summary of test results
The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does not
assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or
samples of the type of the item presented to tests.


The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH
does not assume responsibility for any conclusions and generalizations taken in conjunction with other
specimens or samples of the type of the item presented to tests. Also we refer on special conditions which
the applicant should fulfill according §2.927 to §2.948, special focus regarding modification of the
equipment and availability of sample equipment for market surveilance tests.

The Equipment Under Test (in this report, hereinafter referred as EUT) is a digital device with support of
radiofrequency technologies. For this test report typical operating mode were tested according intended use
of the equipment excluding wireless operating modes.

Following tests have been performed to show compliance with applicable FCC Part 15, Subpart B (Unintentional
Radiators) of the CFR 47 Rules, Edition 4th November 2014 and Canadian RSS-Gen, Issue 4 standard.


1.1. TEST OVERVIEW ACCORDING FCC PART 15B AND CANADIAN RSS- OR
ICES STANDARDS
    No. of                                                                References, Standards & Limits                                  EUT
                             Test                                                                                           EUT
   Diagram                                               Port                                                                              op-         Result
                             Cases                                FCC                IC              Limits                set-up
    group                                                                                                                                 mode
                   AC
                                                                                                  Class A
                   Power Lines                                  §15.107      -
                                                                                                  Class B
                                                 AC
         1                                                                                                                    1            1+2        passed
                   Conducted                     Power lines
                   emissions                                                                     Chapter 8.8
                                                                   --        RSS-Gen., Issue 4
                   0,15 – 30 MHz                                                                 Table 3
                                                 Cabinet +                                        Class A
                   Radiated                                     §15.109      --
                                                 Inter-                                           Class B
         3         emissions                                                                                              1+2+3            1+2        passed
                                                 connecting                                      Chapter 8.9
                   30 MHz-1 GHz                                    --        RSS-Gen., Issue 4
                                                 cables                                          Table 4

                                                 Cabinet +                                        Class A
                   Radiated                                     §15.109      -
                                                 Inter-                                           Class B
         4         emissions                                                                                                3+4            1+2        passed
                                                 connecting
                   above 1 GHz                                                                   Chapter 8.9
                                                 cables            --        RSS-Gen., Issue 4
                                                                                                 Table 4
Remark:




......................................................                                                     ....................................................
Dipl.-Ing. Rachid Acharkaoui                                                                                                                 W. Markus
Responsible for test section                                                                                         Responsible for test report




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 4 of 19


2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Dipl.-Ing. Rachid Acharkaoui
Deputy:                                                               Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report and
project leader:                                                       W. Markus
Receipt of EUT:                                                       2018-01-23
Date(s) of test:                                                      2018-01-23, 2018-01-25
Date of report:                                                       2018-01-31
       -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             13.02 , Wolfgang [CETECOM]
2.4. Applicant’s details

Applicant’s name:                                                     Leica Camera AG
Address:                                                              Am Leitz-Park 5
                                                                      35578 Wetzlar

                                                                      Germany
Contact person:                                                       Mr. Peter Schober

2.5. Manufacturer’s details

Manufacturer’s name:                                                  please see Applicant's details

Address:                                                              please see Applicant's details




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 5 of 19


3. Equipment under test (EUT)
3.1. EUT: Type, S/N etc. and short descriptions used in this test report
 Short
                                                                      S/N              HW                 SW
 descrip-                EUT                   Type
                                                                 serial number    hardware status    software status
 tion*)
                                                                                    1745-0001-
 EUT A          Digital Camera                 6847                  P-016            0000 /            0.17.50.9
                                                                                    1801-0101
*) EUT short description is used to simplify the identification of the EUT in this test report.



3.2. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions
    AE
                                                                     S/N                HW                SW
   short           Auxiliary                 Type*1)
                                                                    serial            hardware       software status
 descrip-        Equipment*1)
                                                                  number*1)           status*1)
  tion *)
   AE 1           AC-Adapter                     --                    --                 --                --

   AE 2        Auto Focus Lens                   --                    --                 --                --

   AE 3          Audio Adapter                   --                    --                 --                --

                Remote release
   AE 4                                          --                    --                 --                --
                   cable

               SanDisk Extreme
   AE 5                                          --                    --                 --                --
                  CF-Card

             SanDisk Extreme Pro
   AE 6                                          --                    --                 --                --
                  SD-Card

   AE 7            USB cable                     --                    --                 --                --

   AE 8           HDMI cable                     --                    --                 --                --

                 Multifunction
   AE 9                                          --                    --                 --                --
                  Handgrip

  AE 10          Li-ion Battery                  --                    --                 --                --

  AE 11            Leica flash                   --                    --                 --                --
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.
*1) For futher informations please see annex 2: External EUT Photographs




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 6 of 19

3.3. EUT set-ups

 EUT set-up
                         Combination of EUT and AE                                   Remarks
   no.*)

                  EUT A + AE 1 + AE 2 + AE 3 + AE 4 +
    set. 1       AE 5 + AE 6 + AE 7 + AE 8 + AE 9 + AE              For Video Stream mode with AC Adapter
                               10 + AE 11
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.


3.4. EUT operating modes

    EUT
                   Description of
  operating                                                      Additional information
                  operating modes
 mode no.*)
                                           Recording a video during the test with special Test-Software
     op. 1         Video Stream
                                                                 “H64Toolbox”
*) EUT operating mode no. is used to simplify the test report.




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 7 of 19

3.5. Additional declaration and description of EUT
(Applicant's declaration,  = not selected,  = selected)
 EUT A                                                       table-top         typical use           typical operating
                                                                                                      cycle of EUT.
                                                     floor-standing  portable use                    < 0,5 sec.
                                                     wall-mounted  fixed use                         :
                                                     not defined         vehicular use
 Place of use                                        Residential, commercial and light industry
                                                     Industrial environment
                                                     vehicular use
 Highest frequency generated or used in the          below 1.705 MHz             -> up to 30 MHz
 device or on which the device operates or tunes  1.705 MHz – 108 MHz -> up to 1 GHz
                                                     108 MHz -500 MHz            -> up to 2 GHz
                                                     500MHz 1000 MHz             -> up to 5 GHz
                                                     1600 MHz (Main PLL) -> 40 GHz
 Power line:                                        EUT-grounding:
                                                                                     (in case of deviation during tests the
  AC  L1,  L2,               L3,      N         none
                                                                                        single details are described on
 60Hz        12V,  24V,  120V,  400V  with power supply                                       chapter 4)
  DC                                               additional:
 Other Ports                                          possible total cable length       shielding          connected
                                                                                                           during test
 (description of interconnecting cables)
                               Connector
                                                     > 1m  > 2m  > 3m  screened                         yes
 1.DC-Line
                                                    :                                unscreened  no
                                                     > 1m  > 2m  > 5m  screened                         yes
 2.USB-Line
                                                    :                                unscreened  no
                                                     > 1m  > 2m  > 3m  screened                         yes
 3.HDMI-Line
                                                    :                                unscreened  no
 Does EUT contain devices susceptible to magnetic fields, e.g. Hall elements, electrodynamics               yes
 microphones, etc.?                                                                                         no
                                                                                                            yes
 Is mounting position / usual operating position defined?
                                                                                                            no


3.6. Configuration of cables used for testing
   Cable
                                                                           S/N                   HW           Cable length
  number               Item*1)                      Type*1)
                                                                    serial number*1)          hardware
                                                                                              status*1)
 Cable 1            AC-Adapter                         --                  --                    --              1.88m

 Cable 2            USB cable                          --                  --                    --               5m

 Cable 3           HDMI cable                          --                  --                    --              1,20m

                  Remote release
 Cable 4                                               --                  --                    --               1m
                     cable
*1) For futher informations please see annex 2: External EUT Photographs




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 8 of 19


4. Description of test system set-up’s
4.1. Test system set-up for AC power-line conducted emission measurements


 Specification:             ANSI C63.4-2014 chapter 7, ANSI C63.10-2014 chapter 6.2

 General Description:       The radio frequency voltage conducted back into the AC power line in the frequency
                            range 150 kHz to 30 MHz has to be investigated. Compliance should be tested by
                            measuring the radio frequency voltage between each power line and ground at the
                            power terminals in the stated frequency range.
                            A 50 Ohm / 50 µH line impedance stabilization network (LISN) is used coupling the
                            interface to the measurement equipment. The EUT power input leads are connected
                            through the LISN to the AC-power source. The LISN enclosure is electrically
                            connected to the ground plane. The measuring instrument is connected to the coaxial
                            output of the LISN.
                            Tabletop devices were set-up on a 80 cm height above reference ground plane, floor
                            standing equipment 10 cm raised above ground plane. Measurements have been
                            performed on each phase line and neutral line of the devices AC-power lines. The
                            EUT was power supplied with 110 V/60 Hz. The EUT was tested in the defined
                            operating mode and installed (connected) to accessory equipment according the
                            general description of use given by the applicant.

 Schematic:




                            Only schematic view, we refer to figure 6, 7 and 8 of ANSI C63.4-2014 for more details.



 Testing method:            Exploratory, preliminary measure-                  Final testing for power phases and
                            ments as a first step, determines the              critical frequencies (Margin to AV- or QP
                            worst-case phase line (neutral or phase)           limit lower than 3 dB) as a second step
                            as well as the most critical operating             includes measurements with receivers
                            mode of the equipment. A complete                  detector set to Quasi-Peak and Average.
                            frequency-sweep with PK-Detector is
                            performed on each current-carrying
                            conductor.
 Formula:                   VC= VR + CL (1)                          VC = measured Voltage –corrected value
                            M= LT-VC (2)                             VR = Receiver reading
                                                                     CL = Cable loss
                                                                     M = Margin
                                                                     LT = Limit
                            Values are in dB, positive margin means value is below limit.




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 9 of 19

4.2. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz

 Specification:             ANSI C63.4-2014 chapter 8, ANSI C63.10-2014 chapter 6.5

 General Description:       Evaluating the field emissions have to be done first by an exploratory emissions
                            measurement and a final measurement for most critical frequencies. The tests are
                            performed in a NSA-compliant semi anechoic room (SAR) recognized by the
                            regulatory commissions.

 Schematic:




 Testing method:            Exploratory, preliminary measurements                Final measurement on critical frequencies
                            The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                            on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                            device) of 0.8 m height which is placed on the       taining the EUT’s worst-case operation mode, cable
                            turntable. By rotating the turntable (range 0° to    position, etc.
                            360°, step 90°) and the EUT itself either on 3-
                            orthogonal axis (portable equipment) or 2-           First a frequency zoom around the critical frequency
                            orthogonal axis (defined operational position of     is done to locate the frequency more precisely. After
                            EUT) the emission spectrum and it’s                  this step, for all identified critical frequencies, the
                            characteristics was recorded with an EMI-            maximum peak was determined.
                            receiver, broadband antenna and software.
                                                                                 Following parameters were varied: the turntable
                            Measurement antenna: horizontal and vertical,        angle continuously in the range 0 to 360 degree, the
                            heights: 1,0 m and 1,82 m as worst-case              EUT itself either over 3-orthogonal axis (not
                            determined by an exploratory emission                defined usage position) or 2-orthogonal axis
                            measurements. The results are documented in a        (defined usage position). The measurement antenna
                            diagram. Critical frequencies (low margin to         height between 1 m and 4 m.
                            limit) are saved within a table for further
                            investigations. If various operating modes are       On the determined worst-case position, a final
                            supported, further investigations are made to find   measurement with necessary bandwidth and
                            the worst-case of them. Also the interconnection     detector according standard has been carried out.
                            cables and equipment position were varied in
                            order to maximize the emissions.

 Formula:                   EC = ER + AF + CL + DF - GA (1)           AF = Antenna factor
                                                                      CL = Cable loss
                            M = LT - EC         (2)                   DF = Distance correction factor (if used)
                                                                      EC = Electrical field – corrected value
                                                                      ER = Receiver reading
                                                                      GA = Gain of pre-amplifier (if used)
                                                                      LT = Limit
                                                                      M = Margin
                            All units are dB-units, positive margin means value is below limit.




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 10 of 19

4.3. Test system set-up for radiated electric field measurement above 1 GHz

 Specification:             ANSI C63.4-2014 chapter 8, ANSI C63.10-2014 chapter 6.6

 General Description:       Evaluating the field emissions have to be done first by an exploratory emissions
                            measurement and a final measurement for most critical frequencies. The tests are
                            performed in a CISPR 16-4 compliant fully anechoic room (FAR) recognized by
                            the regulatory commissions. The measurement distance was set to 3 meter for
                            frequencies up to 18 GHz and 2 meter above 18 GHz. A bicon-log or horn antenna
                            is used for frequency range 1 GHz to 40 GHz. Due to use of a fully anechoic room
                            the measurement antennas are set to fixed antenna height of 1.55 m and the site
                            validation criteria accord. CISPR 16-1-4:2010, Chapter 8.3 is fulfilled. The EUT is
                            aligned within 3 dB beamwidth of the measurement antenna, on big EUTs several
                            surface measurements are performed.

 Schematic:




 Testing method:            Exploratory, preliminary measurements                Final measurement on critical frequencies
                            The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                            on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                            device) of 1.55 m height which is placed on the      taining the EUT’s worst-case operation mode,
                            turntable. By rotating the turntable (range 0° to    cable position, etc.
                            360°, step 15°) and the EUT itself either on 3-
                            orthogonal axis (portable equipment) or 2-           First a frequency zoom around the critical
                            orthogonal axis (defined operational position of     frequency is done to locate the frequency more
                            EUT) the emission spectrum and it’s                  precisely. After this step, for all identified critical
                            characteristics was recorded with an EMI-            frequencies, the maximum peak was determined.
                            receiver, broadband antenna and software.
                            The measurements are performed in horizontal         Following parameters were varied: the turntable
                            and vertical polarization of the measurement         angle continuously in the range 0 to 360 degree,
                            antennas. The results are documented in a            the EUT itself either over 3-orthogonal axis (not
                            diagram. Critical frequencies (low margin to         defined usage position) or 2-orthogonal axis
                            limit) are saved within a table for further          (defined usage position). The measurement
                            investigations. If various operating modes are       antenna height is fixed to 1.55 m.
                            supported, further investigations are made to find
                            the worst-case of them. Also the interconnection     On the determined worst-case position, a final
                            cables and equipment position were varied in         measurement with necessary bandwidth and
                            order to maximize the emissions.                     detector according standard has been carried out.

 Formula:                   EC = ER + AF + CL + DF - GA (1)           EC = Electrical field – corrected value
                                                                      ER = Receiver reading
                            M = LT - EC         (2)                   M = Margin
                                                                      LT = Limit
                                                                      AF = Antenna factor
                                                                      CL = Cable loss
                                                                      DF = Distance correction factor (if used)
                                                                      GA = Gain of pre-amplifier (if used)
                            All units are dB-units, positive margin means value is below limit.




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 11 of 19


5. Measurements

 5.1. General Limit - Conducted emissions on AC-Power lines
5.1.1. Test location and equipment
test location    CETECOM Essen (Chapter 2.2.1)     Please see Chapter 2.2.2              Please see Chapter 2.2.3
 test site       333 EMI field  348 EMI cond.
 receiver        001 ESS           377 ESCS 30    489   ESU 40      620 ESU 26
 LISN            005 ESH2-Z5  007 ESH3-Z6         300   ESH3-Z5 & 50 used for AE       no LISN for AE
 signaling       392 MT8820A  436 CMU             547   CMU         594 CMW
 line voltage    230 V 50 Hz via public mains      060    120 V 60 Hz via PAS 5000



5.1.2. Requirements
            FCC               Part 15, Subpart B, §15.107
             IC               RSS-Gen Issue 4, Chapter 8.8, Table 3
           ANSI               C63.4-2009, § 5.2, 6, 7
                Frequency                   Conducted limit Class B                     Conducted limit Class A
                  [MHz]         QUASI-Peak [dBµV]          AVERAGE [dBµV]       QUASI-Peak [dBµV]      AVERAGE [dBµV]
     Limit      0.15 – 0.5            66 to 56*                 56 to 46*              79                       66
                  0.5 – 5                56                        46                  73                       60
                  5 – 30                 60                        50                  73                       60
   Remark: * decreases with the logarithm of the frequency



5.1.3. Test condition and test set-up
Signal link to test system (if used):    air link  cable connection 
EUT-grounding                            none  with power supply  additional connection
Equipment set up                         table top                        floor standing
                                        (40 cm distance to reference       EUT stands isolated on reference ground plane (floor)
                                        ground plane (wall)
Climatic conditions                     Temperature: (22±3°C)             Rel. humidity: (40±20)%
                                         9 – 150 kHz,            RBW = 200 Hz, Step = 61 Hz
                   Scan data             150 kHz – 30 MHz        RBW = 9 kHz,       Step = 4 kHz
 EMI-Receiver or                         other:
 Analyzer settings Scan-Mode            6 dB EMI-Receiver Mode
                   Pre-measurement      Peak detector, Repetitive-Scan, max-hold, sweep-time 50 µs per frequency point
                   Final measurement    Average & Quasi-peak detector at critical frequencies
General measurement procedures          Please see chapter “Test system set-up for AC power line conducted emissions measurements”



5.1.4. Measurement results
The results are presented below in summary form only. For more information please see the diagrams
  EUT                set-up no.:                   set-up 1
                   EUT
  Diagram                                           Power Additional (scan-) information or        Result
              operating mode      Used Detector
     No.                                              line               remarks
             no. or commend
                   EUT            Peak (pre-scan)
                                                              Pre-test Fast scan, Maxhold;
    1.01      operating mode  AV (final)           L1/ N                                          passed
                                  QP   (final)             CAV   + QP- Final Measurement
                     1




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 12 of 19

5.2. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz
5.2.1. Test location and equipment
 test location      CETECOM Essen (Chapter. 2.2.1)           Please see Chapter. 2.2.2                 Please see Chapter. 2.2.3
 test site          441 EMI SAR  487 SAR NSA
 receiver           377 ESCS30        001 ESS               489 ESU 40       620 ESU 26
 spectr. analys.    584 FSU           120 FSEM              264 FSEK
 antenna            574 BTA-L         133 EMCO3115          302 BBHA9170  289 CBL 6141      030 HFH-Z2  477 GPS
 signaling          392 MT8820A  371 CBT32                  547 CMU          594 CMW
 otherwise          400 FTC40x15E  401 FTC40x15E            110 USB LWL  482 Filter Matrix
 DC power           456 EA 3013A  457 EA 3013A              459 EA 2032-50  268 EA- 3050    494 AG6632A  498 NGPE
 line voltage       230 V 50 Hz via public mains             060 120 V 60 Hz via PAS 5000



5.2.2. Requirements/Limits
                                                 Part 15 Subpart B, §15.109, class B
                     FCC
                                                 Part 15 Subpart C, §15.209 @ frequencies defined in §15.205
                                                 RSS-Gen., Issue 4, Chapter 8.9, Table 4+6
                      IC
                                                 ICES-003, Issue 5
                                                 C63.4-2014
                     ANSI                        C63.10-2014
                                                 C63.10-2013
                                                                          Radiated emissions limits, 3 meters
                      Frequency [MHz]
                                                         QUASI Peak [µV/m]                             QUASI-Peak [dBµV/m]
                             30 - 88                              100                                         40.0
     Limit
                            88 - 216                              150                                         43.5
                           216 - 960                              200                                         46.0
                           above 960                              500                                         49.0



5.2.3. Test condition and measurement test set-up
Signal link to test system (if used):          air link      cable connection         none
 EUT-grounding                                 none          with power supply  additional connection
 Equipment set up                              table top 0.8m height                  floor standing
 Climatic conditions                          Temperature: (22±3°C)                   Rel. humidity: (40±20)%
 EMI-Receiver         Scan frequency range:    30 – 1000 MHz  other:
(Analyzer) Settings Scan-Mode                  6 dB EMI-Receiver Mode  3 dB spectrum analyser mode
                      Detector                Peak / Quasi-peak
                      RBW/VBW                 100 kHz/300 kHz
                      Mode:                   Repetitive-Scan, max-hold
                      Scan step               80 kHz
                      Sweep-Time              Coupled – calibrated display if continuous tx-signal otherwise adapted to EUT’s individual
                                              duty-cycle
 General measurement procedures               Please see chapter “Test system set-up for electric field measurement in the range 30 MHz
                                               to 1 GHz”



5.2.4. MEASUREMENT RESULTS

The results are presented below in summary form only. For more information please see diagrams.

Table of measurement results:
                                                                                                                       Result
   Dia-                        Set-     OP-                                             Used detector
             Frequency
   gram                         up      mode                   Remark
               range
    no.                        no.       no.
                                                                                       PK     AV     QP
             30 MHz –
   3.01                         1         1           Video-Recording Mode                                          passed
              1 GHz
Remark: --




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 13 of 19

5.3. General Limit - Radiated emissions, above 1 GHz
5.3.1. Test location and equipment FAR
 test site          441 EMI SAR  348 EMI cond.                 443   EMI FAR     347 Radio.lab.  337 OATS                
 spectr. analys.    584 FSU          120 FSEM                  264   FSEK        489 ESU 40                              
 antenna meas       123 HUF-Z2       132 HUF-Z3                030   HFH-Z2      376 BBHA9120E                            
 antenna meas       071 HUF-Z2       020 EMCO3115              549   HL025       303 BBHA9170                            
 multimeter         341 Fluke 112                                                                                        
 signaling          392 MT8820A  371 CBT32                     547   CMU         594 CMW
 DC power           086 LNG50-10  087 EA3013                   354   NGPE 40  349 car battery  350 Car battery           
 line voltage       230 V 50 Hz via public mains                060   120 V 60 Hz via PAS 5000



5.3.2. Requirements/Limits
                             Part 15 Subpart B, §15.109 class B
          FCC                Part 15 Subpart C, §15.209 for frequencies defined in §15.205
                             Part 15 Subpart C, §15.407(b)(1)(2)(3) 9

                             RSS-Gen., Issue 4, Chapter 8.9, Table 4+6
           IC                RSS-210, Issue 8, Annex 8
                             RSS-210, Issue 8, Annex 9
                             C63.4-2014
          ANSI               C63.10-2014
                             C63.10-2013
                                                                                     Limits
       Frequency                         AV                                AV                         Peak                      Peak
         [MHz]                         [µV/m]                           [dBµV/m]                     [µV/m]                  [dBµV/m] or
                                                                                                                             [dBm/MHz]
      above 1 GHz
           or
                                        500                               54.0                        5000                   74.0 dBµV/m
    RSS-Gen., Issue
   4, §8.10 - Table 6

5.3.3. Test condition and measurement test set-up
 Signal ink to test system (if used):                air link      cable connection
 EUT-grounding                                       none          with power supply  additional connection
 Equipment set up                                    table top 1.5m height                  floor standing
 Climatic conditions                                Temperature: (22±3°C)                   Rel. humidity: (40±20)%
Spectrum- Scan frequency range:                      1 – 18 GHz  18 – 25 GHz  18 – 40 GHz  other:
Analyzer      Scan-Mode                              6 dB EMI-Receiver Mode  3 dB Spectrum analyser Mode
settings      Detector                              Peak and Average
              RBW/VBW                               1 MHz / 3 MHz
              Mode:                                 Repetitive-Scan, max-hold
              Scan step                             400 kHz
              Sweep-Time                            Coupled – calibrated display if CW signal otherwise adapted to EUT’s individual duty-cycle
General measurement procedures                      Please see chapter “Test system set-up for radiated electric field measurements above 1 GHz”



5.3.4. Measurement Results

The results are presented below in summary form only. For more information please see diagrams.

   Dia-                         Set-       OP-                                                Used detector                   Result
                Frequency
   gram                          up        mode                     Remark
                  range
    no.                         no.         no.
                                                                                              PK   AV      QP

   4.01         1-18GHz           1             1          Video-Recording Mode                                           passed

   4.02         18-40GHz          1             1          Video-Recording Mode                                           passed




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 14 of 19

5.4. Measurement uncertainties

The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate
coverage factor k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account and
it’s contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                       Calculated uncertainty based on a
      RF-Measurement          Reference        Frequency range                                                    Remarks
                                                                           confidence level of 95%
  Conducted emissions                    9 kHz - 150 kHz           4.0 dB
                            CISPR 16-2-1                                                                              -
  (U CISPR)                              150 kHz - 30 MHz          3.6 dB
  Radiated emissions                     30 MHz - 1 GHz            4.2 dB
                            CISPR 16-2-3                                                                           E-Field
  Enclosure                              1 GHz - 18 GHz            5.1 dB
  Disturbance power         CISPR 16-2-2 30 MHz - 300 MHz          -                                                  -
                                                                                                                Substitution
  Power Output radiated           -          30 MHz - 4 GHz        3.17 dB
                                                                                                                method
                                                                   Cel- Cel-
                                             Set-up No.                         BT1 W1          W2         --
                                                                    C1     C2
  Power Output conducted          -          9 kHz - 12.75 GHz     N/A 0.60      --   0.25      --         --         -
                                             12.75 - 26.5GHz       N/A 0.82      --    --       --         --
  Conducted emissions             -          9 kHz - 2.8 GHz       0.70 N/A 0.70       --      0.69        --    N/A - not
  on RF-port                                 2.8 GHz - 12.75GHz    1.48 N/A 1.51       --      1.43        --    applicable
                                             12.75 GHz - 18GHz     1.81 N/A 1.83       --      1.77        --
                                             18 GHz - 26.5GHz      1.83 N/A 1.85       --      1.79        --
                                                                   0.1272 ppm (Delta Marker)                    Frequency
  Occupied bandwidth              -          9 kHz - 4 GHz                                                      error
                                                                   1.0 dB                                       Power
                                  -                                0.1272 ppm (Delta Marker)                    Frequency
  Emission bandwidth                         9 kHz - 4 GHz                                                      error
                                  -                                See above: 0.70 dB                           Power
  Frequency stability             -          9 kHz - 20 GHz        0.0636 ppm                                          -
                                             150 kHz - 30 MHz      5.0 dB                                       Magnetic
  Radiated emissions                         30 MHz - 1 GHz        4.2 dB                                       field
                                  -
  Enclosure                                  1 GHz - 20 GHz        3.17 dB                                      E-field
                                                                                                                Substitution
Table: measurement uncertainties, valid for conducted/radiated measurements




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 15 of 19


6. Abbreviations used in this report
 The abbreviations
 ANSI                    American National Standards Institute
 AV , AVG, CAV           Average detector
 EIRP                    Equivalent isotropically radiated power, determined within a separate measurement
 EGPRS                   Enhanced General Packet Radio Service
 EUT                     Equipment Under Test
 FCC                     Federal Communications Commission, USA
 IC                      Industry Canada
 n.a.                    not applicable
 Op-Mode                 Operating mode of the equipment
 PK                      Peak
 RBW                     resolution bandwidth
 RF                      Radio frequency
 RSS                     Radio Standards Specification, Dokuments from Industry Canada
 Rx                      Receiver
 TCH                     Traffic channel
 Tx                      Transmitter
 QP                      Quasi peak detector
 VBW                     Video bandwidth
 ERP                     Effective radiated power




7. Accreditation details of CETECOM’s laboratories and test sites

 Ref.-   Accreditation                  Valid for laboratory area or test site
 No.      Certificate                                                                               Accreditation Body
 -          D-PL-                                                                             DAkkS, Deutsche
                         All laboratories and test sites of CETECOM GmbH, Essen
         12047-01-01                                                                          Akkreditierungsstelle GmbH
 337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
 487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                         FCC, Federal Communications
      MRA US-EU
 558                 Radiated Measurements above 1 GHz, 3 m (FAR)                             Commission
          0003
 348                 Mains Ports Conducted Interference Measurements                          Laboratory Division, USA
 348                 Telecommunication Ports Conducted Interference Measurem.
 337    3462D-1      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
 487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                         IC, Industry Canada Certification
 550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)                          and Engineering Bureau
 558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
 487     R-4452      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                              VCCI, Voluntary Control Council
 550    G-20013      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                              for Interference by Information
 348    C-20009      Mains Ports Conducted Interference Measurements
                                                                                              Technology Equipment, Japan
 348     T-20006     Telecommunication Ports Conducted Interference Measurem.
 OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 16 of 19


8. Instruments and Ancillary
8.1. Used equipment “CTC”
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory
equipment.


8.1.1. Test software and firmware of equipment
  Ref.-No.




                            Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


 001         EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
 012         Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
 013         Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
 017         Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
 053         Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
 119         RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
 140         Signal Generator                          SMHU                     831314/006          Firm.= 3.21
 261         Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
 262         Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
 263         Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
 264         Spectrum Analyzer                         FSEK 30                  826939/005          Bios=2.1, Analyzer= 3.20
                                                                                                    UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
 295         Racal Digital Radio Test Set              6103                     1572
                                                                                                    SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                    R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
 298         Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                    all band used
 323         Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
 331         Climatic Test Chamber -40/+80 Grad        HC 4055                  43146               TSI 1.53
 335         CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
 340         Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
 355         Power Meter                               URV 5                    891310/027          Firm.= 1.31
 365         10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
 366         Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
 371         Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
 377         EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
 378         Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
 389         Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                    Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
 392         Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                    4.52#002
                                                                                                    R&S Test Firmware Base=5.14, Mess-Software=
 436         Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                    GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
 441         CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
 442         CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                       System CTC-FAR-EMI-
 443         CTC-FAR-EMI-RSE                                                    -                   EMC 32 Ver. 9.15.00
                                                       RSE
 444         CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 9.15.00
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
 460         Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used,
 489         EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
 491         ESD Simulator dito                        ESD dito                 dito307022          V 2.30
 524         Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
 526         Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
 527         Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
 528         Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
 546         Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                    R&S Test Firmware Base=V5.1403 (current Testsoftw.,
 547         Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                    f. all band used, GSM = 5.14 WCDMA: = 5.14
 584         Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                    R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
 597         Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                    not installed, Mainboard= µP1=V.850
 598         Spectrum Analyzer                         FSEM 30 (Reserve)        831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
 620         EMI Test Receiver                         ESU 26                   100362              4.43_SP3
 642         Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
                                                                                                    CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
 692         Bluetooth Tester                          CBT 32                   100236
                                                                                                    RF)




TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 17 of 19



8.1.2. Single instruments and test systems
  Ref.-No.




                                                                                                                               calibration
                                                                                                                               Interval of



                                                                                                                                                 Remark
                            Equipment                             Type               Serial-No.             Manufacturer                                      Cal
                                                                                                                                                              due

 001         EMI Test Receiver                         ESS                     825132/017              Rohde & Schwarz         12 M          -            16.05.2018
 005         AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                 861741/005              Rohde & Schwarz         12 M          -            15.05.2018
 007         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 892563/002              Rohde & Schwarz         12 M          -            17.05.2018
 009         Power Meter (EMS-radiated)                NRV                     863056/017              Rohde & Schwarz         24 M          -            15.05.2019
 016         Line Impedance Simulating Network         Op. 24-D                B6366                   Spitzenberger+Spies     36 M          -            30.05.2019
 020         Horn Antenna 18 GHz (Subst 1)             3115                    9107-3699               EMCO                    36/12 M       -            31.07.2017
 021         Loop Antenna (H-Field)                    6502                    9206-2770               EMCO                    36 M          -            30.04.2018
 030         Loop Antenna (H-field)                    HFH-Z2                  879604/026              Rohde & Schwarz         36 M          -            30.04.2018
 033         RF-current probe (100kHz-30MHz)           ESH2-Z1                 879581/18               Rohde & Schwarz         24 M          -            15.05.2019
 057         relay-switch-unit (EMS system)            RSU                     494440/002              Rohde & Schwarz         pre-m         1a
 060         power amplifier (DC-2kHz)                 PAS 5000                B6363                   Spitzenberger+Spies     -             3
                                                       WRCT 1900/2200-5/40-
 066         notch filter (WCDMA; FDD1)                                        5                       Wainwright GmbH         12 M          1g           30.06.2017
                                                       10EEK
 086         DC - power supply, 0 -10 A                LNG 50-10               -                       Heinzinger Electronic   pre-m         2
 087         DC - power supply, 0 -5 A                 EA-3013 S               -                       Elektro Automatik       pre-m         2
 091         USB-LWL-Converter                         OLS-1                   007/2006                Ing. Büro Scheiba       -             4
 099         passive voltage probe                     ESH2-Z3                 299.7810.52             Rohde & Schwarz         36 M          -            30.04.2018
 100         passive voltage probe                     Probe TK 9416           without                 Schwarzbeck             36 M          -            30.04.2018
 110         USB-LWL-Converter                         OLS-1                   -                       Ing. Büro Scheiba       -             4
 119         RT Harmonics Analyzer dig. Flickermeter   B10                     G60547                  BOCONSULT               36 M          -            30.05.2019
 133         horn antenna 18 GHz (Meas 1)              3115                    9012-3629               EMCO                    36 M          1c           10.03.2020
 134         horn antenna 18 GHz (Subst 2)             3115                    9005-3414               EMCO                    36 M          -            10.03.2020
 136         adjustable dipole antenna (Dipole 1)      3121C-DB4               9105-0697               EMCO                    36 M          -            30.04.2018
 140         Signal Generator                          SMHU                    831314/006              Rohde & Schwarz         24 M          -            30.05.2018
 248         attenuator                                SMA 6dB 2W              -                       Radiall                 pre-m         2
 249         attenuator                                SMA 10dB 10W            -                       Radiall                 pre-m         2
 252         attenuator                                N 6dB 12W               -                       Radiall                 pre-m         2
 256         attenuator                                SMA 3dB 2W              -                       Radiall                 pre-m         2
 257         hybrid                                    4031C                   04491                   Narda                   pre-m         2
 260         hybrid coupler                            4032C                   11342                   Narda                   pre-m         2
 261         Thermal Power Sensor                      NRV-Z55                 825083/0008             Rohde & Schwarz         24 M          -            30.05.2018
 262         Power Meter                               NRV-S                   825770/0010             Rohde & Schwarz         24 M          -            30.05.2018
 263         Signal Generator                          SMP 04                  826190/0007             Rohde & Schwarz         36 M          -            30.05.2019
 265         peak power sensor                         NRV-Z33, Model 04       840414/009              Rohde & Schwarz         24 M          -            30.05.2018
 266         Peak Power Sensor                         NRV-Z31, Model 04       843383/016              Rohde & Schwarz         24 M          -            30.05.2018
 267         notch filter GSM 850                      WRCA 800/960-6EEK       9                       Wainwright GmbH         pre-m         2
 270         termination                               1418 N                  BB6935                  Weinschel               pre-m         2
 271         termination                               1418 N                  BE6384                  Weinschel               pre-m         2
 272         attenuator (20 dB) 50 W                   Model 47                BF6239                  Weinschel               pre-m         2
 273         attenuator (10 dB) 100 W                  Model 48                BF9229                  Weinschel               pre-m         2
 274         attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W   BG0321                  Weinschel               pre-m         2
 275         DC-Block                                  Model 7003 (N)          C5129                   Weinschel               pre-m         2
 276         DC-Block                                  Model 7006 (SMA)        C7061                   Weinschel               pre-m         2
 279         power divider                             1515 (SMA)              LH855                   Weinschel               pre-m         2
 287         pre-amplifier 25MHz - 4GHz                AMF-2D-100M4G-35-10P    379418                  Miteq                   12 M          1c           30.06.2017
 291         high pass filter GSM 850/900              WHJ 2200-4EE            14                      Wainwright GmbH         12 M          1c           30.06.2017
 298         Univ. Radio Communication Tester          CMU 200                 832221/091              Rohde & Schwarz         pre-m         3
 300         AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                 892 239/020             Rohde & Schwarz         12 M          -            17.05.2018
 301         attenuator (20 dB) 50W, 18GHz             47-20-33                AW0272                  Lucas Weinschel         pre-m         2
 302         horn antenna 40 GHz (Meas 1)              BBHA9170                155                     Schwarzbeck             36 M          -            14.03.2020
 303         horn antenna 40 GHz (Subst 1)             BBHA9170                156                     Schwarzbeck             36 M          -            20.03.2020
 331         Climatic Test Chamber -40/+180 Grad       HC 4055                 43146                   Heraeus Vötsch          24 M          -            30.10.2018
 341         Digital Multimeter                        Fluke 112               81650455                Fluke                   24 M          -            30.05.2018
 342         Digital Multimeter                        Voltcraft M-4660A       IB 255466               Voltcraft               24 M          -            17.05.2019
 347         laboratory site                           radio lab.              -                       -                       -             5
 348         laboratory site                           EMI conducted           -                       -                       -             5
 354         DC - Power Supply 40A                     NGPE 40/40              448                     Rohde & Schwarz         pre-m         2
 355         Power Meter                               URV 5                   891310/027              Rohde & Schwarz         24 M          -            30.05.2018
 357         power sensor                              NRV-Z1                  861761/002              Rohde & Schwarz         24 M          -            24.05.2019
 371         Bluetooth Tester                          CBT32                   100153                  R&S                     36 M          -            30.05.2019
 373         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 100535                  Rohde & Schwarz         12 M          -            17.05.2018
 377         EMI Test Receiver                         ESCS 30                 100160                  Rohde & Schwarz         12 M          -            15.05.2018
 389         Digital Multimeter                        Keithley 2000           0583926                 Keithley                24 M          -            30.04.2017
 392         Radio Communication Tester                MT8820A                 6K00000788              Anritsu                 12 M          -            18.05.2018
                                                                               126.0604.0003.3.3.3.2   LUFFT Mess u.
 405         Thermo-/Hygrometer                        OPUS 10 THI                                                             24 M          -            30.03.2019
                                                                               2                       Regeltechnik
 431         Model 7405                                Near-Field Probe Set    9305-2457               EMCO                    -             4
 436         Univ. Radio Communication Tester          CMU 200                 103083                  Rohde & Schwarz         12 M          -            24.05.2018
 439         UltraLog-Antenna                          HL 562                  100248                  Rohde & Schwarz         36 M          -            10.03.2020


TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 18 of 19
  Ref.-No.




                                                                                                                                   calibration
                                                                                                                                   Interval of



                                                                                                                                                     Remark
                              Equipment                           Type                    Serial-No.             Manufacturer                                     Cal
                                                                                                                                                                  due

                                                       System CTC-FAR-EMI-                                 ETS-Lindgren /
 443         CTC-FAR-EMI-RSE                                                       -                                               12 M          5            30.03.2018
                                                       RSE                                                 CETECOM
 454         Oscilloscope                              HM 205-3                    9210 P 29661            Hameg                   -             4
 456         DC-Power supply 0-5 A                     EA 3013 S                   207810                  Elektro Automatik       pre-m         2
 459         DC -Power supply 0-5 A , 0-32 V           EA-PS 2032-50               910722                  Elektro Automatik       pre-m         2
 460         Univ. Radio Communication Tester          CMU 200                     108901                  Rohde & Schwarz         12 M          -            16.06.2018
 463         Universal source                          HP3245A                     2831A03472              Agilent                 -             4
 466         Digital Multimeter                        Fluke 112                   89210157                Fluke USA               24 M          -            30.05.2018
 467         Digital Multimeter                        Fluke 112                   89680306                Fluke USA               36 M          -            30.04.2018
 468         Digital Multimeter                        Fluke 112                   90090455                Fluke USA               36 M          -            30.04.2018
 477         ReRadiating GPS-System                    AS-47                       -                       Automotive Cons. Fink   -             3
 480         power meter (Fula)                        NRVS                        838392/031              Rohde & Schwarz         24 M          -            16.05.2019
 482         filter matrix                             Filter matrix SAR 1         -                       CETECOM (Brl)           -             1d
                                                       System EMI field (SAR)                              ETS Lindgren /
 487         System CTC NSA-Verification SAR-EMI                                   -                                               24 M          -            31.03.2019
                                                       NSA                                                 CETECOM
 489         EMI Test Receiver                         ESU40                       1000-30                 Rohde & Schwarz         12 M          -            18.05.2019
                                                       WRCG 1709/1786-
 502         band reject filter                                                    SN 9                    Wainwright              pre-m         2
                                                       1699/1796-
 503         band reject filter                        WRCG 824/849-814/859-       SN 5                    Wainwright              pre-m         2
 517         relais switch matrix                      HF Relais Box Keithley      SE 04                   Keithley                pre-m         2
 523         Digital Multimeter                        L4411A                      MY46000154              Agilent                 24 M          -            18.05.2019
 529         6 dB Broadband resistive power divider    Model 1515                  LH 855                  Weinschel               pre-m         2
 530         10 dB Broadband resistive power divider   R 416110000                 LOT 9828                -                       pre-m         2
 546         Univ. Radio Communication Tester          CMU 200                     106436                  R&S                     12 M          -            30.03.2018
 547         Univ. Radio Communication Tester          CMU 200                     835390/014              Rohde & Schwarz         12 M          -            05.07.2018
 549         Log.Per-Antenna                           HL025                       1000060                 Rohde & Schwarz         36/12 M       -            31.07.2018
             System CTC S-VSWR Verification SAR-       System EMI Field SAR S-                             ETS
 550                                                                               -                                               24 M          -            30.03.2019
             EMI                                       VSWR                                                Lindgren/CETECOM
                                                       System CTC FAR S-
 558         System CTC FAR S-VSWR                                                 -                       CTC                     24 M          -            08.08.2019
                                                       VSWR
 574         Biconilog Hybrid Antenna                  BTA-L                       980026L                 Frankonia               36/12 M       -            31.03.2019
 584         Spectrum Analyzer                         FSU 8                       100248                  Rohde & Schwarz         pre-m         -
 597         Univ. Radio Communication Tester          CMU 200                     100347                  Rohde & Schwarz         pre-m         -
 600         power meter                               NRVD (Reserve)              834501/018              Rohde & Schwarz         24 M          -            17.05.2019
 601         medium-sensitivity diode sensor           NRV-Z5 (Reserve)            8435323/003             Rohde & Schwarz         24 M          -            15.05.2019
 602         peak power sensor                         NRV-Z32 (Reserve)           835080                  Rohde & Schwarz         24 M          -
 611         DC power supply                           E3632A                      KR 75305854             Agilent                 pre-m         2
 612         DC power supply                           E3632A                      MY 40001321             Agilent                 pre-m         2
 613         Attenuator                                R416120000 20dB 10W         Lot. 9828               Radiall                 pre-m         2
 616         Digitalmultimeter                         Fluke 177                   88900339                Fluke                   24 M          -            30.05.2018
 617         Power Splitter/Combiner                   ZFSC-2-2-S+                 S F987001108            Mini Circuits           -             2
 618         Power Splitter/Combiner                   50PD-634                    600994                  JFW Industries USA      -             2
 619         Power Splitter/Combiner                   50PD-634                    600995                  JFW Industries, USA     -             3
 620         EMI Test Receiver                         ESU 26                      100362                  Rohde-Schwarz           12 M          -            16.05.2018
 621         Step Attenuator 0-139 dB                  RSP                         100017                  Rohde & Schwarz         pre-m         2
 625         Generic Test Load USB                     Generic Test Load USB       -                       CETECOM                 -             2
                                                                                   201.0999.9302.6.4.1.4
 627         data logger                               OPUS 1                                              G. Lufft GmbH           24 M          -            30.03.2019
                                                                                   3
 634         Spectrum Analyzer                         FSM (HF-Unit)               826188/010              Rohde & Schwarz         pre-m         2
                                                       HDMI cable with Ethernet
 637         High Speed HDMI with Ethernet 1m                                      -                       KogiLink                -             2
                                                       1m
 638         HDMI Kabel with Ethernet 1,5 m flach      HDMI cable with Ethernet    -                       Reichelt                -             2
 640         HDMI cable 2m rund                        HDMI cable 2m rund          -                       Reichelt                -             2
 641         HDMI cable with Ethernet                  Certified HDMI cable with   -                       PureLink                -             2
 642         Wideband Radio Communication Tester       CMW 500                     126089                  Rohde&Schwarz           12 M          -            24.05.2018
 644         Amplifierer                               ZX60-2534M+                 SN865701299             Mini-Circuits           -             -
 670         Univ. Radio Communication Tester          CMU 200                     106833                  Rohde & Schwarz         24 M          -            30.05.2018
 671         DC-power supply 0-5 A                     EA-3013S                    -                       Elektro Automatik       pre-m         2
 678         Power Meter                               NRP                         101638                  Rohde&Schwarz           pre-m         -
 683         Spectrum Analyzer                         FSU 26                      200571                  Rohde & Schwarz         12 M          -            17.05.2018
                                                                                                           Narda Safety Test
 686         Field Analyzer                            EHP-200A                    160WX30702                                      24 M          -            29.03.2019
                                                                                                           Solutions
 687         Signal Generator                          SMF 100A                    102073                  Rohde&Schwarz           12 M          -            17.05.2018
 688         Pre Amp                                   JS-18004000-40-8P           1750117                 Miteq                   pre-m         -
 690         Spectrum Analyzer                         FSU                         100302/026              Rohde&Schwarz           12 M          -            16.05.2018
 691         OSP120 Base Unit                          OSP120                      101183                  Rohde & Schwarz         12 M          -            22.05.2018
 692         Bluetooth Tester                          CBT 32                      100236                  Rohde & Schwarz         36 M          -            29.05.2020
 693         TS8997                                    CTC-Radio Lab 1_TS8997      -                       Rohde&Schwarz           12 M          5            06.06.2018
 697         Power Splitter                            ZN4PD-642W-S+               165001445               Mini-Circuits           -             2
 701         CMW500 wide. Radio Comm.                  CMW500                      158150                  Rohde & Schwarz         12 M          -            01.05.2018
                                                       MA 4010-KT080-XPET-         MA4170-KT100-
 703         INNCO Antennen Mast                                                                           INNCO                   pre-m         -
                                                       ZSS3                        XPET-
 704         INNCON Controller                         CO 3000-4port               CO3000/933/3841051      INNCO Systems GmBh      pre-m         -


TR17-1-0021101T14.docx


Test Report 17-1-0021101T14, Page 19 of 19
  Ref.-No.




                                                                                                                                          calibration
                                                                                                                                          Interval of



                                                                                                                                                            Remark
                           Equipment                               Type                     Serial-No.              Manufacturer                                         Cal
                                                                                                                                                                         due

                                                                                     6/L
 711         Harmonic Mixer 90 GHz - 140GHz              RPG FS-Z140                 101004                    RPG                       12 M           -            22.02.2018
 712         Harmonic Mixer 75 GHz - 110GHz              FS-Z110                     101468                    Rohde & Schwarz           12 M           -            22.02.2018
 713         Harmonic Mixer, 50 GHz - 75GHz              FS-Z75                      101022                    Rohde & Schwarz           12 M           -            22.05.2018
 714         Signal Analyzer 67GHz                       FSW67                       104023                    Rohde & Schwarz           24 M           -            03.03.2019
                                                                                                               RPG Radiometer
 715         Harmonic Mixer, 140 GHz - 220GHz            FS-Z220                     101009                                              12 M           -            03.08.2018
                                                                                                               Physics
 716         Harmonic Mixer 220 GHz to 325 GHZ           FS-Z325                     101005                    RPG Radiometer Physics    12 M           -            13.02.2018
 747         Spectrum Analyzer                           FSU 26                      200152                    Rohde & Schwarz           12 M           -            18.05.2018
 748         Pickett-Potter Horn Antenna                 FH-PP 4060                  010001                    Radiometer Physiscs       -              -
 749         Pickett-potter Horn Antenna                 FH-PP 60-90                 010003                    Radiometer Physics        -              -
 750         Pickett-Potter Horn Antenna                 FH-PP 140-220               010011                    Radiometer Physics        -              -




8.1.3. Legend
 Note / remarks                            Calibrated during system calibration:
                                1a         System CTC-SAR-EMS (Ref.-No. 442)
                                1b         System-CTC-EMS-Conducted (Ref.-No. 335)
                                1c         System CTC-FAR-EMI-RSE (Ref.-No . 443)
                                1d         System CTC-SAR-EMI (Ref.-No . 441)
                                1e         System CTC-OATS (EMI radiated) (Ref.-No. 337)
                                1f         System CTC-CTIA-OTA (Ref.-No . 420)
                                1g         System CTC-FAR-EMS (Ref.-No . 444)
                                2          Calibration or equipment check immediately before measurement
                                3          Regulatory maintained equipment for functional check or support purpose
                                4          calibrationequipment
                                           Ancillary   of this equipment
                                                                 without has no effect
                                                                         calibration   onmechanical
                                                                                     e.g. measuring result
                                                                                                    equipment or monitoring equipment
                                5          Test System


 Interval of calibration        12 M          12 month
                                24 M          24 month
                                36 M          36 month
                                24/12 M       Calibration every 24 months, between this every 12 months internal validation
                                36/12 M       Calibration every 36 months, between this every 12 months internal validation
                                Pre-m      Check before starting the measurement
                                -          Without calibration




9. Versions of test reports (change history)

             Version          Applied changes                                                                                           Date of release
               --             Inital release                                                                                             2018-01-31
               --             --                                                                                                              --
               --             --                                                                                                              --




TR17-1-0021101T14.docx



Document Created: 2018-02-08 20:41:43
Document Modified: 2018-02-08 20:41:43

© 2024 FCC.report