Test Report

FCC ID: N52-SDR-ICS-437FN

Test Report

Download: PDF
FCCID_4168807

     ESTECH CO., LTD.
    http://www.estech.co.kr




  FCC TEST REPORT

           Product Name               Repeater

           Model Name            SDR-ICS-43-7FN

           Applicant            ADRF KOREA INC.

           FCC ID              N52-SDR-ICS-437FN




             ESTECH CO., LTD
        Rm. 1015 World Venture Center, 426-5 Gasan-dong, Geumcheon-gu,
          Seoul, 153-803, Korea. Tel:82-2-867-3201, Fax:82-2-867-3204




Report Number :                 EST-P25-IO2-F04
ESTRFC1901-002                     (2016.01.01)                          1 of 32


          ESTECH CO., LTD.
                                                                                           FCC ID : N52-SDR-ICS-437FN
         http://www.estech.co.kr

                                        FCC Test Report
   Report
                 ESTRFC1901-002
   Number

                 Company Name ADRF Korea, inc
  Applicant
                 Address             5-5, Mojeon-Ri, Backsa-Myun, Icheon-City, Kyunggi-Do, Korea

                 Product Name        Repeater

   Product       Model No.           SDR-ICS-43-7FN                  Manufacturer          ADRF Korea, inc

                                                                     Country of
                 Serial No.          Non                                                       KOREA
                                                                     origin
                                                                                           2018-12-01~
     Other       Issued Date         2019-01-10                      Tested Date
                                                                                           2019-01-10

  Test Result                                                      Pass




   Standard                                                 FCC PART 90




  Tested by              Engineering Manager I.K. Hong                              (Signature)

 Approved by             Engineering manager Keum-Bum Lee                  (Signature)


                                    ESTECH CO., LTD
                              Rm. 1015 World Venture Center, 426-5 Gasan-dong, Geumcheon-gu,
                                Seoul, 153-803, Korea. Tel:82-2-867-3201, Fax:82-2-867-3204

o This is certified that the above mentioned products have been tested for the sample provided by client.

o No part of this document may not be duplicated or reproduced by any means without the express
  written permission of Estech Co., Ltd.




    Report Number :                                EST-P25-IO2-F04
    ESTRFC1901-002                                    (2016.01.01)                                       2 of 32


    ESTECH CO., LTD.
                                                                        FCC ID : N52-SDR-ICS-437FN
   http://www.estech.co.kr

           Contents

 1. General Information                                                          Page 4

 2. Laboratory Information                                                       Page 5

 3. Summary of Test Results                                                      Page 5

 4. Measuring AGC threshold level Power and Conducted RF Output Power            Page 6

 5. Occupied Bandwidth                                                           Page 10

 6. Out of Band Rejection                                                        Page 14

 7. Spurious Emission at Antenna Terminal                                        Page 17

 8. Radiated Spurious Emission                                                   Page 28




Report Number :                        EST-P25-IO2-F04
ESTRFC1901-002                            (2016.01.01)                                    3 of 32


       ESTECH CO., LTD.
                                                                        FCC ID :   N52-SDR-ICS-437FN
       http://www.estech.co.kr


1. General Information
     1.1 EUT Description

     FCC ID                              N52-SDR-ICS-437FN
     Product Name                              Repeater
     Model Name                            SDR-ICS-43-7FN
                                  Downlink : 758.00MHz ~ 768.00 MHz
     Frequency
                                   Uplink : 788.00MHz ~ 798.00 MHz
     Duty                                       100 %
     Power Rating                    Input: 110~240VAC 50~60Hz
     Antenna Gain                Manufacturer does not Provide antenna
     Mode of the test                        LTE 10MHz
     conducted output power       Downlink : 43 dBm , Uplink : 30 dBm
     Gain                                     55 ~ 95 dB




   Report Number :                 EST-P25-IO2-F04
   ESTRFC1901-002                     (2016.01.01)                                      4 of 32


       ESTECH CO., LTD.
                                                                             FCC ID : N52-SDR-ICS-437FN
      http://www.estech.co.kr


2. Laboratory Information

     2.1 Laboratory Name          Estech Co., Ltd.
     2.2 Location
         Head Office              Rm. 1015, World Venture Center II, 426-5 Gasan-dong
                                  Geumcheon-gu, Seoul, 153-803. Korea.
         EMC Lab(Yanggi)          97-1, Hoeeok-Ri Majang-Myon, Icheon-city, KyungKi-Do, Korea

     2.3 Quality System        Accredited by KOLAS(ISO/IEC 17025)
     2.4 Major Accredited Mark




3. Summary of Test Results

            Test Item                     Standard              Result
       Conducted RF Output
                                           2.1046               PASS
              Power
         Measuring AGC
                                     935210 D05 v01r02          PASS
          threshold level
        Occupied Bandwidth                 2.1049               PASS
       Out of Band Rejection         935210 D05 v01r02          PASS

        Spurious Emission at
                                           2.1051               PASS
         Antenna Terminal

     Radiated Spurious Emission            2.1053               PASS




     Note : Evaluation was performed in accordance with KDB 935210 and Washington
     Laboratories Test Plan (Document WLL Job #13257) and Correspondence with FCC.




   Report Number :                           EST-P25-IO2-F04
   ESTRFC1901-002                               (2016.01.01)                                5 of 32


         ESTECH CO., LTD.
                                                                                                FCC ID :        N52-SDR-ICS-437FN
        http://www.estech.co.kr

4. Measuring AGC threshold level Power and Conducted RF Output
4.1 Test Procedure according to KDB935210 D5 3.2

      a) Connect a signal generator to the input of the EUT.
      b) Connect a spectrum analyzer or power meter to the output of the EUT using appropriate attenuation as necessary.
      c) The signal generator should initially be configured to produce either of the required test signals (i.e., broadband or
      narrowband).
      d) Set the signal generator frequency to the center frequency of the EUT operating band.
      e) While monitoring the output power of the EUT, measured using the methods of 3.5.3 or 3.5.4, increase the
      input level until a 1 dB increase in the input signal power no longer causes a 1 dB increase in the output signal
      power.
      f) Record this level as the AGC threshold level.
      g) Repeat the procedure with the remaining test signal.


      2. Test setup for RF Conducted measurement




4.2 Test Equipments
      The following test equipments are used during tests
            Equipment                   Manufacturer                                    Model                          Next Cal.
       Spectrum Analyzer                   Agilent                                     E4440A                         2019-12-21
       Spectrum Analyzer           ROHDE&SCHWARZ                                       FSV40                          2019-12-21
        Signal Generator           ROHDE&SCHWARZ                                     SMBV100A                         2019-12-19
        Signal Generator           ROHDE&SCHWARZ                                      SMB100                          2019-12-20
            Attenuator                      SRT                                     F04-K1830-01                      2019-12-19
            Attenuator              Bird Electronic Corp                           100-SA-MFN-30                      2019-12-19
           Power Meter                     Agilent                                  MY45100570                        2019-12-19
          Power Sensor                     Agilent                                  MY45240427                        2019-12-19




    Report Number :                                      EST-P25-IO2-F04
    ESTRFC1901-002                                          (2016.01.01)                                                  6 of 32


         ESTECH CO., LTD.
                                                                    FCC ID :   N52-SDR-ICS-437FN
        http://www.estech.co.kr

4.3 Test Results : Pass
      Downlink

           Freq (MHz)       Intput Level (dBm)      Output (dBm)   Gain (dB)
             763.00               -52.22               42.93        95.15
             763.00               -51.70               42.96        94.66
             763.00               -50.00               42.90        92.90
             763.00               -49.00               42.89        91.89
             763.00               -40.00               42.91        82.91
             763.00               -30.00               42.86        72.86
             763.00               -20.00               42.91        62.91
             763.00               -13.00               42.93        55.93



      Uplink

           Freq (MHz)       Intput Level (dBm)      Output (dBm)   Gain (dB)
             793.00               -65.00               29.93        94.93
             793.00               -64.75               29.99        94.74
             793.00               -50.00               29.92        79.92
             793.00               -40.00               29.94        69.94
             793.00               -30.00               29.95        59.95
             793.00               -25.00               29.97        54.97




     Report Number :                             EST-P25-IO2-F04
     ESTRFC1901-002                                 (2016.01.01)                           7 of 32


         ESTECH CO., LTD.
                                                    FCC ID : N52-SDR-ICS-437FN
        http://www.estech.co.kr
4.4 Test Plot of Spectrum

      Downlink
      Input Signal




      Output Signal




    Report Number :               EST-P25-IO2-F04
    ESTRFC1901-002                   (2016.01.01)                 8 of 32


    ESTECH CO., LTD.
                                               FCC ID : N52-SDR-ICS-437FN
   http://www.estech.co.kr



 Uplink
 Input Signal




 Output Signal




Report Number :              EST-P25-IO2-F04
ESTRFC1901-002                  (2016.01.01)                 9 of 32


         ESTECH CO., LTD.
                                                                                                     FCC ID : N52-SDR-ICS-437FN
        http://www.estech.co.kr

5. Occupied Bandwidth
5.1 Test Procedure according to KDB935210 D5 3.4

      a) Connect a signal generator to the input of the EUT.
      b) Configure the signal generator to transmit the AWGN signal.
      c) Configure the signal amplitude to be just below the AGC threshold level (see 3.2), but not more
       than 0.5 dB below.
      d) Connect a spectrum analyzer to the output of the EUT using appropriate attenuation.
      e) Set the spectrum analyzer center frequency to the center frequency of the operational band under test.
      The span range of the spectrum analyzer shall be between 2 times to 5 times the emission bandwidth
      (EBW) or alternatively, the OBW.
      f) The nominal RBW shall be in the range of 1 % to 5 % of the anticipated OBW, and the VBW shall be
      ≥ 3 × RBW.
      g) Set the reference level of the instrument as required to preclude the signal from exceeding the maximum
      spectrum analyzer input mixer level for linear operation. In general, the peak of the spectral envelope
       must be more than [10 log (OBW / RBW)] below the reference level.
      Steps f) and g) may require iteration to enable adjustments within the specified tolerances.
      h) The noise floor of the spectrum analyzer at the selected RBW shall be at least 36 dB below
      the reference level.
      i) Set spectrum analyzer detection function to positive peak.
      j) Set the trace mode to max hold.
      k) Determine the reference value: Allow the trace to stabilize. Set the spectrum analyzer marker to the highest
      amplitude level of the displayed trace (this is the reference value) and record the associated frequency as f0.
      l) Place two markers, one at the lowest and the other at the highest frequency of the envelope of the spectral
      display, such that each marker is at or slightly below the −26 dB down amplitude. The 26 dB EBW
      (alternatively OBW) is the positive frequency difference between the two markers. If the spectral envelope
      crosses the −26 dB down amplitude at multiple points, the lowest or highest frequency shall be selected as the
      frequencies that are the furthest removed from the center frequency at which the spectral envelope crosses the −26
      dB down amplitude point.
      m) Repeat steps e) to l) with the input signal connected directly to the spectrum analyzer (i.e., input signal
      measurement).
      n) Compare the spectral plot of the input signal (determined from step m) to the output signal (determined from
      step l) to affirm that they are similar (in passband and rolloff characteristic features and relative spectral locations),
      and include plot(s) and descriptions in test report.
      o) Repeat the procedure [steps e) to n)] with the input signal amplitude set to 3 dB above the AGC threshold.
      p) Repeat steps e) to o) with the signal generator set to the narrowband signal.
      q) Repeat steps e) to p) for all frequency bands authorized for use by the EUT.




    Report Number :                                      EST-P25-IO2-F04
    ESTRFC1901-002                                          (2016.01.01)                                                  10 of 32


         ESTECH CO., LTD.
                                                                         FCC ID : N52-SDR-ICS-437FN
        http://www.estech.co.kr




5.2 Test Equipments


      The following test equipments are used during tests
                Equipment                      Manufacturer         Model              Next Cal.
            Spectrum Analyzer                    Agilent            E4440A            2019-12-21

            Spectrum Analyzer            ROHDE&SCHWARZ              FSV40             2019-12-21

             Signal Generator            ROHDE&SCHWARZ            SMBV100A            2019-12-19

             Signal Generator                      HP               E4438C            2019-12-19

             Signal Generator            ROHDE&SCHWARZ              SMB100            2019-12-20

                Attenuator                        SRT            F04-K1830-01         2019-12-19

                Attenuator                Bird Electronic Corp   100-SA-MFN-30        2019-12-19

               Power Meter                       Agilent          MY45100570          2019-12-19

               Power Sensor                      Agilent          MY45240427          2019-12-19




    Report Number :                            EST-P25-IO2-F04
    ESTRFC1901-002                                (2016.01.01)                        11 of 32


          ESTECH CO., LTD.
                                                     FCC ID : N52-SDR-ICS-437FN
         http://www.estech.co.kr
5.3 Test Results : Pass

       Downlink
       Input Signal




       Output Signal




     Report Number :               EST-P25-IO2-F04
     ESTRFC1901-002                   (2016.01.01)                12 of 32


    ESTECH CO., LTD.
                                               FCC ID : N52-SDR-ICS-437FN
   http://www.estech.co.kr



 Uplink
 Input Signal




 Output Signal




Report Number :              EST-P25-IO2-F04
ESTRFC1901-002                  (2016.01.01)                13 of 32


         ESTECH CO., LTD.
                                                                                                   FCC ID : N52-SDR-ICS-437FN
        http://www.estech.co.kr


6. Out of Band Rejection

6.1 Test Procedure
      a) Connect a signal generator to the input of the EUT.
      b) Configure a swept CW signal with the following parameters:
      1) Frequency range = ± 250 % of the passband, for each applicable CMRS band (see also KDB Publication
      935210 D02 [R7] and KDB Publication 634817 [R5] about selection of frequencies for testing and for grant
      listings).
      2) Level = a sufficient level to affirm that the out-of-band rejection is > 20 dB above the noise floor and will not
      engage the AGC during the entire sweep.
      3) Dwell time = approximately 10 ms.
      4) Number of points = SPAN/(RBW/2).
      c) Connect a spectrum analyzer to the output of the EUT using appropriate attenuation.
      d) Set the span of the spectrum analyzer to the same as the frequency range of the signal generator.
      e) Set the resolution bandwidth (RBW) of the spectrum analyzer to be 1 % to 5 % of the EUT passband, and the
      video bandwidth (VBW) shall be set to ≥ 3 × RBW.
      f) Set the detector to Peak Max-Hold and wait for the spectrum analyzer’s spectral display to fill.
      g) Place a marker to the peak of the frequency response and record this frequency as f0.
      h) Place two markers, one at the lowest and the other at the highest frequency of the envelope of the spectral
      display, such that each marker is at or slightly below the −20 dB down amplitude, to determine the 20 dB
      bandwidth.
      i) Capture the frequency response of the EUT.
      j) Repeat for all frequency bands applicable for use by the EUT.




    Report Number :                                     EST-P25-IO2-F04
    ESTRFC1901-002                                         (2016.01.01)                                                14 of 32


         ESTECH CO., LTD.
                                                                          FCC ID : N52-SDR-ICS-437FN
        http://www.estech.co.kr

6.2 Test Equipments

      The following test equipments are used during tests
              Equipment                    Manufacturer               Model             Next Cal.
          Spectrum Analyzer                   Agilent                E4440A            2019-12-21
          Spectrum Analyzer            ROHDE&SCHWARZ                 FSV40             2019-12-21
           Signal Generator            ROHDE&SCHWARZ               SMBV100A            2019-12-19
           Signal Generator                      HP                  E4438C            2019-12-19
           Signal Generator            ROHDE&SCHWARZ                SMB100             2019-12-20
              Attenuator                        SRT               F04-K1830-01         2019-12-19
              Attenuator                Bird Electronic Corp     100-SA-MFN-30         2019-12-19
             Power Meter                      Agilent             MY45100570           2019-12-19
             Power Sensor                     Agilent             MY45240427           2019-12-19




    Report Number :                            EST-P25-IO2-F04
    ESTRFC1901-002                                (2016.01.01)                          15 of 32


          ESTECH CO., LTD.
                                                            FCC ID :   N52-SDR-ICS-437FN
         http://www.estech.co.kr
6.3 Test Results : Pass


       Test Plot of Uplink




                                     Frequency (MHz)
                          marker 1       788.03
                          marker 2       797.98


       Test Plot of Downlink




                                     Frequency (MHz)
                          marker 1       758.13
                          marker 2       767.95




     Report Number :                      EST-P25-IO2-F04
     ESTRFC1901-002                          (2016.01.01)                   16 of 32


         ESTECH CO., LTD.
                                                                                                  FCC ID : N52-SDR-ICS-437FN
        http://www.estech.co.kr


7. Spurious Emission at Antenna Terminal

7.1 Test Procedure
      a) Connect a signal generator to the input of the EUT.
      b) Set the signal generator to produce the broadband test signal as previously described (i.e., 4.1 MHz OBW
      AWGN).
      c) Set the center frequency of the test signal to the lowest available channel within the frequency band or block.
      d) Set the EUT input power to a level that is just below the AGC threshold (see 3.2), but not more than 0.5 dB
      below.
      e) Connect a spectrum analyzer to the output of the EUT using appropriate attenuation as necessary.
      f) Set the RBW = reference bandwidth in the applicable rule section for the supported frequency band of operation
      (e.g., reference bandwidth is typically 100 kHz or 1 MHz).
      g) Set the VBW ≥ 3 × RBW.
      h) Set the Sweep time = auto-couple.
      i) Set the spectrum analyzer start frequency to the lowest RF signal generated in the equipment, without going
      below 9 kHz, and the stop frequency to the lower band/block edge frequency minus 100 kHz or 1 MHz, as
      specified in the applicable rule part.


      The number of measurement points in each sweep must be ≥ (2 × span/RBW), which may require that the
      measurement range defined by the start and stop frequencies be subdivided, depending on the available number of
      measurement points provided by the spectrum analyzer.4
      j) Select the power averaging (rms) detector function.
      k) Trace average at least 10 traces in power averaging (rms) mode.
      l) Use the peak marker function to identify the highest amplitude level over each measured frequency range.
      Record the frequency and amplitude and capture a plot for inclusion in the test report.
      m) Reset the spectrum analyzer start frequency to the upper band/block edge frequency plus 100 kHz or 1 MHz,
      as specified in the applicable rule part, and the spectrum analyzer stop frequency to 10 times the highest frequency
      of the fundamental emission (see Section 2.1057). The number of measurement points in each sweep must be ≥
      (2 × span/RBW), which may require that the measurement range defined by the start and stop frequencies be
      subdivided, depending on the available number of measurement points provided by the spectrum analyzer.
      n) Trace average at least 10 traces in power averaging (rms) mode.
      o) Use the peak marker function to identify the highest amplitude level over each of the measured frequency
      ranges. Record the frequency and amplitude and capture a plot for inclusion in the test report; also provide
      tabular data, if required.
      p) Repeat steps i) to o) with the input test signals firstly tuned to a middle band/block frequency/channel, and then
      tuned to a high band/block frequency/channel.
      q) Repeat steps b) to p) with the narrowband test signal.
      r) Repeat steps b) to q) for all authorized frequency bands/blocks used by the EUT.




    Report Number :                                    EST-P25-IO2-F04
    ESTRFC1901-002                                        (2016.01.01)                                                17 of 32


         ESTECH CO., LTD.
                                                                          FCC ID : N52-SDR-ICS-437FN
        http://www.estech.co.kr




6.2 Test Equipments

      The following test equipments are used during tests
              Equipment                    Manufacturer               Model             Next Cal.
          Spectrum Analyzer                   Agilent                E4440A            2019-12-21
          Spectrum Analyzer            ROHDE&SCHWARZ                 FSV40             2019-12-21
           Signal Generator            ROHDE&SCHWARZ               SMBV100A            2019-12-19
           Signal Generator            ROHDE&SCHWARZ                SMB100             2019-12-20
              Attenuator                        SRT               F04-K1830-01         2019-12-19
              Attenuator                Bird Electronic Corp     100-SA-MFN-30         2019-12-19
             Power Meter                      Agilent             MY45100570           2019-12-19
             Power Sensor                     Agilent             MY45240427           2019-12-19




    Report Number :                            EST-P25-IO2-F04
    ESTRFC1901-002                                (2016.01.01)                          18 of 32


          ESTECH CO., LTD.
                                                               FCC ID : N52-SDR-ICS-437FN
         http://www.estech.co.kr
6.3 Test Results : Pass

                                   Test Plot of Downlink




     Report Number :                         EST-P25-IO2-F04
     ESTRFC1901-002                             (2016.01.01)                   19 of 32


Spectrum
Rot Level 40.00 dam           3z.00 ds « raw 100
an            as as     swr   corrmaps e vaw 3 mc    Made auto FFT
Sot count
 im a
                                                           miQl)                 —aner
                                                                                747.100




           1 —13.000




stan 20.0 snz                                                           Stop     ya0.0 mz
                                                                                  inomes d



 Spectrum
 Rot Level 40.00               32.00 « raw 100
 au            as ao    awr       19 ps e vaw a mc      Mode Auto FFT
 Sat count
  ma
                                                            miQl)                 —20.i6
                                                                               757.90na0




             1 13000




 Stan 730.0 mine                             3000 prs                     Stop 750.0 mine




 Spectrum
 Raf Lovet 40.00              32.00 « raw 100
 Aam            as ao   sw       19 ps @ vaw o Mz     Mode Auto FFT
 sat count
  Trma
                                                            mill                  —an.2s
                                                                               760.07090




Stan 7ou.o mne                                                                    27o.0 mie
                                                                                   inmene P


Spectrum %
 Rof Level 40.00              32.00 « raw 100
 an             as as   swr   oas6 ps ® vaw .o Miz   Made auto FFT
 Sat. count
  iem a
                                                          mitu            027
                                                                       o4n.cn470




Stan   770.0 mvie                           aoooo pts                   Stop 1.0 ane




  Spectrum %
  Ret Level 40.00             32.00 & Row 1 iz
  an            as ao   ow      102 ms @ vaw a mz    Made Auto Sweep
  sat. count
   Tem a
                                                          wmitu           5.07
                                                                        6.271000




 San 1.0 one                                 20000 pts                 Stop 26.5 ane


    ESTECH CO., LTD.
                                                        FCC ID : N52-SDR-ICS-437FN
   http://www.estech.co.kr


                             Test Plot of Uplink




Report Number :                       EST-P25-IO2-F04
ESTRFC1901-002                           (2016.01.01)                   22 of 32


Spectrum
Rof Level 40.00              32.00 & raw 100
an             as ao    sw   o154 ps vaw o Mz         Mode auto FFT
Sat. count
 im a
                                                          miti            Eoul
                                                                         710.000




           1 —13.000




Stan a0.0 mine                             sooo pts                   Stop 770.0 inz




Spectrum
Rot Level 40.00              32.00 = Rew 100
an             as ao    ow      19 ps @ VBW 3 Mz      mode muto FFT
sat. count
 Tem avatog
                                                          mitu            —ar.en
                                                                       707.90030




Stan 770.0 e                               aoo0 pts                   Stop 700.0 nine




Spectrum
Rof Level 40.00 dam          32.00 = Rew 100
an             as ao    sw      19 ps @ VBW 3 Mz      mode muto FFT
Sat. count
 im a
                                                          mipy            Eas
                                                                       700.00170




            1 —12.000




Start 700.0 ie                             aoo0 pts                   Stop 800.0 MHiz


Spectrum
Ref Level 40.00 dam         3z.00 ds « Raw 1 Ne
an            as ds   awr     102 me @ vaw a mie   Made Auto Sweep
Sat. count
 irm a
                                                        mind            —25.76
                                                                      6.001230




stan   1.0 ane                              aoo00 pts                stop 26.5 anne


    ESTECH CO., LTD.
                                                            FCC ID : N52-SDR-ICS-437FN
   http://www.estech.co.kr


                             Test Plot of Intermodulation

                                Output Signal of Downlink




                                  Output Signal of Uplink




Report Number :                           EST-P25-IO2-F04
ESTRFC1901-002                               (2016.01.01)                   25 of 32


    ESTECH CO., LTD.
                                                        FCC ID : N52-SDR-ICS-437FN
   http://www.estech.co.kr


                             Test results of Downlink




Report Number :                       EST-P25-IO2-F04
ESTRFC1901-002                           (2016.01.01)                   26 of 32


    ESTECH CO., LTD.
                                                       FCC ID : N52-SDR-ICS-437FN
   http://www.estech.co.kr


                             Test results of Uplink




Report Number :                      EST-P25-IO2-F04
ESTRFC1901-002                          (2016.01.01)                   27 of 32


         ESTECH CO., LTD.
                                                                                                     FCC ID : N52-SDR-ICS-437FN
        http://www.estech.co.kr

8. Radiated Spurious Emission
8.1 Test Procedure according to KDB935210 D5 3.4
      This measurement is intended to produce test data necessary to demonstrate compliance to the radiated spurious
      emission requirements specified in Section 2.1053 of the FCC rules. This test is intended to capture any
      emissions that radiate directly from the case, cabinet, control circuits, etc., instead of via the antenna output port,
      and thus would not be captured in conducted spurious emission measurements. See KDB Publication 971168
      [R8] for measurement procedure guidance.
8.2 Test Equipments
      The following test equipments are used during tests
              Equipment                    Manufacturer                                     Model                        Next Cal.
            Spectrum Analyzer                    ADVANTEST                           FSV40              100939          2019-12-21
             Signal Generator                 ROHDE&SCHWARZ                        SMBV100A             2566633         2019-12-20
              TEST Receiver                   ROHDE & SCHWARZ                        ESCI7              100185          2019-10-22
            Logbicon Antenna                   SCHWARZBECK                         VULB 9168             237            2020-03-12
             PREAMPLIFIER                         AGILENT                            8449B            3008A00595        2019-10-23
             Signal Generator                        HP                             E4432B            GB40050840        2019-12-19
             Signal Generator                 ROHDE & SCHWARZ                      SMB 100A            177653           2019-12-20
              Horn Antenna                     SCHWARZBECK                        BBHA 9120 D            469            2020-04-30
              Loop Antenna                    ROHDE&SCHWARZ                         HFH2-Z2            100188           2020-04-30

8.3 Test Setup
       Test setup for 30 MHz to 1 GHz




      Test setup for above1 GHz




    Report Number :                                      EST-P25-IO2-F04
    ESTRFC1901-002                                          (2016.01.01)                                                 28 of 32


          ESTECH CO., LTD.
                                                                        FCC ID :    N52-SDR-ICS-437FN
         http://www.estech.co.kr
8.4 Test Results : Pass
       Downlink

       9 kHz ~150 kHz
         Frequency        Receiver   Correction Factor(dB)         Total(dBm)
           (MHz)          Reading    AG(dBi)      CL(dB)     SG Reading    Result   Limit(dBm)   Polarity
                          (dBuV)
                                                  No Critical Peak


       150 kHz ~30 MHz
         Frequency        Receiver   Correction Factor(dB)         Total(dBm)
           (MHz)          Reading    AG(dBd)      CL(dB)     SG Reading    Result   Limit(dBm)   Polarity
                          (dBuV)
                                                  No Critical Peak


       30 MHz ~1 GHz
         Frequency        Receiver   Correction Factor(dB)         Total(dBm)
           (MHz)          Reading    AG(dBd)      CL(dB)     SG Reading    Result   Limit(dBm)   Polarity
                          (dBuV)
                                                  No Critical Peak


       1 GHz ~26.5 GHz
         Frequency        Receiver   Correction Factor(dB)         Total(dBm)
           (MHz)          Reading    AG(dBd)      CL(dB)     SG Reading    Result   Limit(dBm)   Polarity
                          (dBuV)
                                                  No Critical Peak




     Report Number :                          EST-P25-IO2-F04
     ESTRFC1901-002                              (2016.01.01)                               29 of 32


    ESTECH CO., LTD.
                                                                FCC ID :    N52-SDR-ICS-437FN
   http://www.estech.co.kr

 Uplink

 9 kHz ~150 kHz
   Frequency      Receiver   Correction Factor(dB)         Total(dBm)
     (MHz)        Reading    AG(dBi)      CL(dB)     SG Reading    Result   Limit(dBm)   Polarity
                  (dBuV)
                                          No Critical Peak


 150 kHz ~30 MHz
   Frequency      Receiver   Correction Factor(dB)         Total(dBm)
     (MHz)        Reading    AG(dBd)      CL(dB)     SG Reading    Result   Limit(dBm)   Polarity
                  (dBuV)
                                          No Critical Peak


 30 MHz ~1 GHz
   Frequency      Receiver   Correction Factor(dB)         Total(dBm)
     (MHz)        Reading    AG(dBd)      CL(dB)     SG Reading    Result   Limit(dBm)   Polarity
                  (dBuV)
                                          No Critical Peak


 1 GHz ~26.5 GHz
   Frequency      Receiver   Correction Factor(dB)         Total(dBm)
     (MHz)        Reading    AG(dBd)      CL(dB)     SG Reading    Result   Limit(dBm)   Polarity
                  (dBuV)
                                          No Critical Peak




Report Number :                       EST-P25-IO2-F04
ESTRFC1901-002                           (2016.01.01)                               30 of 32


Multiview —>|    Spectrum
       L   0.00 dBm               © RBW 1 MHz
 Att           10 d8   SWT 101 ms ®@ VBW 1 MHz   Mode Auto Sweep   Frequency 9.5000000 GHz


                                                                                  —66.02
                                                                               17.776710




Multiiew ——)     Spectrum
       L   0.00 dBm               © RBW 1 MHz
 Att           10 d8   SWT 101 ms ®@ VBW 1 MHz   Mode Auto Sweep   Frequency 9.5000000 GHz


                                                                                  —66.17
                                                                               16.544730


    ESTECH CO., LTD.
                                                               FCC ID :   N52-SDR-ICS-437FN
   http://www.estech.co.kr

 Appendix 1. Uncertainty

                  Description               Frequency Range         Uncertainty

        Conducted RF Output Power            25 to 7000 MHz          ±0.45 dB

           Occupied Bandwidth                25 to 7000 MHz          ± 41 kHz

           Out of Band Rejection             25 to 7000 MHz         ± 0.48 MHz

       Spurious Emissions at Antenna
                                                   -                 ± 1.31 dB
                 Terminals
                                             25 to 1000 MHz           ±3.5 dB
       Radiated Spurious Emissions
                                           1000 to 40000 MHz          ±5.2 dB




Report Number :                        EST-P25-IO2-F04
ESTRFC1901-002                            (2016.01.01)                            32 of 32



Document Created: 2019-01-11 14:22:55
Document Modified: 2019-01-11 14:22:55

© 2024 FCC.report